Paslode T250S-F16P 16 Gauge Straight Finish Nailer User Manual
- June 5, 2024
- Paslode
Table of Contents
Paslode T250S-F16P 16 Gauge Straight Finish Nailer
INTRODUCTION
The PASLODE® T250S-F16P finish nailer is a quality-built tool designed for use in residential trim applications. This tool will deliver efficient, dependable performance when used according to the manufactures guidelines. Please study this manual including the safety instructions to fully understand the operation of this tool.
TOOL WARRANTY AND LIMITATIONS
Paslode warrants that newly purchased power fastening tools, parts and accessories will be free from defects in material and workmanship for the period shown below, after the date of delivery to the original user.
ONE-YEAR FULL WARRANTY
A one-year warranty will apply to all parts, except those which are
specifically covered by an extended warranty.
FIVE-YEAR EXTENDED LIMITED WARRANTY
A five-year warranty will apply to all housing and cap assembly castings.
WARRANTY STATEMENT
This warranty is limited to tools sold and service requested in the United
States. To obtain information on warranty service in the United States, refer
to the Service Center listing that was provided with your tool.
Paslode’s sole liability hereunder will be to replace any part or accessory
which proves to be defective within the specific time period. Any replacement
part or accessory provided in accordance with this warranty will carry a
warranty for the balance of the period of warranty applicable to the part it
replaces. This warranty does not apply to part replacement required due to
normal wear.
This warranty is void as to any tool which has been subjected to misuse,
abuse, accidental or intentional damage, use with fasteners,not meeting
Paslode specification, size, or quality, PASLODE MAKES NO WARRANTY,
EXPRESSED OR IMPLIED, RELATING TO MERCHANTABILITY, FITNESS, OR OTHERWISE, EXCEPT AS STATED ABOVE, and Paslode’s liability AS STATED ABOVE AND AS ASSUMED ABOVE is in lieu of all other warranties arising out of, or in connection with, the use and performance of the tool, except to the extent other wise provided by applicable law. PASLODE SHALL IN NO EVENT BE LIABLE FOR ANY
DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, DAMAGES WHICH MAY ARISE FROM LOSS OF ANTICIPATED PROFITS OR PRODUCTION, SPOILAGE OF MATERIALS, INCREASED COST OF OPERATION, OR OTHERWISE.
TOOL AND FASTENER SPECIFICATIONS
TOOL SPECIFICATIONS
MODEL NO. | T250S-F16P (Part# 515500) |
---|---|
HEIGHT | 11.6″ |
WIDTH | 2.9″ |
LENGTH | 12.3″ |
WEIGHT
OPERATING PRESSURE
| 3.9lbs.
80 to 120 p.s.i. (5.5 to 8.3 bars)
FASTENER SPECIFICATIONS
NAIL LENGTH | 1″ – 2-½” |
---|---|
SHANK DIAMETER | 16 gauge |
TOOL AIR FITTINGS:
This tool uses a 1/4” N.P.T. male plug. The inside diameter should be .28”
(7mm) or larger. The fitting must be capable of discharging tool air pressure
when disconnected from the air supply.
OPERATING AIR PRESSURE:
80 to 120 p.s.i. (5.5 to 8.3 bars). Select the operating air pressure within
this range for best tool performance.
DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.
SAFETY INSTRUCTIONS
SAFETY FIRST
These safety instructions provide information necessary for safe operation of
Paslode® tools. DO NOT ATTEMPT TO OPERATE THE TOOL UNTIL YOU READ AND
UNDERSTAND ALL SAFETY PRECAUTIONS AND MANUAL INSTRUCTIONS.
WEAR EYE AND HEARING PROTECTION
Always wear hearing and eye protection devices, that conform to ANSI Z87.1
requirements, when operating or working in the vicinity of a tool. As an
employer you are responsible for enforcing the use of eye protection. Wear
hard hats in environments that require their use.
THE TOOL MUST BE USED ONLY FOR THE PUR-POSE FOR WHICH IT WAS DESIGNED
Do not throw the tool on the floor, strike the housing in any way or use the
tool as a hammer to knock material into place.
NEVER ENGAGE IN HORSEPLAY WITH THE TOOL
The tool is not a toy so do not use it like one. Never engage in horseplay
with the tool or point it at yourself or any other person, even if you think
it is not loaded.
NEVER ASSUME THE TOOL IS EMPTY
Check the magazine for fasteners that may be left in the tool. Even if you
think the tool is empty or disconnected, never point it at anyone or yourself.
