- Important Safety Instructions
- UNPACKING YOUR APPLIANCE
- INSTALLING YOUR APPLIANCE
- ELECTRICAL
- CUTOUT & PRODUCT DIMENSIONS
- DOOR ADJUSTMENTS
- DOOR REVERSAL
- INSTALLING THE ANTI-TIP DEVICE
- INTEGRATED PANEL INSTALLATION
- INSTALLING THE DRAIN PLUMBING
- INSTALLING THE WATER SUPPLY
- OPERATION OF ICE MACHINE
- USING YOUR ELECTRONIC CONTROL
- CLEANING YOUR ICE MACHINE
- CARE AND CLEANING
- OBTAINING SERVICE
- HOUSEHOLD PRODUCT WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MLNP115-IS 01A NUGGET ICE MACHINES
MLNP115-SS01B/MSNP115-SS01A
MPNP415-IS81A/MPNP415-SS81A
User Manual
REDEEM YOUR FREE CLEANING KIT
Register your product at marvelrefrigeration.com to receive (1) S41016346-ACCY
Nugget Ice Cleaning Kit at no charge.
- Valid on Marvel Nugget ice Machines produced after September 2021.
THE ORIGINAL REFRIGERATION EXPERTS SINCE 1892
Welcome to the Marvel Experience
Thank you for choosing our quality American-built product to add to your home.
We are thrilled to welcome you to our growing community of Marvel owners, who
trust in our products and our support.
The information in this guide is intended to help you install and maintain
your new Marvel under-counter model to protect and prolong its lifetime. We
encourage you to contact our Technical Support team at
616-754-5601 with any questions.
Got a Marvelous Design?
We would love to see how your Marvel product looks in its new home. Send us
photos at
marketing@marvelrefrigeration.com,
and we might feature your Marvel home design on our website and social media!
Thank you again for investing in Marvel for your home!
Important Safety Instructions
Warnings and safety instructions appearing in this guide are not meant to
cover all possible conditions and situations that may occur. Common sense,
caution, and care must be exercised when installing, maintaining, or operating
this appliance.
Recognize Safety Symbols, Words, and Labels.
WARNING
WARNING – You can be killed or seriously injured if you do not follow
these instructions.
CAUTION
CAUTION-Hazards or unsafe practices that could result in personal injury
or property/product damage.
NOTE
NOTE-Important information to help assure a problem-free installation and
operation.
WARNING
State of California Proposition 65 Warning:
This product contains one or more chemicals known to the State of California
to cause birth defects or other reproductive harm.
WARNING
State of California Proposition 65 Warning:
This product contains one or more chemicals known to the State of California
to cause cancer.
WARNING
WARNING - This unit contains R600a (Isobutane) which is a flammable
hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite
defrosting. Do not damage the refrigerant circuit.
UNPACKING YOUR APPLIANCE
WARNING
EXCESSIVE WEIGHT HAZARD
Use two or more people to move the product.
Failure to do so can result in personal injury.
Remove Interior Packaging
Your appliance has been packed for shipment with all parts that could be
damaged by movement securely fastened.
Remove internal packing materials and any tape holding internal components in
place. The owner’s manual is shipped inside the product in a plastic bag along
with the warranty registration card, and other accessory items.
Important
Keep your carton and packaging until your appliance has been thoroughly
inspected and found to be in good condition. If there is damage, the packaging
will be needed as proof of damage in transit. Afterward please dispose of all
items responsibly.
WARNING
WARNING – Dispose of plastic bags which can be a suffocation hazard.
Note to Customer
This merchandise was carefully packed and thoroughly inspected before leaving
our plant. Responsibility for its safe delivery was assumed by the retailer
upon acceptance of the shipment. Claims for loss or damage sustained in
transit must be made to the retailer.
NOTE
DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER – FILE THE CLAIM WITH
THE RETAILER.
CAUTION
If the appliance was shipped, handled, or stored in other than an upright
position for any period of time, allow the appliance to sit upright for a
period of at least 24 hours before plugging in. This will assure oil returns
to the compressor. Plugging the appliance in immediately may cause damage to
internal parts.
Warranty Registration
It is important you send in your warranty registration card immediately after
taking delivery of your appliance or you can register online at
www.marvelrefrigeration.com.
The following information will be required when registering your appliance.
Service Number———-
Serial Number————
Date of Purchase————-
Dealer’s name and address———
The service number and serial number can be found on the serial plate which is
located inside the cabinet on the left side near the top. See figure 1.
