CAVIUS 9001 Smart Lock Black Instruction Manual
- June 9, 2024
- CAVIUS
Table of Contents
9001 Smart Lock Black
Instruction Manual
9001 Smart Lock Black
Commercial referral: 9001
Developed by CAVIUS
PLEASE READ THE USER GUIDE C A R E FULLY BEFORE USE AND RETAIN FOR FUTURE USE!
GENERAL DESCRIPTION
In the event of an alarm, the Smart Remote flashes quickly and it was designed to remotely control the Wireless Alarm Family of CAVIUS. Flashlight function to locate escape routes at night.
SAFETY INSTRUCTIONS
Batteries must be handled with care and battery-powered devices must be kept out of the reach of children. Don’t try to recharge or burn the batteries.
TECHNICAL INFORMATION
The Smart Remote can be used with the alarms of the Wireless Alarm Family by
CAVIUS.
Smoke, heat, flood, CO and network detectors electric. The maximum number of
alarms to be interconnected is 32. The distance minimal is 100m in open field.
The conditions RF they also depend by the structure of the house and the
materials. AND necessary verify them Always After the installation And After
there replacement of batteries.
Diameter: 27mm. Length: 140mm.
The Smart Remote is powered by 3 replaceable AAA batteries.
Compliant: RoHS, REACH, EN60065.
-
HOW TO CONNECT TO THE ALARM FAMILY WIRELESS:
Open the battery compartment by pressing button a pressure. Insert the batteries into the battery compartment respecting the polarities.
Slide the learning switch on position “Learning mode”. The Smart Remote will enter learning mode.
All alarms that need to be connected to the Smart Remote in the house must be put in “Learning mode” by sliding the switch of each device to the position “Learning Mode”.
The flashlight will turn on to indicate that it has been “Learning mode” is selected.
Note: Do not take out the batteries during “Mode learning” as this will interrupt the process of learning.
Press and hold the test button on an alarm, at your choice, until it beeps and the LED flashes. This alarm will become the master it will start sending a specific house code to the others alarms.
When other alarms will receive the house code specific, they will also start flashing their own Red LEDs.
When all alarms flash with LED red, are connected and MUST BE TURNED OFF FROM “MODE FROM LEARNING” And installed.
Label the original alarm “Learn” for easy adding new alarms CAVIUS Wireless Family to the system. -
INSTALLATION:
The body of the Smart Remote has a built-in magnet, so it can be installed on a plate metallic mounted on the wall, or on a refrigerator or other surfaces metallic.
The metal plate supplied can be installed with the double-sided tape or set of screws in endowment.
The end cap has a hole where a lanyard can be added so that the remote can be hung on a hook, etc. -
TEST FUNCTION:
After installation, and at least once a quarter, test all alarms by pressing the button test on remote control to make sure That they work correctly And they are within there scope the one of the other.
Yes recommend Of check visually Everything is fine week self The LEDs flashes correctly on the alarm (every 48sec.).
Press and hold the red end button for two steps of alarms until the remote stops flashing, ringing and vibrating.
The remote is now transmitting a test signal to your alarms. During the test, the Smart Remote will flash and beep.
Whether the Smart Remote is receiving a signal from another device, e will flash it will also ring to indicate that it is part of the group.
The indication can to be interrupted pressing the button of end.
Note: To ensure optimal operation under normal conditions, the test function sends out a reduced power RF signal. -
ALARM MODE:
When one of the connected alarms goes into alarm and sends out the RF alarm signal, the flashlight of the smart remote will start flashing rapidly (strobe).
The Smart remote control has a built-in vibrator and siren that will follow the sound pattern of the original alarm.
During the alarm, both the buzzer and the vibrator will be activated.
The torch can be switched from strobe flashing to steady on by pressing the side button.
Note: The flashlight will flash at 2 Hertz (2 times per second) to prevent activation of photosensitive epilepsy.
The CAVIUS Wireless family has two different alarm signals:
Alarm signal 1 (— — —) indicates alarms related to life or death situations, such as a smoke alarm.
