EXPERT POWER IVOCH24V3KW 24V 3KW Pure Sine Wave Inverter Charger User Guide
- June 5, 2024
- EXPERT POWER
Table of Contents
- EXPERT POWER IVOCH24V3KW 24V 3KW Pure Sine Wave Inverter Charger
- General Information
- Product Overview
- Applications
- Diagram
- Technical Specs
- AC/DC Operation
- Charger
- Top Panel Settings
- Wiring Guide
- Alarm Control & Behavior
- LED Indicators & Error Codes
- Troubleshooting for Audible and Visual Indicators
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXPERT POWER IVOCH24V3KW 24V 3KW Pure Sine Wave Inverter Charger
PLEASE READ INSTRUCTIONS BEFORE CONTINUING
This manual contains important safety installation, and operation instructions
for the ExpertPower Inverter-Charger. Please do not operate the Inverter-
Charger without reading this manual first.
General Information
Safety Information and Warnings
Before designing and during production, the safety of the consumer and
product have all been considered. Please follow the user instructions
carefully to operate or install the machine to prevent injury or accident.
Please keep this manual for future reference.
-
The installation of the inverter should be done by professionals or under the assistance of a local dealer.
-
Verify whether the input DC voltage range meets voltage polarity requirements (24V±20%). Confirm whether the load device voltage is single-phase 100V ~ 120VAC; power should not be more than rated output power of the inverter.
-
Do not spill any liquid on the inverter, or use a damp cloth to wipe the inverter casing. Do not touch the unit’s terminals when running– especially with wet hands, otherwise electric shock injury will occur.
-
If you need to change the working environment, do not do so yourself. It should be done by professionals or with assistance from the supplier/local dealer.
-
The operating environment of the inverter should be well-ventilated. Temperature range is
– 4 to 113°F. Keep away from fuel sources and direct sunlight. Do not run in humid or dusty environments. During operation, high temperatures are normal. To maintain proper ventilation, please keep a clean environment around the unit. Do not allow any vents be blocked. -
Keep children away from this unit at all times. It is not a toy. Serious injury or death could occur.
-
Confirm if the inverter can be connected with existing wiring. The AWG rating should be
sufficient for the loads that will be ran. -
Do not open the inverter under any circumstances. Besides voiding the warranty, you are risking severe electric shock to yourself and others around you.
Product Overview
Introduction
ExpertPower Inverter-Charger
The inverter is pure sine-wave with an on-board intelligence system that
handles most of the heavy lifting within your electrical system. The inverter
converts 12 volt direct current (VDC) into 110 volt alternating current (VAC),
or more commonly, the power you utilize at home through your wall outlets. A
typical solar power system consists of a solar panel, solar charge controller,
inverter, battery, and components such as fuses and breakers. The inverter can
be used WITH OR WITHOUT solar meaning you can depend solely on shore-power for
maintaining the battery bank during charging and/or use.Core advantages of the
inverter:
- CPU intelligent management
- Latest American technical inverter
- Best electric components
- High conversion efficiency( 90%~99%)
- Low power consumption,1W~6W under sleep state
Applications
Home Power Tools| Circular saws, drills, grinders, sanders, buffers,
weed and hedge trimmers, air compressors
---|---
Office Equipment| Computers, printers, monitors, scanners
Household Items| Vacuum cleaners, fans, fluorescent and incandescent
lights, shavers, sewing machines
Kitchen Appliances| Coffee makers, blenders, ice markers, toasters
Industrial Equipment| Metal halide lamp, high – pressure sodium lamp
Home Entertainment| Television, VCRs, video games, stereos, musical
instruments, satellite equipment
Diagram
Technical Specs
