Cavius 65mm Thermal Heat Alarm User Manual
- June 4, 2024
- CAVIUS
Table of Contents
Cavius 65mm Thermal Heat Alarm
Thermal Mains powered heat alarm device Commercial reference: 3202008 Developed by CAVIUS This Thermal Heat Alarm is designed for areas not suitable for smoke alarms due to the high risk of false alarms such as; kitchens, garages or workshops. PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. The maximum number of alarms that can be interlinked within a house group are 32.
Please note:
These must be alarms from the CAVIUS
SAFETY INSTRUCTIONS
The device comes with a 3V lithium battery. Batteries are to be handled with care and battery-powered devices should be kept out of reach of children. Do not try to recharge or burn the batteries.
TEST FUNCTION
- After installation, and at least once per quarter, test all of your alarms to ensure they are operating correctly and are within range of each other.
- It is recommended to check visually every week if the LED flashes correctly (every 48sec.)
- Press the test button on any alarm for 2 sweeps of alarm signal 1 (— — —) – Please refer to section 2. This will send out a test signal from the alarm; all other connected alarms should receive the signal within a short time. The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes.
- NOTE: The test function also allows to send a depleted RF signal to ensure an optimal operation in normal conditions.
- When the test signal is sent out, the alarms will respond in two ways:
- A single beep every 8 seconds indicates that the alarms are connected and functioning.
- Three short beeps every 8 seconds indicate a heat sensor fault. If required this indication can be stopped early on each alarm by a short press of the test button.
If the problem continues, please visit www.cavius.com for any troubleshooting.
NORMAL MODE
- The green LED is on when the alarm is connected to mains power. It may take up to 1 minute to indicate that mains power has been connected.
- In Normal mode, red LED will flash every 48 seconds, to show correct operations
ALARM MODE
When a rapid and constant change of temperature is detected, the heat alarm will go into ‘Alarm Mode’. It will sound the alarm signal and the LED will flash. The heat alarm will also transmit the alarm signal to the other connected alarms, which will also sound the alarm signal after a short delay. The CAVIUS Wireless Family has two different alarm signals:
- Alarm signal 1 ( ) is a life-threatening alarm.
- Alarm signal 2 ( ) is a non-life-threatening alarm.
- Smoke alarm signal: — — —
- Heat alarm signal: — — —
Please note that only the originating alarm’s LED will flash, so it can be identified.
PAUSE/HUSH FUNCTION
- If the heat alarms are to set into a false alarm by cooking, fireplace, etc. they can be paused for 10 minutes by pressing the test button on the originating heat alarm only (indicated by the flashing LED).
- NOTE: The reason of this is that it is necessary to locate the source of the alarm before using the hush function. This is to make sure that it is not a life-threatening situation.
LOW BATTERY SIGNAL
- Your product has a battery backup with a 1-year life (without mains power). And 10 years of normal life with main power.
- When the battery is starting its end of life, a short beep will sound out every 48 seconds for 30 days.
- Only the alarm, affected by the low battery, will sound. The alarm will NOT forget the connection code during the battery change process.
- It is safe to change batteries in the alarms without going through the learning process again – they will not forget the codes during the battery change process.
BATTERY REPLACEMENT
The battery is not designed to be replaced.
TROUBLESHOOTING
please visit www.cavius.com for any troubleshooting.
OTHER INFORMATION
Do not paint the alarm. Disposal: Battery not replaceable. Please dispose
properly at the end of life. This is electronic waste that should be recycled.
The heat alarm is not suitable for use as a fire safety device unless it is
part of a planned fire safety system, i.e. when interconnected to one or more
smoke alarm(s).
Complies to the Radio Equipment Directive 2014/53/EU
RF Frequency: 868 MHz.
Maximum radiofrequency power transmitted: 20 dBm
Full DoC to 2014/53/EU (RED) can be downloaded at
www.cavius.com
WARNING: All alarms should be assumed as due to actual fire and the
dwelling should be evacuated immediately.
WARNING: To prevent injury, this apparatus must be securely attached to
the ceiling/wall in accordance with the installation instructions.
WARNING: Batteries shall not be exposed to excessive heat such as shine,
fire, or the like.
WARNING: This is a mains-powered unit and can be hazardous to install. We
recommend that the installation, together with any associated supply and
interconnecting wiring, is only to be done by a professional in accordance
with BS 7671.
Note the local country regulations regarding installation.
CE
The CE mark affixed to the product confirms compliance with all relevant
European directives and harmonized requirements in the EN14604 standard and
Construction Products Regulation (CPR) 305/2011 along with the Radio Equipment
Directive (RED) 2014/53/EU for all wireless family products. All Rights
reserved: Cavius Aps assumes no responsibility for any errors, which may
appear in this manual. Furthermore, Cavius Aps reserves the right to alter the
hardware, software, and/or specifications detailed here-in at any time without
notice, and Cavius Aps does not make any commitment to update the information
contained herein. All the trademarks listed herein are owned by their
respective owners. Copy right © Cavius Aps.
Developed by CAVIUS Aps Julsøvej 16, DK-8600 Manufactured in P.R.C.
Contact: CAVIUS Ltd, Edinburgh, Scotland, EH3 9DQ Tel: +44(0)1506 896785,
www.cavius.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>