EXCENTR EX100105 Air 100 Air Cleaner with HEPA+UVC Filter User Manual

June 5, 2024
EXCENTR

EXCITER AIR 100
User Manual

Read the instructions carefully before you start using the appliance.
WWW.EXCENTR.COM

Congratulations on your purchase of the Excentr Air 100 Purifier by LUMITENSO Clean Air / EXCENTR

Please read this user manual carefully before you start using the Air Purifier and store it at a safe place to keep it at hand any time. It contains important information on installation, usage and maintenance of the appliance. In case you have any questions or suggestions feel free to contact us.

Excentr bv. – Zinkstraat 59, 4823 AC Breda
The Netherlands
www.excentr.com
T: +31 (0)88-1700601
E-Mail: [email protected]

Please find us on www.excentr.com for more information.

Specifications

Model LCA-388
Colour White
Size 400200600mm
Certification CE, CB, CQC, CCC, Rohs, ERR SGS, SGS approved
Rated voltage 220V / 50Hz
Power 90W
CADR 388m3/h
Max room floor area Ca. 40m2
Noise level 18dB – 55dB
Fitter structure 7-way-purification: Pre-filter, Cold Catalyst Filter,

Cellular-Activated Carbon Filter, Antibacterial Cotton Filter,

High-Efficiency HEPA Filter, Sterilizing UV light, Anion Purifier

Sensors| Filter sensor (indicates necessary replacement of filters) – PM2.5 Display (indicates air quality)
Sterilization| 265 nanometers UV-C-radiation
Operation| Toch panel + remote control
Housing material| ABS / acryl-case
Anion Purification| 20MM /cm3
Fitter performance| PM 2.5 – 99,95% HEPA-H13
Net weight| 9,7 kg

Please find us on www.excentr.com for more information.

Safety

Please read the entire instruction manual before using the product and then save it for future refer­ence. We reserve the right for any errors in text or images and any necessary changes made to tech­nical data. In the event of technical problems or other queries, please contact our Customer Services (see address details on the back

  • The product may be used by children of 8 years and above and by persons with reduced phys­ical, sensory or mental capability or lack of experience and knowledge provided they have been given supervision or instruction concerning the use of the product in a safe way and understand the hazards involved.
  • Never let children play with the product.
  • Cleaning and user maintenance shall not be made by children without adult supervision.
  • Persons (including children) whose physical, sensory, or mental capability or lack of experience and knowledge means that they cannot use the product in a safe way must not use it without supervision or instruction.
  • The product must only be connected to a standard domestic 220-240 V, 50 Hz electrical supply.
  • The product is only intended for normal domestic use and only in the manner described in this instruction manual.
  • The product is intended for indoor use only.
  • The product is only intended for use in a normal indoor environment. It must not be used in extremely smoky or dusty locations.
  • The product is no compensation for regular air ventilation or extractor fans.
  • Always plug the product directly into a wall socket. Do not connect the product to a wall socket via an extension lead or trailing socket.
  • The product must never be used with a timer or other equipment which turns it on automatically.
  • If the mains lead is damaged it should only be replaced by a qualified electrician.
  • Always unplug the mains lead before cleaning, servicing, or moving the product.
  • Never use the product in areas where combustible or explosive gases or liquids are stored.
  • Never place the product where there is a risk of it falling into water or other types of liquid.
  • Never use the product in a moist or hot environment like bathrooms or kitchens.
  • Never use the product in areas exposed to high-temperature fluctuations to prevent condensa­
  • The product must only be placed on a firm, flat surface.
  • The product must only be used in places with at least 50 cm distance to walls or neighboring
  • The product must only be repaired by qualified service technicians using original spare parts.
  • Never use the product if your hands are moist or wet.
  • Never place any items on top of the product.
  • Never insert foreign objects into the air inlet or outlet.
  • Switch the product off and unplug it from the wall socket immediately if it tips over. Make sure that the product is completely intact before using it for the first time. If you have the slightest suspicion that the product is damaged, have it inspected by qualified service technicians before using it,
  • Unplug the product from the wall socket during thunderstorms.
  • Place the product in such a way that there is no risk of people tripping over its main lead.
  • Do not place the mains lead where it can be crushed or damaged by sharp edges.
  • Unplug the device if it produces unusual sounds or vibrations, burnt scent, smoke, or unusual warmth on the mains lead or socket. Then immediately call our customer service.
  • Never use the product if it or its mains lead is damaged in any way, or if the covers are not installed correctly.

Installation

  1. Preparation

  2. Installation of filters and front cover

Functions

Switch on and off

| Press the power button to start the appliance. It will enter into automatic mode. At this time the motor gears are controlled by the sensor. Press the button again to put the appliance back into STANDBY mode
---|---

Set operating mode

| Press the wind speed button to change the motor gear, circulating from 1 to 3. When the wind speed is changed, the machine will exit automatic mode. Hold the button for 3 seconds to re-enter automatic mode.
---|---
| The anion button is for turning on and off the anion function.
| The UV Sterilizer button is for turning on and off the UV light function.
| Press the sleep button to enter into first gear and exit automatic mode. All the lights and the display will turn off. Hold the sleep button for 3-5 seconds to reset the filter replacement light after having replaced the filters.
|

When the machine is running, you can set the working time with the timer button. You can set the time in increments of 30 minutes. The shortest time you can set is 30 minutes, the longest is 12 hours. (It will display as 00:30,1:00, 1:30-12:00). Five seconds after setting the time, the display will go back to the PM2.5 value. After the timer is set, it will run in the background, counting down in minutes. Hold the timer for 5 seconds to exit this func-tion. Press the button to display the remaining time left.

| Press the child lock button to enter the child lock function. Hold the child lock button for 5 seconds to exit the function. Hold the child lock button before entering the mode to see total time filter has been used, between 0-1500 hours. After displaying for 5 seconds it will automatically exit the display.
| While operating, press the auto button to enter automatic mode.
| While operating in automatic mode, when the ambient light is <5Ix for 3 minutes, the machine will enter sleep mode. When ambient light is >51x for 3 minutes, it will exit sleep mode and continue running in automatic.

Remote control

This product is equipped with a remote control that uses button cell batteries. If not using the remote control long-term, please remove the batteries.

Note: the remote buttons correspond to the same buttons on the operational panel, with the same functions and operations.

Diffuser-Function

If you want to use the diffuser function, pull out the diffuser box on the left side of the product, drop essential oils onto the diffuser cloth and set it back.

Filter Maintenance:

  1. Pre-Filter
    Regularly clean the surface of the filter with a vacuum cleaner or wash with water. Allow drying thoroughly.

  2. Cellular-Activated Carbon, Cold Catalyst Filter
    Clean the dust from the front of the filter with a vacuum cleaner every two months. Place the filter in a ventilated area, this will allow harmful gasses and germs to dissipate. Do not place under too much sun exposure. The filter is delicate. Do not press too hard on the filter while vacuuming. Do not use water to clean this filter. It should be replaced every 6 months.

  3. Antibacterial cotton, H EPA Filter
    Place the filter in a ventilated area every two months, this will allow harmful gasses and germs to dissipate. Do not place under too much sun exposure. Do not use water to clean this filter. It should be replaced every 6 months.

  4. Anion Producer
    When you hear the machine produce a creaking sound, use a #1 or #2 paintbrush as a cleaning tool. Insert the brush from the ventilation window above the anion emission head. Regularly clean the dust all around the emission head.

  5. Particulate Sensor
    Wischen Sie die Linse des Partikelsensors regelmaBig vorsichtig..mit einem Wattestabchen sauber, urn Feuchtigkeit oder andere ROckstande zu entfemen (Abb. 2). Offnen Sie claftir zunachst die Sensorkappe (Abb. 1). Achten Sie darauf, dass das Wattestabchen keine anderen Bestandteile des Gerates beruhrt als die Linse. Nehmen Sie ggf. eine Taschenlampe zur Hilfe.
    Please find us on www.lumitensoair.de for more information.

Friendly reminders:

  • Before cleaning and maintenance, unplug the power cord.
  • Do not operate the machine in absence of a filter. It will not be able to remove the dust. Dust taken into the machine may cause malfunction.
  • You may need to replace filters sooner depending on where and how you use the appliance (such as a household with a large smoking population or areas with higher air pollution). Replace the filter if filtration is not noticeable.

Scope of Supply

1 x Body
1 x Remote Control
3 x Filters
1 x User Manual

Troubleshooting

Malfunction Inspect / How to fix
Cannot turn on the power or pressing button has no response.
  1. Is the Power cord plugged in? Plugin the power cord.
  2. Is the purifier covered? Close the front cover
  3. Is the machine placed vertically on the ground? Place the ma­chine on a flat surface. Is the machine in child-lock mode? When “Child-lock” appears on the display, hold the lock/reset button for 5 seconds to turn off the child-lock.

The air is dirty, but the air pollution indicator says “green’: The air pollution indicator remains “red” even when continuously running.| 1. Is the purifier in a place that cannot easily absorb the dirty air (dust)? Move it somewhere else.
2. Is the particulate sensor dirty? Clean the particulate sensor.
There is a banging or chirping sound while running.| Is there too much dust on the anion producer? Clean the anion producer.
The smell of the supply vent is unpleasant.| 1. Is the filter dirty? Clean the filter.
2. Has the filter been replaced in a long time? Replace the filter.
The purifier has been running for a long time but has had no significant improvement in air quality.| 1. Was the plastic bag on the filter removed? Remove the plastic bag from the filter before using it.
2. Is the filter order incorrect?
The display shows F1 or F2.| Please turn off the power immediately and contact the mainte­nance department.
The machine immediately goes to sleep mode.| Deactivate automatic mode.

The risk of infection through contaminated aerosols cannot be eliminated, but significantly reduced by using this Air Purifier. We suggest adjusting the Air Purifier so that the room air is filtered at least 4 times per hour.

Please find us on www.excentr.com for more information.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EXCENTR User Manuals

Related Manuals