testo 0554 0620 Bluetooth IRDA Printer Instruction Manual
- June 5, 2024
- testo
Table of Contents
testo 0554 0620 Bluetooth IRDA Printer Instruction Manual
Safety and the environment
- Dispose of faulty rechargeable batteries/spent batteries in accordance with the valid legal specifications.
- At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal.
Specifications
Use
The testo Bluetooth® /IRDA printer is used to produce report printouts, in
conjunction with compatible devices:
E.g. testo 330 (0632 3306 – 3307 from firmware 2.02 onwards), testo 320 (from
firmware 1.06 onwards), testo 324 (from firmware 1.08 onwards), testo 330i
(0554 0621 only)
The use of the wireless module is subject to the regulations and stipulations
of the respective country of use, and the module may only be used in countries
for which a country certification has been granted.
The user and every owner has the obligation to adhere to these regulations and
prerequisites for use, and acknowledges that the resale, export, import etc.
in particular in countries without wireless permits, is his responsibility.
General data
Feature | Values |
---|---|
Model | Thermal printer with Bluetooth® and IrDA interface |
Printing speed | 30 mm/s |
Operating temperature | 0 to +50 °C / 32 to 122 °F |
Storage temperature | -20 to +50 °C / -4 to 122 °F |
Dimensions (LxWxH) | 150 mm x 80 mm x 41 mm |
Weight | approx. 400 g (including rechargeable battery pack, paper roll, mains |
unit)
---|---
EU Directive| 2014/30/EC
Power supply| Lithium-Ion rechargeable battery pack, 2600 mAh, 3.7 V
Thermal paper roll| 56.5 mm x 34 mm x 12 mm
Rechargeable battery storage temperature| ±0 to 35 °C / 32 to 95 °F
Rechargeable battery charge time| approx. 5-6 h
Rechargeable battery life| approx. 50 m report printouts
Bluetooth® (optional)| Range < 10 m
Warranty| 2 years (excl. printer mechanism, rechargeable battery pack)
Warranty terms| Warranty terms: see website
www.testo.com/warranty
Bluetooth ® data 0554 0620
Feature | Values |
---|---|
Type designation | Bluegiga WT12 |
Specification | 2.0 |
Radio class | Class 2 |
Coverage | < 10 m / < 32.8 ft. |
Product note | WT12 |
Identification | B011198 |
Company | 10274 |
Certification | EU countries: |
Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE), Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg (LU), Malta
| (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania
(RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain (ES), Czech Republic
(CZ), Hungary (HU), United
Kingdom (GB), Republic of Cyprus (CY).
EFTA countries:
Iceland, Liechtenstein, Norway, Switzerland
Other countries:
Colombia, El Salvador, Turkey, Ukraine, Australia, USA, Canada
FCC (Federal Communications Commission) notice
This instrument fulfils part 15 of the FCC Rules
Its commissioning is subject to the following two conditions:
this instrument must not cause any harmful interference and
this instrument must be able to cope with interference, even if this has
undesirable effects on operation.
Changes
The FCC demands that the user be informed that any changes or modifications
to the instrument that are not explicitly approved by testo AG may void the
user’s right to use this instrument.
---|---
Bluetooth ® data 0554 0621
Feature | Values |
---|---|
Type designation | Stollmann E+V GmbH BlueMod+SR (August 2013) |
Specification | 4.0, Bluetooth® Classic / LowEnergy |
Coverage | < 10 m / < 32,8 ft. |
Product note | BlueMod+SR |
Identification | B021281 |
Company | 44784 |
Certification
Country | Comments |
---|---|
EU + EFTA | EU countries: |
Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland
(FI), France (FR), Greece (GR), Ireland (IE), Italy (IT), Latvia (LV),
Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Austria (AT),
Poland (PL), Portugal (PT), Romania (RO), Sweden (SE), Slovakia (SK), Slovenia
(SI), Spain (ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB),
Republic of Cyprus (CY).
EFTA countries:
Iceland, Liechtenstein, Norway, Switzerland
Australia|
| E1561
Turkey| Authorized
India| Authorized
Canada| Contains FCC ID: 4957A-MSR Product IC ID: -20160621
IC Warnings
USA| Contains FCC ID: RFRMS Product FCC ID: WAF-20160621
FCC Warnings
Korea| MSIP-RMM-TE1-BTIRDA KCC Warning
Japan|
Japan Information
IC Warnings
This instrument complies with Part 15C of the FCC Rules and Industry Canada RSS-210 (revision 8). Commissioning is subject to the following two conditions:
- This instrument must not cause any harmful interference and
- this instrument must be able to cope with interference, even if this has undesirable effects on operation.
FCC Warnings
Information from the FCC (Federal Communications Commission)
For your own safety
Shielded cables should be used for a composite interface. This is to ensure
continued protection against radio frequency interference.
FCC warning statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. Shielded
interface cable must be used in order to comply with the emission limits.
Warning
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Accessories/spare parts
Description | Item no. |
---|---|
Mains unit 5 V / 1.0 A with micro USB cable | 0554 1105 |
Spare thermal paper, 6 rolls | 0554 0568 |
EC declaration of conformity 0554 0620
EC declaration of conformity 0554 0621
Product description
Overview
-
Bluetooth® /infrared interface
-
Operating mode indicator
-
On/Off control key
-
Paper feed control key
-
Paper roll (printable side out)
-
Paper compartment cover
-
Magnetic holder (on back)
WARNING
Magnetic field
May be harmful to those with pacemakers.
Keep a minimum distance of 10 cm between pacemaker and printer.
CAUTION
Magnetic field
Damage to other devices!
Keep a safe distance away from products that could be damaged by the effects of magnetism (e.g. monitors, computers or credit cards). -
Micro USB connection for connecting to the mains unit or the PC.
Operating mode indicator
LED | Function |
---|---|
Steady green light | Standby mode |
Printing out print data
Flashing green light| Receiving print data
Steady red light| Not ready for operation
Paper compartment cover open
No paper inserted.
Flashing red light| Rechargeable battery low
Flashing red/green light| Rechargeable battery is charging
Off| Sleep mode, automatically activated 2 minutes after a button was last
pressed
Control key functions
Control keys | Functions |
---|---|
Switch on printer: press key < 2 s |
Switch off printer: press key > 2 s
| Short paper feed: press key < 1 s
Paper feed for as long as the key is pressed:
press key > 1 s
and | Start a test print (printer is switched off): press keys < 1 s
simultaneously
Bluetooth® module test (printer is off): press keys > 1 s simultaneously
---|---
First steps
Charging the rechargeable battery
The rechargeable battery can only be charged at an ambient temperature of ±0
to +35 °C. If the rechargeable battery has been completely discharged,
charging time at room temperature using the testo mains unit is approx. 6 h.
Connect battery charger (0554 1105) to a mains socket and connect the printer.
If stored for a prolonged period of time, the battery should be charged every once in a while because otherwise this may result in damage due to deep discharge.
- Plug the mains unit instrument plug into the instrument’s micro USB socket.
- Plug the mains plug of the mains unit into a mains socket.
- The charging process will start. The charging process will stop automatically when the battery is fully charged.
Battery care
Do not fully exhaust rechargeable batteries.
Inserting paper
- Flip paper compartment cover up.
- Insert paper roll, see illustration.
- Close paper compartment cover.
Using the product
Printing data
When first setting up a connection between a testo measuring instrument and the Bluetooth / IRDA printer, the initialization phase can last up to 30 seconds.
- Printer is switched on.
- Start the print process from the instrument transmitting the data.
- Data is printed out (LED flashes green).
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>