Stiebel Eltron SHU 5 SLi comfort SMALL WATER HEATER Installation Guide
- June 5, 2024
- STIEBEL ELTRON
Table of Contents
- 1. General information
- 2. Safety
- 3. Appliance description
- 4. Cleaning, care and maintenance
- 5. Troubleshooting
- 6. Safety
- 7. Appliance description
- 8. Preparation
- 9. Installation
- 10. Commissioning
- 11. Settings
- 12. Shutdown
- 13. Troubleshooting
- 14. Maintenance
- 15. Specification
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Stiebel Eltron SHU 5 SLi comfort SMALL WATER HEATER Installation Guide
GUARANTEE
ENVIRONMENT AND RECYCLING
INSTALLATION TEMPLATE SHU 5 SLI | SHU 5 SL GB (INSIDE THESE INSTRUCTIONS)
SPECIAL INFORMATION
– The appliance may be used by children aged 8 and older and persons with
reduced physical, sensory or mental capabilities or a lack of experience and
know-how, provided that they are supervised or they have been instructed on
how to use the appliance safely and have understood the resulting risks.
Children must never play with the appliance. Children must never clean the
appliance or perform user maintenance unless they are supervised.
– In the case of permanent connection to the power supply via a junction box,
ensure that the appliance can be isolated from the mains by an isolator that
disconnects all poles with at least 3 mm contact separation.
– The power cable may only be replaced (for example if damaged) by a qualified
contractor authorised by the manufacturer, using an original spare part.
– Secure the appliance as described in chapter “Installation / Installation”.
– Observe the maximum permissible pressure (see chapter “Installation /
Specification / Data table”).
– The appliance is pressurised. During the heat-up process, expansion water
will drip from the safety valve.
– Regularly activate the safety valve to prevent it from becoming blocked,
e.g. by limescale deposits.
– Drain the appliance as described in chapter “Installation / Maintenance /
Draining the appliance”.
– Size the drain pipe so that water can drain off unimpeded when the safety
valve is fully opened.
– Fit the drain pipe of the safety valve with a constant downward slope and in
a room free from the risk of frost.
– The safety valve drain must remain open to the atmosphere.
1. General information
The chapters “Special Information” and “Operation” are intended for users and
qualified contractors. The chapter “Installation” is intended for qualified
contractors.
Note Read these instructions carefully before using the appliance and
retain them for future reference. Pass on the instructions to a new user if
required.
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
▶ Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
1.1.3 Keywords
1.2 Other symbols in this documentation
▶ This symbol indicates that you have to do something. The action you need to take is described step by step.
1.3 Units of measurement
Note
All measurements are given in mm unless stated otherwise.
2. Safety
2.1 Intended use
This sealed unvented (pressurised) appliance is intended for heating domestic hot water. You can use the appliance to supply one or several draw-off points. This appliance is intended for domestic use. It can be used safely by untrained persons.
The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance.
2.2 Safety instructions
Where children or persons with limited physical, sensory or mental abilities are allowed to use this appliance, we recommend a permanent temperature limit. A qualified contractor can set this limit.
Material losses
If the drain pipe of the safety valve is sealed, the expansion water may cause
water damage.
▶ Never close the drain pipe.
Material losses
The user should protect the appliance and its tap against frost.
2.3 Test symbols
See type plate on the appliance.
3. Appliance description
The sealed unvented (pressurised) appliance constantly maintains the water content at the pre-selected temperature. The appliance switches on automatically as soon as its temperature falls below the set value. Subject to season, varying cold water temperatures can result in different maximum mixed water and outlet volumes.
Note
A qualified contractor can set a temperature limit on the appliance (see
“Installation / Settings / Setting the temperature limit”).
Note
The appliance is under mains water pressure. The water volume increases as the
cylinder is being heated up. During this process, expansion water drips out
through the safety valve. This is a necessary and normal process.
3.1 Operation
You can set any required DHW outlet temperature at the temperature selector. The heat-up indicator illuminates during the heat-up process.
Depending on the system, the actual temperatures may vary from the set value.
°C = Cold. On this setting, the appliance is protected from frost. The tap and
the water line are not protected.
