WOLPERTECH WT – GP 600 K Garden Water Pump Instructions

June 3, 2024
WOLPERTECH

WOLPERTECH Logo Translation of the original instructions

WT – GP 600 K Garden Water Pump

WOLPERTECH WT GP 600 K Garden Water Pump - Fig

**** Please read the instructions carefully before starting the machine.

STARTING-UP THE MACHINE
DELIVERED ITEMS
WOLPERTECH WT GP 600 K Garden Water Pump - Fig

Starting-up the machine

**

WOLPERTECH WT GP 600 K Garden Water Pump - Fig
1Service connection
**

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 2

Engine protection

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 3WOLPERTECH WT GP 600 K
Garden Water Pump - Fig 3

The pump must not in any case run without fillings.

Operation

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 4

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 5

WOLPERTECH WT GP 600 K Garden Water Pump - Fig6

Cleaning / Maintenance

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 7

WOLPERTECH WT GP 600 K Garden Water Pump - Fig 8

Technical Data

| Garden pump
WT – GP 600 K| WT – GP 1000 I| Domestic water supply unit
T – HW 600 K| WT – HW 1000 II
---|---|---|---|---
Art. No| 3015| 3016| 3017| 3018
Service connection| 230 V~50Hz| 230 V~50Hz| 230 V~50Hz| 230 V~50Hz
Rated input| 600 W| 1000 W| 600 W| 1000 W
 Max. suction head| 7 m| 8 m| 7 m| 8 m
Max. head of delivery| 35 m| 44 m| 35 m| 44 m
Max. delivered quantity| 2800 l/h| 3500 l/h| 2800 l/h| 3500 l/h
tank capacity| –| –| 19 l| 19 l
Max. Water temperature| 35 °C| 35 °C| 35 °C| 35 °C
Degree of protection| IPX4| IPX4| IPX4| IPX4
Weight| 6,7 kg| 7,7 kg| 11, 6 kg| 13,3 kg

**** Read and understand the operating instructions before using the appliance. Familiarise yourself with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. The operator is responsible for accidents or risks to third parties. In case of any doubts about connection and operation refer please to our customer center
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Specified Conditions Of Use

The pump is designed for pumping clean water only to supply the home with water and to use it at home, in the garden, courtyard, and fields. Respecting technical data and safety precautions. Do not use this product in any other way than stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. Do not use the pump at outside temperatures over 40 °C or under 0 °C
The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressure-boosting device.
**** Never use the pump as a pool circulation pump.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information:

  1. Accident site,
  2. Accident type,
  3. Number of injured persons,
  4. Injury type(s)

Symbols

| WARNING/CAUTION!
---|---
**| WARNING – Read the operating instructions to reduce the risk of injury.
| Unplug the machine before any work on it.
| Cable pulling/transport prohibited
| Staying in the transportation medium prohibited
**
| Warning against dangerous electric voltage
| Any damaged or disposed of electric or electronic devices must be delivered to appropriate collection centers.
| CE marking

Safety Instructions

Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid! Unplug the device prior to submersion, upon the termination of operation, in the course of defect removal, and prior to performing maintenance procedures. If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The temperature of the drained liquid must not exceed +35 °C. The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. If the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. The user is responsible to third parties if a pump (dumping stations, etc.) is used. Check the cable and/or socket for damages before the appliance putting into operation. Do not expose the appliance to rain and do not use it in wet or moisture conditions. Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)! When using the pump for domestic water supply, always observe the local regulations of water management authorities and wastewater drainage. In cold weather, the pumping body motor should not be wrapped in a blanket or another piece of textile with the intent to prevent the water from freezing.

Mains Connection

** Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
WARNING!** Electric shock! There is a risk of an injury caused by electric shock!

Before putting it into operation, a qualified electrician must check whether the electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket. Check the voltage. Technical data given on the type label must correspond with the electric network voltage. It is necessary to make sure the connecting socket was not near water and humidity and that the plug was protected against humidity. Only use splash-proof extension cables approved for outdoor purposes. Protect the feeder cable from excessive temperatures, oil, and sharp edges.

Maintenance

**** Unplug the machine before any work on it.

Before using the appliance, perform a visual inspection at all times to make sure the power cord and the plug, in particular, are not damaged on the charger. The appliance must not be used if damaged or if safety equipment is defective. Replace any worn-out and damaged parts. Caution! If the power cord of the appliance gets damaged, it must be replaced by the manufacturer or its customer service or a similarly qualified person to avoid danger. Repairs and works specified in these Instructions may only be performed by qualified authorized staff. Use only original accessories and original spare parts. Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries. To ensure the long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals. During winter storage, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with the appropriate oil (for example, vegetable oil). If necessary, a list of spare parts can be found at www.guede.com.
Guarantee
Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by a material defect or manufacturing defect. Original payment voucher with the date of the sales needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, or damage as a result of any unauthorized interference caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee. The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases: Unprofessional repairs executed by unauthorized service centres;

  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Important information for the customer
Please be sure to know that returning the product  in or after the warranty period must be made in the original packaging.

Service
Do you have any technical questions? Do you have a complaint? Do you require spare parts or an operating manual? You can get quick and unbureaucratic assistance in the Service section on the homepage of our service partner Güde GmbH & Co. KG (www. guede.com). Please help us to help you. In order to be able to identify your device in the case of a complaint, our service partner will require its serial number, article number, and year of manufacture. All this information can be found on the nameplate.

Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail:  support@ts.guede.com

Inspection and maintenance plan

Time interval Description Any other details
As needed Clean the check valve and the prefilter. Check the check valve

function.

Failure removal

Failures Causes Removal
Engine does not start No power supply. Blocked pump wheel Turn the engine

shaft with a screwdriver through the fan
cover (to release  friction circles sealing that may be stuck
together).
The pump does not suck| Missing, loose or blocked check valve is not in water.
No water in the pump shell. Too high suction head. Air bubbles in the suction pipeline. Connections are not sealed, the pump sucks air, the pump is not deaerated. Prefilter clogged| Fix or clean the check valve. Immerse the check valve in water.
Fill the pump shell with water. Check the suction head.
Check the tightening of a suction pipeline. Clean the prefilter.
Thermal detector switching the pump
off| Pump is overheated and switched off by the thermal overloading protection. No electric power supply. Impurity particles (e.g. pebbles) have settled down in the suction hole.| Let the device get cool!  Check the power supply. Disassemble and clean the suction hose, preventing from the suction of foreign substances.
Insufficient amount of
water pumped| Too high suction head. The strainer of the check valve dirty
The water level quickly drops down| Check the suction head. Clean the strainer., Position the check valve
lower. Clean the prefilter. Clean the pump and replace worn parts.
(qualified workshop)
Reduced switching
intervals| Air pressure in the receiver too low| Control air pressure.

Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned appliances correspond – at the type of construction being launched – to the appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us, the Declaration expires.
2006/95/EC
2014/35/EU
(…>20.04.2016)
2009/105/EC
2011/65/EC ROHS
89/686/EEC (PPE)
2006/42/EC
Annex IV
2004/108/EC
2014/30/EU
(…>20.04.2016)
1907/2006/EC
2009/142/EC
1935/2004/EC
EN 60335-1:2012+A11
EN 60335-2-41:2003+A1+A2
EN 62233:2008; AfSP GS 2014:01 Par. 3.1
EN 55014-1:2006+A1+A2
EN 55014-2:1997+A1+A2
EN 61000-3-2:2006+A1+A2
EN 61000-3-3:2013

Notifi ed Body
Name:
Adress:
No:
Harmonised standards used

Wolpertshausen, 14.02.2016

Just in Time GmbH
Birkichstrasse 6
74549 Wolpertshausen
Deutschland    WOLPERTECH LogoTN 3015, 3016, 3017, 3018 2016-03

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals