DRAPER 52320 Digital Multimeter Instruction Manual
- June 5, 2024
- DRAPER
Table of Contents
DRAPER 52320 Digital Multimeter
GENERAL INFORMATION
This manual has been compiled by Draper Tools and is an integrated part of the
product with which it is enclosed and should be kept with it for future
references.
This manual describes the purpose for which the product has been designed and
contains all the necessary information to ensure its correct and safe use. We
recommend that this manual is read before any operation or, before performing
any kind of adjustment to the product and prior to any maintenance tasks. By
following all the general safety instructions contained in this manual, it
will ensure both product and operator safety, together with longer life of the
product itself.
All photographs and drawings in this manual are supplied by Draper Tools to
help illustrate the operation of the product.
Whilst every effort has been made to ensure accuracy of information contained
in this manual, the Draper Tools policy of continuous improvement determines
the right to make modifications without prior warning.
DECLARATION OF CONFORMITY
We :
Draper Tools Ltd.,
Hursley Road,
Chandler’s Ford,
Eastleigh, Hampshire.
SO53 1YF.
England.
Declare under our sole responsibility that the product:
Stock No:- 52320.
Part No:- DMM7.
Description:- Digital Multimeter.
To which this declaration relates is in conformity with the following
directive(s) 73/23/EEC, 93/68/EEC &
89/366/EEC.
With reference to: EN61010-1, EN61010-2-31, EN50081-1 & EN50082-1.
J.N. Draper
Managing Director
SPECIFICATION
The Draper Tools policy of continuous improvement determines the right to change specification without notice.
Stock No. …………………………………………………………………………………………………………. 52320
Part No. …………………………………………………………………………………………………………… DMM7
Battery type ……………………………………………………………………………………………………… 1x12V
Dimension ……………………………………………………………………………………………. 55x112x40mm
Weight ………………………………………………………………………………………………………………… 70g
-
AC VOLTAGE Input impedance: 450K , Input protection: 500V RMS, Frequency Range: 40Hz-400Hz.
-
DC CURRENT Overload protection: 200mA/250V fuse.
-
RESISTANCE
-
DIODE CHECK Test Current: 1.6mA typical.
reading = accuracy of the measurement circuit
digits = accuracy of the analogue to digital conversion
WARNING: Ensure the test leads are fully engaged prior to carrying out any
measurements, to avoid an electric shock.
GUARANTEE
Draper Tools have been carefully tested and inspected before shipment and are
guaranteed to be free from defective materials and workmanship for a period of
12 months from the date of purchase except where tools are hired out when the
guarantee period is ninety days from the date of purchase.
Should the machine develop any fault, please return the complete tool to your
nearest authorized warranty repair agent or contact Draper Tools Limited,
Chandler’s Ford, Eastleigh, Hampshire, SO53 1YF. England. Telephone: (023)
8026 6355.
If upon inspection it is found that the fault occurring is due to defective
materials or workmanship, repairs will be carried out free of charge. This
guarantee does not apply to normal wear and tear, nor does it cover any damage
caused by misuse, careless or unsafe handling, alterations, accident, or
repairs attempted or made by any personnel other than the authorised Draper
warranty repair agent.
This guarantee applies in lieu of any other guarantee expressed or implied and
variations of its terms are not authorised.
Your Draper guarantee is not effective unless you can produce upon request a
dated receipt or invoice to verify your proof of purchase within the 12 month
period.
Please note that this guarantee is an additional benefit and does not affect
your statutory rights.
Draper Tools Limited.
GETTING TO KNOW YOUR MULTIMETER
- Function Selector.
- Power Switch.
- L.C.D. Screen.
- Probes.
- V, , mA (Voltage, Resistance, Amperage) Jack Socket.
- Common Earth Jack Socket.
UNPACKING: After removing the packing material, make sure the product is
in perfect condition and that there are no visible damaged parts. If in doubt,
do not use the digital multimeter and contact the dealer from whom it was
purchased.
The packaging materials (plastic bags, polystyrene, etc.), must be disposed of
in an appropriate refuse collection container. These materials must not be
left within the reach of children as they are potential sources of danger.
GETTING TO KNOW YOUR MULTIMETER
– OTHER METER MARKINGS
ASSEMBLY
Remove the rubber case. Turn the meter over and remove the screws holding the
housing together. Carefully part the front and back housing of the meter. Do
not touch any of the internal components. Insert the appropriate battery
taking note of the polarity. Close the housing (do not force) and resecure.
The internal fuse can be replaced in the same manner.
To ensure an accurate reading, ensure the test probe are fully engaged.
OPERATION AND USE
WARNINGS: Each time before you use this analyser, inspect the test leads,
connectors and probes for damage, e.g. cracks or breaks in the insulation. Any
defective leads should be replaced immediately. If the value to be measured is
not known, set the selector switch to the highest range and reduce until a
satisfactory reading is obtained.
VOLTAGE MEASUREMENT:
- Connect the red test lead to the ‘V/ /mA’ jack socket and the black lead to the ‘com’ jack socket Ensure the leads are correctly plugged in.
- Position the selector switch to the desired voltage range and switch the meter ‘ON’.
- Connect the test leads to the circuit to be measured.
- Turn on the power to the circuit to be measured, the voltage value should appear on the digital display along with the voltage polarity (if reversed only).
CURRENT MEASUREMENT (Fig.1.):
- Connect the red test lead to the ‘V/ /mA’ jack socket and the black lead to the ‘com’ jack socket (max 10A).
- Position the selector switch to the desired amp range and switch the meter ‘ON’.
- Open the circuit to be measured, and connect the test leads in series to bridge the gap.
- Turn on the power to the circuit to be measured, the ‘current’ value should appear on the digital display.
RESISTANCE MEASUREMENT:
WARNING: If the resistance to be measured is part of a circuit, turn off and disconnect the power and discharge all capacitors before measurement
- Connect the red test lead to the ‘V/ /mA’ jack socket and the black lead to the ‘com’ jack socket.
- Position the selector switch to the desired ohm range and switch the meter ‘ON’.
- Connect the test leads to the circuit to be measured.
- The resistance value should now appear on the digital display.
MAINTENANCE
The fuse rarely needs replacing, and almost always a blown fuse is the result of an operator error.
WARNING: If the resistance to be measured is part of a circuit, turn off
and disconnect the power and discharge all capacitors before measurement
If the meter battery is in need of replacement (see Assembly section) the ’
symbol will appear ‘ on the display.
CONTACTS
DRAPER TOOLS LIMITED,
Hursley Road,
Chandler’s Ford,
Eastleigh,
Hampshire.
SO53 1YF. U.K.
Helpline: (023) 8049 4344.
Sales Desk: (023) 8049 4333.
General Enquiries: (023) 8026 6355.
Fax: (023) 8026 0784
Internet: www.draper.co.uk
E-mail: sales@drapertools.com
©Published by Draper Tools Limited.
No part of this publication may be reproduced, stored in a retrieval system or
transmitted in any form or by any means, electronic, mechanical photocopying,
recording or otherwise without prior permission in writing from Draper Tools
Ltd.