testo 610 Pocket-Sized Air Humidity Measuring Instrument Instruction Manual

October 30, 2023
testo

testo 610 Pocket-Sized Air Humidity Measuring Instrument

testo-610-Pocket-Sized-Air-Humidity-Measuring-Instrument-PRODUCT-IMG

Product Information for Testo 610

The Testo 610 is a humidity/temperature measuring instrument that is used to measure humidity in offices, storerooms, buildings, and greenhouses. It has a temperature coefficient of type (k=1) 0.06 %rF / K.

Leistungsbeschreibung

The Testo 610 has the following features:

  • Humidity/temperature measuring instrument
  • Measures humidity in various settings
  • Easy-to-use control keys
  • Battery compartment for easy replacement

Product Usage Instructions

To use the testo 610, follow these steps:

  1. Switch on the instrument by pressing the power button.
  2. To switch on the display light for 10 seconds, press the display light button.
  3. Select the display size using the up and down keys: % (relative humidity), td (dew point temperature), or web (wet bulb temperature).
  4. Select the display mode using the up and down keys: Current reading, Hold (readings are held), Max (maximum values), or Min (minimum values).
  5. To switch off the instrument, press and hold the power button for 2 seconds.

Safety and Environmental Information

Before using the Testo 610, please read the documentation carefully and familiarize yourself with the product. Pay particular attention to information emphasized by the “Important” symbol. To avoid personal injury or damage to equipment, only operate the measuring instrument properly, for its intended purpose, and within the parameters specified in the technical data. Do not use force and never store the product together with solvents, acids, or other aggressive substances. Only carry out maintenance and repair work that is described in the documentation and use only OEM spare parts from Testo. Do not use the device in a polluted environment (heavily dusty, oil, foreign matter, volatile chemicals). To protect the environment, take faulty rechargeable batteries as well as spent batteries to the collection points provided for them. Send the product back to Testo at the end of its useful life, and they will ensure that it is disposed of in an environmentally friendly manner.

Short manual testo 610

testo-610-Pocket-Sized-Air-Humidity-Measuring-Instrument-
FIG-1

  1. Protection cap: Park position
  2. Humidity/temperature sensor
  3. Display
  4. Control keys
  5. Battery compartment (on rear)

Basic settings

  • Instrument off >press and hold 2s > select with , confirm with :
  • Unit of temperature: °C, °F > Auto-off function: OFF, ON
  • Switching the instrument on
  • Press . Switching the display light on (for 10s)
  • The instrument on > press Select display size
  • The instrument on > select with: % (relative humidity), td (dew point temperature), wb (wet bulb temperature)

Select display mode

  • The instrument on > select with :
  • Current reading > Hold: Readings are held > Max: Maximum values > Min: Minimum values
  • Switching the instrument off:
  • The instrument on >press and hold 2s.

Safety and the Environment

About this document

Please read this documentation carefully and familiarise yourself with the product before putting it to use. Keep this document to hand so that you can refer to it when necessary. Hand this documentation on to any subsequent users of the product. Pay particular attention to information emphasized by the following symbols:

Important

Avoid personal injury/damage to equipment

  • Only operate the measuring instrument properly, for its intended purpose, and within the parameters specified in the technical data. Do not use force.
  • Never store the product together with solvents, acids, or other aggressive substances.
  • Only carry out the maintenance and repair work that is described in the documentation. Follow the prescribed steps when doing so. Use only OEM spare parts from Testo.
  • Do not use the device in a polluted environment (heavily dusty, oil, foreign matter, volatile chemicals).

Protecting the environment

  • Take faulty rechargeable batteries as well as spent batteries to the collection points provided for them.
  • Send the product back to Testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner.

Specifications

Functions and use

  • The testo 610 is a humidity/temperature measuring instrument.
  • It is normally used to measure the humidity in offices and storerooms, buildings, and greenhouses.

