WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK -The pump cannot be used while people
are inside the pool.
WARNING – TO REDUCE THE RISK OF INJURY, do not permit children to use
this product unless they are closely supervised at all times.
WARNING – RISK OF ELECTRIC SHOCK. Connect only to a grounding-type
receptacle. This product is provided with a ground-fault circuit interrupter.
If replacement
of the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit interrupter
(GFCI).
To test the GFCI, push the test button. The GFCI should interrupt power. Push
the reset button. Power should be restored. If the GFCI fails to operate in
this manner, the GFCI is defective. If the GFCI interrupts power to the pump
without the test button being pushed, a ground current is flowing, indicating
the possibility of an electric shock. Do not use this pump. Disconnect the
pump and have the problem corrected by a qualified service representative
before using.
CAUTION – To reduce the risk of electric shock the pool must be installed
no closer than 6 feet (1.8 m) from any electrical outlet. Do not place
portable appliances closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid. DO NOT BURY THE CORD. Locate cord to minimize abuse from
lawnmowers, hedge trimmers, and other equipment.
WARNING – To reduce the risk of electric shock, replace the damaged cord
immediately. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
WARNING – To reduce the risk of electric shock, do not use an extension
cord to connect unit to the electric supply; provide a properly located
outlet.
CAUTION – This pump is for use with storable pools only. Do not use with
permanently installed pools. A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its
original integrity. A permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for
storage.
CAUTION – For continued protection against possible electric shock this
unit is to be mounted to the base in accordance with the installation
instructions.
IMPORTANT – Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK – When working with electricity, turn the
electrical power off at the circuit breaker and lock the breaker door. Failure
to do so will result in an increased risk of shock, injury, and possibly
death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY.
DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions
related to the validity of your plugs grounding. Handle the pump with care. Do
not pull or carry the pump by the power cord. Never pull a plug from the
outlet by yanking the power cord. Keep cord free from abrasions. Sharp
objects, oil, moving parts, and heat should never be exposed to the filter
pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing
parts at the time of purchase. Verify that the equipment components represent
the filter pump model that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to the position of
pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place a pump in an area that may accumulate water, or in an
area where foot traffic will flow around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of
your filter pump. Unnecessary wear and tear may occur during periods of cold,
heat, and exposure to sun. Whenever possible shelter the pump from these
conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed
by adults.
- THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
- FOR USE WITH SWIMMING POOLS ONLY.
- CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
- WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING-TYPE RECEPTACLE.
- CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY – DO NOT USE WITH PERMANENTLY INSTALLED POOLS.
- CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
- CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN
IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
• WARNING – RISK OF ELECTROCUTION
- Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin
- Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
- Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
- Do Not Touch Plug With Wet Hands
- Double Insulated – When Servicing Use Only Identical Replacement Parts.
- Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any in+terference received,
including interference that may cause undesired operation.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician for help.
A | A | |
---|---|---|
P61730 | 2 | 2 |
P6113 | 2 | 2 |
P61731 | 1 | 1 |
P61732 | 1 | 1 |
P61733 | 1 | 1 |
58505/58095 | 1 | 1 |
P61734 | 1 | 1 |
P61735 | 1 | 1 |
P61736 | 2 | 2 |
P61738US | 1 | 1 |
P61739 | 1 | 1 |
P6019 | 2 | 2 |
P6517 | 2 | 2 |
P6124 | 5 | 4 |
P6005 | 2 | 2 |
P6029 | 3 | 3 |
P6916 | 2 | 2 |
P61408 | 1 | 1 |
P6680 | 2 | 2 |
P61318 | 1 | 0 |
PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on the ground or a certain pedestal
made of wood or concrete before use. There should be two holes 7mm in diameter
on the pedestal, the space between which should be 256mm. Put filter pump on
the pedestal and fix them together by fastening the bolts and nuts. All the
pedestal parts should weigh over 18kgs at least to prevent the pump from
accidentally falling.
Operation
- Open/unscrew the Air Purge Valves on the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe away any water.
- Test the GFCI plug.
- Start the Filter Pump by turning on the switch to the “I” position.
GFCI Test
A. To test the GFCI plug, insert it into a grounding-type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter
pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your local Bestway Customer Service.
NOTE: Never operate pump while the connection valves are closed.
NOTE: To prevent the risk of electrical shock, ensure your hands are
completely dry when plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP – Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter
Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY
MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump refer to pool’s manual.
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose. If filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the Valve A and B.
- Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons we suggest replacing the Filter Cartridge with a new one every two weeks.
PUMP STORAGE
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40ºC (39.2-104°F)
- Drain the pool according to the Pool Owner’s Manual.
Pump Warranty
For information concerning pump warranty please visit our website at: www.bestwaycorp.com
FAQS
Will this work with a summer waves quickset 10ft ring pool?
As long as the pool can with 300-15, 200 gal pools you should be fine.
Where can I find a new o ring for this pump?
Most pool supply stores have them
Will this work with the Bestway inflatable kids pool, 8’x20”?
Yes, for use with most 300-2,220 gallon above-ground swimming pools.
Will the hoses that come with this system match up with the hoses from a Intex 1500 gph pump and filter?
As long as the hoses are 1.25 and 1.5 inches, it will fit.
How many hours can this pump stay on constantly?
I ran mine nonstop but that will cause it to burn out faster. I accepted that
fact but wanted water constantly circulating. These are tiny motors.
It’s not recommended….likely 4 to 6 hours per day. Depending on your pool
size, which is why it’s important to get a big enough pump for the size pool
you have.
Will this work on a Coleman 18×48 pool
Yes, this will work with your Coleman 18 x 48 Pool.
Does this work for a pool that holds 10,668 gallons?
Yes. It is recommended for use with 300 to 15,200 gal pools. One size
Does it work with 220v?
Yes, this pump is 110v -120V.
Does this work with steel pro max?
A Steel Pro Max is a 1,710 gal. and this filter is used with most 300-2,220 gallon above-ground swimming pools.
I have Bestway Steel Pro 8’ x 6 ‘ that came without a pool filter pump – is this a good choice as it only holds about 500 gallons ?
For use with most 300-8,400-gallon above-ground swimming pools.
How loud is this pump?
Not any louder than other pool pumps. Mine works great. Cleans my 18′ round pool great. Would recommend.
Video
For support please visit us at: www.bestwaycorp.com/support
©2018 Bestway Inflatables & Material Corp.
All rights reserved
®™ Trademarks used in some countries under license to/
Bestway Inflatables & Material Corp., No.3065 Cao An Road, Shanghai, 201812,
China.
Manufactured,distributed and represented in the European Union by/
Bestway (Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese
(Milano), Italy
Bestway (USA) Inc., 3411 E. Harbour Drive, Phoenix, Arizona 85034, United
States of America Tel:1-855-838-3888
(For U.S. and Canada)
Distributed in Latin America by
Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea,
Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, 98-104
Carnarvon Street, Silverwater, NSW 2128, Australia
www.bestwaycorp.com
Made in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>