FLOMEC 02 Series Electronic Flow Meter Owner’s Manual

June 3, 2024
Flomec

FLOMEC 02 Series Electronic Flow Meter

IMPORTANT NOTICE

This meter is not approved for use with flammable liquids. Do not use with liquids or chemicals that are not compatible with the wetted materials found in the Specifications section. This meter is not legal for trade applications. This meter is sensitive to electrical “noise” and may not operate correctly if located near certain electrical equipment.

CALIBRATION

This meter has a permanent factory calibration for light viscosity fluids. If installed and used correctly, accuracies of no greater than ±5% will be obtained.

INSTALLATION

This meter may be installed in-line either horizontally or vertically, or at the end of the hose adjacent to the nozzle if present. For best accuracy, provide 10 inches of pipe upstream and 5 inches of pipe downstream. The use of pipe sealant or PTFE tape is acceptable. Review your application for suitability. Attach meter with arrow on outlet port pointed in the direction of flow.
For Aluminum Housings:
Using a wrench, tighten meter at the ends.

For Nylon Housings :
Hand tighten only. Avoid using metal connections, as this could damage the housing.

OPERATION

Batch and Accumulative Totals
This meter maintains two totals: Batch and Accumulative. The Batch total may be reset to measure flow during a single use. The Accumulative total provides continuous measurement and may not be manually reset. The Batch total is labeled TTL1. The Accumulative total is labeled TTL2. When the Accumulative total reaches a maximum reading of 9999, it will automatically reset to zero. Press the DISPLAY button briefly to switch between Batch and Accumulative totals.

Activate the Meter
Turn the meter ON by starting fluid flow or briefly pressing the DISPLAY button. The meter will display the batch or accumulative total from last use.
Press DISPLAY briefly to display the batch total. Hold the DISPLAY button down for three seconds to reset that batch total to zero.
This meter is programmed to turn off automatically if not used for approximately one minute.

Scaled Output Pulse
For every whole unit (Gallon or Litre) that passes through the meter’s Batch Total (TTL1), a single pulse is transmitted via the attached cable. The White wire is signal and the Black wire is common (GND) (See Specifications).

Note : Some interface devices may not have an internal pull-up resistor. Use a minimum 820 ohms resistor if necessary

MAINTENANCE

Proper handling and care will extend the life and service of this meter.

Turbine Rotor
This meter is virtually maintenance-free. However, it is important for the rotor to move freely. Keep the meter clean and clear of contaminants. Remove debris or deposits from the rotor using a soft brush or small probe. Be careful not to damage the turbine rotor or supports.

CAUTION
Blowing compressed air through the turbine assembly could damage the rotor.

BATTERY REPLACEMENT

The meter is powered by two AAA alkaline batteries that may be replaced while the meter is installed. When batteries are removed or lose power, the batch and accumulative totals reset to zero, but the factory calibration is retained. If the meter display becomes dim or blank, replace the batteries as follows:

  1. Remove the four Phillips-head screws from the face of the meter and lift the faceplate from the turbine.
  2. Remove the old batteries and clean any corrosion from the terminals.
  3. Install new batteries. Make sure the positive post is in the correct position.
  4. When the batteries are replaced, the faceplate will power ON. Check the display to ensure normal functions have resumed before assembling again.
  5. Re-seat batteries, if necessary, and position the faceplate on the turbine housing. To avoid moisture damage, make sure the seal is fully seated. Tighten the four screws on the faceplate.

SERVICE

For technical assistance, warranty replacement, or repair contact your FLOMEC® distributor:

In North or South America:
888-996-3837 / GPI.net

Outside North or South America:
+61 2 9540 4433 / flomec.com.au

To obtain prompt, efficient service, always be prepared with the following information:

  • The model number.
  • The manufacturing date code (located under the cover plate).

For warranty work, always be prepared with your original sales slip or other evidence of purchase date. Please contact your FLOMEC® distributor before returning any part. It may be possible to diagnose the trouble and find a solution with a telephone call. You may also be informed of any special requirements you will need to follow for shipping.

SPECIFICATIONS

DISPOSAL
The Waste Electrical and Electronic Equipment (WEEE) directive (2002/96/EC) was approved by the European Parliament and the Council of the European Union in 2003. This symbol indicates that this product contains electrical and electronic equipment that may include batteries, printed circuit boards, liquid crystal displays, or other components that may be subject to local disposal regulations at your location. Please understand those regulations and dispose of this product in a responsible manner.

Declaration of Conformity

  • Manufacturer’s Name :  Great Plains Industries, Inc.
  • Manufacturer’s Address:  5252 East 36th Street North Wichita, KS USA 67220-320

Declares, that the product:

  • Product Name :  Electronic Digital Meter
  • Model Numbers:  02A12LM, 02N12LM. 02A3IGM, 02N3I GM, 02A3ILM, 02N31LM. and 02A52L
  1. Council Directive 2014/30/EU (EMC Directive) relating to Electro-Magnetic Compatibility,

  2. EN 61000-6-3: 2007

  3. CISPR 16-2-1 :2008

  4. IEC 61000-4-3 :2006+A2

  5. IEC 61000-4-5 :2014

  6. TEC 61000-4-8 :2009

  7. EN 61000-6-1 :2007

  8. IEC 61000-4-2 :2008

  9. IEC 61000-4-4 :2012

  10. IEC 61000-4-6 :2013

  11. Council Directive 201 1/65/EU (RoHS Directive) relating to the restriction of certain hazardous substances in electrical and electronic equipment.
    Supplementary Information:

  12. This product is not recommended for custody transfer or application where levying by consumption takes place.

  13. This product has insufficient internal volume size or pressure ratings to meet a pressure directive.

  14. Year of Manufacturing is displayed directly on the product as Manufacturing Date Code (Mfg. Date) indicating week and year.

  15. The products comply with the requirements of China RoHS 2 and are recyclable.

  16. The products meet IEC 60529:1989, Degrees of Protection Provided by Enclosures for IP65.

I the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

FLOMEC® TWO-YEAR LIMITED WARRANTY

Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2-year warranty. Manufacturer’s sole obligation under the foregoing warranties will be limited to either, at Manufacturer’s option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and Buyer’s exclusive remedy for breach of any such warranties will be enforcement of such obligations of Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period. The warranty period shall begin on the date of manufacture or on the date of purchase with an original sales receipt. This warranty shall not apply if:

  1. the product has been altered or modified outside the warrantor’s duly appointed representative;
  2. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer’s operating instructions.

To make a claim against this warranty, or for technical assistance or repair, contact your FLOMEC distributor or contact FLOMEC at one of the locations below.

In North or South America contact Great Plains Industries, Inc. 5252 East 36th St. North Wichita, KS 67220-3205 USA 888-996-3837  www.flomecmeters.com (North America) The company will step you through a product troubleshooting process to determine appropriate corrective actions. GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER. The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed. This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state.

NOTE : In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the resale availability of the warranty terms).

© 2021 Great Plains Industries, Inc., All Rights Reserved. Great Plains Industries, Inc. / 888-996-3837 / flomecmeters.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals