CROSS TOOLS ICEBOX 25 Compressor Cool Box
Specifications:
- Model: ICEBOX 25
- Type: Compressor cool box
- Dimensions: 652 x 369 x 308 mm
- Weight: 12 kg
- Protection class: ICEBOX 25 B
Product Usage Instructions
Safety Instructions:
Always adhere to safety instructions marked with specific symbols to avoid
personal and/or property damage.
Delivery Contents:
Check the package contents to ensure all components are included.
Setup:
Make sure the current input voltage is correct. Use the control panel to
lock/unlock functions such as child safety, temperature settings (Celsius),
and language selection (German/English).
Energy Saving Tips:
Follow tips provided to save energy while using the product efficiently.
Lid Adjustment:
Instructions on how to modify the lid opening direction if needed.
Maintenance, Cleaning & Defrosting:
Guidelines on how to maintain, clean, and defrost the product for optimal
performance.
Troubleshooting:
- Issue: Water inside the box
- Solution: Ensure proper drainage and sealing of the box.
- Issue: F1 Code displayed
- Solution: Adjust battery protection settings as needed.
- Issue: F2, F3, F5, F6 Codes displayed
- Solution: Contact customer service if the issue persists after restarting the product.
Warranty Information:
Details regarding the warranty terms and conditions for the product.
Ordering Spare Parts:
Instructions on how to order replacement parts for the product.
Customer Service:
Contact information for technical support and customer service inquiries.
Frequently Asked Questions (FAQ):
-
Q: How can I request a PDF copy of the user manual?
A: You can request a PDF copy of the user manual by emailing service@crosstools.de. -
Q: What should I do if I encounter error codes F7 or F8?
A: If error codes F7 or F8 are displayed, please replace the fuse and contact customer service if the issue persists.
Dear customer,
Congratulations for buying your new device from CROSS TOOLS! Please read
through these operating instructions carefully to make sure that you can fully
benefit from all features. We hope you will enjoy your new device!
General safety information
- Please read through these operating instructions carefully and make yourself conversant with the control elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a result of the non-observance of the instructions and regulations contained in the present operating instructions shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand them on together with the device should you ever dispose of it.
- Persons not familiar with the contents of these manuals may not use this device.
- The device must not be used by children.
- The device may be used by persons with reduced physical, sensory or mental capabilities or lack of experience and/or knowledge if they have been supervised or instructed in the safe use of the equipment and have understood the resulting hazards. Children are not allowed to play with the device. Keep the appliance and its cord out of reach of children.
- The main power connection of this device cannot be replaced. In case the line is damaged, the device must be scrapped.
- Do not store explosive substances such as spray cans with flammable propellants in the cooling unit.
Notes and instructions with the following symbols require particular attention:
- Any non-observance of these instructions involves the danger of bodily harm to people and/or damage to property.
- Any non-observance of this instruction bears the risk of an electrical shock which may cause damage to persons or property.
- Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be in-formed immediately, at the latest within 8 days after the date of purchase.
In addition to the basic safety precautions for avoiding accidents, please note the following:
- ATTENTION : Before performing any installation or maintenance tasks, disconnect the electrical device from the power source by pulling the plug out of the socket outlet. Switch off the main fuse of the main domestic power supply before unplugging the mains cable, if the connection plug or the main power outlet are wet. Never transport or suspend the device by the mains cable.
- Ensure that the voltage specified on the type plate of the device agrees with the mains voltage.
- Prior to connecting the device to the mains supply, ensure that the mains cable and the device are not damaged in any way.
- Parts of the packaging can be dangerous (e.g. the plastic bags) – therefore keep these out of reach of children, people who not responsible for their actions and animals.
- Only use accessories that are included in the scope of delivery, or only those that are specified in the operating manual. The use of accessories that have not been approved may impair safety.
- Any use of the device that is not described in this manual may be dangerous and must therefore be avoid-ed.
- The device must be correctly assembled with all parts before use. Check that the socket and plug match.
- Never touch the mains plug with wet hands.
- Switch off the device before maintenance, cleaning and after use, and unplug from the mains.
- Do not leave the device unattended, do not leave it within the reach of children or people who are not re-sponsible for their actions.
- Children should be supervised so that they do not play with electrical devices.
- In case of incidents (e.g. contact with cleaning agents or chemicals) clean the machine with plenty of clean water.
- In the event of a malfunction, always pull out the mains plug to avoid any danger.
- Never leave the device unattended during operation.
- Carefully check whether the mains connection cable, housing or other parts of the device are damaged; if so, do not use the device under any circumstances and contact the customer service department for re-pairs.
- If you are using extension cables, make sure that they are suitable for the application in question and that they are placed on a dry surface and protected against water spray.
- Service and repairs shall only be carried out by qualified personnel. Defective parts of the device shall only be replaced with original parts.
- The manufacturer is not responsible for any damage to persons or objects caused by improper use of the device, or by a failure to follow the instructions provided in this manual.
Special safety instructions for the compressor coolers
- Make sure that the supply voltage is in the correct range for the supply line used. The type plate on the side of the device indicates the corresponding voltage ranges.
- Check the power cable used. If it is damaged or kinked, it must not be used.
- The device may only be operated if it is in a technically perfect condition and has no damage.
- Repairs may only be carried out by qualified personnel.
- Do not place any electrical appliances in the cooler as they could be damaged.
- During transport, the device should not be tilted more than 45° and should be handled with care.
- It is recommended to operate the device on a flat surface. The maximum angle of inclination during opera-tion must not exceed 30°.
- Your device requires good ventilation.
- Leave the following free space for air circulation: Rear: 200 mm & at the sides: 100 mm
- Make sure that the ventilation openings are not covered.
- The temperature on the rear wall, but also on the entire outer surface of the cooler can be high (especially in summer) due to the heat emitted by the condenser and the compressor.
- The device must be placed in a dry and ventilated place far from heat sources (e.g. cooker, fireplace) and direct sunlight should be avoided.
- Do not fill any liquids into the inner container and do not store any corrosive or explosive substances.
- When operating from a 12 V socket: Disconnect the cooler from the power supply before using a quick charger for the on-board battery.
- Although the devices were cleaned before leaving the factory, we strongly recommend cleaning the interi-or of the cooler with a soft cloth moistened with warm water and some neutral detergent before first use. Then wipe with a dry, soft cloth.
- Moisture can form on the outside of the cooler or the door seals when it rains and the humidity is high. You can wipe damp surfaces with a dry cloth.
Intended use
This device is intended for private use and not for commercial or industrial
purposes. The mobile cooling unit is suitable for both cooling and freezing
food. The cooling unit is designed for operation by means of a DC accesso-ries
socket on a vehicle, boat or caravan or for operation on the AC mains.
The mobile cooling unit is also suitable for camping. This product is only
suitable for the intended use specified and for use in accordance with these
instructions. Any use deviating from the intended use is not permitted! Cross
Tools accepts no liability for loss, damage or injury arising directly or
indirectly from any use other than the in-tended use.
- The outside temperature and operating temperature must not exceed or undershoot the maximum or minimum temperatures specified in the technical data.
Technical data
- Model ICEBOX 25
- Energy efficiency class (EU 2019/2016) B
- Cool box power supply 12 V (DC), 24 V (DC), 230 V (AC) via mains adapter
- Mains adapter power supply 100 – 240 V~ 50/60 Hz (1.2 – 0.5 A)
- Usable volume 21 L
- Energy consumption 32 kWh/year
- Ambient temperature +16 – + 43 °C (N/ST/T)
- Cooling performance -20 – + 20 °C
- Noise level 45 dB
- USB charge connection 5 V / 1 A
- Refrigerant quantity 0.024 kg
- Refrigerant R1234yf
- Degree of protection / protection class IP20 / II
- Length of the DC (12 / 24 V) connection cable 3.5 m
- Length of the AC (230 V) connection cable 2.1 m
- Dimensions (L x W x H) 652 x 369 x 308 mm
- Net weight 12 kg
- Item no. 68062
Scope of delivery
Included in the product scope of supply are:
A compressor cooler, with 12 & 24 volt connection cable, mains adapter for 230
V~ connection, storage basket and operating instructions.
If possible, retain the packaging until your guarantee has expired. Dispose of
packing materials in an environmentally friendly manner.
Commissioning
Before using the device for the first time, it must be placed upright on a horizontal surface for at least 6 hours. Always place the cooling unit on the floor. If the cooling unit is operated in any other orientation, the unit may be damaged. It is possible to operate the device at an angle of max. 30° for short periods of time. If the device has fallen over or been stored on its side, it must also be placed upright for at least 6 hours before it is put into operation
Connecting the compressor cooler
12 V / 24 volts (DC) ➤ Plug the DC connection cable into the DC socket and
connect it to a DC receptacle. 230 volt (AC) ➤ Plug the supplied power supply
unit into a 230 V~ socket and connect it to the cooler.
Operating settings
Switching on/off
- Connect the cooler to the desired power supply.
- Press the ON/OFF button to start the device.
- Press the ON/OFF button again to switch the device off.
Setting the target temperature
Press the + (for warmer) or – (for colder) button to set the target
temperature to your preference. The device adopts the last displayed value as
the target temperature.
Changing the operating mode (Eco mode & Max mode)
ECO mode (energy saving mode) / MAX mode (fast cooling mode)
- Press the SET button ( ) to enter the ECO (economy) operating mode.
- Press the SET button ( ) again to return to MAX (maximum) mode.
- The factory setting of the cooler is MAX mode.
Setting the battery monitor
The device is equipped with a three-stage battery monitor, which is intended
to protect your vehicle battery fromdeep discharge during 12-volt operation.
If the cooling unit is operated in the vehicle with the ignition switched off,
the cooling unit switches off automatically as soon as the supply voltage
drops below the set value.
- Press the SET button ( ) for 3 seconds.
- The battery monitor level (L, M, H) set starts flashing in the display.
- The battery monitor level can be changed by pressing the SET button ( ) again.
- The following settings are available for selection: L = 9 V / M = 11.5 V / H = 12 V
- Select the desired level and wait until the flashing stops, the level is now set and is shown in the display.
NOTE : Note that the battery monitor function is always active during 12 volt operation and so the cooler may unexpectedly stop cooling and only resume operation again once the DC supply voltage is above the set battery monitor voltage.
Recommendations:
-
When using a TRAVELBOX or another battery generator as a power source, it is recommended to set the battery monitor to “L” (Low) to ensure a long operating time.
-
If the compressor cooler is connected directly to the battery of a car or commercial vehicle, the battery protection should be set to H3 (H) to ensure that the remaining battery capacity is sufficient to start the vehicle. The settings
H2 (M) and H1 (L) are only recommended in vehicles if the compressor cooler is operated via an auxiliary battery in the car or commercial vehicle. -
As a rule, the power supply via the normal 12 volt socket is interrupted in most vehicles as soon as the ignition is switched off and thus the power supply to the cool box is also switched off. However, if it is possible to draw power from your vehicle even when the ignition is switched off, we also recommend setting the battery protection monitor to H3 (H) for the reasons mentioned above.
-
Caution! Vehicles may have different output voltages, make sure that the output voltage and the input voltage match.
-
If the display shows an error (F1), set the battery monitor correctly.
ICEBOX app
- You can also conveniently control the settings described above using a wireless connection via app.
- Download the ICEBOX app from your app store.
- Before you can use the app, you must pair the ICEBOX with the app.
- Now switch on the ICEBOX via the ON/OFF button on the device.
- Open the ICEBOX app on your smartphone, select the button “Find your cool box”. You will now see the ICEBOX on your smart phone, please select it and confirm the “Pairing” on the ICEBOX with the SET button.
DESCRIPTION
The following functions and settings can be found in the app:
- current input voltage
- Lock/unlock control panel (child lock)
- Current battery capacity; (for devices with battery operation)
- current temperature
- set temperature
- ECO mode/power saving mode
- On / Off
- MAX mode / fast cooling mode
- Battery monitor high (12 V)
- Battery monitor medium (11.5 V)
- Battery monitor low (9 V)
- Home / Main menu
- Connect / Disconnect
- Settings (temperature range, Temperature unit and languages German / English)
Please note should the control panel on the ICEBOX be locked via the app (see point 2) and suddenly lose connection with the smartphone the control panel can only be reactivated by disconnecting and reconnecting the power.
Tips for saving energy
- Choose a well-ventilated location that is protected from sunlight.
- Allow warm food to cool down before keeping it cool in the cooling unit.
- Do not open the cooling unit more often than necessary.
- Do not leave the refrigerator open longer than necessary.
- Defrost the refrigerator as soon as a layer of ice has formed.
- Avoid unnecessarily low internal temperatures.
Converting the lid stop
The lid can be opened lengthwise or crosswise by changing the stop over.
Proceed as follows:
- Open the lid of the compressor cooler to change the stop side.
- Use a Phillips screwdriver to loosen the two screws of the retaining chain.
- Also remove both hinges from the lid and the container.
- Fix both hinges in the new position in the lid and in the container.
- Also fit the retaining chain to the two new fixing points.
- Now the lid stop has been converted and the cooler is ready for use again.
- Please use the picture below as a guide for disassembly and assembly
Maintenance, cleaning & defrosting
ATTENTION : Before performing any maintenance tasks, disconnect the
electrical device from the power source by pulling the plug out of the socket
outlet.
Do not use aggressive solvents or cleaning agents such as scouring agents,
bleach, soap powder, alkaline cleaning agents, petrol, acid, etc. to clean the
lid seals and plastic parts.
- Disconnect the device from the power source.
- Open the lid and remove all the refrigerated goods from the cooler.
- Remove coarse dirt and any condensation from the interior.
- Clean the inside and outside surfaces of the cooler with a soft cloth moistened with warm water.
- If heavily soiled, use a neutral cleaning agent to clean the cooler. Then rub the surfaces dry with a soft, clean cloth.
- The cleaning intervals depend on the degree of soiling of the cooler box.
- If you are going to be absent for a longer period, remove all food from the cooler and unplug it from the mains. Clean it by the instructions above and store the cooler with the lid slightly open to prevent mold. Then place the cooler in a ventilated place. The same applies if you do not use the cooler for a longer period.
- Store the device in a dry, frost-proof place.
Note : All types of repairs must be carried out by qualified personnel.
- The unit contains HFC 1234yf (2,3,3,3-tetrafluoropropene, trade name: R-1234yf) as refrigerant with a very low GWP value (global warming potential) of 4 (based on 100 years, CO2 = 1). 1234yf is a combustible, colorless gas with a faint inherent odor.
- Keep ignition sources away from the unit. The gas is under high pressure in the refrigerant circuit. There is arisk of fire and explosion if it escapes uncontrolled. Immediately take the unit out of operation and contact an authorized specialist if you suspect that refrigerant has escaped.
- All persons who work on the refrigerant circuit must be appropriately trained and have certificates from an accredited certification body.
Defrosting the cooling unit
In the following cases, the cool box must be defrosted urgently:
- Ice can form inside the cool box during prolonged operation. This reduces the cooling performance and thus also increases the power consumption. In addition, ice formation can also affect the proper closing of the lid.
- Humidity in the air can form frost inside the cooling unit, which also reduces the cooling performance. Defrost the cooling unit in good time and regularly.
