IMPORTANT SAFETY PRECAUTIONS

Original instructions covering Advantage IR2 1300W & IR3 1950W produced 042016 onwards.

INSTALLATION & OPERATING INSTRUCTIONS

READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE.

Failure to observe these instructions will invalidate the warranty.

This unit may be a source of possible shock and must only be installed and serviced by a qualified electrician.

Do not disassemble. No user-serviceable parts inside. Source of possible ignition.

The heating elements reach very high temperatures without visible signs of the unit being on. Because Advantage IR2 & IR3 are not fitted with a protective grill, the heaters are not for domestic or household use. Also, the heaters must not be used or installed in any commercial premises where they can be accidentally touched or where there is a risk of damage to the ceramic elements.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

  1. This appliance must be disconnected from its power source during installation or service activities and when replacing.

  2. This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.

  3. In order to avoid overheating and potential fire hazard, DO NOT cover the heater. DO NOT cover the heater with insulating material or a similar material under any circumstances.

  4. DO NOT touch the heater when in use. The Herschel Advantage IR rises to very high temperatures in use. After the heater has been switched off the elements remain hot for a considerable time and the unit should not be touched within 30 minutes minimum. Please attach the supplied notice
    CAUTION DO NOT TOUCH HEATER to the wall near the heater or in a location where it can easily be seen.

  5. DO NOT use the heater if the Ceramic panels or power cord are damaged. These must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  6. DO NOT use the heater to ignite materials.

  7. This heater must only be used for the heating of people or buildings in a commercial environment.
    The Advantage is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, regardless of whether they have been given instruction or are under supervision. Children should be kept away and should not be left unsupervised around the unit.

  8. All operators shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not plug in, switch on or regulate the appliance or perform user maintenance including cleaning.

  9. IMPORTANT: Ensure supply voltage does not exceed 245 volts.

SAVE THESE INSTRUCTIONS.

ELECTRICAL INFORMATION

Wiring to this unit must be connected in accordance with the relevant national electrical safety standards and must be earthed. The electrical supply to the unit should be provided by connecting to a circuit protected by a fuse or miniature circuit breaker suitable for the electrical rating of the unit in accordance with Tables 1 or 2.

The supply to the heater must be switched separately using a switch appropriately rated for the load and supply voltage. A switched fused spur may also be used on existing ring main circuits where the load current is less than 13A. In both cases, the switch must be double pole (disconnecting both live and neutral conductors) and form part of the fixed wiring in the installation in accordance with applicable wiring regulations. The spur fuse should also be rated in accordance with the appropriate table. In either case the switch used to operate the Herschel Advantage IR must be indoors and readily accessible.

Advantage IR2
Advantage IR2

Table 1

Date HERSCHEL ADVANTAGE IR 2 Specification
Supply Rated Power Fuse
230V 1300 W 10A

Ensure supply voltage does not exceed 245V

Advantage IR3
Advantage IR3

Table 2

Table 2 HERSCHEL ADVANTAGE IR 2 Specification
Supply Rated Power Current
230V 1950 W 8.5 A

Ensure supply voltage does not exceed  245V

The cable used to connect to the existing wiring should be correctly rated solid core wiring cable. Please note that the use of flexible appliance cable with stranded conductors for permanent wiring (except for the final connection between a cable outlet and the fixed equipment) is prohibited by IEE wiring regulations.

Where applicable, these regulations preclude the use of a 13A plug and socket for powering the Herschel Advantage IR. For the final connection to the Herschel Advantage IR, only the flexible cable and cable entry supplied with the unit must be used. The cable must connect to the supply in a suitable enclosure or cable outlet designed for that purpose. The cable outlet current carrying capacity must be greater than the recommended fuse current rating given in Table 1 or Table 2.

If the flexible cable is taken through a wall for connection purposes, suitable conduit or mechanical protection must be used through the wall to protect the cable from mechanical damage within the wall. The mounting position of the unit must ensure that any mechanical damage to the flexible cable is unlikely. Any exposed flexible cable is to hang down (not tied UP) and must have adequate clearance from the heater to prevent scorching or damaging the cable.

Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to NEUTRAL (‘N’) and the GREEN/YELLOW wire to EARTH (‘E’).

MOUNTING POSITION

The Herschel Advantage IR must be located in a position to allow proper and efficient use but one that ensures hot parts are not touched accidentally. The recommended installation height of the Advantage is 2.3m to 2.5m (90”-98”) from the floor and under no circumstances is it to be installed at less than 2.3m from the floor. In all cases it should be installed at a height where it cannot be touched in operation. Consideration should be given to any temporary or occasional additions such as stages or platforms, and the height should be adjusted accordingly. The Herschel ADVANTAGE IR should be firmly and permanently attached to the wall using the bracket supplied, with the heaters angled down at 60° from vertical (see diagram 1). The bracket allows the heater to be mounted between 50° and 70° from vertical and should not be mounted outside these parameters. The Herschel Advantage IR is designed to be mounted horizontally on a wall. DO NOT MOUNT POINTING VERTICALLY DOWNWARDS. The heater is not designed for ceiling mounting.

In areas with air movement/wind the directional Far Infrared spread may reduce by 1/3 to 1/2. In these areas we recommend mounting at the lowest recommended height (see diagram 1) and proportionally increasing the number of heaters.

CAUTION:

  • Ensure mains power is OFF before commencing installation.
  • Heater must not be located immediately below a socket outlet.
  • Joists, beams and rafters shall not be cut or notched to install the appliance.
  • Do not install the Advantage IR into a ceiling recess, nor adjacent to a heater that has been ceiling recessed.
  • The identification mark and model reference should be visible after installation.
  • The Herschel Advantage IR must not be attached so as to face or be close to any combustible material (eg, wood or PVC cladding, fascia or soffit).
  • The fixed wiring insulation coming into contact with parts with a temperature rise of greater than 50°C must be protected, for example, by sleeking having an appropriate temperature rating.

Diagram 1.
Diagram

EXTERIOR USE

The unit is protected against water ingress (protection level IPX4), however it is recommended that the unit is installed in a covered outdoor area to give maximum protection and longevity against the effects of driving rain, wind, frost, salt water contamination, etc. The canopy/roof/cover must be of a permanent nature, there must be a minimum clearance of 0.3m (12”) between the cover and any part of the Advantage IR and the cover must extend a minimum of 2m (79”) from the wall.

INITIAL USE

There may be an odor or vapor from the heater on initial use or if heater has not been used for an extended period. This is normal and is a result of a build up of dust.

USER MAINTENANCE

The Herschel Advantage IR is maintenance free but to maintain appearance it should occasionally be cleaned all over with a soft dry cloth. No abrasive cloths or cleaners should be used and appliances such as pressure washers, steam cleaners, etc., should never be used. Cleaning should only be done when the unit is cold and switched off. All personnel cleaning and maintaining the unit must have suitable training and information to carry out the operation safely.

WARRANTY

Register your product here:
https://www.herschel-infrared.com/customer-service/warranty-registration/

The Herschel Advantage IR is guaranteed against failure due to faulty materials or workmanship for five years from date of purchase, excluding the Ceramic Elements (12 months warranty). In the unlikely event of failure of the unit within this time, the unit must be returned to the supplier for repair or replacement. The guarantee is invalid if the correct installation instructions as given in this leaflet have not been adhered to. Refer to Herschel Infrared Ltd’s warranty policy for full details. See https://www.herschel- infrared.com.

Note your serial number for future reference:

ELECTRICAL EQUIPMENT

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.

IMPORTANT NOTICE TO PURCHASER

Before utilizing the product, you should determine the suitability of the product for its intended use. HERSCHEL INFRARED LTD expressly disclaims the implied warranties and conditions of merchantability and fitness for a particular purpose. In no case shall HERSCHEL INFRARED LTD be liable under any legal theory, including but not limited to contract or strict liability, for any direct, indirect special, incidental or consequential damages resulting from product use.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HERSCHEL User Manuals

Related Manuals