WARNING
WARNING – Help Prevent Tragedies
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous – even if they sit out for “just a
few hours”.
If you are getting rid of your old refrigerator, please follow the
instructions below to help prevent accidents.
Before you throw away your old refrigerator or freezer:
- Take off the doors or remove the drawers.
- Leave the shelves in place so children may not easily climb inside.
INSTALLING YOUR APPLIANCE
Select Location
The proper location will ensure the peak performance of your appliance. We
recommend a location where the unit will be out of direct sunlight and away
from heat sources. To ensure your product performs to specifications, the
recommended installation location temperature range is from 50 to 100°F (10 to
38°C).
Cabinet Clearance
Ventilation is required from the bottom front of the appliance. Keep this area
open and clear of any obstructions. Adjacent cabinets and countertops can be
installed around the appliance as long as the front grille remains
unobstructed. All Marvel Professional models with articulated hinges are
intended for built-in applications only.
CAUTION
Front Grille
Do not obstruct the front grille. The openings within the front grille allow
air to flow through the condenser heat exchanger. Restrictions to this airflow
will result in increased energy usage and loss of cooling capacity. For this
reason, it is important this area not be obstructed and the grille openings
kept clean. Marvel does not recommend the use of a custom-made grille as
airflow may be restricted.
Leveling Legs
Adjustable legs at the front and rear corners of the appliance should be set
so the unit is firmly positioned on the floor and level from side to side and
front to back. The overall height of your Marvel appliance may be adjusted
higher (by turning the leveling leg out, CCW) and lower (by turning the
leveling leg in, CW).
To adjust the leveling legs, place the appliance on a solid surface and
protect the floor beneath the legs to avoid scratching the floor. With the
assistance of another person, lean the appliance back to access the front
leveling legs. Raise or lower the legs to the required dimension by turning
the legs. Repeat this process for the rear by tilting the appliance forward
using caution. On a level, the surface checks the appliance for levelness and
adjusts accordingly.
WARNING
Electrical Shock Hazard
- Do not use an extension cord with this appliance. They can be hazardous and can degrade product performance.
- This appliance should not, under any circumstances, be installed to an un-grounded electrical supply.
- Do not remove the grounding prong from the power cord. (See Figure 3).
- Do not use an adapter. (See Figure 4).
- Do not splash or spray water from a hose on the appliance. Doing so may cause an electrical shock, which may result in severe injury or death.
ELECTRICAL
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that has a three-
pronged, grounded plug. It must be plugged into a mating grounding type
receptacle in accordance with the National Electrical Code and applicable
local codes and ordinances (see Figure 6). If the circuit does not have a
grounding-type receptacle, it is the responsibility and obligation of the
customer to provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance tripping which
will cause the appliance to shut down. GFCIs are generally not used on
circuits with power equipment that must run unattended for long periods of
time unless required to meet local building codes and ordinances.
CUTOUT & PRODUCT DIMENSIONS
PREPARE SITE
CAUTION
Your product has been designed for either free-standing or built-in
installation. When built-in, your unit does not require additional air space
for the top, sides, or rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical connection in the rear.
CAUTION
The unit can NOT be installed behind a closed cabinet door. If you would
like to align the face of the unit with other adjacent cabinet doors, you may
need to alter the wall just behind the drain connection on the unit to
accommodate the drain.
CUTOUT DIMENSIONS – MSNP115
*15″ cutout width may be sufficient if the opening is exact and square.
PRODUCT DIMENSIONS
|
---|---
|
CUTOUT DIMENSIONS – MLNP115
PRODUCT DIMENSIONS
|
---|---
|
DOOR ADJUSTMENTS
Grille Installation
REMOVING AND INSTALLING GRILLE
WARNING
WARNING - Disconnect electric power to the unit before removing the
grille. When using the unit, the grille must be installed.
WARNING
WARNING - DO NOT touch the condenser fins. The condenser fins are SHARP
and can be easily damaged.
Removing the grille
- Disconnect power to the unit.
- Loosen the two screws (1).
- Remove grille (2) from the unit.
Installing the grille
- Align cabinet and grille holes and secure, but do not over-tighten grille screws (1).
- Reconnect power to the unit.
Door Swing
Units have a zero clearance for the door to open 90°, when installed adjacent
to cabinets.
Stainless steel models require 2-1/8″ (54 mm) door clearance to accommodate
the handle if installed next to a wall.
Door Adjustments
HINGE COVER
The hinge cover included with the literature bag is optional.