Unseen fasteners could fire from the tool.
NEVER CLAMP THE TRIGGER IN A LOCKED OR OPERATING POSITION
The trigger of the tool must never be tampered with, disabled or clamped in a
locked or operating position since this will cause the tool to drive a
fastener any time the work contacting element depressed.
DO NOT LOAD FASTENERS WITH THE AIR LINE CONNECTED, OR WITH THE TOOL TRIGGER
OR WORK CONTACTING ELEMENT DEPRESSED
When loading fasteners into the tool be sure you disconnect the air line and
that you do not depress the trigger or work contacting element.
OPERATE THE TOOL ONLY ON A WORKPIECE
The tool should be operated only when it is in contact with the workpiece.
Even then you should be careful when fastening thin material or working near
the edges and corners of the workpiece since the fasteners may drive through
or away from the workpiece.
DO NOT DISABLE OR REMOVE THE WORK CONTACTING ELEMENT
This tool is equipped with a safety mechanism, called a work contacting
element, to help prevent accidental firing. Never tamper with, disable or
remove the work contacting element. Do not use the tool unless the work
contacting element is working properly. The tool could fire unexpectedly.
DISCONNECT THE TOOL WHEN NOT IN USE
Always disconnect the tool from the air line when it is not in use, when you
leave the work area or when moving the tool to a new location. The tool must
never be left unattended because people who are not familiar with the tool
might handle it and injure themselves or others.
CARRY THE TOOL ONLY BY THE HANDLE
Always carry the tool by the handle only. Never carry the tool by the air hose
or with the trigger depressed since you could drive a fastener unintentionally
and injure yourself or someone else.
DO NOT WEAKEN THE TOOL HOUSING
The tool housing is a pressure vessel and should never be weakened by having
your companyʼs name, area of work or anything else stamped or engraved into
its surface.
DISCONNECT THE TOOL WHEN PERFORMING REPAIRS AND CLEARING JAMS
Never attempt to clear a jam or repair a tool unless you have disconnected the
tool from the air line and removed all remaining fasteners from the tool.
ALWAYS USE THE PROPER FITTING FOR THE TOOL
Only MALE pneumatic type air connectors should be fitted to the tool, so that
high-pressure air in the tool is vented to the atmosphere as soon as the air
line is dis-connected.
NEVER install FEMALE quick disconnect couplings on the tool. Female couplings
will trap high-pressure air in the tool when the air line is disconnected,
leaving the tool charged and able to drive at least one fastener.
DO NOT EXCEED THE MAXIMUM RECOMMENDED AIR PRESSURE
Operate the tool only at the recommended air pressure. Do not exceed the
maximum air pressure marked on the tool. Be sure the air pressure gauge is
operating properly and check it at least twice a day.
Never use any bottled air or gases such as oxygen to operate the tool since
they could cause the tool to explode. Do not operate in explosive atmospheres.
INSPECT TOOL FOR PROPER OPERATION
USE ONLY PASLODE RECOMMENDED PARTS AND FASTENERS
Use only parts and fasteners specifically designed and recommended by Paslode
for use in the tool and for work to be done. Using unauthorized parts and
fasteners or modifying the tool in any way creates dangerous situations.
Replace all missing warning labels. Refer to tool schematic for correct
placement and part number.
TOOL OPERATION
Fasteners
The Paslode T250S-F16P Finish Nailer drives Paslode® 16 gauge fasteners
designed to be used with the tool. The use of fasteners that do not meet
Paslode standards could cause tool damage and will void all warranty claims.
Loading Fasteners
STEP 1: Align the heads of the Paslode 16 ga.Finish nails to the brad
channel in the rear of the magazine and insert one or two strips. Push the
nails strips forward.
STEP 2: Next, pull the follower toward the rear of the magazine until the
follower passes the last strip of fasteners.Release the follower and let the
follower push the nails forward into the nose of the tool.
When the follower reaches the reload area, marked on the side of the magazine,
you may insert a new strip of nails. When the follower arrow reaches the
lockout area the tool automatically locks the tool to prevent the tool from
operating. To unlock the tool, simply reload another strip of nails.
Depth of Drive Adjustment
Disconnect the air supply.
The depth of drive adjustment is done by turning the adjustment wheel located
below the trigger.
Clearing a Jam
An occasional problem you may encounter is a jammed fastener. Because of the
unique design of the Paslode Finish Nailer, clearing a jammed fastener is
easy:
- Disconnect the air supply.
- Pull the latch, releasing front guide. Pivot front guide forward.
- Clear jam, and push driver blade back up to its normal position.
- Close front guide and latch it. Check that work contacting element moves freely.
Lockout Feature
The purpose of this feature is to prevent needless blank cycling, which could mar woods and damage tool components. T en (10) nails will be left in the magazine when the follower reaches the lockout area. When changing fastener length or loading at the beginning of the work day, you should inspect the magazine and nose for any fasteners left in the tool. These nails will not be visible unless you open the nose of the tool.
Trigger Methods:
The Paslode T250S-F16P Finish Nailer has a triggering system than can be
switched from sequential to contact trip. To switch the trigger, press in the
round button on the left side of the trigger and rotate the right side of the
button to the desired triggering method. The TTT indicates contact trip and
the T indicates sequential operation.
Successive (Bounce) Driving
Grasp the handle firmly.
Squeeze the trigger and move the tool along the work-piece with a bouncing
motion, depressing the work con-tacting element at the points where you want
to drive a fastener.
Keep the trigger depressed and continue to bounce the work contacing element
against the workpiece, position-ing the tool above as carefully as possible.
When the desired number of fasteners have been driven, release the tool
trigger to avoid unintentional fastener discharge.
Sequential Operation
The sequential setting T prevents succesive or “bounce” driving.
Depress the work contacting element and hold it against the work surface
before pulling the trigger.
After each fastener is driven, completely release the trigger and lift the
tool from the work surface.
Unload Nails:
To unload nails, simply pull the follower to the rear of the magazine and press the center lock button on the follower. The lock will move the follower out of the way and allow nails to slide past the follower and out of the rear of the magazine. To release the lock simply pull the follower back and the lock button will release and allow the follower to move forward.
Reversible Belt Hook:
The belt hook can be changed from the left hand side of the tool to the right
hand side. T o change the position, squeeze the base of the belt hook and
remove it from the tool and tool and position it on the desired side.
MAINTENANCE
Paslode® tools are built for ease of maintenance. A few simple details will assure trouble-free operation and long tool life. Anyone who uses or maintains the tool must read the safety and maintenance instructions. Study the sche- matic drawing before starting any repairs on the tool.
Air-operated tools must be inspected periodically, and worn or broken parts must be replaced to keep the tool operating safely and efficiently. Also the items on the maintenance chart must be checked often.
Cold Weather Care
When temperatures are below freezing, tools should be kept warm by any
convenient, safe method. If this is not possible, the following procedure
should be used to warm up the tools.
- Reduce the regulated air pressure to 30 psi.
- Remove all fasteners from the tool.
- Collect an air line and blank fire the tool. The reduced air pressure will be enough to free-fire the tool. Slow speed operation tends to warm up the moving parts. Slowing up the piston helps the bumper and the O-rings to become springy.
- Once the tool is warmed up, readjust the regulator to the proper working pressure and reload the tool.
- Open the drain on the air compressor tank to drain any moisture at least daily in extremely cold or humid weather. A few ounces of anti-freeze in the tank will keep the air free of frost.
Testing the Tool After Servicing
After replacing any part or parts, it is important to check the tool for
proper operation. This ensures that the tool was put together correctly, is
safe to use, and will perform the job properly.
- Ensure that all hardware is tight.
- Ensure that the work contacting element is installed correctly in relation to the trigger, and that both parts move freely.
- Ensure that the magazine is properly attached.
- Ensure that the required safety information on the tool is legible.
- Use only Paslode approved fasteners in the tool, and ensure that they are correct for the application.
- Ensure that a male air fitting is securely connected to the tool.
- Test the tool by driving fasteners into a workpiece iden-tical to the tool’s application.
- Check the tool for air leaks during testing and for the proper sequence of operation.
- Ensure that all fasteners are driven to the same depth and that the crown of the fastener is flush with the work-piece.
Most minor problems can be resolved quickly and easily using the maintenance table that follows. If problems per-sist, contact your Paslode dealer for assistance.
ACTION | WHY | HOW |
---|
Drain air line filter (daily).
| ****
Prevent accumulation of moisture and dirt.
| ****
Open manual petcock (most air supply systems have such a valve).
Clean filter element, then blow air through filter in direction opposite to normal flow.
| ****
Prevent clogging of filter with dirt.
| ****
Wash with soap and water or follow manufacturers instruc- tions.
Check that all screws on tool are tight.
| ****
Prevent air leakage and pro- mote efficient operation.
| ****
Check screws daily.
Keep work contacting element working properly.
| ****
Promote operator safety and efficient tool operation.
| ****
Blow clean daily.
Keep magazine and feeder mechanism clean.| Prevent jamming of fasteners.| Blow
clean daily.
Use only Paslode replacement parts.| Keep tool operating efficiently and
maintain Paslode tool warranty.| Order any replacement parts needed from
Paslode Dealer.
OPERATOR TROUBLESHOOTING
PROBLEM | CORRECTIVE ACTION |
---|
Fasteners will not drive completely into wood.
| ****
Adjust the depth of drive adjustment (retract length).
Increase air pressure (do not exceed 120 psi).
Fasteners penetrate properly during normal operation, but won’t drive fully at faster speeds.
| ****
Increase air flow to tool — use larger air lines (3/8 inch ID minimum).
Fasteners drive too deeply into wood.
| ****
Adjust the depth of drive adjustment (extend length). Reduce air pressure.
Fastener jams in nose of tool.
| ****
Open front guide latch, release jammed fastener, and close latch securely.
Tool skips during operation – no fasteners are driven from time to time.
| ****
Check magazine for proper fasteners. Magazine follower should slide freely. Clean as needed to remove debris.
Make sure correct fasteners are being used. Use fasteners that meet Paslode® specifications only.
Increase air flow to tool — use larger air lines (3/8 ID minimum).
Adjust work contacting element where available.
Tool operates, but no fasteners are driven.
| Check magazine for proper fasteners. Fasteners should slide freely with no follower pressure.
Open front guide latch and check for jams or debris in the nose area. Clear as necessary
Increase air pressure (do not exceed 120psi).
Air leaks at cap when tool is connected to air.
| ****
Tighten cap screws.
PARTS LEGEND
1
2
- 3
4
5
6
7
8
- 9
*10
- 11
*12
*13
*14
*15
*16
*17 18
*19
*20
- 21
*22
*23 24
*25 26
27
28
29
30
31
32
33
34
35
36
| 515501
515502
515503
515504
515505
515506
515507
515508
515509
515510
515511
515512
515513
515514
515515
515516
515517
515518
515519
515520
515521
515522
515523
515524
515525
515526
615920
515528
515529
515530
515531
403713
515533
515534
515535
515536
| 7
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
| Hex. Soc. Hd. Bolt Cap
O-Ring
Top Cap Ring Hex. Soc. Hd. Bolt Spacer
Piston Stopper Spring
Head Valve Assembly O-Ring
O-Ring Seal
Top Cap Seal Collar
Driver Blade Assembly Wear-Ring
O-Ring Cylinder O-Ring
Cylinder-Ring O-Ring
O-Ring Bumper Housing
End Cap Seal End Cap
Air Plug Spring Pin Bumper Seal
Depth of Drive A WCE Connector E-Ring
Latch Spring Assembly Latch
Spring Pin Door
| 37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
** 68
69
70
71
| 515537
515538
515539
515540
515541
617456
515543
515544
515545
515546
515547
515548
515549
515550
617780
515552
515553
515554
515555
515556
515557
515558
515559
515560
515561
515562
515563
515564
515565
515566
515567
515568
515569
515570
515571
| 1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
1
2
1
1
1
1
| Spring Pin WCE
Hex. Soc.Hd. Bolt Set Plate
Nose Spring
Lock-out Lever Spring Pin Spring Pin Upper Plate Nail Guide
Hex. Soc.Hd. Bolt Belt Hook
Trigger Valve Assembly Spring
Selectable Trigger Magazine (Right) Pusher
Spring Spring Pin
Pusher Seat Assembly Roll Spring
Magazine (Left) Lock Nut
Flat self-tapping Bolt Pusher Upper seat Push Button
Spring
UM. HD. Bolt Lower Plate Logo Label Warning Label Model Label
Magazine Assembly Lock Label
---|---|---|---|---|---|---|---
- Denotes Normal Wear Items.
- Make sure Warning Label (515568) is properly affixed.
Replace if necessary.
SAFETY INSTRUCTIONS
WEAR EYE AND HEARING PROTECTION
Always wear hearing protection and eye protection devices, including side shields when operating or working in the vicinity of a tool.
DO NOT EXCEED MAXIMUM
RECOMMENDED AIR PRESSURE
Operate the tool using only the recommended air pressure. Do not exceed the
maximum air pressure marked on the tool. Be sure the air pressure gauge is
operating properly and check it at least twice a day.
Never use any bottled air or gases such as oxygen to operate the tool since
they could cause the tool to explode.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>