Eco = Recommended energy saving setting (approx. 60 °C), minor scaling
82 = Highest selectable temperature
4. Cleaning, care and maintenance
▶ Never use abrasive or corrosive cleaning agents. A damp cloth is sufficient
for cleaning the appliance.
▶ Check the taps regularly. Limescale deposits at the tap outlets can be
removed using commercially available descaling agents.
▶ Have the function of the safety assembly checked regularly by a qualified
contractor.
Almost every type of water will deposit limescale at high temperatures. This settles inside the appliance and affects both the performance and service life. The heating elements should therefore be descaled if necessary. A qualified contractor who is aware of the local water quality will tell you when the next descaling is due.
5. Troubleshooting
6. Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations and instructions.
6.3 Information on the safety assembly
If using a plastic stench trap (e.g. DN 40 for the sink), there is no need for the SVMT immersion pipe. Connect the overflow funnel, e.g. using the washing machine connection.
7. Appliance description
The sealed unvented (pressurised) appliance is only suitable for undersink installation. The appliance is intended for heating cold water and for supplying one or several draw-off points. The appliance may only be installed with pressure taps in conjunction with the SVMT safety assembly (see chapter “Installation / Appliance description / Required accessories”).
7.1 Standard delivery
Delivered with the appliance are the following:
– Wall mounting bracket
SHU 10 SLi
– Installation template
7.2 Required accessories
The following accessories are available for sealed unvented operation:
– SVMT safety assembly for undersink installation
– Water distribution tees
8. Preparation
Water installation
A safety assembly is required.
Taps/valves
Only install pressure taps in conjunction with the SVMT safety assembly.
8.1 Installation site
Always install the appliance vertically and near the draw-off point.
9. Installation
Material losses
When using plastic pipework, observe the extreme operating and fault
conditions that can occur on the appliance (see chapter “Installation /
Specification / Extreme operating and fault conditions”).
▶ To provide a supply to two washbasins, use the “water distribution tees”
(see chapter “Installation / Appliance description / Required accessories”).
▶ Run the connections to the second tap on site, e.g. in 10 mm copper pipe.
9.1 Installing the safety assembly
▶ Fit the safety assembly in the cold water supply line of the appliance.
▶ Observe the information on the safety assembly (see chapter “Installation /
Safety / Information on the safety assembly”).
▶ Observe the information in the safety assembly installation instructions.
9.2 Appliance installation
9.3 Water connection
Match up the colour coding on the water connections of the tap and the
appliance: – R.h. side blue = “Cold water inlet” – L.h. side red = “DHW
outlet”
▶ Secure the tap connections to the appliance.
Note
Ensure that the water connections are not kinked during installation. Prevent
any tensioning during installation.
9.4 Power supply
The following electrical connections are permissible:
10. Commissioning
WARNING ELECTROCUTION Commissioning may only be carried out by a qualified contractor in accordance with safety regulations.
10.1 Initial start-up
▶ Either open the DHW valve of the tap or set the mono lever mixer tap to
“hot” until the water that flows out is free of air bubbles.
▶ Check the safety assembly. When purging, ensure that a full jet of water
flows out.
▶ Insert the plug into the standard socket or set the fuse/MCB in the fuse
box.
▶ Select a temperature.
▶ Check the entire hydraulic installation for tightness.
10.1.1 Appliance handover
▶ Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
▶ Make the user aware of potential dangers, especially the risk
of scalding.
▶ Hand over these instructions and, if applicable, the instructions for any
accessories.
10.2 Recommissioning
See chapter “Installation / Commissioning / Initial start-up”.
11. Settings
11.1 Setting the temperature limit
Placing the limiting ring behind the temperature selector allows you to limit the setting range of the temperature selector to a specific maximum temperature.
▶ Turn the temperature selector to zero (fully anti-clockwise to “°C”).
▶ Pull off the temperature selector and the limiting ring.
▶ Push the limiting ring with the required maximum setting onto the controller
shaft.
▶ Mount the temperature selector set to zero (°C).
12. Shutdown
▶ Isolate the appliance from the power supply by removing the plug or by
tripping the MCB in the fuse box.