Utility Model Specifications
| AC110V
---|---
Efficiency| ≥98%
Input Wave Type| Pure Sine Wave
Input Voltage Range| AC 75V~135V
Nominal Input Voltage| 110Vac
Low Voltage shutoff| 92Vac±4%
Low Voltage Recovery| 97Vac ±4%
Over voltage Shut off| 127Vac±4%
Over Voltage Recovery| 122Vac±4%
Nominal Input Frequency| 50Hz/60Hz (auto detect)
Output Wave Type| Pure Sine Wave
Transfer Time (AC to DC)| <5ms
Transfer Time (DC to AC)| <5ms
Inverter Mode Specification
Power Factor | 1 (Sufficient output power) |
---|---|
Rated Output Voltage (V) | 110Vac |
Nominal Output Frequency (Hz) | 50/60 ± 0.3Hz |
Output Voltage Range | ±10% rms |
Efficiency | >90% DC24V |
Overload Protection
| (110%<load<125%) ±10%: Shutdown after 15 minutes; (125%<load<150%) ±10%: Shutdown after 60s;
Load>150% ±10%: Shutdown after 20s
Low Battery Alarm| 21.0Vdc ± 0.6Vdc (24V Input)
Low DC input voltage automatic shut-down| 20.0Vdc ± 0.6Vdc (24V Input)
High DC input voltage warning, then shut down| ****
32Vdc ± 0.6Vdc (24V Input)
High DC input voltage Recover| 31.0Vdc ± 0.6Vdc (24V Input)
Power-saving mode| ≦10W
Power saving on| 20W~60W
Safety| CE / EMC
Communication port| RS232
Cooling| Variable Fan According to Temperature
Operating Temperature Range| 32°F to 140°F
Storage temperature| 5°F ~ 140°F
Humidity| 5% to 95%
Noise| Max 60dB
AC/DC Operation
Basic Connection
This inverter charger is an essential part of any electrical system in an RV
or camper. It’s vital that the inverter works in unison with the rest of your
system without conflict. Below is a typical example of what the electrical
system is like. Shore power flows through the inverter-charger to provide AC
power guarded by breakers or fuses while charging the battery bank. The same
concept applies while under battery power, as the inverter will be powered by
DC (battery) and then converted to AC while protected with battery specific
fuses and breakers. The battery can be charged utilizing solar panels that
flow into a solar charger controller to provide usable power.
Auto Transfer Switch Priority Mode
Priority Mode Selection (select on the front panel
When set to AC priority, you will draw from shore power and not the battery bank. When not connected to shore power, DC power from the battery bank/solar will be converted into AC.
- When shore power is connected, it will be utilized over the battery bank to power the inverter while simultaneously charging the battery bank. Charging can be turned off by setting Battery Type switch to 0. (See page 10)
- When shore power is disconnected, the inverter automatically switches to solar/battery bank power in 5ms.
- When shore power is restored, the inverter will automatically switch the power source from battery bank to shore power in 5 ms.
DC Priority
When set to DC priority, the inverter will utilize the battery bank for electricity. When battery voltage gets too low, it will automatically switch to shore power. Charging can be turned off by setting battery switch to 0. (See Page 10)
- AC and DC loads will be powered by the battery with the inverter if battery voltage is higher than 22V.
- When battery voltage drops below 22V, the inverter automatically switches to shore power (if connected) and charges the batteries.
- When battery is charged to 27V, the inverter will automatically switch back to battery power.
- When shore power is not detectable and battery voltage is lower than 20V, the inverter will shut down. When shore power is detected again, the inverter will turn on automatically and switch to shore power and charge the battery or when battery is charged to 24V (solar), inverter will automatically turn on and switch to battery power.
Power Saver Mode (On/Off Switch)
The power saver function is designed to conserve battery power when there is
no load. Power consumption drops to 1-6W while idle. Once a load larger than
30W is detected, the inverter will automatically begin operation. When the
load is disconnected or drops below 30W, the system will again enter power
save mode.
Charger
Information Table
Top Panel Settings
Panel Overview
POWER SAVING ON | P-Save LED lights GREEN (power saver ≤ load 30W) |
---|---|
SHORE POWER ON | AC LED lights GREEN |
INV (Inverter) | INVERTER LED lights up YELLOW to indicate it’s on. |
CH (Charger) | CH LED lights GREEN for bulk/float charging |
ALARM | Alarm LED lights up RED |
BAT Type | Battery Type 1-9 Selector |
SW
(Working Mode)
| Frequency Selection| Adjust frequency between “50Hz” and “60Hz”
AC/DC
Switch
| Adjust the AC/DC power priority
Next Page| Move to the next page in the information panel
Battery Type Selections and SW Switch
Different kinds of batteries have varying charging voltages. In order to
protect your batteries, our inverter is designed to be suitable for a variety
of different types of batteries. On the top of the inverter, you can choose
the correct voltage specific to your needs using the BAT Type Dial and the
Gear Set Table below to ensure that your battery is with in optimal condition.
Wiring Guide
WARNING:
The output voltage of this unit must never be connected in its input AC
terminal, overload or damage may result. Always switch on the inverter before
plugging in any appliance.
AC Wiring Connection
120V Single Phase
We recommend using 10-12AWG wire to connect to the AC terminal block. There
is only one way of connecting and wiring the terminal block. All of the
wirings are CE compliant. Please contact our technical support team if you are
not sure about how to wire any part of your inverter.
DC Wiring Connection
Cable Type Selections
It is suggested the battery bank be kept as close as possible to the
inverter. The following table is a suggested wiring guide for a 1 meter cable.
In case of wiring longer than 1m, please increase the cross section of cable
to reduce the loss.
Watt Model
|
Battery Voltage
| Wire Gauge / Min|
Watt Model
|
Battery Voltage
| Wire Gauge / Min
---|---|---|---|---|---
0~1.0m| 1.0~5.0m| 0~1.0m| 1.0~5.0m
3000| 24 Vdc| 60mm2| 75mm2| 5000| 24 Vdc| 90mm2| 120mm2
- Please note that if there is a problem obtaining for example 90mm˝ cable, use 250mm˝ or 335mm˝.
- One cable is always best, but cable is simply copper and all you require is the copper, so it does not matter if it is one cable or 10 cables as long as the square area adds up. Performance of any product can be improved by thicker cable and shorter runs, so if in doubt round up and keep the length as short as possible.
Alarm Control & Behavior
Audible Alarm Protection
Alarm Indicators
Indicator
Battery Voltage Low| Inverter LED lights green and buzzer beeps every 5s
Battery Voltage High| Inverter LED lights green and buzzer beeps every
1s — shuts
down after 60s
Inverter Overload
| 110%< load<125%: No audible alarm for 14 minutes, Begins to beep every second at the start of the 15th minute, and shuts down after 15 minutes.
125% <load<150%: Beeps every 1s, and shuts down after 60s. Load>150%: Beeps every 1s, and shuts down after 20s.
Over-Temperature| Heat sink temp. >105ºC, over temp. red LED Light flashes, beeps
every 1s;
Fan
Protection
Over Temperature Protection| Heat sink temp. 105ºC, (shutdown) after 30
seconds
Back-Feed Protection| Yes
Recover from shutting down for fault| Mode of operation: restart the
machine
LED Indicators & Error Codes
LCD Display
LCD Will Display as Follows:
Error Codes
Fault Status Description:
Fault: TX 0000000 “TX” means the load and inverter do not connect, an internal
line connection failure. For more detailed information on fault status, please
refer to Fault Status Table. The inverter will display “System Normal” when
working.
Fault Status Table:
site | Name |
---|---|
B0 | Communication Failure |
B1 | Battery Voltage |
B2 | Inverter Failure |
B3 | Fan Failure |
B4 | Output Overload |
B5 | Output Short Circuit |
B6 | Battery Failure |
B7 | Battery Over-Voltage |
Troubleshooting for Audible and Visual Indicators
LCD, LED Indicator, & Buzzer Table:
Support:
Please Feel Free to contact us for any questions or support at:
(562) 630 – 3002
support@expertpower.us
Read User Manual Online (PDF format)