Translation of original operating instructions Inverter pool heat pump

EC declaration of conformity

We, T.I.P. Technische Industrie Produkte GmbH, Siemensstr. 17, D-74915 Waibstadt, declare in our sole responsibility that the products identified below comply with the basic requirements imposed by the EU directives specified below including all subsequent amendments: 2014/35/EU, 2014/30/EU, 2011/65/EU.

applied standards/ angewendete Normen:
EN 55014-1:2017 + A11:2020
EN 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013 + A1:2019
EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019
EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + Cor.:2006 + A2:2009 + Cor.:2010 + A13:2012
HD 639 S1:2002 + A1:03 + A2:10
DIN VDE 0620-1:2016 + A1:17 / DIN VDE 0620-2-1:2016 + A1:17 + EK1 510-11:2011 EN 62233:2008
EN IEC 63000:2018

T. I.P. Technische Industrie Produkte GmbH Siemensstraße 17 D – 74915 Waibstadt info@tip-pumpen.de
T. I.P. Technische Industrie Produkte GmbH Siemensstraße 17

D-74915 Waibstadt
Telefon: + 49 (0) 7263 / 91 25 0 Telefax: + 49 (0) 7263 / 91 25 25 E-Mail: info@tip-pumpen.de

Dear customer,
Congratulation for buying your new device from T.I.P.!
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
We hope you will enjoy your new device!

General safety information

  • Please read through these operating instructions carefully and make yourself conversant with the control ele-ments and the proper use of this product. We shall not be liable in the case of damage caused as a result of the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a re-sult of the non-observance of the instructions and regulations contained in the present operating instructions shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand them on together with the device should you ever dispose of it.
  • Persons not familiar with the contents of these manual may not use this device.
  • The device must not be used by children.
  • The device may be used by persons with reduced physical, sensory or mental capa-bilities or lack of experience and / or knowledge if they have been supervised or in-structed in the safe use of the equipment and have understood the resulting hazards. Children are not allowed to play with the device. Keep the appliance and its cord out of reach of children.
  • The device must not be used when people or animals are in the water.
  • The device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
  • The mains power connection of this device cannot be replaced. In case the line is damaged, the device must be scrapped.
  • Notes and instructions with the following symbols require particular attention:
    • Any non-observance of these instructions involves the danger of bodily harm to people and/or damage to property.
    • Any non-observance of this instruction bears the risk of an electrical shock which may cause damage to persons or property.
    • Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be in-formed immediately, at the latest within 8 days after the date of purchase.
    • In addition to the basic safety precautions for avoiding accidents, please note the following:
    • ATTENTION: Before performing any installation or maintenance tasks, disconnect the electrical device from the power source by pulling the plug out of the socket outlet. Switch off the main fuse of the main domestic power supply before unplugging the mains cable, if the connection plug or the main power outlet are wet. Never transport or suspend the device by the mains cable.
    • Ensure that the voltage specified on the type plate of the device agrees with the mains voltage.
    • Prior to connecting the device to the mains supply, ensure that the mains cable and the device are not damaged in any way.
  • Parts of the packaging can be dangerous (e.g. the plastic bags) – therefore keep these out of reach of children, people who not responsible for their actions and animals.
  • Only use accessories that are included in the scope of delivery, or only those that are specified in the op-erating manual. The use of accessories that have not been approved may impair safety.
  • Any use of the device that is not described in this manual may be dangerous and must therefore be avoid-ed.
  • The device must be correctly assembled with all parts before use. Check that the socket and plug match.
  • Never touch the mains plug with wet hands.
  • Switch off the device before maintenance, cleaning and after use, and unplug from the mains.
  • Do not leave the device within the reach of children or people who are not responsible for their ac-tions.
  • Children should be supervised so that they do not play with electrical devices.
  • In case of incidents (e.g. contact with cleaning agents or chemicals) clean the machine with plenty of clean water.
  • In the event of a malfunction, always pull out the mains plug to avoid any danger.
  • Carefully check whether the mains connection cable, housing or other parts of the device are damaged; if so, do not use the device under any circumstances and contact the customer service department for re-pairs.
  • If you are using extension cables, make sure that they are suitable for the application in question and that they are placed on a dry surface and protected against water spray.
  • Service and repairs shall only be carried out by qualified personnel. Defective parts of the device shall only be replaced with original parts.
  • The manufacturer is not responsible for any damage to persons or objects caused by improper use of the device, or by a failure to follow the instructions provided in this manual.

Special safety instructions – Heat pump

  • Do not install near a heat source, combustible materials or building exhaust air.
  • If the installation is not in a location with restricted access, a heat pump protection grille must be fitted.
  • To avoid serious burns, do not touch the pipelines during installation or maintenance.
  • To avoid serious burns, switch off the heat pump before carrying out any work on the refrigerant system and wait a few minutes before attaching temperature and pressure sensors.
  •  Have the refrigerant level checked when servicing the heat pump.
  • Check that there are no traces of corrosion or oil stains around the refrigerant components.
  • Have the installation, initial commissioning and maintenance of the heat pump carried out by authorised specialists only.
  • Do not start work on the heat pump until all safety instructions have been checked.
  • The device must be stable.
  • The electrical installation must function properly.
  • The hydraulic connections must be tight.
  • All unnecessary tools and objects must be cleared from the area.

Danger to life due to unsuitable water temperature!
Staying in pools with water temperatures that are too high or too low for a long time can cause overheat-ing (body temperature above 38°C) or hypothermia (body temperature below 35°C). This can lead to fa-tigue, dizziness, fainting or unconsciousness, resulting in death by drowning in the pool. Pregnant wom- en run the risk of causing deformities or brain damage to their unborn child, especially in the first three months of pregnancy.

  • Keep the water temperature in the range of 26-30°C during normal swimming operation.
  • Do not allow children and pregnant women to enter the water at water temperatures above 38°C.
  • Do not allow the water temperature to rise above 40°C.
  • If in doubt, check the water temperature with a suitable precision thermometer before entering the water.(The temperature sensor of the heat pump guarantees an accuracy of approx. ±3°C.)

Fire and explosion hazard due to leaking heat exchanger fins!
The refrigerant circuit of the finned heat exchanger contains easily combustible, odourless gas under high pressure. There is a risk of fire and explosion if refrigerant escapes in an uncontrolled manner.

  • Keep heat sources and open fires away from the heat pump.
  • Do not damage the device by drilling or setting fire to it.
  • Do not use any objects, except those permitted by the manufacturer, to accelerate the defrosting pro-cess.
  • Shut down the heat pump immediately if you suspect refrigerant leakage and contact an authorised spe-cialist.
  • The refrigerant is odourless. Always keep ignition sources away from the installation site of the heat pump.

Danger of injury when moving heavy devices!
The device is heavy! Incorrect lifting or uncontrolled tilting of the device may result in injury or damage to the device.

  • Lift, carry or tilt the device at least in pairs, never alone.
  • Ensure correct posture (straight back, safe stance, etc.).
  • Use transport aids (e.g.: Pallet truck or dolly).
  • Wear protective equipment such as safety shoes or gloves.

Intended use

This device is intended for private use at home and not for commercial or industrial purposes. Use the device on-ly for heating pool equipment.

Technical data

Model STEAM 25000
Voltage / frequency 220 – 240 V~ / 50 Hz
Max. input 1.2 kW
Heating capacity 4.2 kW
Input * 0.81 kW
COP 5.19
Min. / Max. flow rate 1.8 m³/h / 2.7 m³/h
Max. pool size 25 m³
Outdoor temperature 8 – 43 °C
Heating temperature 15 – 40 °C
Pool water PH value 6.9 – 8.0
Max. salinity 10 %
Mains cable 4.5 m
Refrigerant type / quantity R32 (difluoromethane) / 0.3 kg
Global Warming Potential GWP / CO2 equivalent 675 / 0.203 t
Evaporator type Copper fins
Compressor type GMCC
Number of compressors Single rotating
Heat exchanger Titan
Speed blower 2,400 rpm
Air flow rate 950 m³/h
Min. pumping pressure 0.23 MPa
Max. pumping pressure 1.18 MPa
Degree of protection / protection class IPX4 / I
Sound power level (10 m) 35 dB
Dimensions 42 x 29 x 38.5 cm
Net weight 20 kg
Item no. 30465

*Values determined at: Outdoor temperature: 26 °C / Water temperature: 26/28 °C / Humidity: 80%.

Scope of delivery

Included in the product scope of supply are: Pool heat pump with connection cable, connections, operating manual.
If possible, retain the packaging until your guarantee has expired. Dispose of packing materials in an environmen-tally friendly manner.

Commissioning

The device must be transported in an upright position. If it is stored or transported horizontally, it must stand upright for at least 24 hours before it may be switched on (Fig. 1).

T I P Steam 25000 Inverter Pool Heat Pump-FIG2

Placing of the heat pump
The device should be placed at least 2.5 m from the pool (Fig. 2)

T I P Steam 25000 Inverter Pool Heat Pump-FIG3

  • The future location of the device should be easily accessible for convenient operation and maintenance.
  • It must be placed on the ground, ideally on a level concrete floor. Ensure that the ground is sufficiently stable and can support the weight of the device.
  • Ensure that the device is well ventilated, that the air outlet does not face the windows of neighbouring buildings and that the exhaust air cannot flow back.
  • The device must not be installed when oil, flammable gases, corrosive products, sulphur-containing compounds or high-frequency devices are nearby.
  • To avoid soiling, do not install the device near a road or path.
  • To avoid annoying neighbours, ensure that the device is installed facing the least noise-sensitive area.
  • Operate the device as far as possible out of the reach of children.
  • Leave a free space of at least 30 cm at the sides and rear of the heat pump (Fig. 3).
  • Do not place any objects in front of or on the device. A minimum distance of 1.5 m from the front of the heat pump must be ensured.T I P Steam 25000 Inverter Pool Heat Pump-FIG4

Connecting the heat pump

  • Screw the connections incl. seals to the heat pump.
  • Now connect the pool hose coming from the circulating pump to the lower connection (
  • Now connect the pool hose in the direction of the pool to the upper connection ( ) ) (Fig. 4).
  • Secure each hose with hose clamps to prevent them from slipping down.T I P Steam 25000 Inverter Pool Heat Pump-FIG6
  • A 10mA differential circuit breaker is integrated in the electrical plug of the heat pump. Before connecting your heat pump, please ensure that the socket outlet has a properly installed protective contact. The heat pump must never be operated without a pump, otherwise it may be damaged. The filter pump should work at the same time as the heat pump, so you must connect it to the same circuit.
  • It is recommended to install a pre-filter. This must be cleaned regularly to ensure that the water in the sys-tem is clean, thus avoiding the operational problems associated with dirt or clogging of the filter. The water treatment system (chlorine or salt dosing system), on the other hand, must be installed after the heat pump (Fig. 5).T I P Steam 25000 Inverter Pool Heat Pump-FIG8

Connecting the personal protection switch (PRCD plug)

Switch explanation

  1. RESET → Reset
    Activates the protection

  2. POWER → Red indicator
    Protection active

  3. TEST
    Activate the test function

Test the device before use:

  • Insert the plug into the socket.
  • Press the “RESET” button: The display must be “on”.
  • Press the “TEST” button: The display must be “of f”.
  • Press the “RESET” button for use: The display must be “on”.
  • Caution: do not use if “TEST” fails.
  • This is not an overload protection, but a personal protection switch.
  • In the event of an electrical leak, the device automatically shuts off the power supply and pre-vents electricity from entering the human body.
  • The device should be connected directly to a power outlet. Power supply via an extension cable is not recommended.
Technical data PRCD plug
Voltage / frequency 220 – 250 V~ / 50 – 60 Hz
Rated current 10 A / 16 A
Trip leakage current 10 mA / 30 mA
Trip time < 0.1 s
Degree of protection IP54

Operation

  1. Current LED
  2. Defrost LED
  3. Button: ON/OFF
  4. Button: Select
  5. Button: Up (+)
  6. Button: Down (-)
    Before starting the heat pump, the filter pump must be checked for correct operation.
    The heat pump must never be operated without a pump.

Heating

  • Press to switch on the device
  • Use and to set the desired temperature
  • Now the device heats up to the desired temperature and then switches off automatically.
  • If the temperature of the incoming water is lower than the set temperature ( -1 °C), the heat pump switches to heating mode. The compressor stops if the temperature of the incoming water is higher than the set temperature.
  • Under normal conditions, a suitable heat pump can warm the water in a swimming pool by 1°C to 2°C per day. It is therefore normal not to feel any temperature difference in the system when the heat pump is in operation. A heated swimming pool should be covered to avoid any heat loss and thus be more efficient

Querying of parameters:

  • Press until the settings menu appears
  • Use and to see the parameters
  • Press to switch to the main screen

Parameter table

Code Description Factory setting
A Water inlet temperature Current data
b Water outlet temperature Current data
c Ambient temperature Current data
d Temperature set 27 °C
E Automatic defrost activation time 40 min
F Maximum defrosting time 30 min
H Set temperature difference for the restart 3 °C
J Automatic restart 1
O Frost protection – low air temperature 8 °C
P Evaporator temperature for entry into defrost mode -3 °C
U Evaporator temperature to exit defrost mode 20 °C
t Reserved – do not change Reserved

Maintenance

  • ATTENTION: Before performing any maintenance tasks, disconnect the electrical device from the power source by pulling the plug out of the socket outlet.

  • Do not use aggressive solvents or cleaning agents.

  • Do not dispose of pool water containing chemicals (e.g. chlorine) on lawns or plants.

  • The evaporator on the back of the heat pump must be cleaned carefully with a hoover and a soft brush attachment.
    Note: All types of repairs must be carried out by qualified personnel.

  • Annual maintenance:

    • Carry out security checks.
    • Check the integrity of the electrical wiring.
    • Check the earth connections.
      Your heat pump is designed to work even in rainy weather and is protected from frost by specially developed anti-frost technology. However, it is not recommended to leave them outdoors for long periods (e.g. over winter). After draining the pool, store the heat pump in a dry place for the winter.

Help in case of faults:

Code Fault Possible cause Remedy

P1

| ****

Fault in the water inlet temperature sensor

| Sensor poorly connected| Reconnect sensor
Sensor defective| Replace sensor
Defective control panel| Replace control panel
P3| Fault in the evaporator temperature sensor| ****

Same causes as P1

| ****

Same causes as P1

P5| Fault of the external temperature sensor
P7| Freeze protection| Protection is activated when the ambient temperature is too low| No input is required


E3

| ****

Flow sensor fault

| Not enough water in the heat exchanger| Review the operation of your water circuit
Defective flow sensor| Replace flow sensor
Defective control panel| Replace control panel
E6| Negative pressure protection| Insufficient refrigerant gas| Refill refrigerant gas

Warranty

The present device was manufactured and inspected according to the latest methods. The seller warrants for faultless material and workmanship in accordance with the legal regulations of the country in which the device was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below: Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will be eliminated free of charge. Any complaints are to be reported immediately upon their detection. The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties. Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection or installation or Acts of God or other external influences are excluded from warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller), mechanical shaft seals, membranes and pressure switch are excluded from warranty.

All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle. It should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the internals of maintenance. Complying with the installation and maintenance information contained in the present operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.

In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire de-vice. Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by wilful acts or negligence on the side of the manufacturer. The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be evi-denced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment is valid in the country in which the device was purchased.

Please note

  1. Should your device fail to function properly, please verify first whether an operating error or another cause is present which cannot be attributed to a defect of the device.
  2. In case you have to take or send in your defective device for repair, please be sure to enclose the following documents:
    • Sales receipt (sales slip).
    • A description of the occurring defect (a description as accurate as possible will expedite the repair work).
  3. In case you have to take or send in your defective device for repair, please remove any attached parts which do not belong to the original condition of the device. If any attached parts of this kind should be missing upon the return of the device, we shall not be liable for them.

How to order spare parts

The fastest, most simple and cheapest way of ordering spare parts is through the internet. On our website www.tip-pumpen.de you will find a convenient spare part shop where you can order spare parts with just a couple of clicks. In addition, this is also the place where we publish comprehensive information and valuable tips on our products and accessories, introduce new devices and present current trends and innovations in the range of pump technology.

Service

In the case of warranty claims or malfunction, please contact your point of sale.
A current operating manual is available as required as a PDF file via e-mail:

For EC countries only
Do not throw electric appliances in your dustbin!
According to EU guideline 2012/19/EU concerning old electric and electronic appliances and its implementation in national law, such appliances must be collected separately and fed into an environment-friendly recycling system. Please consult your local waste management system for advice on recycling.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals