JennAir JJD3024HL INDOOR OUTDOOR ELECTRIC SMALL WARMING DRAWER Installation Guide

June 5, 2024
JENNAIR

JennAir JJD3024HL INDOOR OUTDOOR ELECTRIC SMALL WARMING DRAWER

JennAir-
JJD3024HL-INDOOR-OUTDOOR-ELECTRIC-SMALL-WARMING-DRAWER-
PRODUCT

IMPORTANT:

  • Save for local electrical inspector’s use.
  • Conserver ces instructions à l’usage de l’inspecteur des installations électriques local.

WARMING DRAWER SAFETY

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

  • This is the safety alert symbol.
  • This symbol alerts you to potential hazards that can kill or hurt you and others.
  • All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
  • These words mean

DANGER
You can be killed or seriously injured if you don’t immediately follow instructions.

WARNING
You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

  • Phillips screwdriver
  • Flat-blade screwdriver
  • Measuring tape
  • Level
  • Drill
  • 13/8″ (3.5 cm) hole saw

Parts Supplied

  • Two 19 x 3.5 mm screws

Check local codes. Check existing electrical supply. See “Electrical Requirements.” It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

NOTE:
The warming drawer can be paired with models JJW6024, JMC6224 and JJB6424. The bottom trim is fixed to the bottom of the warming drawer and cannot be removed. This trim matches the bottom trim of model JJW2424 only.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

  • Cutout dimensions that are shown must be used. Given dimensions provide minimum clearance with the warming drawer.
  • The recessed installation area must provide a complete enclosure around the recessed portion of the warming drawer.
  • A grounded electrical supply is required. See the “Electrical Requirements” section.
  • The electrical supply outlet should be located in the rear wall on the upper right-hand side of the cutout or in an adjacent cabinet. The outlet must be recessed. If the electrical outlet is located in an adjacent cabinet, a 13/8″ (3.5 cm) minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet.
  • The warming drawer support surface must be solid, level, and flush with the bottom of the cabinet cutout.
  • 215/8″ (55.0 cm) minimum cabinet depth.

For best performance results make sure the warming drawer is leveled before completing installation. There is no way to level the warming drawer after it has been installed. If the installation is not level, the door may slide open or not seal tightly, allowing heat to escape.

NOTE: If installing the warming drawer below another product, refer to that product’s literature for any installation requirements.

Product Dimensions

JennAir-JJD3024HL-INDOOR-OUTDOOR-ELECTRIC-SMALL-
WARMING-DRAWER-FIG-1

  • A. 215/8″ (55.0 cm) oven depth
  • B. 2113/16″ (55.4 cm) recessed width
  • C. 59/16″ (14.1 cm) recessed height
  • D. 237/16″ (59.5 cm) overall width
  • E. 49/16″ (11.7 cm) drawer front height

Clearance Dimensions

JennAir-JJD3024HL-INDOOR-OUTDOOR-ELECTRIC-SMALL-
WARMING-DRAWER-FIG-2

  • A. 2215/16″ (58.2 cm) cutout height for both oven and warming drawer
  • B. 31″ (78.7 cm) minimum/recommended height from floor
  • C. 215/8″ (55.0 cm) cutout width
  • D. 235/8″ (60.0 cm) minimum cabinet width

NOTES:

  • If installed with an oven, no separator between them.
  • the warming drawer can be installed under a single oven.
  • The warming drawer cannot be leveled after being installed.

For outdoor installation, follow the cutout dimensions for a single warming drawer. Install the outdoor warming drawer in a permanent fixture.

Flush Installation

Front ViewJennAir-JJD3024HL-INDOOR-OUTDOOR-ELECTRIC-SMALL-WARMING-DRAWER-
FIG-3

Side View

Top View

A Width of flush inset cutout (minimum) 2311/16″ (60.2 cm)
B Height of flush inset cutout (minimum) 233/4″ (60.3 cm)
C Bottom of cutout to floor (minimum) If installed under model JMC6224 5″

(12.7 cm) If installed under any other model 31″ (78.7 cm)
D| Width of opening (minimum)| 215/8″ (55.0 cm) for JJD3024HM
E| Depth of cutout (minimum)| 227/16″ (57.05 cm) for JJD3024HM

221/2″ (57.13 cm) for JJD3024HL

F| Depth to Side Cleat| 13/16″ (2.1 cm) for JJD3024HM and JJD3024HL
g| Recommended outlet location|

Flush Installation Requirements
A 229/16″ (57.3 cm) minimum cutout depth is required. These dimensions will result in a 1/8″ (3 mm) reveal on all sides of the warming drawer. The front face of the cleats and platforms will be visible and should be treated as a finished surface.

Electrical Requirements

WARNING

  • Electrical Shock Hazard
  • Plug into a grounded 3-prong outlet.
  • Do not remove the ground prong.
  • Do not use an adapter.
  • Do not use an extension cord.
  • Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT:
The warming drawer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575.

  • A 120 V, 60 Hz, AC only, 15 A fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this warming drawer be provided.
  • The model/serial/rating plate is located beneath the drawer, on the drawer. See the illustration below.

INSTALLATION INSTRUCTIONS

Install Warming Drawer

WARNING

Excessive Weight Hazard Use two or more people to move and install the warming drawer. Failure to do so can result in back or another injury.

  1. Turn off the power supply. Using 2 or more people, move the warming drawer close to its final location. Remove and discard shipping materials, tape, and film from the warming drawer. Remove and set aside racks and other parts from inside the warming drawer.
  2. Check that the warming drawer control knob is set to the Fan position.
  3. Support the warming drawer on a sturdy surface level with the cutout opening.

WARNING

  • Electrical Shock Hazard
  • Plug into a grounded 3-prong outlet.
  • Do not remove the ground prong.
  • Do not use an adapter.
  • Do not use an extension cord.
  • Failure to follow these instructions can result in death, fire, or electrical shock.
  • Plug the power supply cord into the grounded 3-prong outlet.
  • Slide the warming drawer over halfway into the cutout opening.
  • Open the warming drawer and slowly push against the front panel to slide the drawer completely into the cabinet until the flanges on the front panel meet the cabinet face.

Use the two 19 x 3.5 mm screws provided to secure the warming drawer frame to the cabinet.JennAir-JJD3024HL-INDOOR-OUTDOOR-ELECTRIC-SMALL-WARMING-DRAWER-
FIG-7

Complete Installation

  1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
  2. Check that you have all of your tools.
  3. Dispose of/recycle all packaging materials.
  4. For warming drawer use and cleaning, read the Use and Care Guide.
  5. Push in and turn the control knob to 160°F (71°C) and push the red button. The light should illuminate.

If the warming drawer(s) does not operate, check the following:

  • The household fuse is intact and tight, or the circuit breaker has not tripped.
  • The warming drawer is plugged into a grounded 3-prong outlet.

If you need Assistance or Service:
Please reference the “Troubleshooting” section of the Use and Care Guide.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>