CAVIUS 2007 Smoke Alarm User Manual
- June 9, 2024
- CAVIUS
Table of Contents
User Manual
2007 Smoke Alarm
Commercial reference: 2007
Developed by CAVIUS
PLEASE READ THE USER GUIDE CAREFULLY BEFORE USE AND RETAIN FOR FUTURE
USE!
CAVIUS smoke alarm is designed for private homes, camping trailers and caravan
installations.
Safety instructions:
The device comes with a 3V lithium battery. Batteries are to be handled with
care and battery powered devices should be kept out of reach of children. Do
not try to recharge or burn the batteries.
Technical information:
Type of alarm: CAVIUS smoke alarm is a photo electric smoke alarm.
Alarm signal: Fire alarm condition is indicated by a series of repeated
tones. The minimum sound level is 85 dB at 3 meters.
Battery: Powered by a non-replaceable 3V CR123 Lithium battery with
10-year life (included).
IMPORTANT: Do not replace the battery. Replace the product if the battery
fails.
Low battery indicator: A short “beep” will sound and LED flash every 48
seconds when the battery is near the end of life. In this stage it will
continue for a minimum 30 days.
It is recommended to change the smoke alarm after 10 years, or if the alarm
has suffered any damage. The alarm is not active unless it is inserted in the
mounting base.
Always check the alarm after inserting in the mounting base (allow a few
seconds before testing).
Placement: The smoke alarm is designed for placement on a ceiling or
wall. The smoke alarm should be a minimum of 50 cm from the wall, with a
minimum of one smoke alarm per floor and a maximum distance between smoke
alarms of 10 meters.
Alarm signal: The alarm has a visual and acoustic alert tone. In the
passive state, the LED will flash every 48 seconds to indicate normal
function. In an alarming state the LED will flash and the alarm will emit a
sweeping sound pattern design to alert occupants.
Hush function: In case of unintentional alarm condition or false alarms,
press the top button. This will hush the alarm for 10 minutes, after which
time it will automatically resume its normal alarm function.
Maintenance: The smoke alarm should be vacuum cleaned once per quarter,
and it can be wiped with a damp cloth. (Do not open the alarm).
Test the alarm at least once per quarter by pushing the test button. The alarm
will self test and give a loud alarm tone.
The best places to mount the alarm:
- Place an alarm between possible fire sources and bedrooms as minimum,
- Alarms on each floor and in hallways and stairways.
- Alarms in each room such as bed rooms and living rooms.
Additional alarms increase the security.
Installation of alarm:
- Detach the alarm from the mounting base by twisting counter clockwise. Use the mounting base to mark the screw holes on the ceiling. Use the enclosed screws and plugs to install the mounting base. Once the mounting base is installed on ceiling or wall, attach the alarm by twisting clockwise.
- After mounting, test the alarm by pushing the test button on the top and get a loud alarm tone.
Please note: The label in the product must not be removed as it contains important information regarding the product.
The alarm may NOT be placed:
- In dusty rooms
- At the top of high pointed ceilings or in ceiling corners or within 50 cm of a wall.
- In rooms where the temperature goes out side +4º to 38º C or above 90% relative humidity not condensing.
- In kitchen, garage and fireplaces where damp, gases and smoke could occur. Place the alarm where it is reachable in order to test the battery and for maintenance.
Fault finding: If the smoke alarm activates without visible cause, the possible cause could be:
- Dust particles in the smoke chamber which can be re moved by vacuuming the mesh.
- High humidity condensing which can be resolved by drying the smoke alarm.
If the smoke alarm does not work when the test button is pushed, the probable cause is a faulty battery and the smoke alarm must be replaced.
Other information: Do not paint the alarm.
Disposal:
For product, please dispose properly at the end of life. This is electronic
waste which should be recycled.
Please note local regulations about information to your insurance company
regarding installed smoke alarms.
WARNING: All alarms should be assumed as due to actual fire and the
dwelling should be evacuated immediately.
WARNING: To prevent injury, this apparatus must be permanently fixed to
the ceiling/wall in accordance with the installation instructions.
WARNING: Batteries shall not be exposed to excessive heat such as shine,
fire, or the like. Note the local country regulations regarding installation.
EN 14604:2005 + AC :2008
DoP no.: 2007
The CE and RED declaration of conformity and Don can be downloaded from:
http://www.cavius.com
The paper version of the Don is available free of charge upon request.
Declared performance 4.1-4.19 + 5.2-5.24: Passed.
The CE mark affixed to the product confirms compliance with all relevant
European directives and harmonized requirements in the EN14604 standard and
Construction Products Regulation (CPR) 305/2011 along with the Radio Equipment
Directive (RED) 2014/53/EU for all wireless family products.
All Rights reserved: CAVIUS assumes no responsibility for any errors, which
may ap pear in this manual. Furthermore,
CAVIUS reserves the right to alter the hardware, software, and/or
specifications detailed herein at any time without notice, and CAVIUS does not
make any commitment to update the information contained herein.
Developed by CAVIUS, Jens Juuls Vej 28 K, DK-8260
Manufactured in P.R.C.
©2022 Carrier. All Rights Reserved.
All trademarks and service marks referred herein are property of their
respective owners.
127404 rev10
Documents / Resources
|
CAVIUS 2007 Smoke
Alarm
[pdf] User Manual
2007 Smoke Alarm, 2007, Smoke Alarm, Alarm
---|---
|
CAVIUS 2007 Smoke
Alarm
[pdf] User Guide
2007 Smoke Alarm, 2007, Smoke Alarm, Alarm