STELPRO ACWS1000 Series Architectural Cabinet User Guide
- June 5, 2024
- StelPro
Table of Contents
USER’S GUIDE
ACWS1000 SERIES
ARCHITECTURAL CABINET
THE REPLACEMENT COMPONENT LIST INCLUDED
This unit complies with CSA and UL TECHNICAL DRAWING standards
IMPORTANT INSTRUCTIONS
WARNING
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be
considered null and void and the manufacturer deems no further responsibility
for this product.
This product must be installed by a qualified person and connected by a
certified electrician, according to the electrical and building codes
effective in your region.
The following instructions must be adhered to in order to avoid personal
injuries or property damages, serious injuries, and potentially fatal electric
shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in
accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the
unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing,
and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to
the product catalog or a representative). Use this heater only as described in
this manual. Any other use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons. Do not use outdoors.
RECOMMENDED HEATING CAPACITY:
1.25 W/cubic foot (0.03 m³).
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist (industrial
and commercial buildings) who will be able to calculate these heat losses and
optimize the required capacity or consult the “Online heating calculation”
section of the Stelpro Design Web site (residential buildings).
Do not install the unit where objects or pieces of furniture could be heat
damaged.
If the unit capacity is insufficient for the size of the room, it will be in
operation continuously and may become defective earlier and turn yellow.
Respect distances and positions indicated in the installation section.
If the installer or the user modifies the unit, they will be held responsible
for any damage resulting from this modification, and the CSA certification
could be void.
This unit must not come into contact with a water source and must be protected
from splashes (e.g. a wet mop). Do not use it if any part has been immersed.
Moreover, do not turn it on or off when standing in water or if your hands are
wet.
When cutting or drilling into a wall or ceiling, do not damage electrical
wiring and other hidden utilities.
Do not install this product on walls made of synthetic material such as, but
not limited to, carpet and wallpaper.
When starting up the unit for the first time or after a long period, it is
normal that it produces some temporary odors and whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal
operation. Therefore, be careful and responsible when using it. To avoid
burns, do not let bare skin touch hot surfaces. Let the unit cool down for a
few minutes before handling (it will stay warm for some time after shut-down).
Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
CAUTION – High temperature; risk of fire. Keep electrical cords, drapery,
furnishings, and other combustibles at least 3 feet (0.9 m) from the front of
the heater and away from the side and rear.
Never block air vents (with objects or other items). You risk damaging the
heater and the obstruction could lead to electric shock or overheating, which
could result in a fire.
Do not install it on a wall behind a door.
Do not insert or allow foreign objects to enter any air vent as this may cause
electric shocks, fires, or damage to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to
be used or stored in wet areas or areas containing flammable liquids,
combustible materials, or corrosive, abrasive, chemical, explosive, and
flammable substances such as but not limited to, gasoline, paint, chlorine,
sawdust, and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to
evaluate if the unit must be cleaned based on the amount of dirt accumulated
on and inside air vents. Accumulated dirt can lead to a component malfunction
or give a yellowish color to the unit. Failure to install and maintain the
unit in accordance with these instructions poses a fire hazard.
The thermal protection activation indicates that the unit has been subjected
to abnormal operating conditions. If the thermal protection remains activated
or activates and deactivates repeatedly, it is recommended that a qualified
electrician or a certified repair center examine the unit in order to make
sure it is not damaged. (Refer to the limited warranty)
Before unplugging the unit, all controls must be in the “OFF” position and the
current from the main breaker panel should be cut. (The general switch may be
used also if included.)
If the unit is damaged or defective, discontinue use, cut off the power supply
at the circuit breaker, and contact a certified electrician or certified
repair center. (Refer to the limited warranty)
SAVE THESE INSTRUCTIONS
Note: When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.
SPECIFICATIONS, TECHNICAL DRAWINGS, INSTALLATION & OPERATION
SPECIFICATIONS
1000 W DENSITY
PER LINEAR FOOT| 800 W DENSITY
PER LINEAR FOOT| 600 W DENSITY
PER LINEAR FOOT| VOLTS| MM| IN.| KG| LB
---|---|---|---|---|---|---|---
—| 2000 W| —| 1600 W| ACWS1000612X| 1200 W| X| 600| 23 5/8| 15.8| 35
ACWS1000930X| 3000 W| ACWS1000924X| 2400 W| ACWS1000918X| 1800 W| X| 900| 35
7/16| 24.1| 53
ACWS10001240X| 4000 W| ACWS10001232X| 3200 W| ACWS100012224X| 2400 W| X| 1200|
47 1/4| 31.2| 69
ACWS10001550X| 5000 W| ACWS10001540X| 4000 W| ACWS10001530X| 3000 W| X| 1500|
59 1/16| 38.1| 84
ACWS10001860X| 6000 W| ACWS10001848X| 4800 W| ACWS10001836X| 3600 W| X| 1800|
70 7/8| 44.4| 98
Add W for white or SW for soft white.
x = 2 (240 V) 3 (347 V) 5 (480 V) 6 (600 V) 7 (277 V) 8 (208 V)
For a complete model list, consult our online product catalog at
www.stelpro.com
TECHNICAL DRAWINGS
INSTALLATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to the
installation and wiring connections. This product must be connected by a
certified electrician, according to the electrical and building codes
effective in your region. Consult the wiring plan found on the unit.