Proceed as follows to defrost the cooling unit:
- Switch off the cooling box and disconnect the mains plug.
- Open the lid and remove all items from the cooling unit.
- If necessary, store the goods in another cooling unit so that they stay cold and do not thaw out.
- Leave the lid open to defrost the ice more quickly.
- Never use hard, sharp or pointed tools to remove the layers of ice or to loosen frozen items. Disregard can cause damage to the unit.
- Remove the drain plug in the base to allow the water condensate to drain out. Dry the interior with a soft cloth.
- Close the drain plug.
- The cooler is now ready for use again
Problems & faults
The following operating noises may occur during normal operation and do not indicate a malfunction:
- When starting or stopping the compressor, the refrigerant flow may cause a strong humming, gurgling or pulsating noise.
- Metallic vibration sounds may be heard from the compressor when the device starts working and the cooler starts cooling.
If the device does not operate or start:
- Check the mains connection (if using vehicle power, check the ignition).
- Check that the plug and socket have a good connection.
- Check if the fuse is blown (see paragraph Replace fuse).
- Check whether the device is or has been switched on.
- Check if any of the error messages described below are shown on the display:
Fault table and error codes
In the event of a fault, the internal device management system can display
various error codes to identify possible causes
Fault | Possible cause | Remedy |
---|---|---|
1. Food or drinks inside the cooler are frozen | 1. The temperature set is | |
too low | 1. Adjust the temperature in the panel | |
2. Food or drinks inside the cooler do not get cold | 1. The temperature set | |
is too high | 1. Adjust the temperature in the panel | |
3. Sound of running water inside the box | 1. This is a normal noise due to | |
the refrigerant flow. | 1 No remedy is necessary or possible as this noise is |
normal
4. F1 code displayed| 1. Low battery power protection activated| 1.Change
the protection from H3 (H) to H2 (M) or H1 (L)
5. F2 code displayed| 1. Fan overload protection activated| 1. Please
switch the device off, store it in a ventilated place and restart it after 30
minutes. If F2 is still displayed, please contact customer service.
6. F3 code displayed| 1. The compressor safeguard is activated| 1. Please
switch the device off, store it in a ventilated place and restart it after 30
minutes. If F3 is still displayed, please contact customer service.
7. F5 code displayed| 1. The compressor control module safeguard is
activated.| 1. Please switch the device off, store it in a ventilated place,
and restart it after 30 minutes. If F5 is still displayed, please contact
customer service.
8. F6 code displayed| 1. Hardware controller error (controller could not
recognize the normal parameters).| 1. Please switch the device off, store it
in a ventilated place and restart it after 30 minutes. If F6 is still
displayed, please contact customer service.
9. F7/F8 code displayed| 1. Temperature sensor fault| 1. Please restart the
device. If F7/F8 is displayed.
Replacing the fuse
- Switch off the cooling box and disconnect the mains plug.
- Open the cover of the fuse holder directly above the power connection and check whether the fuse is defective.
- Using long nose pliers, pull the fuse out of the fuse holder.
- If it is defective, replace the fuse with a new fuse of the same rating (15 A blade fuse, blue).
- Re-fit the protective cover and connection cable in reverse order, to allow use of the device again.
Warranty
- The present device was manufactured and inspected according to the latest methods. The seller warrants for faultless material and workmanship by the legal regulations of the country in which the device was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below:
- Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will be eliminated free of charge. Any complaints are to be reported immediately upon their detection.
- The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties.
- Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection or installation or Acts of God or other external influences are excluded from warranty.
- Parts being subject to wear and tear, such as the pump wheel (impeller), mechanical shaft seals, membranes and pressure switch are excluded from the warranty.
- All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle.
- It should be understood, however, that the wear and tear depend on the kind of use, the intensity of use and the internals of maintenance. Complying with the installation and maintenance information contained in the present operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
- In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire device.
- Replaced parts will pass into our property.
- Claims for liquidated damages are excluded unless they are caused by wilful acts or negligence on the side of the manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be evidenced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment is valid in the country in which the device was purchased.
Please note:
- Should your device fail to function properly, please verify first whether an operating error or another cause is present that cannot be attributed to a defect of the device.
- In case you have to take or send in your defective device for repair, please be sure to enclose the following documents:
- Sales receipt (sales slip).
- A description of the occurring defect (a description as accurate as possible will expedite the repair work).
- In case you have to take or send in your defective device for repair, please remove any attached parts that do not belong to the original condition of the device. If any attached parts of this kind should be missing upon the return of the device, we shall not be liable for them.
How to order spare parts
The best way to order spare parts is by e-mail or fax. Please use the e-mail
address service@crosstools.de or the fax number 07263/91 25 85.
Service
In the case of warranty claims or malfunction, please contact your point of
sale.
A current operating manual is available as required as a PDF file via e-mail:
service@tip-pumpen.de
For EC countries only
Do not throw electric appliances in your dustbin!
According to EU guideline 2012/19/EU concerning old electric and electronic
appliances and its implementation in national law, such appliances must be
collected separately and fed into an environment-friendly recycling system.
Please consult your local waste management system for advice on recycling.
T.I.P. Technische Industrie Produkte GmbH Siemensstraße 17
D-74915 Waibstadt / Germany
Tel.: +49 (0) 7263 9125-0
Fax: +49 (0) 7263 9125-85
Webseite: http://www.crosstools.de
CROSS TOOLS und das CROSS TOOLS Logo sind eingetragene Markenzeichen der
T.I.P. Technische Industrie Produkte GmbH.
CROSS TOOLS and the CROSS TOOLS Logo are registered trademarks of T.I.P.
Technische Industrie Produkte GmbH (Germany).
EC declaration of conformity
We, T.I.P. Technische Industrie Produkte GmbH, Siemensstr. 17, D-74915
Waibstadt, declare in our sole responsibility that the products identified
below comply with the basic requirements imposed by the EU directives
specified below including all subsequent amendments:
2006/42/EC, 2014/30/EU, 2011/65/EU, 2014/53/EU
Art.:
Kompressor-Kühlbox
ICEBOX 25
ICEBOX 40
applied standards/ angewendete Normen:
EN 55014-1:2021
EN 55014-2:2021
EN 50498:2010
EN IEC 61000-3-2:2019
EN 61000-3-3:2013 + A1:2019
EN 301 489-1 V1.9.2
EN 301 489-1 V2.1.1
EN 301 489-1 V2.2.3
EN 301 489-17 V3.1.1
EN 301 489-17 V3.2.4
applied standards/ angewendete Normen
EN 62233:2008
EN 300 328 V2.2.2
EN IEC 62368-1:2020 + AC:2020-05 + A11:2020
EN 60335-1:2012 + A15:2021
EN 60335-2-24:2010 + A1:2019 + A2:2019
EN 62479:2010
EN IEC 63000:2018
Documentation Representative:
CrossTools und das Logo sind Handelsmarken der
T.I.P. Technische Industrie Produkte GmbH
T.I.P. Technische Industrie Produkte GmbH
Siemensstraße 17
D-74915 Waibstadt
Telefon: + 49 (0) 7263 / 91 25 0
Telefax + 49 (0) 7263 / 91 25 25
E-Mail: info@tip-pumpen.de
References
- Das neue Batteriegesetz (BattG)
- Cross Tools – Ihr Shop für Stromerzeuger, Trennmaschinen und Pumpen
- Startseite - Das neue Elektrogesetz (ElektroG, WEEE) 2024
- Start - Pospischil - Reparaturbonus
- Start - Pospischil - Reparaturbonus
- Startseite - Das neue Elektrogesetz (ElektroG, WEEE) 2024
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>