Congratulations on purchasing this device. This instruction manual is designed to provide you with all required instructions related to the installation, use, and maintenance of the appliance. In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and usage.
The cooker hood uses high-quality materials and is made with a streamlined design. Equipped with a large power electric motor and centrifugal fan, it also provides strong suction power, low noise operation, a non-stick grease filter, and easy assembly installation.
Please note that we are constantly updating our manuals.
Due to continuous development, we reserve the right to make technical changes including errors or other aberrations without notice. This is particularly true for measurements and cut-out dimensions respectively.
Scan the QR code to get access to contact CIARRA Amazon Service if you have any questions. CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet
Hood - qr code

https://www.amazon.com/hz/help/contact/A3RICM3AAIP5MM?marketplaceID=ATVPDKIKX0DER&sellerID=A2HEUF1T5LNA5O&encoding=UTF8&ref=v_sp_contact_seller&

Safety

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • Use this unit only in the manner intended by the manufacturer. If If you have questions, contact the manufacturer at the address or a telephone number listed in the warranty.
  • Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for  Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
  •  Ducted fans must always be vented to the outdoors.
  • Do not use this unit with any additional solid-state speed control device.
  • To reduce the risk of fire, use only metal ductwork.
  • This unit must be grounded.
  • As an alternative, this product may be installed with the approved cord kit designated for the product, following instructions packed with the cord kit. ◼
  • When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  1.  Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
  2. Always turn the hood ON when cooking at high heat or when flam is food.
  3. Clean ventilating fan frequently. Grease should not be allowed to accumulate on fans, filters, or in exhaust ducts.
  4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

*TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:**

  1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
  2. NEVER PICK UP A FLAMING PAN — You may be burned.
  3. DO NOT USE WATER, including wet dishcloths or towels — This could cause a violent steam explosion.
  4. Use an extinguisher ONLY if:
    a) You own a Class ABC extinguisher and you know how to operate it.
    b) The fire is small and contained in the area where it started.
    c) The fire department has been called.
    d) You can fight the fire with your back to an exit.
  • Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

  • For indoor use only
  • For general ventilating use only. Do not use it to exhaust hazardous or explosive materials and vapors.
  • To avoid motor bearing damage and noisy and/or unbalanced fan blade, keep drywall spray, construction dust, etc. off range hood.
  • Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
  • For best capture of cooking fumes, the bottom of the hood MUST NOT BE LESS than 25.6” and at a maximum of 30” above the cooking surface.
  • Always follows the cooking equipment manufacturer’s requirements regarding the ventilation needs.
  • To reduce the risk of fire and to properly exhaust air, be sure to duct air outside — Do not exhaust air into spaces within walls or ceilings or into attics, crawl spaces,s or garages.
  • When installing, servicing, or cleaning the unit, it is recommended to wear safety glasses and gloves
  • Please read the specification label on the product for further information and requirements.

Specifications

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood -
fig

Voltage 110V-120V/60Hz
Power of Motor 1 x 100W
Power of lamps 2 x 3W
Cable length 1.0M
Appliance Dimension 29.7619.683.94(inch)

Note: The manufacturer reserves the right to change any technological improvement or modification without prior notice.

Components

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood -
Components

An Outlet Component
B Outlet Cover
C Hood Body
D Activated Carbon Filterisold separately)
E Grease Filters
F Screws 0.16″.1.18″ 6pcs
G Wall Plug 00.31 x 6pcs

Documentation:
Operation / Installation Manual 1PCS
Installation Diagram(1:1) 1PCS

Installation

Prepare for installation:
a) If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe, or inflammable material with an interior diameter of 4.72”). Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. When possible, use at least 2-foot straight runs before any turns. Larger ductwork may be required for best performance with longer duct runs.

b) Before installation, turn the unit off and unplug it from the outlet.

c) The cooker hood should be placed at a distance of 25.6~30inches above the cooking plane for best effect.

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - LED
Board

d) As for the model with LED Board Backlit, The safety distance between the range hood and the cooking surface is not less than 30 inches to avoid potential safety hazards.

Recommended Tools for Installation

  • Measuring tape
  • Phillips screwdriver no. 2
  • Flat blade screwdriver (to open knockout holes)
  • Drill, 1/8” drill bit, and 1½” hole saw (to mark holes for ducting and cut electrical access hole)
  • Wood shims (2) and wood screws (4) (required for standard installation to the framed cabinet)
  • Saw (to cut holes for ducted application)
  • Sheet metal shears (ducted installation only, for duct adjustment)
  • Pliers (ducted installation only, for duct adjustment)
  • Metal foil duct tape (for ducted applications)
  • Scissors (to cut metal foil duct tape)
  • Pencil
  • Wire stripper
  • Strain relief, 1/2” diameter (to secure house wiring cable to the hood)

CAUTION: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Observe all governing codes and ordinances. Have a qualified technician install the range hood. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The manufacturer declines all responsibility for improper installation and does not accept responsibility for appliance warranty in the event of damage caused by incorrect installation.

Install the Hood:
If present, remove all protective poly film from the hood and/or parts.
This product can be installed in two different ways (Way 1 and Way 2). Below the picture shows the 1:1 hole drawing of different installation methods. CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood -
polyfilm

Way 1:

  1. Install the Outlet Cover on the circular air outlet at the back of the cook hood;CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - Outlet Cover
  2. According to the 1:1 hole drawing of Way1 , Drill four Ø0.31″ holes on the wall, install the wall plug(this step can be ignored if the wall is wooden and instead use screws  to install directly, no need to drill.), insert the upper two wall plugs with 0.16″*1.18″ screws, do not lock too tight them first, and leave a gap of no less than 0.2″;CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - cooker hood
  3. Put the cooker hood onto the top two screws, and lock the self-tapping screws tight;CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - lock too tight
  4. Lock the lower two holes with 0.16″*1.18″ screws.

Way 2:

  1. According to the 1:1 hole drawing of Way 2, mark the following positions with a pencil under the cabinet, and use the drilling tool to open the air pipe hole and power cord hole in turn.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - cabinet
  2. There are 2 methods for ventilation, including “horizontal ventilation” and “vertical ventilation”. Please pay attention to the ventilation method when installation.
    Vertical ventilation: See Pic A, please use the tool to take out the ground cover before using, and the air can be vented from the top;
    Horizontal ventilation: See Pic B, please use the tool to take out the rectangular cover before using it, and the air can be vented from the back.

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood -
Horizontal| CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - Horizontal
1
---|---
3. Install the air outlet assembly on the circular air outlet at the back of the cook hood;CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - outlet assembly 4. Align the air ventilation port of the cooker hood with the cabinet ventilation hole at the bottom, pass the power cord through the power hole, and then use four  .16″*1.18″  screws to lock it into the corresponding position of the pencil marked in the cabinet to fix the cooker hood.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - ventilation port

NOTE:

  • The extensible pipe is an optional accessory, not supplied.
  • Connect ductwork to the hood and use metal foil duct tape to make joints secure and air-tight.
  • Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.

Activated Carbon Filter Installation:

  1. An activated carbon filter can be used to trap odors.
    In order to install the activated carbon filter, the grease filter should be detached first. Press the lock and pull it downward.

  2. Plug the activated carbon filter into the blower as shown and turn it in an anticlockwise direction.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - carbon filter1

  3. Install the grease filter. If replaced, please turn it in a clockwise direction.

NOTE:
➢ Make sure the filter is securely locked. Otherwise, it would loosen and cause danger.
➢ When the activated carbon is installed, the suction of the cooker hood will be reduced.

Air ventilation setting

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - Air
ventilation

  • Outdoor exhausting: Turn the adjuster to the outdoor position, install the outlet, and turn on the cooker hood, then the air will be vented from the outside outlet.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - cooker hood
  • Recycling: the recycling mode with activated carbon filter, Turn the adjuster to indoor position, install the outlet cover, turn on the cooker hood, then the air can be vented from the inside outlet.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - recycling mode

NOTE:

  • The activated carbon filter should be changed every 3 months depending on the conditions of use.
  • The charcoal cannot be washed or recycled, the carbon filter shouldn’t be exposed to heat.

Operation

Always turn your hood on before you begin cooking to establish an airflow in the kitchen.
Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher.

Push-button/Electronic button
Operate the hood as follows:

0 Off button

It’s used for turning off the fan.
Low-Speed button

It’s used for Ventilation in the kitchen. It is suitable for simmering and cooking which do not make much steam.
Medium Speed button

Airflow speed is ideal for ventilation in standard cooking operations.
High-Speed button

When a high density of smoke or steam is produced, press the high-speed button for the highest effective ventilation.
Light button
When lights are OFF, push once on this button to turn ON the lights. Push this button again to turn OFF the lights.

Cleaning and Maintenance

Proper maintenance of the Range Hood will assure the proper performance of the unit.
MOTOR
The motor is permanently lubricated and never needs oiling. If the motor bearings make an excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced.
GREASE FILTERS
The grease filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent.
Discoloration of the filters may occur if using phosphate detergents, or as a result of local water conditions – but this will not affect filter performance. This discoloration is not covered by the warranty. To minimize or prevent discoloration, hand wash filters using a mild detergent.
FAN BLADE
The fan blade should be cleaned frequently. Use a clean cloth soaked with a warm detergent solution.
ACTIVATED CARBON FILTER
The activated carbon filter should be changed every 3 months depending on the conditions of use. Replace more often if your cooking style generates extra grease, such as frying and wok cooking. These filters are not washable and cannot be restored. Refer to installation instructions included with the activated carbon filter.

STAINLESS STEEL CLEANING
Do:

  • Regularly wash with a clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
  • Always clean in the direction of original polish lines.
  • Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
  • You may also use a specialized household stainless steel cleaner.

Don’t:

  • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
  • Use any harsh or abrasive cleansers.
  • Allow dirt to accumulate.
  • Let plaster dust or any other construction residues reach the hood. During construction/ renovation, cover the range hood to make sure no dust sticks to the stainless steel surface.

Avoid when choosing a detergent:

  • Any cleaners that contain bleach will attack stainless steel.
  • Any products containing: chloride, fluoride, iodide, and bromide will deteriorate surfaces rapidly.
  • Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc. , are highly explosive and should never be used close to a range.

PAINTED FINISH CLEANING:
Clean with warm water and mild detergent only. If discoloration occurs, use a finish polish such as automotive polish. (DO NOT use a rough abrasive cleaner or porcelain cleaner.)
LED REPLACEMENT

Circular/ Rectangle LED lamp:

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - LED
lamp

  1. If need to replace the LED lamp, the grease filter should be detached first. Press the lock and pull it downward.CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - grease filter
  2. Push the LED lamp holder out from the cabinet by hand, pull out the LED lamp and the wire together, open the power protection cover, pull out the plug and replace the  LED lamp of the corresponding model.

CIARRA CAS75918A Ductless Range Hood 30 inch Under Cabinet Hood - LED lamp
holder

CAUTION:
Before cleaning or repairing and replacing accessories, please make sure to shut down the power before the operation, so as to avoid electric shock, damage to the human body, and even endanger life safety!

Troubleshooting

Problem Possible Cause Solution
The Extractor hood does not function No electrical supply Check that plug is

connected and the main power switch is turned on
Poor airflow| Grease filters clogged with grease build-up| Clean the grease filters and refit when dry
Charcoal filters clogged with grease build-up| Replace charcoal filters with new sets
Hood suction is not effective| Inadequate ventilation| Ensure that the kitchen is sufficiently ventilated to allow entry of fresh air
Charcoal filters are not installed| Install charcoal filters for setting in recirculation mode
The motor is running but no airflow| Poor exhaust| Please contact CIARRA Customer Care Service
Whirring sound| Foreign objects may be in contact with the fan blade| Please contact CIARRA Customer Care Service
The lights are not working| Light bars are blown out| Replace the damaged light
Light bar connections are loose| Reset the connection

If the problem persists after the above checks, please contact CIARRA Customer Care Centre for assistance.

Environmental protection

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product indicates that this product may not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental regulations for waste disposal.
For more detailed information about the treatment, recovery, and recycling of this product, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. CIARRA -
logo