To Install hinge cover:
• Press hinge cover squarely over the hinge.
Door Alignment and Adjustment
Align and adjust the door if it is not level or is not sealing properly. If
the door is not sealed, the unit may not cool properly, or excessive frost may
form in the interior.
NOTE
Properly aligned, the door’s gasket should be firmly in contact with the
cabinet all the way around the door (no gaps). Carefully examine the door’s
gasket to ensure that it is firmly in contact with the cabinet. Also, make
sure the door gasket is not pinched on the hinge side of the door.
To align and adjust the door – MSNP115
- Gently pry off the hinge cover from the top of the unit.
- Loosen (do not remove) top and bottom hinge screws using a Torx T-25 screwdriver.
- Align door squarely with cabinet.
- Make sure the gasket is firmly in contact with the cabinet all the way around the door (no gaps).
- Tighten bottom hinge screws.
- Tighten top hinge screws and replace hinge cover.
Reversing the Door
The location of the unit may make it desirable to mount the door on the
opposite side of the cabinet.
The hinge hardware will be removed and reinstalled on the opposite side of the
cabinet.
TO REVERSE THE DOOR
Remove top hinge door:
- Hold the door to keep it from falling.
- Remove the top hinge from the cabinet using a Torx T-25 screwdriver to remove three screws. Set aside and save for possible future use.
- Remove the door by tilting forward and lifting the door off the bottom hinge. Retain shoulder washers; they will be reused.
- Remove three screws from hinge holes on the opposite side. Reinstall into holes where the hinge was removed. (If utilizing supplied screw cover, install just one screw.)
Remove bottom hinge:
- Remove the bottom hinge from the cabinet using a T-10 TORX screwdriver to remove three screws.
- Remove corresponding screws on opposite sides of the cabinet. On some models, there may be a nut behind one or both screws on either side.
Install bottom hinge:
Install two or three screws, depending on the model. Replace nuts if used.
Door Adjustments – MLNP115 & MPNP415
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or not sealing properly. If the
door is not sealed, the unit may not cool properly, or excessive frost or
condensation may form in the interior.
NOTE
Properly aligned, the door’s gasket should be firmly in contact with the
cabinet all the way around the door (no gaps). Carefully examine the door’s
gasket to ensure that it is firmly in contact with the cabinet. Also, make
sure the door gasket is not pinched on the hinge side of the door.
CAUTION
Do not attempt to use the door to raise or pivot your unit. This would put
excessive stress on the hinge system.
Alignment and Adjustment Procedure
- Open the door and remove the gasket near the hinges.
- Using a T-25 Torx bit, loosen each pair of Torx head screws on both the upper and lower hinge plates.
- Square and align door as necessary.
- Tighten Torx head screws on the hinge.
- Reinstall the gasket into the channel starting at the corner.
DOOR REVERSAL
REVERSING THE DOOR
-
Open the door.
-
Using a T-25 Torx bit loosen screw #1 and remove screw #2 on the top and bottom hinge. Slide and remove the door from the unit. NOTE
One hinge includes a metal spacer. The spacer must be used with that hinge when reversing the door. -
Remove caps from screw heads on the opposite sides (2 on top and 2 on bottom). Using #2 Phillips bit, remove the 4 underlying screws. Reinstall the screws and caps on the opposite side.
-
Partially install screw #1 in the outermost holes on top and bottom. Rotate door 180º, align hinge over screw #1, and slide/seat into position. Reinstall screw #2 on top and bottom. Tighten both screws and install the hinge cover.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND ADJUSTMENT).
Prepare door for reinstallation:
- Remove gasket. This will reveal mounting holes for the magnet assembly.
- Remove magnet assembly from the door with the T-10 TORX driver. Be sure to only remove the two screws holding the assembly to the door. Reinstall on the opposite end of the door.
- Rotate the gasket 180°, aligning the notch with magnet assembly and pressing firmly into the gasket channel starting at the corners.
- Rotate door 180° to reverse.
Install top hinge and door:
- Install hinge with a long straight edge aligned to the outside edge of the cabinet. Do not tighten.
- Lift the door onto the bottom hinge.
- Align the edge of the hinge with the outer edge of the unit.
- Tighten three hinge screws.
INSTALLING THE ANTI-TIP DEVICE
Anti-Tip Bracket – MSNP115
- Slide unit out so screws on top of unit are easily accessible.
- Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below).
