LAB GRUPPEN PD3000 3000 Watt Two Channel Amplifier with Precise Power Management User Guide
- June 5, 2024
- Lab gruppen
Table of Contents
Quick Start Guide
PD3000
3000 Watt Two Channel Amplifier with Precise Power Management
Important Safety Instructions
Terminals marked with this symbol carry an electrical current of
sufficient magnitude to constitute a risk of electric shock.
Use only high-quality professional speaker cables with ¼” TS or twist-locking
plugs pre-installed. All other installations or modifications should be
performed only by qualified personnel.
This symbol, wherever it appears, alerts you to the presence of
uninsulated dangerous voltage inside the enclosure – voltage that may be
sufficient to constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and
maintenance instructions in the accompanying literature. Please read the
manual.
Caution
To reduce the risk of electric shock, do notremove the top cover (or the rear
section).
No user-serviceable parts inside. Refer servicing to qualified personnel.
Caution
To reduce the risk of fire or electric shock do not expose this appliance to
rain and
moisture. The apparatus shall not be exposed to dripping or splashing liquids
and no objects filled with liquids, such as vases, shall be placed on the
apparatus.
Caution
These service instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than
that contained in the operation instructions. Repairs have to be performed by
qualified service personnel.
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Use only attachments/accessories specified by the manufacturer.
-
**** Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. -
The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
-
Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
-
Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste, according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection center licensed for the recycling of waste electrical and electronic equipment (EEE). The mishandling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information about where you can take your waste equipment for recycling, please contact your local city office or your household waste collection service.
-
Do not install in a confined space, such as a bookcase or similar unit.
-
Do not place naked flame sources, such as lighted candles, on the apparatus.
-
Please keep the environmental aspects of battery disposal in mind. Batteries must be disposed of at a battery collection point.
-
This apparatus may be used in tropical and moderate climates up to 45°C.
LEGAL DISCLAIMER
Music Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly on or in part upon any description, photograph, or statement contained herein. Technical specifications, appearances, and other information are subject to change without notice. All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Aston Microphones, and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © Music Tribe Global Brands Ltd. 2021 All rights reserved.
LIMITED WARRANTY
For the applicable warranty terms and conditions and additional information regarding Music Tribe’s Limited Warranty, please see complete details online at community.musictribe.com/pages/support#warranty.
Introduction
1.1 Welcome
Thank you for choosing a Lab.Gruppen PD3000. This manual provides a
comprehensive guide to the features and functionality of the PD3000 amplifier.
We highly recommend you read through this manual in its entirety to become
fully acquainted with configuration options and protection circuitry. As you
become thoroughly familiar with all aspects of operation, you may learn of
features or options that will affect your choices of amplifier modes or
loudspeaker system configuration. Lab. Gruppen PD3000 power amplifiers are
designed and built with competitive prices and good performance and protection
features in mind. Although the PD3000 amplifier features a competitive price,
each amplifier draws on the engineering that has made Lab. Gruppen is the
benchmark of quality for touring concert systems: exceptional sonic
performance, rugged construction, proven reliability, and protection features
that anticipate every unwelcome possibility – that is the core of the “show
must go on” design philosophy that every Lab. Gruppen product is created
with, with a well-matched feature set per product range depending on the
expected application.
1.2 Features
Your new PD3000 amplifier incorporates a number of sophisticated technologies
– many of them proprietary to Lab. Gruppen – that ensures the best possible
performance and years of reliable operation. Familiarizing yourself with these
technologies will prove invaluable in setting up and optimizing your
loudspeaker system.
1.3 Class D output stage
PD3000 amplifiers employ our unique IDEEA Class D output stage that is ideally
matched to the rated power output. To provide flexibility, each channel offers
sufficient voltage swing and current capacity to drive loads in any impedance
without any additional configuration. In order to have low thermal losses as
well as a high voltage swing, the design is based on a permanently bridged
output.
1.4 Protection and performance optimization
Appropriate and reliable power amplification is vital to any audio system.
Inadequate or faulty power amplifiers could cause damage to loudspeakers, or
in some cases to the power amplifiers themselves. To prevent damage or service
interruptions, PD3000 amplifiers offer advanced features to protect both
internal circuits and connected loads. These features are part of the Lab.
