dahua ARD822-W2 Wireless Panic Button User Manual
- June 5, 2024
- Dahua
Table of Contents
dahua ARD822-W2 Wireless Panic Button
Foreword
General
This manual introduces the installation, functions and operations of the Wireless Panic Button (hereinafter referred to as the “button”). Read carefully before using the device, and keep the manual safe for future reference.
Model
DHI-ARD822-W2 (868); DHI-ARD822-W2
Safety Instructions
The following signal words might appear in the manual.
Signal Words | Meaning |
---|---|
DANGER | Indicates a high potential hazard which, if not avoided, will |
result in death or serious injury.
WARNING| Indicates a medium or low potential hazard which, if not
avoided, could result in slight or moderate injury.
CAUTION| Indicates a potential risk which, if not avoided, could result
in property damage, data loss, reductions in performance, or unpredictable
results.
TIPS| Provides methods to help you solve a problem or save time.
NOTE| Provides additional information as a supplement to the text.
Revision History
Version | Revision Content | Release Time |
---|---|---|
V2.0.0 | Added battery replacing notes. | April 2022 |
V1.0.0 | First release. | March 2022 |
Privacy Protection Notice
As the device user or data controller, you might collect the personal data of
others such as their face, fingerprints, and license plate number. You need to
be in compliance with your local privacy protection laws and regulations to
protect the legitimate rights and interests of other people by implementing
measures which include but are not limited: Providing clear and visible
identification to inform people of the existence of the surveillance area and
provide required contact information.
About the Manual
- The manual is for reference only. Slight differences might be found between the manual and the product.
- We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
- The manual will be updated according to the latest laws and regulations of related jurisdictions. For detailed information, see the paper user’s manual, use our CD-ROM, scan the QR code or visit our official website.
- The manual is for reference only. Slight differences might be found between the electronic version and the paper version.
- All designs and software are subject to change without prior written notice.
- Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation.
- There might be errors in the print or deviations in the description of the functions, operations and technical data.
- If there is any doubt or dispute, we reserve the right of final explanation. Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened. All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
- Please visit our website, contact the supplier or customer service if any problems occur while using the device.
- If there is any uncertainty or controversy, we reserve the right of final explanation.
Important Safeguards and Warnings
This section introduces content covering the proper handling of the device, hazard protection, and protection of property damage. Read carefully before using the device, and comply with the guidelines when using it.
Operation Requirements
Make sure that the power supply of the device works properly before use. Do
not pull out the power cable of the device while it is powered on. Only use
the device within the rated power range. Transport, use and store the device
under allowed humidity and temperature conditions. Prevent liquids from
splashing or dripping on the device. Make sure that there are no objects
filled with liquid on top of the device to avoid liquids flowing into it. Do
not disassemble the device.
Installation Requirements
-
Connect the device to the adapter before power on.
-
Strictly abide by local electrical safety standards, and make sure that the voltage in the area is
steady and conforms to the power requirements of the device. -
Do not connect the device to more than one power supply.
-
Otherwise, the device might become damaged.
-
Observe all safety procedures and wear required protective equipment provided for your use while working at heights.
-
Do not expose the device to direct sunlight or heat sources.
-
Do not install the device in humid, dusty or smoky places.
-
Install the device in a well-ventilated place, and do not block the ventilator of the device.
-
Use the power adapter or case power supply provided by the device manufacturer. The power supply must conform to the requirements of ES1 in IEC 62368-1 standard and be no higher than PS2. Note that the power supply requirements are subject to the device label.
-
Connect class I electrical appliances to a power socket with protective earthing.
Introduction
Overview
Wireless panic button is a wireless button transmitter that sends a panic alarm signal to the hub of the alarm security system. By just the press of the button, alarm signals and events are sent to the monitoring company to ensure a prompt response, and to keep you up to date via the DMSS app. It is suitable for use with security in homes, banks and more. It is also easy to carry around.
Technical Specifications
This section contains technical specifications of the button. Please refer to
the ones that correspond with your model.
Table 1-1 Technical specifications
Type | Parameter | Description |
---|---|---|
Function | Indicator Light | 1 for multiple statuses (pairing, communication, |
and more)
Button| 2
Remote Update| Cloud update
Signal Strength Detection| Yes
Low Battery Detection| Yes
Battery Level Display| Displays battery level on app
Wireless| Carrier Frequency| DHI-ARD822-W2 (868): 868.0 MHz–868.6 MHz| DHI-
ARD822-W2: 433.1 MHz–434.6 MHz
Communication Distance| DHI-ARD822-W2 (868):
Up to 1,400 m (4,593.18 ft)
in an open space| DHI-ARD822-W2:
Up to 1,300 m (4,065.09 ft) in an open space
Power Consumption| Limit 14 mW
Communication Mechanism| Two-way
Encryption Mode| AES128
Frequency Hopping| Yes
General| Operating Temperature| –10 °C to +55 °C (+14 °F to +131 °F) (indoor)
Operating Humidity| 10%–90% (RH)
Battery Life| 5 years (if used twice a week)
Product Dimensions| 55 mm× 36 mm× 14.2 mm (2.17″ × 1.42″ × 0.56″) (L× W× H)
Packaging Dimensions| 95 mm× 59.5 mm× 30.5 mm (3.74″ × 2.34″ × 1.20″) (L× W×
H)
Installation| Wall mount; handheld
Net Weight| 18 g (0.04 lb)
Gross Weight| 48 g (0.11 lb)
Certifications| DHI-ARD822-W2 (868): CE| DHI-ARD822-W2: CE; FCC
Casing| PC + ABS
Protection| IP54
Technical| Operating Current| 28 mA
Test Mode| Yes
Checklist
Figure 2-1 Checklist
Table 2-1 Checklist
No.| Item Name| Quantity| No.| Item Name|
Quantity
---|---|---|---|---|---
1| Panic button| 1| 4| Bracket (optional)| 1
2| Quick start guide| 1| 5| Screw package (optional)| 1
3| Legal and regulatory information| 1| —| —| —
Appearance
Figure 3-1 Appearance
Table 3-1 Structure
No. | Name | Description |
---|---|---|
1 | Button |
- Press and hold both buttons at the same time for 8 seconds, and then the system enters pairing mode.
- Flashes green quickly: Pairing.
- Solid green for 2 seconds: Pairing successful.
- Slowly flashes green for 3 seconds: Pairing failed.
- On the normal status, press both buttons together once, and then the button sends alarm messages to the hub.
- Flashes green once: Sending messages to the hub.
- Flashes green for 0.5 seconds: Successfully sent messages to the hub.
- Flashes red for 0.5 seconds: Failed to send messages to the hub.
- In accidental press protection mode, press and hold both buttons together for 2 seconds, and then alarm messages will be sent to the hub.
The indicator status in accidental press protection mode is the same as that
of the normal status.
Make sure that you have enabled the accidental press protection function on
the DMSS app.
2| Indicator
Adding the Button to the Hub
Before you connect it to the hub, install the DMSS app to your phone. This manual uses iOS as an example.
- Make sure that the version of the DMSS app is 1.98 or later, and the hub is
- V1.001.0000000.7.R.220106 or later.
- Make sure that the hub has a stable internet connection.
- Make sure that the hub is disarmed.
Step 1 Go to the hub screen, and then tap to add the button.
Step 2 Tap to scan the QR code at the bottom of the panic button, and then tap
Next.
Step 3 Tap Next after the button has been found.
Step 4 Follow the on-screen instructions and switch the button to on, and then
tap Next.
Step 5 Wait for the pairing.
Step 6 Customize the name of the button, and select the area, and then tap
Completed.
Installation
Prior to installation, add the button to the hub and check the signal strength
of the installation location. We recommend installing the button in a place
with a signal strength of at least 2 bars. The button supports wall mount and
can be handheld. This section uses wall mount as an example.
You need to buy a bracket to install the button.
Figure 5-1 Installation
Step 1 Drill 2 holes in the wall according to the hole positions of the
bracket.
Step 2 Put the expansion bolts into the holes.
Step 3 Align the screw holes on the bracket with the expansion bolts, and
then secure the bracket with screws.
Step 4 Fix the button to the bracket.
- If the battery is dead, you need to replace the battery.
- Before you insert the new battery, make sure to press the buttons first, or wait 30 seconds after you take out the old one.
Configuration
You can view and edit general information of the button.
Viewing Status
On the hub screen, select a button from the accessory list, and then you can view the status of the button.
Table 6-1 Status
Parameter | Value |
---|---|
Temporary Deactivate | The status for whether the functions of the repeater are |
enabled or disabled.
- Enable.
- Only disable tamper alarm.
- Disable.
The function is only available when the version of the DMSS app is 1.96 or later, the hub is V1.001.0000000.6.R.211215 or later, and the button is V1.000.0000001.0.R.20211203 or later.
Battery Level| The battery level of the button.
- Fully charged.
- Sufficient.
- Moderate.
- Insufficient.
- Low.
Operation Mode| The working mode of the button.
LED Brightness| The brightness of LED lights.
Accidental Press Protection| The status for whether the accidental press
protection function is enabled or disabled.
Transmit through Repeater| The status of whether the button forwards accessory
messages to the hub through the repeater.
The function is only available when the version of the DMSS app is 1.96 or later, the hub is V1.001.0000000.6.R.211215 or later, and the button is V1.000.0000001.0.R.20211203 or later.
Program Version| The program version of the button.
Configuring the Button
On the hub screen, select a button from the accessory list, and then tap to configure the parameters of the button.
Table 6-2 Panic button parameter description
Parameter | Description |
---|---|
Device Configuration |
- View device name, type, SN and device model.
- Edit device name, and then tap Save to save configuration.
Area| Select the area to which the button is assigned.
Temporary Deactivate| Whether send sensor information to the alarm hub.
- Tap Enable, and then the button will send alarm messages to the hub. Enable is set by default.
- Tap Disable, and then the button will not send alarm messages to the hub.
Siren Linkage| When an alarm is triggered, the accessories will report the
alarm events to the hub and alert with siren.
Alarm-video Linkage| When an alarm is triggered, the accessories will report
the alarm events to the hub and then will link events.
Video Channel| Select the video channel as needed.
LED Brightness| Configure the brightness of LED lights. You can select from
Off, Low and High.
Accidental Press Protection| Enable Accidental Press protection to avoid
triggering unintended operations by accidentally pressing the button.
- Off : Disable the accidental press protection function.
- Press and Hold : Select Press and Hold to enable the accidental press protection function. Once enabled, you have to press and hold both buttons together to send alarm messages to the hub.
Signal Strength Detection| Test the current signal strength.
Button Test| Detect whether the button works.
Cloud Update| Update online.
Delete| Delete the button.
Go to the hub screen, select the accessory from the list, and then swipe left
to delete it.
Appendix 1 Cybersecurity Recommendations
Cybersecurity is more than just a buzzword: it’s something that pertains to
every device that is connected to the internet. IP video surveillance is not
immune to cyber risks, but taking basic steps toward protecting and
strengthening networks and networked appliances will make them less
susceptible to attacks. Below are some tips and recommendations from Dahua on
how to create a more secured security system.
Mandatory actions to be taken for basic device network security:
-
Use Strong Passwords
Please refer to the following suggestions to set passwords:- The length should not be less than 8 characters.
- Include at least two types of characters; character types include upper and lower case letters, numbers and symbols.
- Do not contain the account name or the account name in reverse order.
- Do not use continuous characters, such as 123, abc, etc. Do not use overlapped characters, such as 111, aaa, etc.
-
Update Firmware and Client Software in Time
- According to the standard procedure in Tech-industry, we recommend to keep your device (such as NVR, DVR, IP camera, etc.) firmware up-to-date to ensure the system is equipped with the latest security patches and fixes. When the device is connected to the public network, it is recommended to enable the “auto-check for updates” function to obtain timely information of firmware updates released by the manufacturer.
- We suggest that you download and use the latest version of client software.
“Nice to have” recommendations to improve your device network security:
-
Physical Protection
We suggest that you perform physical protection to device, especially storage devices. For example, place the device in a special computer room and cabinet, and implement well-done access control permission and key management to prevent unauthorized personnel from carrying out physical contacts such as damaging hardware, unauthorized connection of removable device (such as USB flash disk, serial port), etc. -
Change Passwords Regularly
We suggest that you change passwords regularly to reduce the risk of being guessed or cracked. -
Set and Update Passwords Reset Information Timely
The device supports password reset function. Please set up related information for password reset in time, including the end user’s mailbox and password protection questions. If the information changes, please modify it in time. When setting password protection questions, it is suggested not to use those that can be easily guessed. -
Enable Account Lock
The account lock feature is enabled by default, and we recommend you to keep it on to guarantee the account security. If an attacker attempts to log in with the wrong password several times, the corresponding account and the source IP address will be locked. -
Change Default HTTP and Other Service Ports
We suggest you to change default HTTP and other service ports into any set of numbers between 102465535, reducing the risk of outsiders being able to guess which ports you are using. -
Enable HTTPS
We suggest you to enable HTTPS, so that you visit Web service through a secure communication channel. -
MAC Address Binding
We recommend you to bind the IP and MAC address of the gateway to the device, thus reducing the risk of ARP spoofing. -
Assign Accounts and Privileges Reasonably
According to business and management requirements, reasonably add users and assign a minimum set of permissions to them. -
Disable Unnecessary
Services and Choose Secure Modes If not needed, it is recommended to turn off some services such as SNMP, SMTP, UPnP, etc., to reduce risks. If necessary, it is highly recommended that you use safe modes, including but not limited to the following services:- SNMP: Choose SNMP v3, and set up strong encryption passwords and authentication passwords.
- SMTP: Choose TLS to access mailbox server
- FTP: Choose SFTP, and set up strong passwords.
- AP hotspot: Choose WPA2-PSK encryption mode, and set up strong passwords.
-
Audio and Video Encrypted Transmission
If your audio and video data contents are very important or sensitive, we recommend that you use encrypted transmission function, to reduce the risk of audio and video data being stolen during transmission. Reminder: encrypted transmission will cause some loss in transmission efficiency. -
Secure Auditing
Check online users: we suggest that you check online users regularly to see if the device is logged in without authorization. Check device log: By viewing the logs, you can know the IP addresses that were used to log in
to your devices and their key operations. -
Network Log
Due to the limited storage capacity of the device, the stored log is limited. If you need to save the log for a long time, it is recommended that you enable the network log function to ensure that the critical logs are synchronized to the network log server for tracing. -
Construct a Safe Network Environment
In order to better ensure the safety of device and reduce potential cyber risks, we recommend:- Disable the port mapping function of the router to avoid direct access to the intranet devices from external network.
- The network should be partitioned and isolated according to the actual network needs. If there are no communication requirements between two sub networks, it is suggested to use VLAN, network GAP and other technologies to partition the network, so as to achieve the network isolation effect.
- Establish the 802.1x access authentication system to reduce the risk of unauthorized access to private networks.
- Enable IP/MAC address filtering function to limit the range of hosts allowed to access the device.
More information
Please visit Dahua official website security emergency response center for
security announcements and the latest security recommendations.