- Place the bracket over the holes and attach it to the unit with two screws removed in step 2 using a T-25 Torx driver. Tighten screws fully.
- Gently push the unit into position. Be careful not to entangle the electrical cord or water line, if applicable.
- Check to be sure the unit is level from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1⁄8” (3 mm)below the countertop.
- Secure bracket onto the adjoining surface.
Anti-Tip Bracket – MLNP115
Use one of the methods below to secure the unit
CABINET/COUNTER ANTI-TIP INSTALLATION
(For built-in applications)
- Slide the unit out so screws on the front of the unit are easily accessible.
- Remove the two screws from the front of the unit.
- Bend bracket along one of the perforations to allow attachment to the desired adjoining surface.
- Gently push the unit into position. Be careful not to entangle the electrical cord or water line, if applicable.
- Check to be sure the unit is level from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8” (3 mm) below the countertop.
- Secure bracket to adjoining surface.
Leveling Information
- Use a level to confirm the unit is level. The level should be placed along the top edge and side edge as shown.
- If the unit is not level, adjust the legs on the corners of the unit as necessary.
- Confirm the unit is level after each adjustment and repeat the previous steps as needed.
NOTE
If the room floor is higher than the floor in the cutout opening, adjust the
rear legs to achieve a total unit rear height of 1⁄8” (3 mm) less than the
opening’s rear height. Shorten the unit height in the front by adjusting the
front legs. This allows the unit to be gently tipped into the opening.
Readjust the front legs to level the unit after it is correctly ositioned in
the opening.
Installation
- Plug in the power/electrical cord.
- Gently push the unit into position. Be careful not to entangle the cord or water and drain lines, if applicable.
- Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1⁄8” (3 mm) below the countertop.
- Install the anti-tip bracket.
- Remove interior packing material and wipe out the inside of the unit with a clean, water-dampened cloth.
INTEGRATED PANEL INSTALLATION
Panel Installation
MLNP115-IS01A & MPNP415-IS81A
3/4″ (20 mm) panel
14 15/16” (379 mm) width
30″ (762 mm) height
-
Fully open door.
-
Starting at a corner, pull the gasket away from the door.
-
Continue to pull the gasket free from the gasket channel.
-
Upon removal, lay the gasket down on a flat surface.
-
Align the top of the panel with the top edge of the door. Center panel on the door.
NOTE
Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the door. -
Secure integrated panel to door using clamps. A robust tape may also be used. Marvel recommends the use of bar clamps to secure the panel to the door. If using tape, be certain the tape will not damage the panel finish upon removal.
-
Using a 7/64” (3 mm) drill bit, drill 6 pilot holes into the wood panel 1/2” (12 mm) deep using the holes in the door frame as a guide.
NOTE
It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed. -
Locate 6 of the #6x 1-1/2” (38 mm) screws provided with your unit.
-
Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws.
-
Ensure the screws sit flush against the bottom of the channel.
-
Remove clamps from the door.
NOTE
If the panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust the panel as necessary. Tighten screws upon completion. -
Starting at the corners, re-install the gasket into the gasket channel in the frame. Make sure the gasket is fully seated.
INSTALLING THE DRAIN PLUMBING
Drain
This model comes equipped with a factory-installed drain pump.
CONNECT DRAIN LINE
CAUTION
Failure to connect water supply or drain line connections properly can result
in personal injury and property damage. See below for typical installations
requiring a drain pump.
Stand Pipe
Disposal Assembly
Y-Branch Tail Piece
INSTALLING THE WATER SUPPLY
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4″ (6.35 mm) compression fitting.
CAUTION
Plumbing installation must observe all state and local codes. All water and
drain connections MUST BE made by a licensed/qualified plumbing contractor.
Failure to follow recommendations and instructions may result in damage and/or
harm.
Water Supply Connection
When connecting the water supply, please note the following:
- A TDS meter is included with your unit
- Water Treatment Options
- TDS between 400-600 and/or hardness between 13-20 can be treated by Marvel’s in-line water filter accessories available at marvelrefrigeration.com or your local dealer:
- S41016343 ACCY – Standard
- S41016344 ACCY – Large
- S41016345 ACCY – Filter head 3/8″ NPT, initial setup requires head & filter
- Use bypass level 6
Water Quality | 1-3 Users | 4+ Users |
---|---|---|
400 TDS and/or 12 gpg hardness or less | Optional |
Standard Filter
Change lx per year| Optional
Large Filter Change lx per year
401-600 TDS and/or 13-20 gpg hardness| Required
Large Filter Change lx per year| Required
Large Filter Change 2x per year
601 + TDS, and/or 21 + gpg hardness| Contact your local
water professional| Contact your local
water professional
WARNING
WARNING- Connect to potable water supply only.