Alarm signal 2 (— — —) indicates no alarms related to life-and-death situations, such as an alarm flooding.
Smoke alarm signal: — —
Heat detector signal: — —
Flooding alarm signal:
Remember that only the source alarm LED flashes, so you can be identified. -
HOW TO SILENCE AN ALARM USING THE SMART REMOTE:
** When the wireless alarm family alarms go into alarm, they can be silenced by briefly pressing the end button of the Smart remote.
• During the first 30 seconds of an alarm: press the red end button e once the remote stops ringing and vibrating, the LED keeps flashing. The remote control is now waiting to send the silence signal That Yes will start automatically within 30 seconds.
• After 30 seconds of alarm: Press once red end button and remote control will send a silence signal for 13 seconds.
If you need to silence several alarms, this can be repeated as many times as necessary.
Note:** Due to upcoming legislation, the signal of silence is transmitted with reduced power (the remote control must be within easy reach of the alarm silenced, The That it means That you should find you in the same room of the alarm).
You can silence any of your alarms in the system, as long as you are in the same room and a short distance from the alarm.
You can switch between rooms and mute the alarms by briefly pressing up to find the original alarm (the one that flashes), then check the cause of the alarm.
All other devices will also be muted.
If you silence an alarm other than the source of the alarm, the other alarms will still sound. -
FLASHLIGHT:
The flashlight can be activated by pressing the button lateral. Pressing again turns off the light.
Note: the light turns off automatically after 5 minutes. -
LOW BATTERY SIGNAL:
When the battery is running low, it sounds a short beep every 48 seconds for 30 days.
Only the device affected by the low battery will emit a signal acoustic, no other connected device will play.
AND safe to replace the batteries in the Smart Remote without having to repeat the process Of learning: no will forget the codes during the process replacement of drums. -
REPLACEMENT OF BATTERIES: AND possible to access the 3 batteries YYYY removing the cap terminal.
Replace the batteries respecting the polarities.
Always test the Smart Remote after replacement of drums.
More about this source text Source text required for additional translation information Send feedback Side panels
Caution: Risk of explosion if batteries are replaced by an incorrect type. -
MAINTENANCE AND TROUBLESHOOTING:
If the Smart Remote does not operate when the test/silence button is pressed, the probable cause is faulty batteries which need to be replaced. Refer to troubleshooting at www.cavius.com. -
HOW THE SMART REMOTE BEHAVIORS:
When the remote is: Receiving a signal from an alarm:
– vibrates, rings and the LED flashes
Waiting to send a silence signal during the first 30 seconds of an alarm:
– The LED flashes
Sending a silence signal:
– rapid vibration, sound and flashing LED for 13 seconds
Receiving a test tone:
– quick vibration and LED flashes -
OTHER INFORMATION:
Disposal: Battery and product must be disposed of correctly at the end of their useful life. Yes trafficking of electronic waste for recycling.
Compliant with Radio Equipment Directive 2014/53/EU.
Interconnection via RF: 868 MHz.
Maximum transmitted radio frequency power: 20dBm.
The complete documentation for 2014/53/ EU (RED) can be downloaded from the
website www.cavius.com
WARNING: all alarms must be considered due to an actual fire and the home
must be evacuated immediately.
WARNING: Batteries should not be exposed to excessive heat such as shine,
fire or the like. Take note of the local regulations of the country regarding
installation.
The CE mark affixed to the product confirms compliance with all relevant
European directives together with the Radio Equipment Directive (RED)
2014/53/EU for all products in the wireless family.
All rights reserved: CAVIUS Aps does not assume responsibility for errors
contained herein manual. Furthermore CAVIUS Aps reserves the right to modify
the hardware, software and/or other specifications indicated here at any time
without notice. CAVIUS Aps is not required to update the information contained
herein. All the trademarks listed here are proprietary of their respective
owners. Copyright© CAVIUS Aps.
Developed by CAVIUS Aps, Jens Juuls Vej 28K, DK- 8260. Made in China
(C) 2022 Carrier. All rights reserved:
127756 rev3
Documents / Resources
|