Gude 50079 Compressor Air Power Instructions
- June 5, 2024
- Gude
Table of Contents
50079 Compressor Air Power
Instruction Manual
Please read the instructions carefully before starting the machine.
STARTING-UP THE MACHINE
DELIVERED ITEMS
Operation
Cleaning/Maintenance
After approx. 2-4 hours of use, the condensate that has formed must be drained from the receiver.
Technische Daten
Compressor……………………………………………..AIRPOWER 200/08/6
Art. No …………………………………………………………………….50079
Service connection ……………………………230V~50Hz
Motor output S3/25%………………………………..1,1 kW
Idle speed …………………………………………….3400 min -1
Suction capacity ……………………………………200 l/min
Free air delivery……………………………………..148 l/min
Max. working pressure …………………………………8 bar
Max. working pressure …………………………………8 bar
Weight …………………………………………………………… 13 kg
Degree of protection …………………………………………….. IP 20
Protection class ……………………………………………………………….I
Sound power level LWA …………………………………… 97 db(A)
Measured according to 2005/88/EC
Read and understand the operating instructions before using the appliance.
Abide by all the safety measures stated in the service manual. Act responsibly
toward third parties.
In case of any doubts about connection and operation refer please to our
customer center Preserve all the documentation so that anyone who uses the
compressor can consult this beforehand.
Specified Conditions Of Use
The compressor can only be used for the production of compressed air to be
used at home and by handymen. – Respecting technical data and safety
precautions.
The compressed air produced by the compressor can not be used for
pharmaceutical, food, or medical purposes or to fill the air bottles of scuba
divers.
The compressor must be used in a suitable environment (well ventilated
with an ambient temperature of between +5°C and +40°C) and never in places
with dust, acids, vapors, explosive or flammable gases.
Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
Safety instructions
WARNING! Electric shock! There is a risk of an injury caused by
electric shock!
Operation is only allowed with a safety switch against stray current (RCD
max. stray current of 30mA).
Check the voltage. Technical data given on the type label must correspond with
electric network voltage.
Insert the plug of the electrical cable in a socket of suitable shape, voltage
and frequency complying with current regulations.
Use extension cables with a maximum length of 5 meters and with a cable cross-
section of not less than 1.5 mm 2. Use of extension cables of different
lengths and cross-sections and also of adapters and multiple sockets should be
avoided.
Check the cable and/or socket for damages before the appliance putting into
operation.
To avoid danger, a damaged mains supply pipe must be replaced by the
manufacturer. Do not under any circumstances attempt any repair yourself.
Never let the compressor come into contact with water or other liquids and
never direct the jet of liquids sprayed by tools connected to the compressor
towards the compressor: as the appliance is live, this could cause
electrocution or short-circuits. Never use the appliance with bare feet or wet
hands or feet.
Never yank the power cable to disconnect the plug from the power outlet or to
move the compressor. Warning: the compressor may restart when power is
restored following a blackout.
Compressed air is a potentially dangerous form of energy; always take great
care when using the compressor and its accessories.
This device is not intended for use by persons (including children) with
limited physical, sensory or mental capabilities or without the necessary lack
of experience or knowledge unless they are supervised by a person who is
responsible for their safety or was instructed by that person in how to use
the device.
Children should be supervised to ensure that they do not play with the device.
Always keep children and unauthorized persons out of reach of the appliance.
Never use the compressor without being supervised.
Never direct the jet of air towards persons, animals, or your body.
Never keep the airflow in body holes as that could lead to fatal injuries!
Keep the work area free.
When operating, the compressor must be placed on a stable surface.
The compressor must be used in a vertical position only.
Caution! The compressor may only be used with appropriate wheels and rubber
bumps.
Safety goggles should be worn when using the compressor in order to protect
the eyes against any foreign bodies lifted by the jet of air.
If possible, when using air-powered accessories, wear safety clothing.
Always maintain a safe distance of at least 4 meters between the compressor
and the work area.
Caution! The pneumatic hose may lash you when the quick-acting coupling is
opened! The pneumatic hose should be held by hand.
Always use the handle to move the compressor.
When using compressed air, you must know and comply with the safety
precautions to be adopted for each type of application (inflation, air-powered
tools, painting, washing with water-based detergents only, clinching, etc.).
When using compressed air, you must know and comply with the safety
precautions to be adopted for each type of application (inflation, air-powered
tools, painting, washing with water-based detergents only, clinching, etc.).
Caution! Never switch the compressor on or off using the plug. Pressure switch
to be pressed at all times.
Do not leave the compressor on overnight as it could become a source of
danger.
At the end of your working day, switch the appliance off, release the air jet
and unplug the compressor.
Warning: if the water that condenses is not drained, it may corrode the
receiver, reducing its capacity and impairing safety.
As it is a contaminating product, condensate must be DISPOSED of in accordance
with laws on the protection of the environment and current legislation.
Never leave the appliance exposed to adverse weather conditions (rain, sun,
fog, snow).
If this compressor is used outdoors, always remember to stow it after use in a
covered or closed place.
Never use the compressor outdoors in rain or bad weather.
Do not place flammable or nylon/fabric objects close to and/or on the
compressor.
Do not cover the air inlets on the compressor.
The compressor must not be fitted in a vehicle for industrial purposes without
an inspection by an expert!
If the compressor is used for industrial purposes, it must be checked by an
expert before putting into operation for the first time. Such check must be
ordered by the operator (under betrSichV Section 17 No. 25 – operation safety
regulation) Caution!
When fitted in automatic equipment, it is necessary to install an appropriate
alarm or warning device in case of a power outage or malfunction, or
compressor (e.g. feed line, etc.) failure.
To guarantee perfect and reliable operation of the rotary and percussive
pneumatic tools such as impact wrenches, staplers, or nailers, etc., the
compressed air must be supplied filtered – with oil via the lubricator or
maintenance unit A filtered water separator should be used for varnishing in
any case.
To select a suitable pneumatic tool, the tool’s air consumption and the
compressor’s effective amount delivered must necessarily be considered.
(Pneumatic tools and accessory equipment can be found at
www.guede.com)
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before
using the appliance.
qualification: Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance use.
Minimum age: Persons over 16 years of age can only work on the appliance. An
exception includes youngsters trained in order to reach knowledge under the
supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a
professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. For the sake of eventual accident, in
accordance with DIN 13164, a workplace has to be fitted with a first-aid kit.
It is essential to replace any used material in the first-aid kit immediately
after it has been used.
If you seek help, state the following pieces of information:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
Before carrying out any work on the machine, disconnect the plug from the
socket.
Run the accessory connected dry until there is no more air in the receiver.
Prior to every use, visually check the machine to rule out any defects, in
particular on the power cable and the plug.
Safety valve Functional check
The machine must not be used under any circumstances if the machine or the
safety devices are damaged.
Use only original accessories and original spare parts.
Never clean the machine and its components with solvents, flammable or toxic
liquids. Us only a damp cloth making.
Oil-free
No need to add oil to the operation
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
If necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
The guarantee solely covers inadequacies caused by material defects or
manufacturing defects. An original payment voucher with the date of the sale
needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance
overloading, use of violence, or damage as a result of any unauthorized
interference or caused by foreign items. Failing to follow the operating and
assembly instructions and common wear are also not included in the guarantee.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or
operating instructions? We will quickly help you and without needles
bureaucracy at our web pages at www.guede.com in the
Servicing part. Please help us be able to help you.
In order to identify your device in case of a claim, we need the serial No.,
product No. and year of production.
All this data can be found on the type label. Please enter it here for future
reference:
Serial No.:
Art. No:
Year of production:
Symbols
| Read the Operating Instructions!
---|---
| before carrying out any work on the machine, disconnect the plug from the
socket.
| Wear eye protective goggles!
Wear ear protectors!
| Protect against humidity
Never expose the tool to rain.
| Cable pulling/transport prohibited
| Warning/caution!
| Dangerous voltage
| Caution – hot surface!
Warning, hot surfaces!
| Danger – automatic control (closed loop)
| Warning against thrown-off items
| Keep a distance from persons!
Observe to keep out of the dangerous zone
| Any damaged or disposed of electric or electronic devices must be delivered
to appropriate collection centres.
| Protect against humidity
| This side up
EC-Declaration of Conformity
GÜDE GmbH & Co. KG
birkichstrasse 6, 74549 Wolpertshausen Deutschland
We, hereby declare the conception and construction of the below-mentioned
appliances correspond – at
the type of construction being launched – to appropriate basic safety and
hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us, the Declaration
expires.
Compressor AIRPOWER 200/08/6 #50079
Appropriate EU Directives
2006/42 EG, 2004/108 EG, 2000/14 EG
Harmonized standards used
EN 1012:2010
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
A2:2006 + A13:2008 + A14:2010
EN 60204-1:2011
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Failure removal
Defect | Causes | Measure |
---|---|---|
Compressor not starting after being switched on | Pressure in the air jet | |
exceeds the closing pressure | Release the pressure in the air jet so that the |
pressure switch gets automatically switched on
Defective supply| Have the current supply checked by an authorized person
Defective pressure switch| Have the pressure switch replaced by an authorized
person (Güde service center)
Worn carbons| Replace the carbons
After reaching the closed pressure, the compressor runs or buzzes for a short
time and then switches off automatically| Electric cable is too long or its
cross-section is too small| Check the length and cross-section of the electric
cable
Compressor running constantly| The suction filter is very dirty| Clean or
replace the suction filter
Pneumatic tools have a high air consumption| Check the pneumatic tool air
consumption; seek an authorised compressed air dealer
Leaking on the compressor| Localize the leaking, contact the Güde service
center
Compressed-air pipeline leaking| Contact the Güde service center
The drain valve is open or missing| Close or insert the drain valve
The compressor gets started too often| Too much condensate in the air jet|
Drain the condensate
Compressor is overloaded
Safety valve blowing off| Pressure in the air jet exceeds the set cut-off
pressure| Have the pressure switch adjusted/replaced by an authorized person
(Güde service center)
The safety valve is defective| Replace the safety valve or contact the Güde
service center
Compressor getting warm too much| The air supply is not sufficient| Make sure
sufficient air supply and outlet (minimum distance from wall is 40 cm) is
provided
Cooling fins on the cylinder (cylinder head)
are dirty| Clean the cooling fins on the cylinder (cylinder head)
A too long time of appliance operation| Switch the compressor off
The compressor is overheated and keeps switching off| Compressor is
overloaded| Contact the Güde service center
Compressor is defective| Contact the Güde service center
Compressor under undervoltage| Contact the Güde service center
The outdoor temperature of 35°C
GÜDE GmbH & Co. KG
birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>