- Water Mineral Content:
- TDS: greater than 5 ppm (mg/I) but less than 400 ppm (m91)
- Hardness: less than 200 mg/I (12 gpg)
- Not recommended for use with softened water
Do not use any plastic water supply line. The line is under pressure at all
times. Plastic may crack or rupture with age and cause damage to your home. Do
not use tape or joint compound when attaching a braided flexible water supply
line that includes a rubber gasket The gasket provides an adequate seal —
other materials could cause blockage of the valve. Failure to follow
recommendations and instructions may result in damage and/or harm, flooding,
or voiding of the product warranty. Use a new hose set. Do not reuse the old
hose set.
CAUTION
Turn off the water supply and disconnect the electrical supply to the unit
prior to installation. Use caution when handling the back panel. The edges
could be sharp.
- Turn off the water supply and disconnect the electrical supply to the product prior to attempting installation.
- Remove the back panel.
- Thread water line through back panel hole (with bushing).
- Locate the water valve inlet and connect it to the valve.
- Turn on the water supply and check for leaks.
- Reinstall the back panel.
OPERATION OF ICE MACHINE
First Use
Initial startup requires no adjustments. When plugged in, the unit will begin
operating under the factory default settings. If the unit was turned off
during installation, simply press and the unit will immediately switch on. To
turn the unit off, press .
NOTE
The temperature displayed reflects the actual temperature inside the unit.
If the temperature displayed is different from than selected, the unit is
progressing toward the selected temperature. The time to reach the set point
varies based upon ambient temperature, the temperature of product loaded, door
openings, etc. Marvel recommends allowing the unit to reach set points before
loading.
Ice
The Nugget Ice Machine produces cylindrical bits of compressed ice
approximately 3/4” x 1/2”.
Ice is produced until the machine senses the bin is full. As the ice slowly
melts in the bin, the level of ice drops, and ice production resumes. This
ensures a constant supply of fresh ice is always available.
The factory’s default ice setting is 0, which produces a firm and compact ice
nugget. Our ice adjustability feature allows you five levels of adjustment
from 0 to -5. At -5 the ice is soft and chewable.
To adjust the ice density:
1. Hold for 5 seconds – the display will flash the current ice setting.
2. Adjust using or .
3. Confirm the setting by pressing .
USING YOUR ELECTRONIC CONTROL
CONTROL FUNCTION GUIDE
FUNCTION | COMMAND | NOTES |
---|---|---|
ON/OFF | Press and release. | The unit will immediately turn On or OFF. |
Adjust Ice Density | See the “Ice” section. | |
Enable Sabbath Mode | Press and hold for 5 seconds and release. | The ºF/ºC |
symbol will flash briefly after 5 seconds. Interior light and the display will
go dark and remain so until the user resets mode – the unit continues to
operate.
Disable Sabbath Mode| Press and release.| Display and interior light return
to normal operation.
Clean Mode| See the “Cleaning” section.|
Showroom Mode| Hold and for 5 seconds.| The ºF/ºC symbol will flash. The
display will be lit and interior light with function. The unit will not
cool. Repeat command to return to normal operation.
DOOR ALERT NOTIFICATION
When the door is left open for more than 30 minutes:
- Ice production will cease
- A tone will sound for several seconds every minute
- will appear on the display
Close door to silence alert and reset (Ice production will resume if bin
sensor is not satisfied)
Airflow and Product Loading
NOTE
The unit requires proper airflow to perform at its highest efficiency. Do not
block the front grille at any time, or the unit will not perform as expected.
Do not install the unit behind a door.
USING YOUR ELECTRONIC CONTROLS – MPNP415 MODELS ONLY
Control Function Guide
Function | Command | Notes |
---|---|---|
ON/OFF | Press and release. | The unit will immediately turn ON or OFF. |
Adjust light color | Hold and press and release . Press to scroll through | |
lighting options. | Option | |
--- | --- | --- |
White | White | |
BrightShieldTM | BrightShieldTM | |
(default) White | BrightShieldTM | |
Toggle interior light – Door Closed | Press and release to toggle the interior | |
light option; press again to deactivate | The toggle depends on the light color |
option above. Light output 50%
Adjust ice density| See the “Ice” section|
Enable Sabbath Mode| Press and hold for 5 seconds and release| The ºF/ºC
symbol will flash briefly after 5 seconds. Interior light and the display will
go dark and remain so until the user resets mode – the unit continues to
operate
Disable Sabbath Mode| Press and release| Display and interior light return to
normal operation
Clean Mode| See the “Cleaning” section|
Showroom Mode| Hold and for 5 seconds| The ºF / ºC symbol will flash. The
display will be lit and interior light will function. The unit will not cool.
