AEROMIXER Synthetic Pro Edition Nutrient Mixer and Aerator Pump Owner’s Manual

June 5, 2024
AEROMIXER

AEROMIXER Synthetic Pro Edition Nutrient Mixer and Aerator Pump Owner’s Manual
AEROMIXER Synthetic Pro Edition Nutrient Mixer and Aerator
Pump

Remember, Aeromixer is not designed for use in any soft walled or cone bottom tank, and requires a dedicated non-GFCI outlet to function properly.

Stabilizing Foot Installation

Proper foot installation is critical to operate pump properly.
Stabilizing Foot Installation
TOOLS REQUIRED
Stabilizing Foot Installation

Mixing

Maxing Machine

Maxing Machine

TOOLS REQUIRED

Pumping

Screw Attachment A onto your Aeromixer pump. Choose the appropriate fitting for your hose size and screw it onto Attachment A. If necessary, use a hacksaw or similar to modify Attachment B as pictured. Secure using hose clamp.Pumping

TOOLS REQUIRED

Placement

  1. Placement
    Do NOT lower by cord
    Placement

  2. Place both tips of stabilizing foot against sidewall of tank
    Placement
    Aeromixer should sit flat on the bottom of the tank
    Placement

Read this, it’s important!

10 Things you should know

  1. Ensure stabilizing foot screws are tightened all the way before use.
  2. Aeromixer requires a dedicated non-GFCI outlet.
  3. For ease of set up, place your Aeromixer in an empty tank. Ensure that your Aeromixer is placed against the sidewall of your tank, with both tips of the stabilizing foot making contact with the sidewall.
  4. Nutrients should be added slowly when your Aeromixer is running in a full tank of water. No more than 2 pounds of dry nutrients per gallon of water can be added to your mixing tank. (Oversaturation of Nutrients can cause hydrolock and will void warranty of your Aeromixer.)
  5. Never lift your Aeromixer by its air intake hose or by the power cord.
  6. Don’t start your Aeromixer unless it is submerged in at least 5 1/2” of water.
  7. The end of the air intake hose must be out of the tank to inject air. Make sure the air intake hose is not kinked and is clear of debris.
  8. Aeromixer is not designed for continuous use while mixing.
    Recomended run times are as follows: (Please note every tank and environment is different and may require time adjustments. Please contact us if you have any temperature issues.)
    Tank size (Gallons)Time to run AeromixerTime to let tank rest
    **** 50-100 gallons| 15 minutes on| 2 hours off
    ---|---|---
    100-250 gallons| 30 minutes on| 2 hours off
    250-500 gallons| 1 hour on| 2 hours off
    500-1000 gallons| 2 hours on| 2 hours off
    1000-3000 gallons| 4 hours on| 2 hours off
  9. Cleaning your Aeromixer regularly is important. See page 9 for detailed instructions.
  10. Never service or move your Aeromixer while it is plugged

Cleaning

Run your Aeromixer in fresh water after every use for 10-30 seconds to clean residue from your pump. Every so often it’s good to deep clean your Aeromixer, to do so, follow instructions below.
Cleaning
Cleaning
Cleaning
Cleaning

Safety and Specifications

GENERAL SAFETY
See the ::Troubleshooting page: in this manual for information about common Aeromixer problems and remedies.

  1. Know the Aeromixer application, limitations. and potential hazards.
    Do not use in explosive atmosphere. Pump water only with this pump. Failure to follow this warning can result in personal injury and/or property damage.
    Risk of flooding. If flexible discharge hose is used, make sure pump is correctly placed in tank to prevent movement. Failure to correctly place pump may allow pump movement and prevent pump from starting or stopping.

  2. Make certain power source, conforms to requirements of your equipment.

  3. Disconnect power before servicing

  4. Release all pressure within system before servicing any component.

  5. Drain all water from system before servicing.

  6. Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

  7. Check hoses for weak or worn condition before each use, making certain all connections are secure.

  8. Periodically inspect pump and system components. Keep Aeromixer and lank free of debris and foreign objects. Per form routine maintenance as required.

  9. Provide means of pressure relief on pumps hose discharge can be shut-off or obstructed.

  10. Personal Safety:

    • a. Wear safety glasses at all times when working with pumps.
    • b. Keep work area clean, uncluttered, and properly lighted. Put away all unused tools and equipment when finished
    • c. Keep visitors at a safe distance from the work area. d. Make workshop child-proof with padlocks, master switches; and by removing starter keys.
  11. When wiring an electrically driven pump, follow all electrical and safety codes, as well as most recent National Electrical Code (NEC) and Occupational Safety and Health Act (OSHA).
    Pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly.

  12. Risk of electric shock. This equipment is only for use on 115 voll (single phase) and is equipped with an approved 3 conductor cord and 3-prong, grounding-type plug.
    To reduce risk of electric shock, be certain that it is connected to properly grounded, grounding-type receptacle.
    Where a 2-prong wall receptacle is encountered, it must be replaced with properly grounded 3-prong receptacle installed in accordance with the National Electrical Code and local codes and ordinances.

  13. All wiring should be preformed by a qualified electrician.

  14. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.

  15. Use wire of adequate Size to minimize voltage drop at motor. Refer to most recent National Electric Code.

  16. Do not touch an operating motor. Modern motors are designed to operate at high temperatures.

  17. Do not use in water where fish are present.

AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock will cause the pump lo overheat and fail. This pump has an anti-airlock hole in the bottom of the pump body. If you sus-pect an airlock, unplug the pump, clean out the anti-airlock hole with a paper clip or piece of wire, and restart the pump.
IMPORTANT: This hole allows the pump to start priming within 15 seconds in as little as 1/2″ of water. NEVER restart pump in less than 1/2″ of water. Leakage from the anti-airlock hole is normal.

DESCRIPTION
Aeromixer is designed for mixing and aerating nutrient solutions. Pump can he used for sump service and dewatering. Unit is constructed of hi-impact corrosion resistant plastic. Screened inlet prevents large solids from entering pump.
NOTICE: This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.

INSTALLATION
Do not use power cord to lift motor. Always use handle.

  1. Pump should be needs to be correctly placed against the sidewall of any lank, and should rest on a level, solid foundation. Do not suspend pump by means of discharge pipe or power cord. Keep pump inlet screen clear.

  2. Thread outlet pipe into pump body carefully to avoid stripping or crossing threads.

    • a. To install with garden hose, install adapter provided with pump.
      NOTICE: To kelep Motion as low as possible, hose must be 3/4″ or larger. Keep hose as short as possible.

    • b. To install with rigid pipe, use plastic pipe. Wrap thread with teflon tape.

    • c. Power supply: Pump is designed for 115V, 60 HZ operation and requires an individual branch circuit of 15 amperes or more capacity. It is supplied with a 3-wire, cord set with grounding-type plug for use in a 3-wire, grounded outlet. A 3-wire extension cord, of at least 18 AWG size is suggested. with larger sizes for runs over 25ft. For safety. pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or a ground wire system. Do not cut off the round grounding prong.

The pump motor is equipped with automatic reselling thermal protector arid may restart unexpectedly. Protector trip-ping is indication of motor overloading as a result of operating pump at low lift (which will overload the motor), excessively high or low voltage, inadequate wiring, incorrect motor connections, or a defective motor or pump.

Operation

Risk of burns or death from electric shock. Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water. Disconnect power from pump before handling, servicing, or attempting to repair pump.

  1. The pump must be standing in at least 5 1/2” (135mm) of water before starting. The shaft seal is water lubricated and may be damaged if pump runs dry.
  2. After starting, the pump will lower the water level to 3/16” (4.75mm) before losing suction. It will not pick up water less than 3/16” deep when running and will not operate successfully if started in only 3/16” of water.
  3. Do not leave pump unattended! If the pump has been operating satisfactorily and the discharge stream suddenly stops coming out of the hose, stop the pump immediately; do not allow it to run dry. A mop or squeegee will be needed to remove remaining water.
  4. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the overload protector will stop the motor before it is damaged. When the motor has cooled sufficiently, the overload protector will reset itself and the motor will restart.
    NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check it to find the problem. Low voltage, long extension cords, clogged impeller, too much back pressure in the discharge hose (as when pumping through 50’ (15m) of coiled hose), or running pump with no load, can all cause excessive cycling and overheating.

Specification

Model AER050-3000SS
Nominal voltage 115V/60HZ
Output power 3/4 hp
Motor full load 7.1 amps
Protection type IPX8
Max. Height 40ft
Max. Submersion depth 17ft
Max. Conveying amount 4450gph
Max. Fluid temperature 95 F
Diameter of pipe NPT1″ NPT1-112″
NPT1-1/4″ GHT3/4″

Performance

Performance Table

Troubleshooting

Disconnect power from pump before handling, servicing, or attempting to repair pump.

SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Aeromixer isn’t injecting air into the mixing tank. Blocked air hose Check

to make sure the air intake hose isn’t
kinked or plugged, and is NOT submerged.
Aeromixer spins in
circles when it is
turned on.| Stabilizing foot not
installed correctly
Aeromixer not placed
correctly in tank
Tank is dirty/slippery| Please refer to page 2 of this manual for
proper installation.
Please refer to page 6 of this manual for
proper placement.
Clean tank and rinse with fresh water.
Aeromixer won’t start
or run.| Popped circuit
Low line voltage
Defective motor
Impeller stuck| Check breaker box.
If voltage is under recommended minimum,
check size of wiring from main breaker
on property.
Contact Aeromixer, claims@aeromixer.com
If impeller won’t turn, follow cleaning
instructions on page
Aeromixer operates
but delivers little
or no water.| Stabilizing foot not
installed correctly
Low line voltage
Something caught in
impeller
Small diameter hose
or long discharge
line
Air lock
Kinks/bends in hose| Please refer to page 2 of this manual for
proper installation. Ensure that stabilizing
foot screws are fully tightened.
Use only 14 gauge or larger extension cords.
Use short extension cords when necessary.
Clean out impeller.
Use larger diameter garden hose or 1”
flexible pipe. Eliminate any excess hose.
Short hoses work best.
Turn off Aeromixer for a few seconds, clean out anti-airlock hole and restart pump.
Straighten hose.

Don’t see the issue you are having? Check our FAQ page at aeromixer.com or contact us directly at info@aeromixer.com . We are here to help!

Warranty

RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.

LIMITED WARRANTY

Aeromixer warrants to the original consumer purchaser (“Purchaser” or “You”) of its products that they are free from defects in materials and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at Aeromixer’s option, subject to the terms and conditions set forth below. The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of original product- not the date of replacement under warranty. The warranty is limited to repair or replacement of product only- Purchaser pays all removal, installation, labor, shipping, and incidental charges. For parts or troubleshooting assistance, DO NOT return product to your retail store

Claims made under this warranty shall be made by returning the product to Aeromixer INC immediately after the discovery of any alleged defect. Aeromixer will subsequently take corrective action as promptly as reasonably possible. No requests of service will be accepted if received more than 30 days after the warranty expires.

General Terms and Conditions

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following: (1) Acts of God; (2) products which, in Aeromixer’s sole judgment, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use, or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth Aeromixer’s sole obligation and purchaser’s exclusive remedy for defective products

Aeromixer SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYONG THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

Customer Support

Aeromixer INC
Aeromixer.com
Tel: +1 541 690 0888
For additional assistance
or questions, email:
info@aeromixer.com
A Southern Oregon Company
Made in China
2022

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals