CAVIUS 5103 Wireless Flood Alarm User Manual
- June 9, 2024
- CAVIUS
Table of Contents
- CAVIUS 5103 Wireless Flood Alarm
- SAFETY INSTRUCTIONS
- TECHNICAL INFORMATION
- HOW TO SET UP AND CONNECT ALARMS
- THE BEST AREAS TO INSTALL THE FLOOD ALARM
- AREAS WHERE NOT TO INSTALL FLOOD ALARMS
- PLACEMENT
- ACCESSORY WALL MOUNTING BASE WITH PROBE
- Installation with adhesive tape
- TEST FUNCTION
- NORMAL MODE
- ALARM MODE
- PAUSE/HUSH FUNCTION
- ADD EXTRA DEVICE
- LOW BATTERY SIGNAL
- BATTERY REPLACEMENT
- TROUBLE SHOOTING:
- OTHER INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CAVIUS 5103 Wireless Flood Alarm
Commercial reference: 5103
Developed by CAVIUS
PLEASE READ THE USER GUIDE CAREFULLY BEFORE USE AND RETAIN FOR FUTURE USE!
- The Flood Alarm is designed to detect a leak of water from washing machines, water pipes or un-der-sink cabinets. It can also be used to detect flooded basements.
SAFETY INSTRUCTIONS
The device comes with a 3V lithium battery. Batter-ies are to be handled with care and battery pow-ered devices should be kept out of reach of chil-dren. Do not try to recharge or burn the batteries.
TECHNICAL INFORMATION
The maximum number of alarms that can be inter-linked within a house group is 32.
Please note: These must be alarms from the CAV-IUS Wireless Alarm Family.
The distance between interlinked alarms depends on the house layout and they
should always be tested after installation. It is not advised to get more than
10m distance between two alarms.
Diameter: 60mm. Height: 31mm.
The alarm is powered by a replaceable 3v CR123A lithium battery.
Complies to standards: RoHS, REACH, EMC di-rective 2004/108/EC.
HOW TO SET UP AND CONNECT ALARMS
Open the flood alarm top cover by twisting counter clockwise. Remove the Test button / Lid to access the battery and the RF learn slide switch.
Start by pulling out the battery isolation strip as shown.
Please note: The product label must not be re-moved as it contains important information regard-ing the product.
All alarms that need to be connected in the house should be put into ‘Learn Mode’ by sliding the switch on the top of the alarm to the ‘Learn mode’ position.
The red LED will light up to indicate that ‘Learn Mode’ has been selected.
Do not take out the battery during ‘Learn Mode’ as this will interrupt the
learn process.
Press and hold the test button at one alarm only, until it beeps and the LED
flashes. This alarm will become the master and will start sending out a
specific house code to the other alarms.
As the other alarms receive the specific house code, they will also flash the LED light.
When the red LED light flashes on all alarms, they are connected and MUST BE SWITCHED OUT OF ‘LEARN MODE’ and installed.
Label the original Learn alarm in order to easily add new CAVIUS Wireless Family alarms to the system.
Remount the Test button / Lid. Close the flood alarm top cover by twisting clockwise.
THE BEST AREAS TO INSTALL THE FLOOD ALARM
- Install a flood alarm where it is hard to discover possible leaks.
- Install next to washing machine, dishwasher, uder-sink cabinet or in the cellar.
- Install in basements.
Place the alarm where it is reachable in order to test the battery.
AREAS WHERE NOT TO INSTALL FLOOD ALARMS
- On the ceiling.
- On the wall (unless using accessory wall mounting base, see section 5).
- In rooms where temperature goes outside 0°C to 40°C.
Place the alarm where it is reachable in order to test the battery.
PLACEMENT
The flood alarm is designed to be placed on the floor near to possible leaks.
NOTE: If you place the flood alarm in places where a potential water leak / flood can rise higher than 2cm, there is a risk of your flood alarm beeing dam-aged. In these places we recommend wall mount-ing base with probe.
ACCESSORY WALL MOUNTING BASE WITH PROBE
NOTE: The wall mounting base with probe is an accessory option for the
flood alarm. It must be purchased separately.
For installation in basements with risk of flooding or areas with difficult
accessibility.
Installation with screws and plugs
Place the flood alarm base on the wall and the probe on the floor.
Make sure that the probe reaches required level either to the ground or down
the drain.
Installation with adhesive tape
- Choose a suitable spot. Make sure that the mounting area is stable, dry and free of dust and grease. Check that the surface is flat. Once as-sembled the Mounting base cannot be removed or repositioned.
- Attach the alarm into the socket. Make sure that the alarm has been fitted into the socket properly before you start sticking it to the wall.
- Remove the protective Foil from the adhesive tape.
- Mount the socket with the attached alarm to the wall by applying light pressure.
- Test the alarm according to the users guide of your alarm.
Note: When attached or detaching the alarm from the socket always make sure to secure the socket by holding onto the socket.
TEST FUNCTION
After installation, and at least once per quarter, test all of your alarms to
ensure they are operating cor-rectly and are within range of each other.
It is recommended to check visually every week if the LED flashes correctly
(every 48sec.).
Press the test button on any alarm for 2 sweeps of alarm signal 1 (— — —) –
Please refer to section 8. This will send out a test signal from the alarm;
all other connected alarms should receive the signal within a short time. The
alarms will emit a short beep and the LED will flash every 8 seconds for 2
minutes.
NOTE: Test function also allows to send a depleted RF signal to ensure an optimal operation in normal conditions.
When the test signal is sent out, the alarms will respond by:
A single beep every 8 seconds to indicate that the alarms are connected and
functioning.
If required this indication can be stopped early on each alarm by a short
press of the test button.
TIP: It is safe to cover the sound output hole with your finger during the
testing to minimize the sound level emitted.
Test of the water leak function
To test the water leak function, place the flood alarm on a wet cloth and it
should go into alarm.
NORMAL MODE
In normal mode the LED will flash every 48 sec-onds to show correct operation.
ALARM MODE
Flood alarm condition is indicated by a series of repeated tones.
The flood alarm will also transmit the alarm sig-nal to the other connected
alarms, which will also sound the alarm signal after a short delay.
The CAVIUS Wireless Family have two different alarm signals:
- Alarm signal 1 (— — —) is life threatening alarms, like a smoke alarm.
- Alarm signal 2 (- – -) is a non life threatening alarm, like a flooding alarm.
- Smoke alarm signal: — — —
- Heat alarm signal: — — —
- Flood alarm signal: – – –
Please note that only the originating alarm’s LED will flash, so it can be identified.
PAUSE/HUSH FUNCTION
Flood alarm can be paused for 10 minutes by pressing the test button on the
originating alarm only (indicated by the flashing LED, and after 10 minutes
goes back to normal function).
The reason that you can not pause the other alarms, only the originating
alarm, is for your own safety. It is necessary to locate the source of the
alarm to make sure that it is not a situation that needs your attention.
ADD EXTRA DEVICE
All CAVIUS interconnected alarms within the Wireless family can be added to
the system as they run on the same frequency and use the same data protocol.
This means that the wireless system can consist of a combination of smoke,
heat, flood etc.
Place all alarms into ‘Learn Mode’ and repeat sec-tion 1.
Always test connection to all devices by repeating test function section 6
after adding devices.
LOW BATTERY SIGNAL
Your product has a 5Y battery life.
When the battery is starting its end of life, a short beep will sound out
every 48 seconds for 30 days.
The alarm effected by the low battery will only beep, no other connected
alarms will sound.
It is safe to change batteries in the alarms with-out going through the learn
process again – they will not forget the codes during the battery change
process.
BATTERY REPLACEMENT
To replace the battery, detach the cover of the flood alarm by twisting
counterclockwise.
Caution: There is a risk of explosion if the batter-ies are replaced by an
incorrect type.
Replace the battery respecting the polarities.
Put the test button back, close the casing by twist-ing it clockwise, and test
the alarm.
TROUBLE SHOOTING:
In case of bad or weak signal, change the location of the flood alarm.
If the flood alarm does not work when the test but-ton is pushed or tested on
a damp cloth, the prob-able cause is a faulty battery. Check if the battery is
worn out or wet and replace it. Always test the alarm after replacement of
battery.
If the problem continues, please visit www.cavius. com for any trouble
shooting.
OTHER INFORMATION
Do not paint the alarm.
Disposal: For battery and product, please dispose properly at the end of life.
This is electronic waste which should be recycled.
Complies to the Radio Equipment Directive 2014/53/EU.
RF Frequency: 868 MHz.
Maximum radio-frequency power transmitted: 20 dBm.
Full DoC to 2014/53/EU (RED) can be downloaded at www.cavius.com
WARNING: Batteries shall not be exposed to ex-cessive heat such as shine,
fire, or the like. Note the local country regulations regarding installation.
The CE mark affixed to this product confirms its compliance with the European
Directives which apply to the product.
All Rights reserved: CAVIUS assumes no respon-sibility for any errors, which
may appear in this manual. Furthermore, CAVIUS reserves the right to alter the
hardware, software, and/or specifica-tions detailed herein at any time without
notice, and CAVIUS does not make any commitment to update the information
contained herein.
Developed by CAVIUS, Jens Juuls Vej 28 K, DK-8260
Manufactured in P.R.C.
©2022 Carrier. All Rights Reserved.
All trademarks and service marks referred herein are property of their
respective owners.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>