ENLITE EN-BH15, EN-BH25 Orbital Round LED Instruction Manual

June 3, 2024
ENLITE

ENLITE logo EN-BH15, EN-BH25 Orbital Round LED
Instruction Manual

EN-BH15, EN-BH25 Orbital Round LED

INSTALLATION METHOD A. MOUNTING BRACKET FIXING

ENLITE EN-BH15, EN-BH25 Orbital Round LED - Figure 1

INSTALLATION METHOD B. INTERNAL SCREW FIXING

ENLITE EN-BH15, EN-BH25 Orbital Round LED - Figure 2

PRODUCT Ø+H L
EN-BH15 Ø 300X95mm 5± 229mm
EN-BH25 Ø 360X105mm 5± 279mm

ENLITE EN-BH15, EN-BH25 Orbital Round LED - Figure 3

MICROWAVE SENSOR/CORRIDOR FUNCTION

DETECTION AREA
The detection area can be reduced by selecting the combination on the DIP switches to fit precisely each application.

| 1| 2| 3|
---|---|---|---|---
ON| ON| ON| 100%
–| ON| ON| 75%
ON| –| ON| 50%
–| –| ON| 25%
–| –| –| 10%

HOLD TIME
Refers to the time period the lamp remains at 100% illumination after no motion is detected.

| 4| 5| 6|
---|---|---|---|---
ON| ON| ON| 100%
–| ON| ON| 75%
ON| –| ON| 50%
–| –| ON| 25%
–| –| –| 10%

DAYLIGHT SENSOR
The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold.
When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of the ambient light level.
50lux: twilight operation, 10lux, 2lux: darkness operation only.

| 7| 8| 9|
---|---|---|---|---
ON| ON| ON| 100%
–| ON| ON| 75%
ON| –| ON| 50%
–| –| ON| 25%
–| –| –| 10%

IMPORTANT INSTALLATION INFORMATION

  • Installation should be carried out in accordance with the latest edition of the National wiring regulations (For Australia please check the latest edition of the Wiring Rules -AS/NZS 3000:2007). If in doubt please consult a qualified electrician.
  • All luminaires run hot. It is the installer’s responsibility to consider fire risk and take appropriate precautions.
  • Input voltage – 220-240V 50Hz AC.
  • IP66 Rated is suitable to resist High-pressure jets of water.
  • These luminaires are not dimmable.
  • LED luminaire, there are no user-serviceable parts in this luminaire.
  • Class 2 luminaires MUST NOT be connected to an earth terminal.
  • These luminaires are for indoor and outdoor use.
  • These luminaires can be installed on the surface of combustible materials.

Emergency Versions:

  • LED charge indicator: GREEN – Charging

OPERATION

  • When charged, the Battery/Inverter unit will provide power to the fitting during an interruption in the power supply.
  • After installation, the luminaire should be routinely tested by qualified and competent personnel using the schedule provided on the back of this installation guide.

BATTERIES AND DISPOSAL

  • Replacement of complete luminaire or battery pack as appropriate is required when the battery or LEDs no longer meet their rated duration of the operation.

Environmental Protection (W.E.E.E.) – Enlite’s WEEE Reg.No. WEE/BG0130YX (UK Only)

Waste Electrical & Electronic Equipment Regulations (WEEE) require that any of our products showing this marking (left) must not be disposed of with other household or commercial waste. Enlite does not levy any WEEE disposal charges to its customers for affected WEEE-related products.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre, or retailer for recycling advice. If, when you purchased any Enlite product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his take-back of the product for the correct disposal.
GUARANTEE
This product is guaranteed for a period of 3 years from the date of purchase. The guarantee is invalid in the case of improper use, installation, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National wiring regulations. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Enlite does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Enlite reserves the right to alter specifications without prior notice.

Routine Test Record

Luminaire Cat No.| Luminaire Location| (Attach floor plan to indicate the location of battery powered emergency lights).
---|---|---
Installation Engineer| T.| Installation Date
Commissioning Engineer| Tel.| Commissioning Date
MONTH| TEST| 1 Year| 2° Year| 3(” Year| 4 Year| 5 Year
sign| date| sign| date| sign| sign| sign| date| sign| date
0 ‘| 3 hour| | | | | | | | | |
1| Functional| | | | | | | | | |
2| Functional| | | | | | | | | |
3| Functional| | | | | | | | | |
4| Functional| | | | | | | | | |
5| Functional| | | | | | | | | |
6| 1 hour| | | | | | | | | |
7| Functional| | | | | | | | | |
8| Functional| | | | | | | | | |
9| Functional| | | | | | | | | |
10| Functional| | | | | | | | | |
11| Functional| | | | | | | | | |
12| 3 hcur| | | | | | | | | |

* Month 0 is the Initial Installation & Commissioning test.
N F PA Standard No. 101-31-1.3.7 – “A functional test shall be conducted on every required emergency lighting system at 30-day intervals for a minimum of 30 seconds. An annual test shall be conducted for the I V2 hour duration. Equipment shall be fully operational for the duration of the test. Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction.”

References

Read User Manual Online (PDF format)