SAFETY WARNINGS
Intended to alert the user to the presence of uninsulated ‘Dangerous
Voltage’ within the product’s enclosure that may be sufficient to constitute a
risk of electrical shock to persons.
Intended to alert the user of the presence of important operating and
maintenance (Servicing) instructions in the literature accompanying the
product.
CAUTION: Risk of electrical shock – DO NOT OPEN.
To reduce the risk of electrical shock, do not remove the cover. No user-
serviceable parts inside. Refer servicing to qualified personnel.
WARNING: To prevent electrical shock or fire hazards, do not expose this appliance to rain or moisture. Before using this appliance please read the operating instructions for further warnings.
After unpacking your amplifier check that it is factory fitted with a three-
pin ‘grounded’ (or earthed) plug. Before plugging into the power supply ensure
you are connecting to a grounded earth outlet.
If you should wish to change the factory-fitted plug yourself, ensure that the
wiring convention applicable to the country where the amplifier is to be used
is strictly conformed to. As an example in the United Kingdom, the cable color
code for connections is shown the opposite.
GENERAL INSTRUCTIONS
In order to take full advantage of your new product and enjoy the long and trouble-free performance, please read this owner’s manual carefully, and keep it in a safe place for future reference.
-
Unpacking : On unpacking your product please check carefully for any signs of damage that may have occurred whilst in transit from the HH factory to your dealer. In the unlikely event that there has been damage, please re-pack your unit in its original carton and consult your dealer. We strongly advise you to keep your original transit carton, since, in the unlikely event that your unit should develop a fault, you will be able to return it to your dealer for rectification securely packed.
-
Amplifier Connection: In order to avoid damage, it is advisable to establish and follow a pattern for turning your on and off your system. With all system parts connected, turn on source equipment, tape decks, cd players, mixers, effects processors, etc, BEFORE turning on your amplifier. Many products have large transient surges at turn on and off which can cause damage to your speakers.
By turning on your bass amplifier LAST and making sure its level of control is set to a minimum, any transients from other equipment should not reach your loudspeakers. Wait till all system parts have stabilized, usually a couple of seconds. Similarly when turning off your system always turn down the level controls on your bass amplifier and then turn off its power before turning off other equipment -
Cables : Never use shielded or microphone cables for any speaker connections as this will not be substantial enough to handle the amplifier load and could cause damage to your complete system.
-
Servicing : The user should not attempt to service these products. Refer all servicing to qualified service personnel.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC rules Operation is subject to the
following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, that may cause undesired operation.
Warning : Changes or modifications to the equipment are not approved by
HH Electronics Ltd.
can void the user’s authority to use the equipment.
Note : This equipment has been tested and found to comply with the limits
for Class B digital devices, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures.
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment to an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
—————————-
This product conforms to the requirements of the following European
Regulations, Directives & Rules: CE Mark (93/68/EEC), Low Voltage
(2014/35/EU), EMC (2014/30/EU), RoHS (2011/65/EU), ErP (2009/125/EU).
——————————
In order to reduce environmental damage, at the end of its useful life,
this product must not be disposed of along with normal household waste at
landfill sites. It must be taken to an approved recycling center according to
the recommendations of the WEEE (Waste Electrical and Electronic Equipment)
directive applicable in your country.
———————————————————————————
http://support.hhelectronics.com/approvals
-
Read these instructions.
-
Keep these instructions safe.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
An apparatus with Class I construction shall be connected to a main socket outlet with a protective connection. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus.
-
Only use attachments/accessories provided by the manufacturer.
-
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
The mains plug or appliance coupler is used as the disconnect device and shall remain readily operable. The user should allow easy access to any mains plug, mains
coupler, and mains switch used in conjunction with this unit thus making it readily operable. Unplug this apparatus during lightning storms or when unused for long
periods of time. -
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
Never break off the ground pin. Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.
-
If this product is to be mounted in an equipment rack, rear support should be provided.
-
Note for the UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ proceed as follows:
a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth symbol‚ colored green or colored green and yellow.
b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.
c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red. -
This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place objects containing liquids, such as vases, upon the apparatus.
-
Exposure to extremely high noise levels may cause permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time.
The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposures: According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Earplugs or protectors to the ear canals or over the ears must be worn when operating this amplification system in order to prevent permanent hearing loss if exposure is in excess of the limits set forth above. To ensure potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation. -
Symbols & nomenclature used on the product and in the product manuals, intended to alert the operator to areas where extra caution may be necessary, are as follows:
Intended to alert the user to the presence of high ‘Dangerous Voltage’ within the product’s enclosure that may be sufficient to constitute a risk of electrical shock to persons.
Intended to alert the user of the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
Risk of electrical shock – DO NOT OPEN. To reduce the risk of electrical
shock, do not remove the cover. No user-serviceable parts inside. Refer
servicing to qualified personnel.
To prevent electrical shock or fire hazards, do not expose this appliance to
rain or moisture. Before using this appliance please read the operating
instructions.
If your appliance features a tilting mechanism or a kickback-style cabinet,
please use this design feature with caution. Due to the ease with which the
amplifier can be moved between straight and tilted back positions, only use
the amplifier on a level, stable surface.
DO NOT operate the amplifier on a desk, table, shelf, or otherwise unsuitable
non-stable platform.
INTRODUCTION
The TNA-1800SA Active subwoofer features an HH-designed 18-inch low-frequency woofer with exceptionally high output. Equipped with integrated rigging hardware, the TNA-1800SA can be installed quickly and easily. The TNA-1800SA offers a max SPL of 138dB and offers a frequency response as low as 32Hz. The TNA-1800SA offers an ideal venue installation or point source solution.
APPLICATIONS
• Bars And Clubs.
• Live Sound Reinforcement.
• Ballrooms.| • Conference / Speech.
• Worship.
• Corporate AV events.
---|---
GETTING STARTED
This manual contains important information regarding the correct and safe
operation of your TNA system. Please read it thoroughly in order to get the
best performance and reliability from your HH product.
POWER CYCLE
Many products have large transient surges at turn on and off which can cause
damage to your speakers.
Following the sequence below for power-up and the reverse for power-down will
prevent this from occurring:
CONTROL PANEL
-
INPUT SENSITIVITY: This control sets the input sensitivity of the TNA-1800SA. Turned fully anti-clockwise, the system will accept a nominal +10dB signal such as that from a high output mixing console, whereas when set to 0dB it is more suited to lower-level inputs such as those from PA link outs. +10dB sensitivity is recommended for most setups. Increase if you need more volume.
-
XOVER CONTROL: Adjust the full range frequency limit of the sub from 70Hz(fully anti-clockwise) to 120Hz(fully clockwise).
A full range setting is also included to aid in setup and troubleshooting. -
POWER INDICATOR: Illuminates when the unit is connected to the mains power supply and switched on.
-
SIGNAL INDICATOR: Illuminates to indicate that there is a signal present at the INPUT.
-
PROTECT INDICATOR: This illuminates if a fault condition occurs. The amplifier will shut down to prevent further damage with normal operation resuming once the fault condition has been rectified.
-
LIMITER INDICATOR: Illuminates just before the amplifier begins to clip. Adjust the INPUT SENSITIVITY and/or signal level from your source so the indicator illuminates only briefly during peaks in the music. The continuous limiting of the signal will result in reduced audio quality and dynamic content.
-
PHASE SWITCH: Pressing this switch reverses the phase of the onboard subwoofer output with respect to signal input. Signals from the LINK OUT are unaffected.
-
LINE INPUT: A balanced XLR line input, suitable for balanced or non-balanced line level signals.
Please note: The Line input is not suitable for a mic-level signal. -
LINK OUT: A balanced XLR line output, suitable for sending a line-level signal to an external device.
-
LINK OUT SWITCH: With the Link switch disabled (FULL RANGE) the LINK OUT signal is sourced from the LINE INPUT. With the LINK switch enabled (XOVER), an HPF filter is applied to the LINK OUT set to the frequency determined by the XOVER Control (2).
Please refer to the block diagram on page 8. -
DELAY : Applies an audio delay to the internal loudspeaker to time align the subwoofer to your system. It can also be used to implement a cardioid function when used with the PHASE CONTROL (7) and another TNA-1800SA. The DELAY duration is set via the two onboard controls with left of the two providing millisecond increments and microseconds from the right control.
The DELAY control does not affect the audio from the LINK OUT.
WOOFER PHASE ALIGNMENT
CONTROL PANEL -
USB SERVICE PORT: For use by an authorized HH Service Centre only.
-
POWER SWITCH: Turns the system On and Off. Ensure the INPUT SENSITIVITY control to a minimum when switching it on.
-
POWER INLET: Connect the included powerCON compatible mains cable here. The TNA-1800SA contains a universal mains power supply with operating voltage from100V~ to 240V~. Ensure the mains cable is earthed.
-
MAINS FUSE: Only replace with the type specified on the rear panel.
-
VENTILATION SLOTS: Free air flow is required for the smooth and reliable operation of the system.
DO NOT block or obstruct.
-
HEAT SINK: As with the ventilation slot, please allow for free and unrestricted air flow.
-
SAFETY INFORMATION.
(powerCON is a registered trademark of Neutrik AG.
All other trademarks are the property of their respective owners)
FREQUENCY RESPONSE
BLOCK DIAGRAM
SYSTEM CONFIGURATIONS – FLOOR SYSTEM
Utilizing the TNA-1800SA to provide the LF frequency band in a PA system. The
example below comprises of the following:
1x TNA-1800SA 18-inch Active Subwoofer
1x TNA-2120SA Active 3ch Subwoofer
6x TNA-2051 Passive Full Range Satellites
SPECIFICATIONS
Specifications
Model | TNA-1800SA |
---|---|
System Type | 18″ Active Subwoofer, Direct Radiating, Bass Reflex |
Frequency Response² | 32Hz – 100Hz (-10dB) |
37Hz – 100Hz (-3dB)
LF Driver| 1×18” High sensitivity HH-designed driver. 4″ Voice Coil
Max SPL 1m³| 138 dB SPL
Crossover| Active – 70Hz to the full range
Amplifier
Power Rating| 4000W Peak, 2000W Continuous, 1000W RMS
Input Sensitivity| 0dBu to +10dBu Adjustable
Maximum Analogue Input Level| +21dBu
Input Connector| Balanced Female XLR
Output Connector| Balanced Male XLR (Switchable Full Range/Xover)
Signal Indicators| Power, Signal Present, Clip Indicator, Protect
Controls| Input sensitivity, Crossover frequency, Phase Switch, Variable Delay
(0>9.9mS)
AC Power| ~100V-240V 50/60Hz
AC Power Consumption| 350W
AC Power Inlet| Twist Lock Power Socket
Enclosure
Cabinet| Acoustically optimized 18mm plywood cabinet with extensive internal
bracing
Finish| Painted Black (White finish optional, subject to MOQ)
Mounting Points| 8x M10 Penn Elcom tie-down/flying points. 16x M8 inserts for
optional transport wheels
Grille| 1.5mm Thickness Steel, Hexagonal mesh, acoustic foam lined
Unit dimensions (HWD)| 562 x 600 x 640mm, 22.1″ x 23.6″ x 25.2″
Unit weight| 43.5Kg, 95.9 lbs
Carton dimensions (HWD)| 740 x 730 x 765mm, 29.1″ x 28.7″ x 30.1″ , 0.413 M3
Packed weight| 51.3Kg, 113.1 lbs
EAN13| 5.06011E+12
In the interest of continuous development, HH reserves the right to amend product specifications without prior notification.
2. Measured in Half space (2π) conditions.
3. Calculated maximum SPL based on rated power handling.
DIMENSIONS (in mm)
Designed and Engineered in the UK by HH Electronics LTD.
Model number:…………
Serial number:………………
Place of purchase:…………..
Date of purchase:…………………
HHELECTRONICS
HHELECTRONICS
HHELECTRONICS
WWW.HHELECTRONICS.COM
© 2022 HH Electronics Ltd
Documents / Resources
| HH
Electronics TNA-1800SA 18 Inch Active
Subwoofer
[pdf] User Manual
TNA-1800SA, 18 Inch Active Subwoofer, Active Subwoofer, 18 Inch Subwoofer,
Subwoofer
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>