To reduce the risk of fire, do not store or use gasoline or other flammable
vapors and liquids in the vicinity of the heater. Do not mount in contact with
combustible material. Do not mount in close proximity to another unit.
Keep the front and upper sides of the unit at least 3 feet (91 cm) from any
adjacent surfaces. Moreover, make sure objects or pieces of furniture such as,
but not limited to, blankets, towels, beds, laundry baskets, clothing, papers,
electric wires, and other flammable items, do not come into contact with the
unit and keep them at least 3 feet (91 cm) from the unit. Failure to comply
with this warning could lead to a fire. Some materials are more heat-sensitive
than others, so make sure those near the unit can withstand heat.
- Do not install a cabinet below an electrical outlet.
- To install accessories (e.g.: thermostat), consult the related guides.
OPERATION AND TROUBLESHOOTING
ELECTRICAL DIAGRAM
OPERATION
Warning: the heater must be properly installed before it is used.
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|---|
The unit does not work | • Defective thermostat or wrong thermostat setting |
• Open circuit breaker or fuse
• Thermal protection activated
• Faulty connections
The unit runs continuously| • Defective thermostat or wrong thermostat
settingà
• Heat losses higher than the unit capacity
The enclosure is extremely hot| • Defective thermal protection
• Blocked air vents
The desired room temperature cannot be reached| • One or more defective
elements
• Defective thermostat or wrong thermostat setting
• Voltage lower than written on the nameplate
• Heat losses higher than the unit capacity
Overheating| • Defective thermostat or wrong thermostat setting
The unit cycles under the control of the thermal protection
(overheat indicator)| • Blocked air vents
The breaker trips when the heater is turned on| • Faulty connections
• Voltage higher than written on the nameplate
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the “Limited Warranty” section to obtain the phone numbers).
REPLACEMENT COMPONENT LIST
REPLACEMENT COMPONENT LIST
REF. # | DESCRIPTION |
---|---|
1 | ELEMENT |
2 | ALUMINUM GRILL |
3 | LINEAR THERMAL. PROTECTION (AUTO.) |
4 | THERMOSTAT |
MAINTENANCE
MAINTENANCE
CAUTION – High temperature; risk of fire. Keep electrical cords, drapery,
furnishings, and other combustibles at least 3 feet (0.9 m) from the front of
the heater and away from the side and rear. All other repairs and maintenance
other than those described in this guide should be performed by qualified
service personnel. In order for the warranty to be valid, the unit must be
cleaned regularly.
Cut off power supply at circuit breaker/fuse and wait for the unit to cool
down before cleaning.
WARNING: if the unit is equipped with a circuit breaker, the power supply
at the main breaker must be turned off before removing the cover of the
junction box or opening or closing the unit’s circuit breaker.
Use a soft rag for dusting. When cleaning, use only a damp rag and nonabrasive
dish soap.
If you use a cleaning product, always wipe the product off properly to avoid
the discoloration of the unit. Do not use abrasive or chemical cleaners
because they may damage the finishing. If the unit is used in a very dusty
location, use a vacuum brush to remove dust and other foreign objects from the
grilles. Note that cigarette smoke could yellow the discharge grille and that
the best way to prevent it is to clean the unit on a regular basis.
Do not use cleaning products identified with these symbols:
N.B. Note that there is an electrical current linked to the unit even if the thermostat is set off. This means that there is a risk of electric shock as long as the unit is energized.
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and
applies to the following product made by Stelpro: model ACWS1000. Please read
this limited warranty carefully. Subject to the terms of this warranty,
Stelpro warrants its products and their components against defects in
workmanship and/or materials for the following periods from the date of
purchase: 3 years. This warranty applies only to the original purchaser; it is
non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) Stelpro’s customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves the
right to examine or to ask one of its representatives to examine the product
itself or any part of it before honoring the warranty. Stelpro reserves the
right to replace the entire unit, refund its purchase price, or repair a
defective part. Please note that repairs made within the warranty period must
be authorized in advance in writing by Stelpro and carried out by persons
authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at:
1-800-363-3414 (electricians and
distributors – French), 1-800-343-1022
(electricians and distributors – English), or
1-866-766-6020 (consumers).
The authorization number must be clearly written on the parcel or it will be
refused.
CONDITIONS, EXCLUSIONS, AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except of title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts, or
omissions relating thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities, or services, shutdowns, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental, and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro),
or use other than that for which the unit was designed; 3) a natural disaster
or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages, nor does it cover damages caused by the
negligence of the user or owner of the product. Moreover, it does not cover
the cost of disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of Stelpro. Any parts replaced
or repaired within the warranty period with the written authorization of
Stelpro will be warranted for the remainder of the original warranty period.
This warranty will be considered null and void and Stelpro will have the right
to refuse any claims if products have been altered without the written
authorization of Stelpro and if the nameplate numbers have been removed or
modified. This warranty does not cover scratches, dents, corrosion, or
discoloration caused by excessive heat, chemical cleaning products, and
abrasive agents. It does not cover any damage that occurred during the
shipping.
Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages and some of them do not allow limitations
on how long an implied warranty lasts, so these exclusions or limitations may
not apply to you. This warranty gives you specific legal rights and you may
have other rights which vary from state to state or from province to province.
For further information or to consult this guide online, please visit our
website at www.stelpro.com
INSACWS10000622
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>