HeathZenith 5312 DualBrite Motion Sensor Light Control Instruction Manual

June 5, 2024
HeathZenith

HeathZenith 5312 DualBrite Motion Sensor Light Control

HeathZenith 5312 DualBrite Motion Sensor Light
Control

INTRODUCTION

Models 5312 and 5318

Model 5318 meets the eNerGY STAr® guidelines when DuALBriTe® function is off and ON-TiMe is 1 or 5 minutes and when used with 120 W Max bulbs.

Features

  •  Turns on lighting when motion is detected.
  •  Automatically turns lighting off.
  •  DuALBriTe®
  • Timer.
  •  Photocell keeps the lighting off during daylight hours.
  •  LeD indicates motion was sensed (day or night).

This package includes:

Requirements

  • The light control requires 120-volts AC.
  • if you want to use Manual Mode, the control must be wired through a switch.
  • Some codes require installation by a qualified electrician.
  • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

OPERATION

Mode: On-Time Works: Day Night
Test 5 Seconds x       x
Auto 1, 5, or 20 Min x
Manual To Dawn* x
Accent 3, 6 Hr, to Dawn x

TEST

AUTO

MANUAL MODE

Mode Switching Summary

if you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AuTO mode.

DUALBRITE® Timer

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. if motion is sensed, the light turns on full bright for the ON-TiMe (1, 5, or 20 minutes) then returns to dim mode.

INSTALLATION

  • For easy installation, select an existing light with a wall switch for replacement.
  • For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. NOTE: if fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance

For eave mount only:

Wire the Light Control

  •  remove the existing light fixture.
  •  install the mounting strap as shown using two screws that fit your junction box.
  •  The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
  •  route the light control’s wires through the large gasket holes.
  •  Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

Mount the Light Control

  • Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.
  •  For model SL-5318 only, align the three slots in the decorative shell with the bulb holder pins. Push the shell in and then twist clockwise to lock. repeat for another shell.
  •  Push the rubber plug firmly into place.
  •  if a wet-location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.
  •  Adjust the bulb holders by loosening the lock nuts but do not rotate the bulb holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

TEST AND ADJUSTMENT

  • NOTe: Model 5318 meets the eNerGY STAr® guidelines when DuALBriTe® function is off and ON-TiMe is 1 or 5 minutes and when used with 120 W Max bulbs.

  •  Turn the ranging control to the medium position (halfway between MiN and MAX), DuALBriTe® to OFF, and the ON-TiMe control to the TeST position.

  •  Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

  •  Areas where pets or traffic may trigger the control.

  •  Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

  • NOTE: if the fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

  • The detector is less sensitive to motion directly towards it.

  •  Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

  •  Walk through the coverage area noting where you are when the lights turn on (also,
    the LeD will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1″ (25 mm) away from the bulbs.

  •  Adjust the rANGe as needed.rANGe set too high may increase false triggering.

  •  Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

  •  Set the amount of TiMe you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

  •  Set the DuALBriTe® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn)

SPECIFICATIONS

  • range . . . . . . . . . . . . up to 70 ft. (21 m); 100 ft.
  • (30.5 m) with range Boost. [varies
  • with surrounding temperature]
  • Sensing Angle . . . . . . up to 240°
  • electrical Load . . . . . . up to 300 Watt Maximum Tungsten [up to 150 Watt maximum
  • each bulb holder.]
  • Power requirements . 120 VAC, 60 Hz
  • Operating Modes . . . . TeST, AuTO and MANuAL
  • MODe
  • Time Delay . . . . . . . . 1, 5, 20 minutes
  • DuALBriTe®
  • Timer . . . . 3, 6 hours, Dusk-to-Dawn
  • HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on. 1.    Light switch is turned off.

2.    Flood lamp is loose or burned out.

3.    Fuse is blown or circuit breaker is turned off.

4.    Daylight turn-off is in effect.

5.    incorrect circuit wiring, if this is a new installation.

6.    Light control aimed in wrong direction.

| 1.         Turn light switch on.

2.         Check flood lamp and replace if burned out.

3.         replace fuse or turn circuit breaker on.

4.         recheck after dark.

5.         Verify wiring is correct.

6.         re-aim light control to cover desired area.

Lights come on in day- light.| 1.         Light control may be installed in a relatively dark location.

2.         Light control is in TeST.

| 1.         The fixture is operating normally under these condi- tions.

2.         Set control switch to 1, 5, or 10 minutes.

Lights come on for no apparent reason.| 1.    Light control may be sensing small animals or auto- mobile traffic.

2.    range is set too  high.

3.    DuALBriTe®  timer is on.

| 1.    re-aim light control.


2.    reduce range.

3.    The fixture is operating normally under these condi- tions.

Lights turn off too late in Dusk-to-Dawn setting.| Light control may be installed in a relatively dark loca- tion.| relocate light control, or use 3 hr. or 6 hr. setting.
Lights stay on continu- ously.| 1.         A flood lamp is positioned too close to the light control or pointed at nearby objects that cause heat to trigger the light control.

2.         The light control may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat- reflective surface.

3.         Light control is in manual mode.

| 1.         reposition the flood lamp away from the light control or nearby objects.


2.         reduce range.



3.         Switch light control to AuTO.

Lights flash on and off.| 1.         Heat or light from the flood lamps may be turning the light control on and off.

2.         Heat being reflected from other objects may be turn- ing the light control on and off.

3.         Light control is in the TeST mode and warming up.

4.         Light may be leaking through the flood lamp reflec- tors.

| 1.    reposition the flood lamp away from the light con- trol.

2.    reposition light control.


3.    Flashing is normal under these conditions.

4.    replace the flood lamps with new high quality PAr 38 lamps. (Make sure the metal lamp protectors are installed).

Lights flash once, then stay off in manual mode.| Light control is detecting its own lights.| reposition flood lamps to keep area below the light control relatively dark.

TECHNICAL SERVICE

Please call 1-800-858-8501 (English speaking only) for assistance before returning the product to the store. if you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. if the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write to: Heathcote LLC P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service if contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase

TEN YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or work man ship will be corrected at no charge to you. Not Covered – repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THiS WArrANTY iS eXPreSSLY iN Lieu OF ALL OTHer WArrANTieS, eXPreSS Or iMPLieD, iNCLuDiNG ANY WArrANTY, rePreSeNTATiON Or CONDiTiON OF MerCHANT ABiLiTY Or THA THe PrODuCTS Are FiT FOr ANY PArTiCuLAr PurPOSe Or uSe, AND SPeCiFiCALLY iN Lieu OF ALL SPeCiAL, iNDireCT, iNCiDeNTAL, Or CONSeQueNTiAL DAMAGeS  rePAir Or rePLACeMeNT SHALL Be THe SOLe reMeDY OF THe CuSTOMer AND THere SHALL Be NO LiABiLiTY ON THe PArT OF HeATHCO LLC FOr ANY SPeCiAL, iNDireCT, iNCiDeNTAL, Or CONSeQueNTiAL DAMAGeS, iNCLuDiNG BuT NOT LiMiTeD TO ANY LOSS OF BuSiNeSS Or PrOFiTS, WHeTHer Or NOT FOreSeeABLe.

Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals