STELPRO SHU Series Commercial Industrial Unit Heater User Guide
- June 5, 2024
- StelPro
Table of Contents
STELPRO SHU Series Commercial Industrial Unit Heater
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be
considered null and void and the manufacturer deems no further responsibility
for this product.
This product must be installed by a qualified person and connected by a
certified electrician, according to the electrical and building codes
effective in your region. The following instructions must be adhered to in
order to avoid personal injuries or property damages, serious injuries and
potentially fatal electric shocks. Make sure that all screws and electrical
terminal connections are tightly secured before operating the unit in case
they would have loosened during transportation. Protect the heating unit with
the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the
unit’s nameplate. This unit must be grounded. Switch off the power at the
circuit breaker/fuse before installing, repairing and cleaning the unit. Make
sure the unit is appropriate for the intended use (if needed, refer to the
product catalog or a representative).
RECOMMENDED HEATING CAPACITY:
1.25 W/cubic foot (0.03 m³).
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist (industrial
and commercial buildings) who will be able to calculate these heat losses and
optimize the required capacity or consult the “Online heating calculation”
section of the Stelpro Design Web site (residential buildings). To heat a
large room and to increase your comfort, it is recommended to install several
units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.
If the unit capacity is insufficient for the size of the room, it will be in
operation continuously, and may become defective earlier and turn yellow.
Do not install the unit where objects or pieces of furniture could be heat
damaged.
Respect distances and positions indicated in the installation section.
If the installer or the user modifies the unit, he will be held responsible
for any damage resulting from this modification, and the CSA certification
could be void.
This unit must not come into contact with a water source and must be protected
from splashes. Do not use it if any part has been immersed. Moreover, do not
turn it on or off when standing in water or if your hands are wet.
When mounting the unit, make sure that the anchorage used can support the
total weight of the unit with the mounting brackets.
When cutting or drilling into a wall or a ceiling, do not damage electrical
wiring and other hidden utilities.
Do not install this product on walls made of synthetic material such as, but
not limited to, carpet and wallpaper.
When starting up the unit for the first time or after a long period, it is
normal that it produces some temporary odours and whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal
operation. Therefore, be careful and responsible when using it. To
avoid burns, do not let bare skin touch hot surfaces. The unit must cool down
for few minutes since it will stay warm for some time after shut down.
This unit must be installed at least 6 or 12 in. (15 or 30 cm) from any
adjacent surfaces (walls) (according to the unit capacity; see the
installation section). However, make sure flammable materials do not come into
contact with the unit and keep them at least 24 inches (61 cm) from the
unit since they are more flammable than walls. Failure to comply with this
warning could lead to a fire. Some materials are more heat-sensitive than
others, so make sure those near the unit can withstand heat.
Never block unit air vents. This obstruction could lead to overheating, which
could result in a fire.
Do not insert or allow foreign objects to enter any air vent as this may cause
electric shocks, fires, or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to
be used or stored in wet areas or areas containing flammable liquids,
combustible materials or corrosive, abrasive, chemical, explosive and
flammable substances such as, but not limited to, gasoline, paint, chlorine,
sawdust and cleaning products. Some areas are dustier than others. Thus, it is
the user’s responsibility to evaluate if the unit must be cleaned based on
the amount of dirt accumulated on and inside air vents. Accumulated dirt can
lead to a component malfunction or discoloration (yellow). It may cause a fire
hazard if not installed and maintained in accordance with these instructions.
The thermal protection activation indicates that the unit has been subjected
to abnormal operating conditions. If the thermal protection remains activated
or activates and deactivates repeatedly, it is recommended that a qualified
electrician or a certified repair centre examine the unit in order to make
sure it is not damaged. (Refer to the limited warranty).
If the unit is damaged or defective, cut off power supply at circuit
breaker/fuse and call a certified repair centre. (Refer to the limited
warranty).
Note: When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.
SPECIFICATIONS
COMMERCIAL INDUSTRIAL UNIT HEATER – SHU
WATTS| 2 TO 10 kW| 15 TO 30 kW| 40 TO 60 kW
WEIGHT| 32 LB / 15 KG| 60 LB / 27 KG| 95 LB / 44 KG
LENGTH| 15’’ / 394 MM| 17 5/8” / 448 MM| 17 3/4’’ / 451 MM
WIDTH| 18 3/4″ / 476 MM| 22 7/8’’ / 581 MM| 27 1/2’’ / 698 MM
HEIGHT| 12″ / 305 MM| 16’’ / 405 MM| 22 1/4’’ / 565 MM
TECHNICAL DRAWINGS
INSTALLATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to the
installation.
For best results, the following distances shall be respected when
installing these unit heaters
| MAXIMUM HEIGHT FROM THE FLOOR| MINIMUM DISTANCE FROM THE FLOOR|
MINIMUM DISTANCE FROM THE WALL
---|---|---|---
2-10 KW MODELS| 8 FT (2.4 M)| 2 FT (0.6 M)| 6 IN. (15 CM)
15-30 KW MODELS| 10 FT (3.0 M)| 2 FT (0.6 M)| 6 IN. (15 CM)
40-60 KW MODELS| 15 FT (4.6 M)| 6 FT (1.8 M)| 12 IN. (30 CM)
- Avoid directing the airflow from the unit heater towards occupants of the room, beams, poles, machinery and/or against the walls. Instead, try to direct it along the walls, preferably an exterior wall exposed to the wind.
- When using a wall-mounted thermostat, install it on an interior wall or beam, away from cold airflow, other internal heat sources or the hot air discharge coming directly from the unit heater itself. Make sure to insulate the thermostat when installed on a steel beam.
- Smaller rooms will generally require one unit heater only. For larger rooms, install several unit heaters in such a way that will promote a peripheral air circulation, as demonstrated on illustrations 1 and 2.
MAINTENANCE
N.B. In order for the warranty to be valid, the unit must be cleaned
regularly
f the heater operates under normal conditions, it is not necessary to
lubricate the motor since it has been permanently lubricated.
Cut off power supply at circuit breaker/fuse before cleaning the unit. Use a
soft rag for dusting. When cleaning, use only a damp rag and non-abrasive dish
soap. Do not use abrasive or chemical cleaners because they may damage the
finishing. If the unit is used in a very dusty location, use a vacuum brush to
remove dust and other foreign objects from the grilles. Note that cigarette
smoke could yellow the discharge grille and that the best way to prevent it is
to clean the unit on a regular basis.
Do not use cleaning products identified with these symbols:
N.B. Note that there is electrical current linked to the unit even if the thermostat is set off. This means that there is a risk of electric shock as long as the unit is energized.
OPERATION
Built-in thermostat: temperature setting ranges from 10°C to 32°C (50°F to 90°F).
REPLACEMENT COMPONENT LIST
REF. # | PART # | DESCRIPTION |
---|---|---|
1 | BLA-008 | BLADE 10” 20° 5B (2-5 KW) |
1 | BLA-010 | BLADE 10” 32° 4B (7,5-10 KW) |
1 | BLA-011 | BLADE 14” 32° 4B (15-25 KW) |
1 | BLA-012 | BLADE 14” 40° 4B (30 KW) |
1 | BLA-013 | BLADE 18” 32° 4B (40-60 KW) |
2 | BOUT-008 | THERMOSTAT KNOB (BLACK) |
3 | CONT-3002 | CONTACTOR 30 A 2 POLES 24 V |
3 | CONT-3022 | CONTACTOR 30 A 2 POLES 240-208 V |
3 | CONT-3503 | CONTACTOR 35 A 3 POLES 24 V |
3 | CONT-3512 | CONTACTOR 35 A 2 POLES 120 V |
3 | CONT-4013 | CONTACTOR 40 A 3 POLES 120 V |
3 | CONT-4023 | CONTACTOR 40 A 3 POLES 240-208 V |
4 | ELF-SHU1021 | ELEMENT (KIT) 10 KW 240 V 1 PH |
4 | ELF-SHU1023 | ELEMENT (KIT) 10 KW 240 V 3 PH |
4 | ELF-SHU1031 | ELEMENT (KIT) 10 KW 347 V 1 PH |
4 | ELF-SHU1051 | ELEMENT (KIT) 10 KW 480W 1 PH |
4 | ELF-SHU1053 | ELEMENT (KIT) 10 KW 480 V 3 PH |
4 | ELF-SHU1061 | ELEMENT (KIT) 10 KW 600 V 1 PH |
4 | ELF-SHU1063 | ELEMENT (KIT) 10 KW 600 V 3 PH |
4 | ELF-SHU1081 | ELEMENT (KIT) 10 KW 208 V 1 PH |
4 | ELF-SHU1083 | ELEMENT (KIT) 10 KW 208 V 3 PH |
4 | ELF-SHU1521 | ELEMENT (KIT) 15 KW 240 V 1 PH |