Gruppen’s “Show must go on” philosophy.
PD3000 protection features include:
- CPL (Current Peak Limiter) ensures that the amplifier’s output does not exceed the safe current handling parameters of the amplifier components.
- Temperature protection ensures that the amplifier will not be damaged by exceeding thermal limits. The RDY LED flashes orange when the amplifier approaches thermal limits to allow user action before protective muting engages.
- DC protection ensures destructive DC signals will not appear at the amplifier outputs. If such conditions occur an internal fuse opens.
- RSL (Rail Sensing Limiter) is applied to avoid distortion at the selected voltage limit threshold and to avoid hitting the rail if it has sagged below the configured threshold. Limiting also may be applied when maximum output current has been reached or when the mains voltage is too low to maintain the required rail voltage. Limiting activity is shown by the front panel Limiter LED
1.5 Unpacking and visual checks
Every Lab. Gruppen amplifier is carefully tested and inspected before leaving
the factory and should arrive in perfect condition. If any damage is
discovered, please notify the shipping carrier immediately.
Save the packing materials for the carrier’s inspection and for any future
shipping.
1.6 Cooling
PD3000 amplifiers use a forced-air cooling system with front to rear airflow,
allowing high continuous power levels without thermal problems.
Please ensure that there is sufficient space in the front and rear of each
amplifier to allow free flow of air, no doors or covers should be mounted
either in the front or the rear of the amplifiers.
Amplifiers may be stacked directly on top of each other with no spacing,
though some spacing may enable more convenient installation of rear cabling.
Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure
effective air circulation. Leaving gaps in between items of equipment degrades
the effectiveness of forced-air cooling.
1.7 Operating voltage
Always connect your PD amplifier to the voltage specified on the rear of the
device. Connecting the amp to an incorrect voltage can permanently damage your
amp.
- USA / Canada / Japan = 100-120 V~, 50/60 Hz
- UK / Australia / Europe / Korea / China 220-240 V~, 50/60 Hz
The locking IEC receptacle on the rear panel accepts the supplied IEC cord which terminates in a connector appropriate for the country of sale.
Control
2.1 Front Panel
The following indicators and controls are available on the front panel (Fig.
1):
-
CH A/CH B CONTROLS adjust the input level. To increase signal gain, rotate the knobs clockwise; to reduce the gain, rotate the knobs counter-clockwise.
-
RDY, SIGNAL, and LIM LEDs display the signal level and system status for each channel. RDY LED lights to indicate that the amplifier is powered on. The SIGNAL LEDs light to show the input signal level. The LIM LED lights when the input signal exceeds an optimum level and activates the internal limiter. Reduce the input gain if the red LIM LED lights up continuously.
-
The POWER button turns the unit off and on.
-
RACK EARS secure the unit into a rack using four attaching screws and washers (fasteners not included). Requires two rack units.
2.2 Rear Panel
The following connectors are available on the rear panel (Fig. 2): -
BREAKER (automated fuse) acts in place of common discardable fuses. After eliminating the cause of faulty operation, simply depress the BREAKER and power up the unit again. The BREAKER acts in place of common discardable fuses.
BREAKER WARNING : Take the following actions BEFORE resetting the breaker:
• Unplug the AC main cable
• Move the POWER switch to the “OFF” position
• Turn all input gain control elements down
• And then, reset the breaker, connect the unit to the mains, switch ON and slowly increase the gain to the target volume -
POWER SOURCE jack accepts the included IEC power cable.
-
SPEAKER OUTPUTS connect the amplifier to the speakers using professional speaker cables with twist-locking speakON plugs. Both output channels are available by using a 4-pole connector and cable with the CHANNEL A output. CHANNEL B is available separately on the right-hand CHANNEL B output.
WARNING! Bridge Mode is not supported!
WARNING! Do not connect any output connector poles to the ground! -
VENTILATION FAN speed adjusts automatically depending on the temperature to ensure trouble-free operation.
-
BALANCED INPUTS (¼” connections) accept audio inputs for each channel from audio cables with ¼” TRS connectors (balanced) or ¼” TS connectors (unbalanced).
BALANCED INPUTS (XLR connections) accept balanced audio inputs for each channel from audio cables with XLR connectors.
NOTE: The XLR and ¼” connections in the BALANCED INPUTS section are physically linked, and users can use this physical connection to route a copy of the input
signal to an additional amplifier. For example, a signal coming into Channel A through the XLR connection can be split and routed back out over Channel A’s ¼”
TRS connection. -
XOVER switch chooses between three crossover modes: FULL RANGE, LF (low-frequency crossover), and HF (high-frequency crossover). In LF mode, the unit amplifies only the low frequencies below 100 Hz. In HF mode, the unit only amplifies the high frequencies above 100 Hz. LF and HF modes are typically used in bi-amping applications.
-
MODE switch selects between MONO and STEREO operation modes:
• Stereo: Inputs A and B are amplified individually and are separately available on SPEAKER OUTPUTS A and B.
• Mono: Input A is amplified and available on both SPEAKER OUTPUTS A and B. Input B is disabled.
NOTE: Attenuation of SPEAKER OUTPUTS A and B is individual in both modes on the front panel through the CH A/CH B attenuation knobs.
Installation
3.1 Rack mounting
Your PD amplifier fits into a 19″ rack and requires two rack units. Install
into the rack using four attaching screws and washers for the front panel.
Consider reinforcing the back panel using rack accessories (supplied with
rack), especially if you will be taking the PD on the road. Make sure enough
cool air reaches the rack, especially when other rack equipment emanates a lot
of heat. The PD amplifiers circulate heat from the front to the rear vents to
relieve heat inside the rack enclosure. If you are installing multiple power
amplifiers into a 19″ rack, add filled panels in the empty rack spaces to
avoid the circulation of hot air.
Fan speed adjusts automatically to assure safe operation. Never block
ventilation openings. Should internal temperature reach extreme values, the
unit will shut down automatically, and resume operation when cooled down.
3.2 Connections
Audio inputs
Each channel input uses either XLR or ¼” jacks. The XLR jacks can accept
balanced XLR connections, while the ¼” jacks can accept both balanced ¼” TRS
connectors and unbalanced ¼” TS connectors. To deploy XLR connectors for
unbalanced signals, bridge pins 1 and 3; mono ¼” TS connectors do not require
any alteration to carry unbalanced signals.
When working with balanced signals, please make sure to exclusively use
balanced cables.
One unbalanced cable in the signal chain can change a balanced signal into an
unbalanced signal.
| |
---|---|---
Outputs Your PD amplifier requires speakON twist-locking professional speaker
connectors. These professional speaker connectors were developed especially
for driving high-powered speakers. The connectors snap in securely, prevent
electric shock, and ensure correct polarity.
The CHANNEL A output contains output pins for both CHANNEL A (1+/1-) and
CHANNEL B (2+/2-), so that both channels if desired, can be sent out
simultaneously on a single 4-pole speaker cable. The CHANNEL B output, on the
other hand, has pinouts for CHANNEL B only (1+/1-).
• Whenever possible, use thick and short speaker cables to minimize power
loss.
Maximum recommended cable length for
Cable Size | 7 ohm | 4 ohm | If ohm |
---|---|---|---|
Avg | mm2 | meter | feet |
12 | 2.0 | 9 | 30 |
10 | 2.6 | IS | 50 |
3.3 Connecting to mains
Always connect your PD amplifier to the voltage specified on the rear of the
device. Connecting the amp to an incorrect voltage can permanently damage your
amp.
Before powering up the amplifier, double-check all connections and fully lower
the gain setting.
Applications
Bi-amping splits a signal into upper and lower frequency bands and then
assigns each frequency band to separate speaker cabinets. A subwoofer
typically takes the low-frequency range. By splitting the signal this way, the
speakers work more efficiently, and you can achieve a cleaner overall sound.
One side sub and linked passive top, Turbosound NuQ102 and NuQ118B together
with Lab.Gruppen PD3000
Specifications
General
Number of amplifier channels | 2 |
---|---|
Peak total output all channels driven | 3000 W |
Peak output voltage per channel | 115 V |
Peak output current per channel | 32 A |
Bridge mode | No |
Output circuit type | Class-D |
Amplifier Outputs
Max Output Power
All channels driven|
---|---
2 Ω per channel, stereo| 1000 W
4 Ω per channel, stereo| 1500 W
8 Ω per channel, stereo| 800 W
Audio Performance
THD+N 20 Hz – 20 kHz @ 1 W | < 0.1% |
---|---|
THD+N @ 1kHz, 1 dB below clip | < 0.1% |
Signal-to-noise | >90 dB |
Channel separation (Crosstalk) @ 1 kHz | >75 dB |
Frequency response | 10 Hz to 20 kHz, +0.5/ -1 dB |
Input impedance | 10 kΩ unbalanced, 20 kΩ balanced |
Distortion,1/8 rated power | < 0.1% |
System
Controls
Front | Power switch Gain controls (channels A and B) |
---|---|
Rear | Stereo/mono, switchable Xover: LF / full range / HF, switchable |
Crossover frequency | 100 Hz |
Indicators | |
Power | RDY LEDs lit green |
Limit, per channel | LIM LEDs lit red |
Signal, per channel | -30 dB, -24 dB, -18 dB, -12 dB, -9 dB, -6 dB, -3 dB, LEDs |
lit green/orange
Thermal Warning, per channel| RDY LED blinks orange
Thermal Warning 90%, PSU| Both RDY LEDs blink orange
Thermal fault, per channel| RDY LED blinks red
Thermal fault 100%, PSU| Both RDY LEDs blink red
Fault, channel| RDY LED-lit constantly red
Fault, device| Both RDY LEDs constantly lit red
Connectors
Connectors|
---|---
Inputs / link| 2 x XLR
2 x ¼” TRS
Outputs| Neutrik speakON (2 x NLT4)
Mains connector| Locking IEC appliance inlet, C14
Protection Features|
Cooling| Two fans front-to-rear airflow, temperature controller speed
Amplifier protection| Thermal and DC protection, Rail sensing, and peak
current limiting.
Load protection| Controlled start and shutdown, behavior, DC-fault protection,
Short-circuit protection
Power Supply
Voltage| Separate 230 V and 115 V versions are available. Not selectable on
the product.
---|---
USA / Canada / Japan| 100-120 V, 50/60 Hz
UK / Australia / Europé / Korea / China| 220-240 V, 50/60 Hz
Power consumption @ 4 ohms| 1050 W
Dimensions / Weight
Dimensions (H x W x D) | 93 x 483 x 326 mm (3.7 x 19 x 12.8″) |
---|---|
Weight | 6.5 kg (14.3 lbs) |
Finish | Black painted aluminum chassis and grey front |
Approvals | CE, cTUVus, PSE, RCM, CCC, FCC |
Other important information
- Register online. Please register your new Music Tribe equipment right after you purchase it by visiting musictribe.com. Registering your purchase using our simple online form helps us to process your repair claims more quickly and efficiently. Also, read the terms and conditions of our warranty, if applicable.
- Malfunction. Should your Music Tribe Authorized Reseller not be located in your vicinity, you may contact the Music Tribe Authorized Fulfiller for your country is listed under “Support” at musictribe.com. Should your country not be listed, please check if your problem can be dealt with by our “Online Support” which may also be found under “Support” at musictribe.com. Alternatively, please submit an online warranty claim at musictribe.com BEFORE returning the product.
- Power Connections. Before plugging the unit into a power socket, please make sure you are using the correct mains voltage for your particular model. Faulty fuses must be replaced with fuses of the same type and rating without exception.
FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION
Lab Gruppen
PD3000
Responsible Party Name: Music Tribe Commercial NV Inc.
Address: 122 E. 42nd St.1, 8th Floor NY, NY 10168, United States
Email Address: legal@musictribe.com
PD3000
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Suppose this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. In that case, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Important information:
Changes or modifications to the equipment not expressly approved by MUSIC
Tribe can void the user’s authority to use the equipment.
Hereby, Music Tribe declares that this product is in compliance with
Directive 2014/35/EU, Directive 2014/30/EU, Directive 2011/65/EU, and
Amendment 2015/863/EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC
and
Directive 1907/2006/EC.
The full text of the EU DoC is available at
https://community.musictribe.com/
EU Representative: Music Tribe Brands DK A/S
Address: Gammel Strand 44, DK-1202 København K, Denmark
UK Representative: Music Tribe Brands UK Ltd.
Address: 6 Lloyds Avenue, Unit 4CL London EC3N 3AX, United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>