Repeat command to return to normal operation
Door Alert Notification
When the door is left open for more than 30 minutes:
- A tone will sound for several seconds every minute
- will appear on the display
- Close door to silence alert and reset
USING YOUR ELECTRONIC CONTROLS – MPNP415 MODELS ONLY
BrightShield™
This model includes BrightShield™ with Vyv™ Antimicrobial Light Technology.
BrightShield™
-
Kills* and prevents the growth of viruses, bacteria, fungi, yeasts, mold, and mildew
-
Provides continuous antimicrobial action to keep surfaces clean
-
Is approved for continuous use around people, pets, & plants
-
Reduces odors caused by bacteria, fungi, yeasts, mold, and mildew
-
Creates a cleaner environment for food, beverages, & ice
-
Testing on a non-enveloped virus (MS2 bacteriophage) showed a 97.12% reduction in controlled laboratory testing in 8 hours on hard surfaces. Testing on SARS-CoV-2 (enveloped virus) showed a 98.45% reduction in controlled laboratory testing in 4 hours on hard surfaces. Testing on MRSA E. coli showed a 90%+ reduction in controlled laboratory testing in 24 hours on hard surfaces. Results may vary depending on the amount of light that is reaching the surfaces in the space
BrightShield™ is most effective when used continuously. Your unit is factory- set to use BrightShield™ lighting whenever the door is closed and standard bright white when the door is open. See the Control Operations sections for details and other options.
For more information about BrightShield™ visit www.marvelrefrigeration.com
For more information about Vyv™ Antimicrobial Light Technology visit www.vyv.tech
CLEANING YOUR ICE MACHINE
Cleaning
EXTERIOR CLEANING
Stainless steel can discolor when exposed to chlorine gas, pool chemicals,
saltwater, or cleaners with bleach. Keep your stainless unit looking new by
cleaning with a good quality all-in-one stainless steel cleaner and polish
monthly. For best results use Claire® Stainless Steel Polish and Cleaner.
Comparable products are acceptable. Frequent cleaning will remove surface
contamination that could lead to rust. Some installations may require cleaning
weekly.
CAUTION
Do not clean with steel wool pads. Do not use cleaners not specifically
intended for stainless steel on stainless steel surfaces (this includes glass,
tile, and counter cleaners).
If any surface discoloring or rusting appears, clean it quickly with Bon-Ami®
or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the
grain. Always finish with Claire® Stainless Steel Polish and Cleaner or
comparable product to prevent further problems.
CAUTION
Using abrasive pads such as ScotchBrite™ will cause the graining in the
stainless steel to become blurred. Rust not cleaned up promptly can penetrate
the surface of the stainless steel and complete removal of the rust may not be
possible.
INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a mild non-abrasive
detergent and warm solution applied with a soft sponge or non-abrasive cloth.
Rinse the interior using a soft sponge and clean potable water.
CAUTION
Do not use any solvent-based or abrasive cleaners. These types of cleaners may
transfer taste and/or odor to the interior products and damage or discolor the
interior.
NUGGET ICE MACHINE CLEANING CYCLE
This ice machine has an automatic clean alert function. The control will
indicate in the display, approximately every six months with normal use,
reminding you to clean your unit. When is displayed, ice production will
continue. Depending on water conditions, more frequent cleaning may be
necessary. Cleaning removes lime scale, and other mineral deposits, and
sanitizes the machine. Poor ice quality and reduced ice output are signs that
cleaning is necessary. If the machine consistently requires more frequent
cleaning, consult a plumber to test the water quality and recommend the
appropriate treatment.
TDS (Total Dissolved Solids) Level mg/L (ppm) | Cleaning Interval |
---|---|
5 – 150 | 6 months |
150 – 250 | 4 months |
250 – 400 | 3 months (or sooner) |
Hardness Level mg/L (ppm) | Cleaning Interval |
0 – 66 | 6 months |
67 – 133 | 4 months |
134 – 200 | 3 months (or sooner) |
Under normal conditions cleaning should be done when the display shows . You
may initiate a cleaning cycle at any time by pressing and holding the clean
button for 10 seconds. will appear in the display indicating the start of the
cleaning process.
Failure to clean may reduce the quality and quantity of ice produced. Once the
clean cycle begins, it can be canceled by pressing three times. Press once
more to start making ice. The clean cycle will automatically cancel if the
user fails to activate control at steps 2, 3b, and 5b within 2 hours.
Required for cleaning:
- Clean potable water
- Bucket and cleaning sponge
- Internal water filter (if applicable) —S41016405-ACCY
- safe clean Plus™ Cleaner — S41015681
- Hose (7⁄16” ID x 9⁄16” OD) and funnel
◦ Register your product at marvelrefrigeration.com and receive a free cleaning kit – S41016346-ACCY (cleaner, hose, & funnel)
Available for purchase at marvelrefrigeration.com or your local dealer
Need more cleaner? Call Marvel Customer
Service at 616.754.5601.
CAUTION
Use only SafeCLEAN Plus™ Cleaner. The use of any other cleaner may damage
the finish of the evaporator and will void the warranty. Follow safety and
handling instructions printed on the SafeCLEAN Plus™ bottle.
NOTE**
Select models include a water filter. The filter must remain in place when
using and cleaning the machine. The filter is designed to filter out scale,
sediment, particles, and cloudiness as well as reduce chlorine and other off
tastes and odors. Marvel recommends replacing the filter (Part No.
S41016405-ACCY) when you clean your machine. The filter is available at
marvelrefrigeration.com.
-
Press and hold for 10 seconds
a. will appear in the display
b. Remove access shield
c. Remove all ice in bin
d. Remove any ice protruding from the ice dispenser tube. -
Insert the end of the cleaning tube into the ice dispenser; slowly pour in approximately 1 quart of hot (min. 100º F) potable water. This will melt the ice inside the dispenser tube. It is normal for some water to flow from the ice dispenser tube and exit from the vent tube while pouring. Omit this step if no ice is in the ice dispenser tube.
-
Press and release
a. will appear in the display
b. Mix 4 ounces of SafeCLEAN Plus™ with 2 quarts of potable water. -
Wait until appears in the display
a. Using the funnel and cleaning tube, slowly pour 3⁄4 of the cleaning solution into the dispenser tube. Air and some water will exit the vent tube. Remove cleaning tube.
b. Press and release -
will appear in the display
a. The machine will circulate the solution, cleaning and sanitizing the internal components, for approximately 20 minutes.
b. While the machine is circulating the cleaning solution, use 1/2 of the remaining cleaning solution and a sponge to wipe down the inside of the ice bin and scoop. Rinse with clean potable water. -
When appears in the display, 3 soft tones will sound, indicating the cleaning phase is complete.
• Using the hose and funnel, slowly pour 1.5 quarts (48 oz.) of clean potable water into the ice dispenser tube. Air and some water will exit the vent tube. -
will appear in the display
a. Reinstall shield and close door.
b. The machine will circulate water and perform a series of final rinses for approximately 15 minutes.
c. The unit will resume making ice – indicated by 3 tones and scrolling in the display.
d. Discard the first 10 minutes of ice production.
Cleaning Condenser
INTERVAL – EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille free of dust and
lint, and clean the condenser when necessary. Depending on environmental
conditions, more or less frequent cleaning may be necessary.
WARNING
WARNING - Connect to potable water supply only.
NOTE
DO NOT use any type of cleaner on the condenser unit.
The condenser may be cleaned using a vacuum, soft brush, or compressed air.
- Remove the grille (See GRILLE INSTALLATION).
- Clean the condenser coil using a soft brush or vacuum cleaner.
- Install the grille.
CARE AND CLEANING
Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN
The following steps are recommended for periods of extended non-use:
- Remove all consumable content from the unit.
- Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service.
- Turn off the water supply.
- If ice is on the evaporator, allow ice to thaw naturally.
- Clean and dry the interior of the unit. Ensure all water has been removed from the unit.
- Disconnect the water and drain line (if applicable) Make sure all water is removed from the lines.
- The door must remain open to prevent the formation of mold and mildew. Open the door a minimum of 2” (50 mm) to provide the necessary ventilation.
WINTERIZATION
If the unit will be exposed to temperatures of 40ºF (5ºC) or less, the steps
above must be followed. In addition, P60 drain pumps must be trained according
to the following procedure:
- Remove the drain pump from the ice machine.