▶ Drain the appliance (see chapter “Installation / Maintenance / Draining the
appliance”).
13. Troubleshooting
13.1 Activating the high limit safety cut-out
14. Maintenance
WARNING Electrocution Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
▶Dismantle the appliance for maintenance work.
14.1 Draining the appliance
WARNING Burns Hot water may escape during draining.
▶ Drain the appliance via its connectors.
14.2 Opening the appliance
14.3 Descaling the appliance
▶ Remove the flanged immersion heater.
▶ Carefully tap the heating element to remove coarse limescale
deposits.
▶ Immerse the heating element up to the flange plate in descaling agent.
14.4 Checking the earth conductor
▶ Check the earth conductor (in Germany DGUV3 for example) across a water connector and the earth conductor contact of the power cable.
14.5 Replacing the power cable
The power cable must only be replaced by a qualified contractor with an original spare part. Alternatively, the H05VV-F3x1.0 cable may be used.
![Stiebel Eltron SHU 5 SLi comfort SMALL WATER HEATER Installation Guide
- Replacing the power cable](https://manuals.plus/wp-content/uploads/2022/07
/Stiebel-Eltron-SHU-5-SLi-comfort-SMALL-WATER-HEATER-Installation-Guide-
Replacing-the-power-cable.jpg)
14.6 Positioning the temperature sensor in its protective pipe
15. Specification
15.1 Dimensions and connections
SHU 5 SLi | SHU 10 SLi
SHU 5 SL GB
15.2 Wiring diagram
1/N/PE ~ 220 – 240 V
15.3 Heat-up diagram
The heat-up period depends on the degree of scaling and residual heat. For the heat-up time for a cold water supply at 10 °C and a maximum temperature setting, see the diagram.
15.4 Country-specific approvals and certifications
The test symbols can be seen on the type plate.
15.5 Extreme operating and fault conditions
In the case of faults, a peak temperature of up to 105 °C may briefly occur in the system.
15.6 Details on energy consumption
15.7 Data table
Guarantee
The guarantee conditions of our German companies do not apply to appliances
acquired outside of Germany. In countries where our subsidiaries sell our
products a guarantee can only be issued by those subsidiaries. Such guarantee
is only granted if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in countries where
we have no subsidiary to sell our products. This will not affect warranties
issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the
various materials in accordance with national regulations.
Deutschland
STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße 33 | 37603 Holzminden
Tel. 05531 702-0 | Fax 05531 702-480
info@stiebel-eltron.de
www.stiebel-eltron.de
Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-
eltron.de
Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-
eltron.de
Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile
@stiebel-eltron.de
Subject to errors and technical changes!
References
- ELTRON • IT-oplossingen op maat. Gespecialiseerd in facturatiesoftware
- This domain has been registered for a customer by nicsell
- ELTRON.CO.UK
- Sachverständigenbüro ELTRON - Startseite
- ELTRON
- eltron.ru
- Tankless Water Heater | Renewable Energy | Stiebel Eltron USA
- STIEBEL ELTRON | Technik zum Wohlfühlen
- Warmtepompen - warmwater - verwarming - ventilatie | STIEBEL ELTRON
- Home - Stiebel Eltron UK
- STIEBEL ELTRON International
- STIEBEL ELTRON | Tepelná čerpadla, rekuperace, ohřev vody
- STIEBEL ELTRON | Technik zum Wohlfühlen
- Stiebel Eltron Suomessa | Thermia Finland Oy | Thermia
- STIEBEL ELTRON - Fabricant Allemand de pompes à chaleur
- STIEBEL ELTRON - Főoldal
- STIEBEL ELTRON
- STIEBEL ELTRON | Официальный сайт | Интернет-магазин
- STIEBEL ELTRON | Ohrev vody, vykurovanie, vetranie, chladenie
- Instantaneous Hot Water Systems, Electric Water Heaters - STIEBEL ELTRON
- 热泵系统-新风系统-采暖系统-热水器-德国百年暖通品牌-世创电能(原斯宝亚创)
- stiebeleltronasia.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>