Technical data

Measurement data

  • Sensors: Testo humidity sensor, NTC temperature sensor
  • Parameters: °C, °F, %rH, wet bulb, td
  • Measuring ranges: -10…50 °C, 14…122 °F, 0…100 %rH
  • Resolutions: 0.1 °C, 0.1 °F, 0.1 %rH
  • Accuracies (Nominal temperature 25 °C, ±1 Digit): ±0.5 °C, ±0.9 °F, ±2.5%rH (5…95%rH)
  • Long-term stability: ±1 %rF / year
  • Measuring rate: 1.0 s

Further instrument data

  • Protection class: IP20
  • Ambient conditions: -10…50 °C, 14…122 °F
  • Storage/transport conditions: -40…70 °C, -40…158 °F
  • Temperature coefficient: type (k=1) 0.06 %rF / K
  • Voltage supply: 2x 1.5 V type AAA
  • Battery life: 200 h (without display light)
  • Dimensions: 119x46x25 mm (inc. protection cap)
  • Weight: 90 g (inc. batteries and protection cap) Directives, standards, and tests
  • EC Directive: 2014/30/EU

Product Description

At a glance

testo-610-Pocket-Sized-Air-Humidity-Measuring-Instrument-
FIG-7

  1. Protection cap: Park position
  2. Humidity/temperature sensor
  3. Display
  4. Control keys
  5. Battery compartment (on rear)

First steps

  • Inserting batteries:
  1. To open the battery compartment, push the battery cover down.
  2. Insert batteries (2x 1.5 V type AAA). Observe the polarity!
  3. To close the battery compartment, push the battery cover back on.

Basic settings (configuration mode):

Adjustable functions

  • Unit of temperature: °C, °F
  • Auto off function: OFF, ON (instrument switches off automatically if no key is pressed for 10 minutes)
  1. When switching the instrument on, press and hold until and appear on the display (configuration mode).
    • The adjustable function is displayed. The current setting flashes.
  2. Press several times until the desired setting flashes.
  3. Press to confirm the input.
  4. Repeat steps 2 and 3 for all functions.
    • The instrument changes to measuring mode.

Using the product

  • To guarantee correct readings: Keep temperature and humidity sources that may falsify the measurement (e.g. hands) away from the sensor.
    • Switching the instrument on:
  • Press .
    • The measuring mode is opened.
    • Switching the display light on:
    • The instrument is switched on.
  • Press .
    • The display light goes out automatically if no key is pressed for 10 seconds.
  • Changing the parameter:

Adjustable units

  • % (relative humidity)
  • td (dew point temperature)
  • wb (wet bulb temperature)
  • Press until the desired parameter appears.
  • Changing the display view:

Adjustable views

  • Current reading
  • Hold: Readings are held.
  • Max: Maximum values since the instrument was last switched on or last reset.
  • Min: Minimum values since the instrument was last switched on or last reset.
  • Press several times until the desired view appears.

Resetting Max/Min values

  1. Press several times until the desired view appears.
  2. Press and hold until – – – – appears.
  3. Repeat steps 1 and 2 for all values that are to be reset.
    • Switching the instrument off:
    • Press and hold until the display goes out.

Maintaining the product

  • Changing batteries:
    • To open the battery compartment, push the battery cover down.
    • Remove used batteries and insert new batteries(2x 1.5 V type AAA). Observe the polarity!
    • To close the battery compartment, push the battery cover back on.
  • Cleaning the housing:
  • Clean the housing with a moist cloth (soap suds) if it is dirty. Do not use aggressive cleaning agents or solvents!

Tips and Assistance

Questions and answers

  • Question Possible causes/solutions
  • Hi or Lo · Readings outside the measuring range (too high, too low): Keep to the permitted measuring range.
  • Residual capacity <10 min: Change batteries.

If we could not answer your question, please contact your dealer or Testo Customer Service. For contact details, please visit www.testo.com/service- contact.

Testo SE & Co. KGaA

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

testo User Manuals

Related Manuals