- Drain the water in the pump’s reservoir by turning the pump upside down and allowing the water to drain through the pump’s inlet and vent tube fittings.
- After the water is drained, reinstall the drain pump and reattach all connections.
For questions regarding winterization, please call Marvel Refrigeration at
616.754.5601
CAUTION
Damage caused by freezing temperatures is not covered by the warranty. Do not
put anti-freeze in your unit.
OBTAINING SERVICE
If Service is Required:
- If the product is within the first year warranty period please contact your dealer or call Marvel Customer Service at 800.223.3900 for directions on how to obtain warranty coverage in your area.
- If the product is outside the first year warranty period, Marvel Customer Service can provide recommendations of service centers in your area. A listing of authorized service centers is also available at www.marvelrefrigeration.com under the service and support section.
- In all correspondence regarding service, be sure to give the service number, serial number, located on your product’s serial plate, and proof of purchase.
- Try to have information or description of the nature of the problem, how long the unit has been running, the room temperature, and any additional information that may be helpful in quickly solving the problem.
- The table below is provided for recording pertinent information regarding your product for future use. 616.754.5601
For Your Records
Date of Purchase|
Dealer’s name|
Dealer’s Address|
Dealer’s City|
Dealer’s State|
Dealer’s Zip Code|
Appliance Serial Number|
Appliance Service Number|
HOUSEHOLD PRODUCT WARRANTY
Marvel Refrigeration (Marvel) Limited Warranty
ONE-YEAR LIMITED PARTS & LABOR WARRANTY
For one year from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All services provided by Marvel under the above warranty must be performed by
a Marvel factory-authorized servicer unless otherwise specified by Marvel.
Service provided during normal business hours.
TWO-YEAR LIMITED PARTS & LABOR WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For two years from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All services provided by Marvel under the above warranty must be performed by
a Marvel factory-authorized servicer unless otherwise specified by Marvel.
Service provided during normal business hours.
AVAILABLE THIRD-YEAR LIMITED WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For designated Marvel Professional products, Marvel offers a one-year
extension of the two-year warranty coverage from the date of purchase, free of
charge. To take advantage of this third-year warranty, you must register your
product with Marvel within 60 days from the date of purchase at
marvelrefrigeration.com and provide proof of purchase.
LIMITED FIVE-YEAR SEALED SYSTEM WARRANTY
For five years from the date of original purchase, Marvel will repair or
replace the following parts, labor not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All services provided by Marvel under the above warranty
must be performed by a Marvel factory-authorized servicer unless otherwise
specified by Marvel. Service provided during normal business hours.
WARRANTY TERMS
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, installation,
service, repair, acts of God, fire, flood, or other natural disasters. The
product must be installed, operated, and maintained in accordance with the
Marvel User Guide.
The remedies described above for each warranty are the only ones that Marvel
will provide, either under these warranties or under any warranty arising by
operation of law. Marvel will not be responsible for any consequential or
incidental damages arising from the breach of these warranties or any other
warranty, whether express, implied, or statutory. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. These warranties give you
specific legal rights, and you may also have other rights which vary from
state to state.
Any warranty that may be implied in connection with your purchase or use of
the product, including any warranty of merchantability or any warranty fit for
a particular purpose is limited to the duration of these warranties and only
extends to five years in duration for the parts described in the section
related to the five-year limited warranty above. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
- The warranties only apply to the original purchaser and are non-transferable.
- These warranties cover products installed and used for normal residential use only.
- The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
- Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
- The start of Marvel’s obligation is limited to four years after the shipment date from Marvel.
- In-home instruction on how to use your product is not covered by these warranties.
- Food, beverage, and medicine loss are not covered by these warranties.
- If the product is located in an area where Marvel factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a Marvel factory authorized service location at your own cost and expense.
- Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one-year warranty only and no coverage is provided for cosmetic defects.
- Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find Marvel factory authorized service
near you, contact Marvel Refrigeration:
MarvelRefrigeration.com
•
techsupport@MarvelRefrigeration.com
• +616.754.5601
1260 E. Van Deinse St., Greenville, MI 48838
www.marvelrefrigeration.com
Marvel Refrigeration
1260 E. Van Deinse St.
Greenville MI 48838
616.754.5601
30668 Rev C
3/8/2022
All specifications and product designs are subject to change without notice.
Such revisions do not entitle the buyer to corresponding changes,
improvements, additions, replacements, or compensation for previously
purchased products.
References
- The domain name ATION.COM is for sale | Dan.com
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>