SENCOR SBT 50 DIGITAL THERMOMETER User Manual

June 5, 2024
SENCOR

sencor-logo

SENCOR SBT 50 DIGITAL THERMOMETER

SENCOR-SBT-50-DIGITAL-THERMOMETER-product

Before using the product for the first time, please familiarize yourself with the instructions for its use, even if you are already familiar with using products of a similar type. Use the product only as it is described in this manual. Keep the instructions for future reference. At least for the duration of the warranty, we recommend keeping the original packaging, receipt, and warranty conditions.

Notice: Failure to follow the instructions given in the user manual may lead to a malfunction of the device or its function damage.

SAFETY INSTRUCTIONS

  • Do not expose the thermometer to direct sunlight, high temperatures, excessive humidity, or dustiness. Otherwise, the functionality of the device may be affected.
  • Do not rinse the thermometer under running water or immerse it in water or any other liquid.
  • The thermometer is not resistant to shocks or impacts. Protect it from falls.
  • Do not try to bend the thermometer.
  • Do not disassemble the thermometer (except for removing the cover to replace the battery) and do not carry out any work on it no modifications.
  • Measurement of children’s temperature should always be done under adult supervision.
  • Keep the device, including batteries, out of the reach of children.

USE THE THERMOMETER

  1. Before first use, remove the protective film that covers the display and the on/off button.

  2. To turn on the thermometer, press the button. All elements are briefly displayed on the display and a sound has heard as a beep. Then the display shows M” (Memory), which indicates that the memory has been recalled, and the last measured value. After the last measured value is displayed, the display shows 37 °C and an automatic test of the device status will take place. The display will then show Lo (if the ambient temperature is lower than 32 °C) and the °C unit symbol flashes. The thermometer is now ready for measurement.

  3. Take your body temperature. During the measurement, the display shows the current temperature and the symbol of the unit of measurement °C flashes. The end of the measurement will be announced by a sound signal (10 beeps). Unit symbol the °C measurement stops flashing and the display shows the highest measured value. Remove the thermometer from its place moving. The measured value will be displayed on the display until the thermometer is turned on.
    Note: The measurement time takes approximately 30 to 60 seconds.

  4. The thermometer automatically switches off after about 10 minutes from the last measurement. To extend battery life, we recommend turning off the thermometer with the button after use.

  5. The last measured value is automatically stored in the device’s memory. This value on the display will be displayed briefly when the thermometer is switched on again and will automatically be deleted with the next measurement.

MEASUREMENT METHODS

In the oral cavity (oral)
Place the tip of the thermometer to the right or left of the frenulum of the tongue. Close your mouth and breathe regularly nose During the measurement, the tip of the thermometer must remain in the same place and must be in constant contact with the mucous membrane. Do not eat or drink before the measurement. In the anus (rectal) From a medical point of view, this is a more imprecise method of measuring body temperature. The tip of the thermometer was carefully inserted into the anus but to a maximum depth of 1.5 cm.

Underarm (axillary)
Place the tip of the thermometer in the deepest part of the armpit. Press the shoulder firmly against the body. Before the measurement itself, it is necessary to avoid overheating with warm clothes or cooling the armpit. body temperature measurement results vary depending on the chosen measurement method. The temperature measured in the anus can be about 0.5 °C higher compared to the temperature measured in the oral cavity and in comparison with the temperature measured in the armpit 0.5-1.5 °C higher.

CLEANING

  • Before first use, clean the tip of the thermometer with a soft cloth moistened with a disinfectant (e.g. in 70% ethanol). Clean the tip of the thermometer in the same way after each use. Thermometers do not sterilize by boiling!
  • To clean the remaining parts of the thermometer, use a slightly moistened, soft cloth.
  • Do not use thinners or chemical solvents for cleaning.

STORAGE

If you are not going to use the thermometer for a long time, remove the battery from it.

COMPLIANCE WITH STANDARDS

This device complies with European standards

Medical electrical equipment

  • Part 1: General requirements for basic safety and necessary functionality
  • Part 2: General requirements for basic safety and necessary functionality

Group standard: Electromagnetic compatibility

  • Requirements and tests

Medical thermometers-Part 3:

  • Characteristics of compact electronic thermometers (with extrapolation even without extrapolation) with maximum equipment.
  1. The date of manufacture is marked on the nameplate of the device.
  2. The number of the production lot (batch) is indicated on the type plate of the device.
  3. Manufacturer: Bremen Limited, Unit 1104, 11/F., Two Harbourfront, 22 Tak Fung Street, Hung Hom, Kowloon, Hong Kong, China
  4. Authorized representative: COM s.n.c., Bremen Italy Division, Via Valle Inferiore 31, Todi (PG)- Italians

TECHNICAL SPECIFICATIONS

  • Measuring range temperature below 32 °C temperature above 43 °C: 32-43 C Lo will appear on the display shows.
  • Measurement accuracy: E0.1°C in the range of 35.5-42°C 0.2 °C outside the range of 35.5-42 °C.
  • Degree of protection against electric shock: Attachment part type BF
  • Protection against electric shock: Device with internal power supply
  • Protection against harmful ingress of water: IPXO
  • Mode of operation: Continuous operation
  • Display: LCD
  • Powered up: Micro alkaline battery type LR41 (1.55 V)
  • Energy consumption: 0.15 mW in measurement mode
  • Battery life: min. 200 hours of continuous operation

Explanation of technical terms

IP code: IPXO The device is not protected against the ingress of water (no special protection). Changes to text and technical specifications are reserved.

WARRANTY CONDITIONS

The seller provides the buyer with a warranty for the product for a period of 24 months after the buyer takes over the product. The guarantee is provided under the following conditions. The warranty applies only to new consumer goods sold to consumers for normal domestic use. Rights from liability for defects (complaint) can be exercised by the buyer either with the seller with whom it was Product purchased or the authorized service listed below. however, no later than the end of the period of delay, so that the defect does not worsen, The buyer is obliged to provide the cooperation necessary to verify the existence of the claimed defect in the event of a complaint. Only complete and 2 reasons for compliance with hygiene regulations are accepted for complaint management uncontaminated products. In the event of a valid complaint, the warranty period is extended by the period from the moment of application of the claim until the moment of receipt of the repaired product by the buyer or the moment when it is the buyer is obliged to take over the product after the repair is completed. The buyer is obliged to prove his right to complain (proof of purchase of the product, warranty card, document about putting the product into operation…) In particular, Haruka does not apply to Defects and Dya provides ionization of the use, valid legal regulations, and generally known and customary methods of use, as a result use the product for a purpose other than that for which it is intended to damage to the product as a result of neglect or improper maintenance damage to the product caused by its pollution, accident and force majeure (natural event, fire, evd installation, use of the product contrary to the instructions intrude Voay product functionality defects caused by inappropriate signal quality, interfering electromagnetic field mechanical damage to the product (e.g. one Chaplin. Consumables (batteries) or liku fall.. damage caused by the use of unsuitable media, cartridges, consumables (batteries) or unsuitable operating conditions (e.g. high ambient temperatures, high ambient humidity, shocks… Unauthorized or unauthorized damage, modification, or other changes to the product By OSOD (Service) cases when the buyer does not prove the legitimacy of his rights during the complaint (when and where the complained product buy cases that can be identified with the product listed in the documents by which the buyer proves his right to claim (e.g. damage to the serial number or warranty seal of the device.

USER SUPPORT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals