Specifications
- Voltage: Standard 120V
- Wattage: 9W
- Frequency: 60Hz
- Beam Angle: Adjustable Eyeball Gimbal
- Weight: Lightweight design
- Housing Material: Durable metal
- Dimmable: Yes, compatible with recommended dimmers
- Average Lifetime: 35,000 hours
- Lumens: 900LM
- Moisture Rating: Damp locations
- CRI (Color Rendering Index): 80+
- Usage: Indoor
- IC Rated: Yes
- Warranty: 7 Years
Product Usage Instructions
Before You Start – Safety Information
To reduce the risk of fire, electric shock, or physical injury, follow these safety guidelines:
- Turn off the circuit breaker before installation.
- Avoid exposure to water.
- Comply with local building codes and regulations.
- Do not install near heat sources or sensors.
- If the product is damaged, do not use it.
Quickstart Guide
- Step 1: Use the installation template to cut the hole in the ceiling.
- Step 2: Connect the supply and junction wires.
- Step 3: Attach the fixture to the junction box.
- Step 4: Insert the fixture into the ceiling.
Installation Guide
Step 1
- a. Turn off the circuit breaker before installation.
- b. Cut out a 4.33-inch hole on the Installation Template and tape it onto the ceiling at your desired location.
- c. Cut the ceiling hole using the Installation Template as a guide.
Step 2
- a. Open the junction box and remove the appropriate knockout.
Step 3
- a. Thread the cable connector through the knockout, secure wires with screws, attach cable connector nut on the opposite side, and connect supply and junction wires with wire nuts (Black to Black/Live; White to White/Neutral).
- b. Tuck connected wires inside the junction box and close the cover.
Step 4
- Note: This step applies exclusively to the Selectable Slims.
- Slide the CCT Switch to choose from 5 color temperatures – 6000K, 5000K, 4000K, 3000K, 2700K.
- Insert the junction box through the ceiling hole.
- For New Construction: Secure to studs, joists, or similar fixed structural units.
- For Remodel: Not required to secure to studs or joists.
Step 5
- a. Attach the fixture to the junction box using the connector as shown in the image.
- b. Tighten the connector by hand.
- c. Raise spring clips to insert the luminaire in the ceiling opening.
- d. Turn on the circuit breaker and test the light.
FAQ
Common Troubleshooting
If your light isn’t turning on:
- Double-check if the fixture is properly connected.
- Ensure that the circuit breaker hasn’t been tripped.
If your light unexpectedly fails, please contact our support team for assistance.
Whats in the Box
Slim Downlight
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- Professional installation required. Safety gear recommended.
- Abide by regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before installing. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Use safety precautions & abide by regional & local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices
WARNING:
Cancer & Reproductive Harm-
www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
- Step 1
- Use template to cut hole
- Step 2
- Connect supply & junction wires.
- Step 3
- Attach fixture to junction box.
- Step 4
- Insert fixture into ceiling.
Installation Guide
- STEP 1
- Turn off circuit breaker before installation.
- Cut out 4.33” housing size on Installation Template, then tape onto ceiling in desired location.
- Cut ceiling hole using Installation Template as a guide.
- STEP 2
- Open junction box and remove appropriate knockout.
- STEP 3
- Thread cable connector through knockout, secure wires with screws, attach cable connector nut on opposite side, & connect supply & junction wires with wire nuts. -Black to Black (Live) ; White to White (Neutral)
- Tuck connected wires inside junction box & close cover.
- STEP 4
- Note: This step applies exclusively to the Selectable Slims.
- Slide the CCT Switch to choose from 5 color temperatures.
- Insert junction box through ceiling hole.
- New Construction: Secure to studs, joists, or similar fixed structural units. Remodel: Do not require to secure to studs, joists, or similar fixed units.
- STEP 5
- Attach fixture to junction box using connector as shown on image (1).
- Tighten connector by hand (2).
- STEP 6
- Adjust flexible optic position to aim light beam where needed. Gimbal rotates 360° and tilts 35°.
- Raise spring clips to insert the luminaire in the ceiling opening. Turn on circuit breaker & test the light.
Product Details
Recommended Dimmers
Specifications
Common Troubleshooting
We’ve got you covered! Our troubleshooting section is here to shed some light
and provide you with easy-to-follow solutions for any problem
If you still need some assistance, feel free to contact us. Our team of
lighting experts are happy to help brighten your day.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting. An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more. It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry-leading 7-year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
30 Day Return Policy
At Sunco, we value our customers and stand by the quality and performance of our products. If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your
needs! Contact us at:
Email: support@sunco.com Call or Text:
844-334-9938
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>