FLOMEC QSE Mag Flow Meter Owner’s Manual
- June 3, 2024
- Flomec
Table of Contents
FLOMEC QSE Mag Flow Meter
FOR USE WITH ALL QSE MAG METERS WITH QB ELECTRONICS and QSE Q9 COMPUTER
- Please save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described.
- Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
- Please refer to the back cover for information regarding this product’s warranty and other important information.
DO NOT RETURN THIS PRODUCT TO THE STORE!
Please contact Great Plains Industries, Inc.® before returning any product. If you are missing parts or experience problems with your installation, contact our Customer Support Department. We will be happy to assist you.
Call:888-996-3837 or
316-686-7361
Email: meters@gplains.com
SAVE FOR YOUR RECORDS
Model #:
Serial #:
Purch. Date: __
BEFORE YOU BEGIN
Usage Requirements
- This 4-20mA module is not FM Therefore, the use of this module with an approved metering system voids FM Approval.
- This 4-20mA module requires an input power of 8-32 volts DC (24 VDC is recommended).
- This 4-20mA module is designed for use with all QSE meters that are equipped with QB electronics and QSE Q9 computer.
UNPACKING/INSPECTION
- After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts. Shipping damage claims must be filed with the carrier.
- See General Safety Instructions and all Cautions, Warnings, and Dangers as shown.
SPECIFICATIONS
| 4-20mA MODULE
---|---
Mechanical|
Housing material:| Nylon 6/6
Strain relief:| Hubble PG7. Grip range (Cable outside diameter)
0.11-0.26 in. (2.8-6.6 mm)
Housing port thread:| Female 1/2-20 UNF-2B (Compatible with PG7)
Cable
| Belden 9363 (22 AWG-3 conductors with drain wire and shield)
Note: The white wire conductor and drain wire are not
used in this application and have been snipped off.
Cable length| 10 ft. (3m), provided
Operation temperature:| Please See “QSE Series Electromagnetic
Meter”
Owner’s Manual
Storage temperature:| -40° to +180°F (-40° to +82°C)
Power:|
Type:| Loop powered 1
Voltage minimum:| 8 VDC
Voltage maximum:| 32 VDC
Isolated:| No
Primary Output (4-20mA):|
Type:| Loop
Minimum:| 4 mA
Maximum:| 25 mA
The QSE meter and QSE Q9 computer cannot be powered using 4-20mA loop
power.
They require a customer-supplied power supply and power cable (QSE meter
powered via QB Electronics). Please see the “QB Electronics for QSE
Electromagnetic Meter” owner’s manual for power supply wiring/configuration
instructions.
NOTE:
Scaled Pulse Output is provided via QB Board. Please see the “QB
Electronics for QSE Electromagnetic Meter” owner’s manual for
wiring/configuration instructions.
SPECIFICATIONS (Continued)
Dimensions
| Length (A)| Height (B)| Width (C)| Strain
Relief (D)
---|---|---|---|---
4-20mA Module
| 3.45 in. (88 mm)| 0.90 in. (23 mm)| 2.18 in. (55 mm)| 0.86 in. (22 mm)
4-20mA Module shown installed on 1-inch QSE Meter.
NOTE:
The module must always be installed with a QSE Q9 computer. Not all QSE
models are compatible with the QSE Q9 computer / 4-20mA module combination.
Refer to the model number matrix to determine compatibility.
APPROVAL RATINGS
QSE Q9 Computer Electronics
WEEE DIRECTIVE
The Waste Electrical and Electronic Equipment (WEEE) directive (2002/96/EC) was approved by the European Parliament and the Council of the European Union in 2003. This symbol indicates that this product contains electrical and electronic equipment that may include batteries, printed circuit boards, liquid crystal displays, or other components that may be subject to local disposal regulations at your location. Please understand those regulations and dispose of this product in a responsible manner.
RoHS Compliant (2011/65/EU)
This product is in compliance with the RoHS Directive of the European Parliament and of the Council on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.