4 | ELF-SHU1523 | ELEMENT (KIT) 15 KW 240 V 3 PH |
4 | ELF-SHU1531 | ELEMENT (KIT) 15 KW 347 V 1 PH |
4 | ELF-SHU1551 | ELEMENT (KIT) 15 KW 480 V 1 PH |
4 | ELF-SHU1553 | ELEMENT (KIT) 15 KW 480 V 3 PH |
4 | ELF-SHU1561 | ELEMENT (KIT) 15 KW 600 V 1 PH |
4 | ELF-SHU1563 | ELEMENT (KIT) 15 KW 600 V 3 PH |
4 | ELF-SHU1581 | ELEMENT (KIT) 15 KW 208 V 1 PH |
4 | ELF-SHU1583 | ELEMENT (KIT) 15 KW 208 V 3 PH |
4 | ELF-SHU2021 | ELEMENT (KIT) 20 KW 240 V 1 PH |
4 | ELF-SHU2031 | ELEMENT (KIT) 20 KW 347 V 1 PH |
4 | ELF-SHU2051 | ELEMENT (KIT) 20 KW 480 V 1 PH |
4 | ELF-SHU2053 | ELEMENT (KIT) 20 KW 480 V 3 PH |
4 | ELF-SHU2061 | ELEMENT (KIT) 20 KW 600 V 1 PH |
4 | ELF-SHU2063 | ELEMENT (KIT) 20 KW 600 V 3 PH |
4 | ELF-SHU2081 | ELEMENT (KIT) 20 KW 208 V 1 PH |
4 | ELF-SHU2083 | ELEMENT (KIT) 20 KW 208 V 3 PH |
4 | ELF-SHU221 | ELEMENT (KIT) 2 KW 240 V 1 PH |
4 | ELF-SHU223 | ELEMENT (KIT) 2 KW 240 V 3 PH |
4 | ELF-SHU231 | ELEMENT (KIT) 2 KW 347 V 1 PH |
4 | ELF-SHU251 | ELEMENT (KIT) 2 KW 480 V 1 PH |
4 | ELF-SHU253 | ELEMENT (KIT) 2 KW 480 V 3 PH |
4 | ELF-SHU2531 | ELEMENT (KIT) 25 KW 347 V 1 PH |
4 | ELF-SHU2551 | ELEMENT (KIT) 25 KW 480 V 1 PH |
4 | ELF-SHU2553 | ELEMENT (KIT) 25 KW 480 V 3 PH |
4 | ELF-SHU2561 | ELEMENT (KIT) 25 KW 600 V 1 PH |
4 | ELF-SHU2563 | ELEMENT (KIT) 25 KW 600 V 3 PH |
4 | ELF-SHU2581 | ELEMENT (KIT) 25 KW 208 V 1 PH |
4 | ELF-SHU2583 | ELEMENT (KIT) 25 KW 208 V 3 PH |
4 | ELF-SHU261 | ELEMENT (KIT) 2 KW 600 V 1 PH |
4 | ELF-SHU263 | ELEMENT (KIT) 2 KW 600 V 3 PH |
4 | ELF-SHU281 | ELEMENT (KIT) 2 KW 208 V 1 PH |
4 | ELF-SHU283 | ELEMENT (KIT) 2 KW 208 V 3 PH |
4 | ELF-SHU3053 | ELEMENT (KIT) 30 KW 480 V 3 PH |
4 | ELF-SHU3063 | ELEMENT (KIT) 30 KW 600 V 3 PH |
4 | ELF-SHU3083 | ELEMENT (KIT) 30 KW 208 V 3 PH |
4 | ELF-SHU321 | ELEMENT (KIT) 3 KW 240 V 1 PH |
4 | ELF-SHU323 | ELEMENT (KIT) 3 KW 240 V 3 PH |
4 | ELF-SHU331 | ELEMENT (KIT) 3 KW 347 V 1 PH |
4 | ELF-SHU351 | ELEMENT (KIT) 3 KW 480 V 1 PH |
4 | ELF-SHU353 | ELEMENT (KIT) 3 KW 480 V 3 PH |
4 | ELF-SHU361 | ELEMENT (KIT) 3 KW 600 V 1 PH |
4 | ELF-SHU363 | ELEMENT (KIT) 3 KW 600 V 3 PH |
4 | ELF-SHU371 | ELEMENT (KIT) 3 KW 277 V 1 PH |
4 | ELF-SHU381 | ELEMENT (KIT) 3 KW 208 V 1 PH |
4 | ELF-SHU383 | ELEMENT (KIT) 3 KW 208 V 3 PH |
4 | ELF-SHU421 | ELEMENT (KIT) 4 KW 240 V 1 PH |
4 | ELF-SHU423 | ELEMENT (KIT) 4 KW 240 V 3 PH |
4 | ELF-SHU431 | ELEMENT (KIT) 4 KW 347 V 1 PH |
4 | ELF-SHU451 | ELEMENT (KIT) 4 KW 480 V 1 PH |
4 | ELF-SHU453 | ELEMENT (KIT) 4 KW 480 V 3 PH |
4 | ELF-SHU461 | ELEMENT (KIT) 4 KW 600 V 1 PH |
4 | ELF-SHU463 | ELEMENT (KIT) 4 KW 600 V 3 PH |
4 | ELF-SHU471 | ELEMENT (KIT) 4 KW 277 V 1 PH |
4 | ELF-SHU481 | ELEMENT (KIT) 4 KW 208 V 1 PH |
4 | ELF-SHU483 | ELEMENT (KIT) 4 KW 208 V 3 PH |
4 | ELF-SHU521 | ELEMENT (KIT) 5 KW 240 V 1 PH |
4 | ELF-SHU523 | ELEMENT (KIT) 5 KW 240 V 3 PH |
4 | ELF-SHU531 | ELEMENT (KIT) 5 KW 347 V 1 PH |
4 | ELF-SHU551 | ELEMENT (KIT) 5 KW 480 V 1 PH |
4 | ELF-SHU553 | ELEMENT (KIT) 5 KW 480 V 3 PH |
4 | ELF-SHU561 | ELEMENT (KIT) 5 KW 600 V 1 PH |
4 | ELF-SHU563 | ELEMENT (KIT) 5 KW 600 V 3 PH |
4 | ELF-SHU571 | ELEMENT (KIT) 5 KW 277 V 1 PH |
4 | ELF-SHU581 | ELEMENT (KIT) 5 KW 208 V 1 PH |
4 | ELF-SHU583 | ELEMENT (KIT) 5 KW 208 V 3 PH |
4 | ELF-SHU721 | ELEMENT (KIT) 7,5 KW 240 V 1 PH |
4 | ELF-SHU723 | ELEMENT (KIT) 7,5 KW 240 V 3 PH |
4 | ELF-SHU731 | ELEMENT (KIT) 7,5 KW 347 V 1 PH |
4 | ELF-SHU751 | ELEMENT (KIT) 7,5 KW 480 V 1 PH |
4 | ELF-SHU753 | ELEMENT (KIT) 7,5 KW 480 V 3 PH |
4 | ELF-SHU761 | ELEMENT (KIT) 7,5 KW 600 V 1 PH |
4 | ELF-SHU763 | ELEMENT (KIT) 7,5 KW 600 V 3 PH |
4 | ELF-SHU781 | ELEMENT (KIT) 7,5 KW 208 V 1 PH |
4 | ELF-SHU783 | ELEMENT (KIT) 7,5 KW 208 V 3 PH |
5 | MO-017 | MOTOR 240 V (2-4 KW) |
5 | MO-019 | MOTOR 240 V (5-10 KW) |
5 | MO-021 | MOTOR 240 V (15-30 KW) |
5 | MO-022 | MOTOR 600 V/3 PH (40-60 KW) |
5 | MO-023 | MOTOR 460 V (15-25 KW) |
5 | MO-024 | MOTOR 600 V/3 PH (15-30 KW) |
6 | PROT-005 | THERMAL PROTECTION (AUTO.) (L175) 15-30 KW |
6 | PROT-006 | THERMAL PROTECTION (AUTO.) (L150) 40-60 KW |
6 | PROT-013 | THERMAL PROTECTION (AUTO.) (L193) 2-10 KW |
7 | SHUUMB | MOUNTING SUPPORT KIT (2-30 KW) (INCLUDING HARDWARE) |
8 | SHUUMB3 | MOUNTING SUPPORT KIT(40-60 KW) (INCLUDING HARDWARE) |
9 | ST-001 | THERMOSTAT SP (WITH BULB) |
9 | ST-012 | THERMOSTAT DP (WITH BULB) |
10 | TRF200025 | TRANSFORMER 240/24/25 VA |
10 | TRF200040D | TRANSFORMER 240-480/120-240/25 VA |
10 | TRF210025D | TRANSFORMER 347/24/25 VA |
10 | TRF300025 | TRANSFORMER 347/240/100 VA |
10 | TRF320100 | TRANSFORMER 347-380/120-240/500 VA |
10 | TRF320500D | TRANSFORMER 347/240/200 VA |
10 | TRF410200D | TRANSFORMER 240-480/12-24/25 VA |
10 | TRF500025D | TRANSFORMER 240-480/120-240/100 VA |
10 | TRF510100D | TRANSFORMER 480/240/25 VA |
10 | TRF520025 | TRANSFORMER 208-240/24/40VA, CL.2 CL.B |
10 | TRF520200D | TRANSFORMER 240-480/120-240/200 VA |
10 | TRF520500D | TRANSFORMER 240-480/120-240/500 VA |
10 | TRF600025 | TRANSFORMER 600/24/25 VA |
10 | TRF600100 | TRANSFORMER 600/12-24/100 VA |
10 | TRF610025D | TRANSFORMER 480-600/120-240/25 VA |
10 | TRF620025 | TRANSFORMER 600/240/25 VA |
10 | TRF620100 | TRANSFORMER 600/240/100 VA |
10 | TRF620200 | TRANSFORMER 600/240/200 VA |
10 | TRF620500 | TRANSFORMER 600/240/500 VA |
10 | TRF720250 | TRANSFORMER 277/240/250 VA |
10 | TRF810025D | TRANSFORMER 208-416/120-240/25 VA |
10 | TRF810350D | TRANSFORMER 208-416/120-240/350 VA |
11 | HOLD-005 | FUSE HOLDER 2 POLES 600V |
11 | HOLD-009 | FUSE HOLDER 1 POLE 600 V |
11 | HOLD-010 | FUSE HOLDER 2 POLES 600 V |
11 | HOLD-011 | FUSE HOLDER 3 POLES 600 V |
12 | FS-005 | FUSE 15A CLASS CC 600V T.D. |
12 | FS-016 | FUSE 40A CLASS J 600V T.D. |
12 | FS-017 | FUSE 50A CLASS J 600V T.D. |
12 | FS-018 | FUSE 60A CLASS J 600V T.D. |
12 | FS-023 | FUSE 20A CLASS CC 600V T.D. |
12 | FS-024 | FUSE 25A CLASS CC 600V T.D. |
12 | FS-025 | FUSE 30A CLASS CC 600V T.D. |
12 | FS-026 | FUSE 35A CLASS J 600V T.D. |
12 | FS-027 | FUSE 45A CLASS J 600V T.D. |
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|---|
The unit does not work |
- Defective thermostat or wrong thermostat setting
- Open circuit breaker or fuse
- The thermal protection has been activated
- Faulty connections
The unit runs continuously|
- Defective thermostat or wrong thermostat setting
- Heat losses higher than the unit capacity
The enclosure is extremely hot|
- Defective thermal protection
- Blocked air vents
- Defective motor
The unit cycles under control of the thermal protection (overheat indicator)|
- Blocked air vents
- Defective motor
Overheating|
- Defective thermostat or wrong thermostat settin
- Defective motor
The breaker trips when the heater is turned on|
- Faulty connection
- Voltage higher than that written on the nameplate
Elements are on, but the motor does not work|
- Defective motor
The desired room temperature cannot be reached|
- One or more elements are defective
- Defective thermostat or wrong thermostat setting
- Voltage lower than that written on the nameplat
- Heat losses higher than the unit capacity
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and
applies to the following product made by Stelpro: model SHU. Please read
this limited warranty carefully. Subject to the terms of this warranty,
Stelpro warrants its products and their components against defects in
workmanship and/or materials for the following periods from the date of
purchase: 3 years. This warranty applies only to the original purchaser;
it is non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) Stelpro’s customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves
the right to examine or to ask one of its representatives to examine the
product itself or any part of it before honoring the warranty. Stelpro
reserves the right to replace the entire unit, refund its purchase price or
repair a defective part. Please note that repairs made within the warranty
period must be authorized in advance in writing by Stelpro and carried out by
persons authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at:
1-844-STELPRO. The authorization number must be clearly written on the
parcel or it will be refused.
CONDITIONS, EXCLUSIONS AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except of title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts or
omissions relating thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities or services, shutdowns, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from: 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro)
or a use other than that for which the unit was designed; 3) a natural
disaster or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, over voltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages nor does it cover damages caused by negligence
of the user or owner of the product. Moreover, it does not cover the cost of
disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of Stelpro. Any parts replaced
or repaired within the warranty period with the written authorization of
Stelpro will be warranted for the remainder of the original warranty period.
This warranty will be considered null and void and Stelpro will have the right
to refuse any claims if products have been altered without the written
authorization of Stelpro and if the nameplate numbers have been removed or
modified. This warranty does not cover scratches, dents, corrosion or
discoloration caused by excessive heat, chemical cleaning products and
abrasive agents. It does not cover any damage that occurred during the
shipping.
Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages and some of them do not allow limitations
on how long an implied warranty lasts, so these exclusions or limitations may
not apply to you. This warranty gives you specific legal rights and you may
have other rights which vary from state to state or from province to province.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>