AEROMIXER Mix + Aerate with One Pump Owner’s Manual

June 5, 2024
AEROMIXER

AEROMIXER Mix + Aerate with One Pump Owner’s Manual
AEROMIXER Mix + Aerate with One Pump

First thing’s first…

*Remember, Aeromixer is not designed for use in any soŌ walled or cone boƩom tank, and requires a dedicated non-GFCI outlet to funcƟon properly.

Stabilizing Foot Installation

Proper foot installation is critical to operate pump properly.
Foot Installation
Foot Installation

Are you mixing or pumping?

Mixing

Mixing

Pumping

Pumping

Screw Attachment A onto your Aeromixer pump. Choose the appropriate fitting for your hose size and screw it onto Attachment A. If necessary, use a hacksaw or similar to modify Attachment B as pictured. Secure using hose clamp.
Pumping

Let’s get it in the tank!

Placement

Placement

  1. Place both tips of stabilizing foot against sidewall of tank
  2. Aeromixer should sit flat on the bottom of the tank.
    Placement

Read this, it’s important!

10 Things you should know…

  1. Ensure stabilizing foot screws are tightened all the way before use.
  2. Aeromixer requires a dedicated non-GFCI outlet.
  3. For ease of set up, place your Aeromixer in an empty tank. Ensure that your Aeromixer is placed against the sidewall of your tank, with both tips of the green stabilizing foot making contact with the sidewall.
  4. Nutrients should be added slowly when your Aeromixer is running in a full tank of water. No more than a 1/4 pound of dry nutrients per gallon of water can be added to your mixing tank. (Oversaturation of Nutrients can cause hydrolock and will void warranty of your Aeromixer.)
  5. Never lift your Aeromixer by its air intake hose or by the power cord.
  6. Don’t start your Aeromixer unless it is submerged in at least 5 1/2” of water.
  7. The end of the air intake hose must be out of the tank to inject air. Make sure the air intake hose is not kinked and is clear of debris.
  8. Aeromixer is not designed for continuous use while mixing. Recomended run times are as follows: (Please note every tank and environment is different and may require time adjustments. Please contact us if you have any temperature issues.)
    Tank size (Gallons)Time to run AeromixerTime to let tank rest
    50-10050-100 gallons gallons| 15 minutes on| 2 hours off
    ---|---|---
    100-250 gallons| 30 minutes on| 2 hours off
    250-500 gallons| 1 hour on| 2 hours off
    500-1000 gallons| 2 hour on| 2 hours off
    1000-3000 gallons| 3 hour on| 2 hours off
  9. Cleaning your Aeromixer regularly is important. See page 9 for detailed instructions.
  10. Never service or move your Aeromixer while it is plugged in.

Cleaning

Run your Aeromixer in fresh water after every use for 10-30 seconds to clean residue from your pump. Every so often it’s good to deep clean your Aeromixer, to do so, follow instructions below.
Cleaning

Operation

OPERATION

WARNING Risk of burns or death from electric shock. Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water. Disconnect power from pump before handling, servicing, or attempting to repair pump.

  1. The pump must be standing in at least 5 1/2” (135mm) of water before starting. The shaft seal is water lubricated and may be damaged if pump runs dry.
  2. After starting, the pump will lower the water level to 3/16” (4.75mm) before losing suction. It will not pick up water less than 3/16” deep when running and will not operate successfully if started in only 3/16” of water.
  3. Do not leave pump unattended! If the pump has been operating satisfactorily and the discharge stream suddenly stops coming out of the hose, stop the pump immediately; do not allow it to run dry. A mop or squeegee will be needed to remove remaining water.
  4. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the overload protector will stop the motor before it is damaged. When the motor has cooled sufficiently, the overload protector will reset itself and the motor will restart.

NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check it to find the problem. Low voltage, long extension cords, clogged impeller, too much back pressure in the discharge hose (as when pumping through 50’ (15m) of coiled hose), or running pump with no load, can all cause excessive cycling and overheating.

Specification

Model AER050-3000
Nominal voltage 115V/60HZ
Output power 3/4 hp
Motor full load 7.1 amps
Protection type IPX8
Max. Height 40ft
Max. Submersion depth 17ft
Max. Conveying amount 4450gph
Max. Fluid temperature 95 F
Diameter of pipe NPT1″ NPT1-112″
  NPT1-1/4’s GHT3/4”

TROUBLEsHOOTING

Disconnect power from pump before handling, servicing, or attempting to repair pump.

SYMPTOM

| POSSIBLE CAUSE(S)|

CORRECTIVE ACTION

---|---|---
Aeromixer isn’t injecting air into the mixing tank.| Blocked air hose| Check to make sure the air intake hose isn’t kinked or plugged, and is NOT submerged.
Aeromixer spins in circles when it is turned on.| Stabilizing foot not installed correctly
Aeromixer not placed correctly in tank
Tank is dirty/slippery| Please refer to page 2 of this manual for proper installation.
Please refer to page 6 of this manual for proper placement.
Clean tank and rinse with fresh water.
Aeromixer won’t start or run.| Popped circuit
Low line voltage
Defective motor
Impeller stuck| Check breaker box. If voltage is under recommended minimum, check size of wiring from main breaker on property.
Contact Aeromixer, claims@aeromixer.com
If impeller won’t turn, follow cleaning
Aeromixer operates but delivers little or no water.| Stabilizing foot not installed correctly
Low line voltage
Something caught in impeller
Small diameter hose or long discharge line
Air lock
Kinks/bends in hose| Please refer to page 2 of this manual for proper installation. Ensure that stabilizing foot screws are fully tightened.
Use only 14 gauge or larger extension cords. Use short extension cords when necessary.
Clean out impeller.
Use larger diameter garden hose or 1” flexible pipe. Eliminate any excess hose. Short hoses work best.
Turn off Aeromixer for a few seconds, clean out anti-airlock hole and restart pump.
Straighten hose.

Don’t see the issue you are having? Check our FAQ page at aeromixer.com or contact us directly atinfo@aeromixer.com.
We are here to help!

Warranty

RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.

LIMITED WARRANTY

Aeromixer warrants to the original consumer purchaser (“Purchaser” or “You”) of its products that they are free from defects in materials and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at Aeromixer’s option, subject to the terms and conditions set forth below. The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of original product- not the date of replacement under warranty. The warranty is limited to repair or replacement of product only- Purchaser pays all removal, installation, labor, shipping, and incidental charges. For parts or troubleshooting assistance, DO NOT return product to your retail store.

Claims made under this warranty shall be made by returning the product to Aeromixer INC immediately after the discovery of any alleged defect. Aeromixer will subsequently take corrective action as promptly as reasonably possible. No requests of service will be accepted if received more than 30 days after the warranty expires.

General Terms and Conditions

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following: (1) Acts of God; (2) products which, in Aeromixer’s sole judgment, have been subject to negligence, abuse, accident, misapplication, tampering, or altercation; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use, or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.

This warranty sets forth Aeromixer’s sole obligation and purchaser’s exclusive remedy for defective products.

Aeromixer SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYONG THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

Contact Us

Aeromixer INC

Aeromixer.com
Tel: +1 541 690 0888
For additional assistance or questions,
email: info@aeromixer.com
A Southern Oregon Company
Made in China
202

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals