evolite ArchiTECH 600 60 X 10W RGBW 4-In-1 LED IP65 Projector User Manual

June 5, 2024
evolite

evolite ArchiTECH 600 60 X 10W RGBW 4-In-1 LED IP65 Projector

evolite-
ArchiTECH-600-60-X-10W-RGBW-4-In-1-LED-IP65-Projector-
PRODUCT

User manual

WARNING

  • Before use, and before installing this fixture, read carefully user manual, and follow the safety precautions listed on this page.
  • Very high-level light output. DO NOT LOOK INTO THE BEAM.

DANGER

  • Hazardous voltage. Risk of electric shock!
  • ALWAYS disconnect the fixture from power for servicing, cleaning or installing. Do not connect this unit to a dimmer power pack.
  • Protect the unit from rain or moisture.

WARNING

  • Burn Hazard. Do not touch. Very hot surface
  • The fixture becomes hot during use and remains hot 10 min after use. Do not touch the unit.
  • Fire Hazard!
  • Keep flammable materials away from the fixture.
  • Do not operate the fixture with ambient temperature over 40°C.

DANGER

  • Safety Hazard. Risk of injury.
  • This evolite unit must be installed by professional people. If suspended, make sure the structure and the hardware used for this suspension is secured.
  • This Hardware must support at least 10 times the weight of the device suspended.
  • Ensure public is not looking at the beam. Do not try to repair the fixture by yourself. Contact a professional repair service.

Introduction

Thank you for selecting this professional fixture from evolite This new intelligent Moving Wash will provide you reliability, the latest features, and professional lighting effects for a long period of time. This evolute fixture is complying with European standards.

Device Description

  • Wash LED IP65 projector for outdoor use
  • LED Type: 60pcs ×10W RGBW 4in1
  • Drive Current: 700mA
  • Lifetime: About 80000 hours
  • Channel mode: 5 kinds control channels modes 3CH/6CH/4CH/8CH/11CH
  • Smooth color mix with the latest reflective cup
  • Strobe effect with variable speed
  • Dimmer (0-100%) with 9 different curves
  • Clear display for control panel
  • Powercon power supply connectors IN an OUT
  • Power supply: 110V- 250V / 50-60Hz
  • Power consumption: 600W max
  • Temperature Protection: 65℃
  • Surface Treatment: Aluminium
  • Auto effect: 5 kinds dynamic effects
  • Dimming mode: Dimmer 0 means fast linear dimming. Dimmer 1~8 stands for soft non-linear dimming.
  • Dimensions 557.5 x 125 x 379.5mm
  • NW : 15.3 kg

Installation

Rigging

The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harmful deformation. IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury and or damage to property. The projector had to be installed out of the reach of people.

  • Always secure your fixture with a safety cable!

DMX 512 Connection

The wires must not come into contact with each other, otherwise, the fixture will not work at all or properly. Please note the starting address depends upon which controller is being used. Only use a DMX cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture to another. evolite-ArchiTECH-600-60-X-10W-RGBW-4-In-1-LED-IP65
-Projector-FIG-1

  • Connection with the mains.

The occupation of the connection cables is as followsevolite-
ArchiTECH-600-60-X-10W-RGBW-4-In-1-LED-IP65-Projector-
FIG-2

  • The earth has to be connected. The device must only be connected with an electric installation carried out in compliance with IEC standards.

Set up

Control panel

  • The control board offer several features: you can simple set the starting address, run the pre-programmed program or make a reset.
  • POWER IN/POWER OUT: Power input/output
  • DMX IN/DMX OUT DMX: signal input and output interface.
  • Menu button/return button, enter the menu selection interface or previous menu.
  • The confirmation button is used to confirm the selected function.
  • UpwardUpward/downward select function or Parameter increment / decrement.
NO. Main menu Primary-menu Sub-menu Note

1

|

MENU

|

Dimmer Curve

| Linear| Light intensity increases linearly with DMX value

Exponential

| Light intensity can be finely adjusted at lower DMX values and broadly adjusted at higher DMX values.

Logarithmic

| Light intensity can be broadly adjusted at lower DMX values and finely adjusted at higher DMX values.

S-Curve

| Light intensity can be finely adjusted at lower and higher DMX values and broadly adjusted at medium DMX values.

FAN

| Quiet| Fan off, total power output reduced by 20%.
Studio| Low speed, light output 100 %
Live| High speed, light output 100 %

AUTO

| Temperature control mode, reach 40 °C begin to work
Factory Set| Password| Password is:

UP+UP+DOWN+DOWN+ENTER

2| ADDR| 001~512| DMX address settings
3| DISP| Display orientation settings
4| Dimmer| 0~8| Fine dimming settings

5

|

Mode

| DMX-512| DMX-512 console mode

Static

| RED| 000~255|

Static color settings

GREEN| 000~255
BLUE| 000~255
WHITE| 000~255
Strobe| 000~255

| | AUTO-01|

Auto effect running

---|---|---|---
AUTO-02
AUTO-03
AUTO-04
AUTO-05

6

|

4CH

| RGB-3CH|

DMX channel mode settings

RGB-6CH
RGBW-4CH
RGBW-8CH
HSV-3CH
STAG-11CH

Auto Mode

  • Press the MENU until it shows AUTO.
  • Use the UP/DOWN buttons to set to At1 > At5, Press ENTER to confirm.

DMX Mode

  • DMX mode is selected in the main menu.
  • You can control the projectors individually via your DMX-controller
  • Just select the fixture address, knowing that this address will be the start address. (1st DMX channel).

Note:  If 2 fixtures are addressed with same DMX value, they will move exactly the same way.

DMX Protocol HSV-3CH Mode

Channel Control function Detail description DMX Data

1

| ****

H (Hue)

| NO FUNCTION| 0~0
Red, yellow, green, cyan, blue, purple, red| 1~255
2| S (Saturation)| Saturation dimming from 0~1| 0~255
3| V (Value) (0~100%)| Value dimming from 0~100%| 0~255

DMX Protocol 9 channel RGB-3CH Mode

Channel Control function Detail description DMX Data
1 Red Dimming from 0~100% 0~255
2 Green Dimming from 0~100% 0~255
3 Blue Dimming from 0~100% 0~255

DMX Protocol 6 channel 16bit Mode

Channel Control function Detail description DMX Data
1 Red Dimming from 0~100% 0~255
2 Red 16bit Dimming from 0~100% 0~255
3 Green Dimming from 0~100% 0~255
4 Green 16bit Dimming from 0~100% 0~255
5 Blue Dimming from 0~100% 0~255
6 Blue 16bit Dimming from 0~100% 0~255

DMX Protocol 4 channel RGBW-4CH Mode

Channel Control function Detail description DMX Data
1 Red Dimming from 0~100% 0~255
2 Red 16bit Dimming from 0~100% 0~255
3 Green Dimming from 0~100% 0~255
4 Green 16bit Dimming from 0~100% 0~255
5 Blue Dimming from 0~100% 0~255
6 Blue 16bit Dimming from 0~100% 0~255

DMX Protocol 4 channel RGBW-8CH 16bit Mode

Channel Control function Detail description DMX Data
1 Red Dimming from 0~100% 0~255
2 Red 16bit Dimming from 0~100% 0~255
3 Green Dimming from 0~100% 0~255
4 Green 16bit Dimming from 0~100% 0~255
5 Blue Dimming from 0~100% 0~255
6 Blue 16bit Dimming from 0~100% 0~255
7 Amber Dimming from 0~100% 0~255
8 Amber 16bit Dimming from 0~100% 0~255

DMX Protocol 11 channel STAG-11CH Mode

Channel Control function Detail description DMX Data
1 Overall dimmer Dimming from 0~100% 0~255
2 Red Dimming from 0~100% 0~255
3 Green Dimming from 0~100% 0~255
4 Blue Dimming from 0~100% 0~255
5 White Dimming from 0~100% 0~255

6

| ****

Strobe

| NO FUNCTION| 0~15
From low to fast| 16~214
Random strobe| 215~255




7

| ****



Auto-program effect running

| NO FUNCTION| 0~10
AUTO1| 11~55
AUTO2| 56~100
AUTO3| 101~150
AUTO4| 151~200
AUTO5| 201~255
8| AUTO SPEED| From low to fast| 0~255




























9

| ****





























COLOR MACRO

| NO FUNCTION (0=default)| 0~0
---|---|---|---
Filter 4 (Medium Bastard Amber)| 1~2
Filter 25 (Sunset Red)| 3~4
Filter 19 (Fire)| 5~6
Filter 26 (Bright Red)| 7~8
Filter 58 (Lavender)| 9~10
Filter 68 (Sky Blue)| 11~12
Filter 36 (Medium Pink)| 13~14
Filter 89 (Moss Green)| 15~16
Filter 88 (Lime Green)| 17~18
Filter 90 (Dark Yellow Green)| 19~20
Filter 49 (Medium Purple)| 21~22
Filter 52 (Light Lavender)| 23~24
Filter 102 (Light Amber)| 25~26
Filter 103 (Straw)| 27~28
Filter 140 (Summer Blue)| 29~30
Filter 124 (Dark Green)| 31~32
Filter 106 (Primary Red)| 33~34
Filter 111 (Dark Pink)| 35~36
Filter 115 (Peacock Blue)| 37~38
Filter 126 (Mauve)| 39~40
Filter 117 (Steel Blue)| 41~42
Filter 118 (Light Blue)| 43~44
Filter 122 (Fern Green)| 45~46
Filter 182 (Light Red)| 47~48
Filter 121 (Filter Green)| 49~50
Filter 128 (Bright Pink)| 51~52
Filter 131 (Marine Blue)| 53~54
Filter 132 (Medium Blue)| 55~56
Filter 134 (Golden Amber)| 57~58
Filter 135 (Deep Golden Amber)| 59~60
Filter 136 (Pale Lavender)| 61~62
Filter 137 (Special Lavender)| 63~64
Filter 138 (Pale Green)| 65~66
Filter 798 (Chrysalis Pink)| 67~68
Filter 141 (Bright Blue)| 69~70
Filter 147 (Apricot)| 71~72
Filter 148 (Bright Rose)| 73~74
Filter 152 (Pale Gold)| 75~76
Filter 154 (Pale Rose)| 77~78
Filter 157 (Pink)| 79~80
Filter 143 (Pale Navy Blue)| 81~82
Filter 162 (Bastard Amber)| 83~84

| | Filter 164 (Flame Red)| 85~86
---|---|---|---
Filter 165 (Daylight Blue)| 87~88
Filter 169 (Lilac Tint)| 89~90
Filter 170 (Deep Lavender)| 91~92
Filter 172 (Lagoon Blue)| 93~94
Filter 194 (Surprise Pink)| 95~96
Filter 180 (Dark Lavender)| 97~98
Filter 181 (Congo Blue)| 99~100
Filter 197 (Alice Blue)| 101~102
Filter 201 (Full C.T. Blue)| 103~104
Filter 202 (Half C.T. Blue)| 105~106
Filter 203 (Quarter C.T. Blue)| 107~108
Filter 204 (Full C.T. Orange)| 109~110
Filter 219 (Fluorescent Green)| 111~112
Filter 206 (Quarter C.T. Orange)| 113~114
Filter 247 (Filter Minus Green)| 115~116
Filter 248 (Half Minus Green)| 117~118
Filter 281 (Three Quarter C.T. Blue)| 119~120
Filter 285 (Three Quarter C.T. Orange)| 121~122
Filter 352 (Glacier Blue)| 123~124
Filter 353 (Lighter Blue)| 125~126
Filter 507 (Madge)| 127~128
Filter 778 (Millennium Gold)| 129~130
Filter 793 (Vanity Fair)| 131~132
Invalid (Standby)| 133~255











10

| ****










CCT

| NO FUNCTION| 0~9
2500K| 10~19
2700K| 20~29
3000K| 30~39
3200K| 40~49
3400K| 50~59
3600K| 60~69
3800K| 70~79
4000K| 80~89
4400K| 90~99
4800K| 100~109
5200K| 110~119
5600K| 120~129
6000K| 130~139
6500K| 140~149
7000K| 150~159
7500K| 160~169

| | 8000K| 170~179
---|---|---|---
8500K| 180~189
9000K| 190~199
9500K| 200~209
10000K| 210~255







11

| ****






Dimmer

| NO FUNCTION| 0~9
Dimmer off| 10~34
Dimmer 1| 35~59
Dimmer 2| 60~84
Dimmer 3| 85~109
Dimmer 4| 110~134
Dimmer 5| 135~159
Dimmer 6| 160~184
Dimmer 7| 185~209
Dimmer 8| 210~255

evolite-ArchiTECH-600-60-X-10W-RGBW-4-In-1-LED-IP65-Projector-
FIG-7

Maintenance & service

Cleaning

The cleaning of the internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.

  • Clean with a soft cloth using normal glass cleaning fluid.
  • Always dry the parts carefully.
  • Clean the external optics at least every 20 days.

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:

The fixture does not work, no light

  • Check the connection of power and main fuse.
  • Measure the mains voltage on the main connector.

Not responding to DMX controller

  • DMX LED should be on. If not, check DMX connectors, and cables to see if link properly.
  • If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
  • If you have intermittent DMX signal problems, check the pins on connectors or on the PCB of the fixture or the previous one.
  • Try to use another DMX controller.
  • Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to the DMX interface circuit.

Some fixtures don’t respond to the easy controller

  • You may have a break in the DMX cabling.
  • Check the LED for the response of the master/ slave mode signal.

No response to the sound

  • Make sure the fixture does not receive a DMX signal.
  • Check the microphone to see if it is good by tapping the microphone.

Technical Specifications

Model architect 600
Voltage 110V- 250V / 50-60Hz
Power consumption: 600W
LED 60 pcs 10 Watts RGBW 4in1
Weight 15.3 kg
Dimensions 557.5 x 125 x 379.5mm