GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer User Manual

June 5, 2024
GermAwayUV

Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer and Disinfection System Operation Manual

GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air
Sanitizer - WIFI network

SKU: 201105

The Centurion is a state-of-the-art device utilizing a cross-flow filtration system and UV-C germicidal bulbs to catch and eradicate nearly all viral particles, germs, bacteria, and other contaminants from the air without the risk of UV light exposure to you or your clients. A premiere SMART device, the Centurion offers web enabled application to control,  schedule, and monitor the air in any given space right from your smartphone!

How to Install a Wall Mount

  1. To begin the installation of the wall-mounted Centurion device, determine a space that will fit the length and width of the unit while maintaining access to a power source.  Mount the unit at a minimum of 7 feet/ 2.13 meters above the floor.
  2. Remove the Mounting Plate from the device by locating the two screws on the bottom of the Centurion. Remove these with a Phillips Head screwdriver to free the mounting plate and set screws aside for re-installation later.
  3. Using the Mounting Plate as a template, mark the wall before drilling any holes— make sure to additionally use a level to determine accuracy.
  4.  On the Mounting Plate, there are two protruding tabs—these need to be oriented so they are on top of the plate as it sits on the wall. These tabs will fit into two square holes on the back of the Centurion unit to lock it into place.
  5. Install the Mounting Plate, protruding tabs at the top of the Plate, by using the quarter inch drill bits provided to anchor the plate to the wall.
  6.  Once anchored, use four mounting screws to finish mounting the plate to the wall.
  7. Once the Mounting Plate is secured—hang the Centurion unit on the plate by aligning the tabs with the square holes and letting the Centurion nestle down on the tabs.
  8. Check device stability before releasing it. (Depending on the wall surface, additional mounting anchors may be required.)
  9. Using the two screws removed at the beginning, secure the Centurion to the bottom of the Mounting Plate. They will fit back in the bottom of the unit just as they were when they were removed.

Bulb Installation and Replacement

Step 1: Remove Front Door with the Filter by unscrewing 8 captive screws.
Step 2: Release the bulb from the socket by pushing the red button on bulb the socket. Take out the bulb by sliding away from the socket and releasing the bulb from bulb clips as shown. Repeat the process for all bulbs. Inverse the process for installing the bulbs.
To install lamp carefully and FIRMLY push down into lamp socket until an AUDIBLE CLICK is heard. Repeat the process for all bulbs.

Using the Centurion System

  1. To power on your Centurion device, activate the “ON/OFF” switch on the front of the machine, which will make an audible click when activated.
    Note: The only way to turn the Centurion device off is by physically switching the power button, the remote-controlled “Stop” button is to halt the Centurion’s sanitation cycle.

  2. The display screen will illuminate, allowing you access to 16 control options— switch between these using the “Up” and “Down” arrows on the physical remote.

  3. When the preferred option is selected, use the “Right” or “Left” arrows to change its settings and press “OK”.
    After the initial device is set up, the Centurion can also be controlled using a WIFI-enabled smart device app.

Menu Options Overview:

  1. Motion Clean (ON/OFF)
    Allows you to enable/disable the device’s Motion Clean sensor, which makes the machine kick on and run a 30-minute cycle whenever someone enters the room—ensuring air circulation.

  2. Fan Speed
    Allows you to pick one of four fan speeds: Low, Medium, High, and Maximum. The device defaults to Medium.

  3. Duration
    Controls how long the fan will run (10 min, 15min, 20min, 25min, or 30 min maximum)

  4. Beeper (ON/OFF)
    Controls the Centurion’s audio indicator beeping noises as a user moves between and selects options. Not an indicator of cycle duration or completion.

  5. WIFI control
    Enables/disables the device’s ability to be used by a Smart device. To enable it, select the option and press “Ok” on the remote.

  6. WIFI Setup
    This option sets up your Smart device’s ability to connect with the Centurion and displays the WIFI name, SSID, and a timer countdown. (Before attempting, review the Smart App Setup information.)

  7. 10. UV Bulb Locations and Total Run Time
    Allows the user to locate each bulb—Top Left (TL), Bottom Left (BL), Top Right (TR), Bottom Right (BR)—and see their total run time, as well as reset these times when bulbs are replaced.
    11. Filter Run Time
    Allows the user to see the filter’s run time and reset it upon replacement of the filter.
    12. Bulb Diagnostics
    Shows which bulbs are functioning or damaged.
    13. Machine run time
    Total time the machine has been run.
    14. Serial number
    Displays the device’s serial number.
    15. Firmware software info
    Alerts users of new App updates.
    16. WIFI Info (Connected Network)
    Changes when connected to a network this option will show the IP address, name, and signal strength.

Smart App Setup

To begin the process of equipping your Smart device to operate with the Centurion, you will need to download the CureUV app located in the IOS Marketplace or Google Play  Store.

  1. Download the app by searching “GermAway UV Smart Control” or by scanning the following QR Codes,
    |
    ---|---
    Apple| Android

  2. Open the app and either create an account or log into an existing one.GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer - either create

  3. Once logged in, you will see a “Device Tile View,” if new to the app this space will be blank. To add your Centurion device, click on the drop-down menu at the top right of  the screen and select “Add new device”
    GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air
Sanitizer - logged| GermAwayUV 201105 Centurion
High Occupancy 240 Watt Ultraviolet Air Sanitizer -
logged1
    ---|---

  4. Adding a device will prompt you to sign in to your WIFI network. Enter your information and click “Continue”GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer - WIFI network

  5. On your Centurion device, select WIFI Setup, and click “Ok” to activate. The device will display its WIFI name, SSID, and a connection timer countdown—it will now appear in the App as a device you can connect to.

  6. Connect to the device:
    • Android users will be able to click the device name in the App and it will automatically connect.
    • iPhone users will need to go to their Settings, click on Device WIFI, find, and select the Centurion device.

  7. To check that the device has connected a date and time should appear on the Centurion’s display under WIFI Setup. This means the Centurion is now connected to your device!

This device can now be used by this master account—anyone with the login information can  access the device if it is turned on
Please Note: For Step 8 Hold down on the tile in the tile menu to begin accessing your device!
If you have any questions or concerns please reach out to engineering@cureuv.com

App Control Overview

Quick Control: Allows easy control of the device, including Fan Speed and Sleep Timer. GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet
Air Sanitizer - Fan Speed

Scheduler: Allows weekly scheduling of run times GermAwayUV 201105
Centurion High Occupancy 240 Watt Ultraviolet Air Sanitizer -
scheduling

Motion Clean: Alerts you when the motion sensor goes off, triggering a device run.GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet
Air Sanitizer - sensor

Maintenance: Monitors device bulb and filter equipment and allows for information resetting. Virtual Remote : Mirrors the Physical Remote to let you access the Centurion option panel.

GermAwayUV 201105 Centurion High Occupancy 240 Watt Ultraviolet Air
Sanitizer - Physical Remote

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>