INSTALLATION
This manual specifically addresses the preparation and wiring of the QSE 4-20mA module only. Other meters and computer information and specifications are contained in their respective manuals that were received with the QSE meter.
The 4-20mA module was installed on your QSE meter and pre-wired at the
factory.
The module has had the zero set to the meter’s minimum specified flow rate
and the span has been set to the meter’s maximum specified flow rate. Refer to
the QSE Q9 owner’s manual for instructions on how to change the zero and span
settings of your meter using the buttons on the QSE Q9 computer.
NOTE:
The QSE meter and QSE Q9 computer cannot be powered using a power. They
require a customer-supplied power supply and power cable (QSE meter powered
via QB Electronics).
Please see the
WIRING
NOTE:
The ground of all QB electronics must be galvanically isolated from the 4-20mA
loop ground (return). Please see “QB Electronics for QSE Electromagnetic
Meter” Owner’s Manual for more information. “QB Electronics for QSE
Electromagnetic Meter” owner’s manual for power supply wiring/configuration
instructions. 4-20mA loop
CABLE REPLACEMENT (4-20mA)
The 4-20mA module comes pre-wired at the factory with a 10 ft. 3-conductor
cable with the white wire conductor and drains wire snipped off. Should this
cable need to be replaced (longer cable, cable damage, etc.); the following
instructions will assist you.
NOTE:
If another 3-conductor cable is used, snip off the white wire conductor and
drain the wire.to prevent electrical contact within the case.
If using a 2-conductor cable, it is recommended to use Belden 9501 (or
equivalent): A shielded, 2-conductor of 24 AWG tinned copper, with a 24 AWG
tinned copper drain wire, and PVC cable jacket with a diameter of .156
(6.0mm).
-
Loosen the (4) screws attaching the QSE Q9 computer and 4-20mA module to the cover plate. Using the screws to maintain alignment, lift the QSE Q9 computer and 4-20mA modules from the meter as a unit, being careful of the 10-pin ribbon cable connecting the 4- 20mA module to the cover plate PC board. (See Figure 6).
NOTE:
If needed for ease of wiring, the right-angle 10-pin ribbon cable connector can be
NOTE:
If needed for ease of wiring, the right-angle 10-pin ribbon cable connector can be -
Disconnect the (2) wires from the 4-20mA PC board terminal block, loosen the dome nut of the strain relief and remove the old cable. (See Figure 7). Reverse this procedure to install the new cable.
-
Reconnect the right angle 10-pin connector, if detached, and reinstall the QSE Q9 computer and 4-20mA module to the cover plate. Ensure the 4-20mA module seal is seated and tighten the (4) screws.
NOTE:
Keep track of your wire colors and their QSE connections to ensure proper routing to your process instrumentation.
CALIBRATION
Adjusting ZERO and SPAN
To set or adjust ZERO and SPAN settings, refer to the QSE Q9 Owner’s Manual
Configuration Mode (Daughter Board Options) and Calibration Mode Section for
further instructions.
NOTE:
The QSE Q9 Computer controls the 4-20mA settings. It is recommended to verify
and set (if necessary) the most optimal Calibration Method of the QSE Q9
Computer (see QSE Q9 Owner’s Manual referenced above) before adjusting 4-20mA
settings.
Visit flomecmeters.com to download owner’s manuals and other technical
documents.
TROUBLESHOOTING
Symptom | Possible Cause(s) | Corrective Action |
---|---|---|
1. Incorrect or no input power. |
2. Not wired correctly.
3. Broken connection.
4. Defective PC board connector.
5. Defective unit.
| 1. Supply correct power requirements.
| 2. Check the owner’s manual for the correct installation.
A. No 4-20mA output signal.
| 3. Check resistance to determine the location of the break.
| 4. Contact the distributor or factory for a replacement
| 5. Contact the distributor or factory for replacement.
| 1. ZERO and SPAN are not set correctly on the QSE Q9 computer.| 1. Check
the QSE Q9 owner’s manual for instructions on how to set ZERO and SPAN for the
meter.
B. Signal not between 4-20mA when fluid is flowing.
| 2. 4-20 mA Module output signal “ZERO” and “SPAN” does NOT match the
customer’s recording device “ZERO” and “SPAN” settings.| 2. Reconfigure
4-20mA Module output signal “ZERO” and “SPAN” to match the Customer’s
recording device “ZERO” and “SPAN” (or vice versa).
| 3. QSE Q9 computer calibration is NOT optimized for best results.| 3.
Verify QSE Q9 computer value is giving the correct flowrate.
C. QSE Q9 computer value not giving correct Flowrate.
| 1. QSE Q9 computer showing velocity or volume totals instead of flow rate.|
1. Press the “top button” of the QSE Q9 computer until the flow rate is
displayed (see Operation Section in the QSE Q9 owner’s manual).
| 2. QSE Q9 computer calibration is not optimized for best results.| 2. If
“1” above is not the issue, See the Calibration Section of this manual
PARTS LIST
Part Number Description
901002-52| O-ring
PARTS & SERVICE
For warranty consideration, parts, or other service information, please
contact your local distributor. If you need further assistance, contact the
GPI Product Support Department in Wichita, Kansas, during normal business
hours.
A toll-free number is provided for your convenience.
1-888-996-3837
To obtain prompt, efficient service, always be prepared with the following information:
- The model number of your meter.
- The serial number or manufacturing date code of your meter.
- Part descriptions and numbers.
For warranty work, always be prepared with your original sales slip or other evidence of purchase date.
IMPORTANT:
Please contact GPI before returning any parts. It may be possible to diagnose
the trouble and identify needed parts in a telephone call.
Caution
Do not return this product without prior approval from the GPI Product
Support Department. Due to strict government regulations, GPI cannot accept
parts unless they have been drained and cleaned.
FLOMEC® TWO-YEAR LIMITED WARRANTY
Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2-year warranty. Manufacturer’s sole obligation under the foregoing warranties will be limited to either, at the Manufacturer’s option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and Buyer’s exclusive remedy for breach of any such warranties will be enforcement of such obligations of Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom the such product is transferred during the warranty period.
The warranty period shall begin on the date of manufacture or on the date of purchase with an original sales receipt. This warranty shall not apply if:
- the product has been altered or modified outside the warrantor’s duly appointed representative;
- the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer’s operating instructions.
To make a claim against this warranty, or for technical assistance or repair, contact your FLOMEC distributor or contact FLOMEC at one of the locations below.
In North or South America contact
Great Plains Industries, Inc. 5252 East 36th St. North Wichita, KS 67220-3205
USA
888-996-3837
www.flomecmeters.com
(North America)
Outside North or South America contact
GPI Australia (Trimec Industries Pty. Ltd.) 12/7-11 Parraweena Road Caringbah
NSW 2229 Australia
+61 02 9540 4433
www.flomec.com.au
The company will step you through a product troubleshooting process to
determine appropriate corrective actions.
GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR
DIRECT, INDIRECT, INCIDENTAL, AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR
LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER.
The company herewith expressly disclaims any warranty of merchantability or
fitness for any particular purpose other than for which it was designed.
This warranty gives you specific rights and you may also have other rights
which vary from U.S. state to U.S. state.
NOTE:
In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the
resale availability of the warranty terms).
© 2021 Great Plains Industries, Inc., All Rights Reserved. Great Plains Industries, Inc. / 888-996-3837 / flomecmeters.com
References
- Great Plains Industries Fuel Transfer Pumps and Flow Meter Systems — GREAT PLAINS INDUSTRIES
- FLOMEC Flow Meters - Flow Meter & Instrumentation Manufacturer
- Great Plains Industries Fuel Transfer Pumps and Flow Meter Systems — GREAT PLAINS INDUSTRIES
Read User Manual Online (PDF format)