PENTAIR Simer 6 Drainage Pump Flat Suction
Specifications:
- Model: Simer 6
- Model Variants: Simer 6S
- Intended Use: Submersible pump for pumping sewage, rainwater,
groundwater, seepage water, or drainage water
Product Description:
The Simer 6 is a submersible pump available with or without level control
(Simer 6S). It is designed for continuous operation in submerged conditions
Product Safety:
It is important to follow all safety instructions provided in the manual.
The pump should not be operated in explosive environments. Disconnect the
power plug before any maintenance or installation work. Take precautions
against freezing to prevent damage to the pump.
Installation:
- Do not lift the submersible pump by the power cable. Use a rope or chain for lowering into position.
- Ensure proper grounding and electrical connections.
- Place the pump in a suitable location for optimal performance.
Operation :
- Ensure the pump is not exposed to freezing conditions. The built-in thermal protector will shut off the pump if temperatures rise excessively to prevent damage.
- Use the pump for tasks such as emptying water from core drilling or concrete cutting, and switch between manual and automatic operation modes as needed.
Maintenance:
If the pump fails to operate, check for common issues like clogged filter
or hose blockages. Replace worn components like the impeller when necessary.
FAQ:
-
Q: What should I do if the pump does not start?
A: Check for clogged filters or hoses, ensure proper power supply, and inspect the impeller for wear. Refer to the maintenance section for detailed troubleshooting steps. -
Q: Can the pump be used in freezing conditions?
A: The submersible pump should not be allowed to freeze. Remove it from water and drain water if there is a risk of freezing. The built-in thermal protector helps prevent damage due to freezing temperatures.
SIMER 6
GENERAL
- You have purchased a product from JUNG PUMPEN, and therefore invested in quality and performance. To ensure that this product can deliver its high performance and operate to your complete satisfaction, please carry out the installation work in accordance with the instructions.
- It is important that, before starting any work, each person has read and understood this instruction manual. The instructions must be kept available at all times at the site of the product. If the product is passed on to a third party, the instruction manual must be passed on with it. The manufacturer accepts no liability for any damage resulting from the failure to observe this.
Intended use
- The Simer 6 submersible pump is a mobile pump that is to be used exclusively for pumping sewage, rain-water, groundwater, seepage water or drainage water.
- Use for any other purpose or installation in non-approved areas is deemed to be improper use. Any liability claims or warranty claims against the manufacturer are thereby excluded.
- The specifications in the technical data must be observed.
- Note!
The Simer 6 submersible pump must NEVER be operated in explosion hazard areas or be installed in a pump chamber.
- Note!
Supply package
Component | Quantity | Note |
---|---|---|
Simer 6 submersible pump | 1 | Optionally with level control (Simer 6S) |
Non-return valve | 1 | |
Hose connection 1″, ¾” and ½” | 1 |
SAFETY
The safety instructions in this instruction manual are marked with symbols and
must be strictly followed! Failure to follow these instructions can be
dangerous!
Qualification of staff
- This appliance can be used by children aged 8 years or over and by persons with limited physical, sensory or intellectual capabilities, or with limited experience and knowledge, pro-vided that they are supervised or have been instructed in the safe use of the appliance and are aware of the dangers involved. Children must NOT be allowed to play with the appliance. Cleaning and user maintenance must NOT be carried out by children unless they are supervised.
- If this appliance is fitted with a mains power cable that does not have a plug or other device to switch off the mains power, then the customer must install a mains disconnection device in the permanent electrical installation in accordance with the installation regulations. This disconnection device must completely disconnect the appliance from the power supply. It could take the form of a mains switch of over-voltage category III. For safety reasons, if the mains power cable of this appliance is damaged, it must be replaced by the manufacturer or his customer service department, or by a similarly qualified person.
Task | Personnel | Skills |
---|---|---|
Operation/visual inspection | Operating company / machine operator | |
Maintenance | Operating company / machine operator | |
Maintenance | Qualified installer | Qualified electrician |
Personnel must have suitable qualification for the type of work. The area of
responsibility, competence and monitoring of personnel must be precisely
regulated by the operating company. If personnel do not have the necessary
skills, they must be instructed and trained accordingly.
Responsibility of the operating company
Installation and operation of the product must be carried out according to
current technical codes of practice.
- Note!
In EU countries and the countries of destination, the standards, regulations, rules and directives that apply in that country must be implemented.
Like any other electrical device, this product can fail due to the absence of mains power or due to a technical fault. If damage or consequential damage occur due to failure of the device, take the following precautions at your discretion:
- Installation of a water level-dependent alarm, that is either dependent or independent of the mains power supply, so that the “high water” alarm can be perceived before damage occurs.
- Check the collecting tank/chamber used to ensure it is leak-tight up to the upper edge before putting the product into operation.
- Installation of backflow protection devices for drainage objects where damage can occur due to waste-water leakage after product failure.
- Installation of an additional product that can compensate for the failure of the product.
- Installation of an emergency power generator.
Unauthorised alterations, spare parts and accessories
- Alterations or modifications to the product are permissible only with the written approval of the manufacturer.
- Use only the manufacturer’s original spare parts and accessories.
- Unauthorised alterations and the use of non-original spare parts and accessories may result in a loss of warranty and liability for the products and for any consequential damage.
General safety
- Note!
In EU countries and the countries of destination, the standards, regulations, rules, and directives on accident prevention that apply in that country must be implemented.
ATTENTION!
- The instructions and warnings in this manual must be complied with!
- Wear personal protective equipment.
- Hazardous pumped fluids must be discharged in such a way that there is no danger to per-sons or the environment!
- Components and products that have come into contact with hazardous pumped fluids must be decontaminated.
- All safety and protective equipment must be re-installed and re-activated immediately after work has been completed. Next, check that all functions are working properly.
PRODUCT DESCRIPTION
Simer 6 without level control
Simer 6S with level control
Ambient conditions
Pump motor not submerged | Continuous operation S1 |
---|---|
Pumped medium | Minimum: 1 °C – maximum: 50 °C |
Transport/storage
- The submersible pump must be moved or lifted only by its carry handle.
- When stored in dry conditions, the submersible pump is frost-resistant down to -20 °C.
Never use the power supply cable to move or lift the submersible pump!
Use the rope or chain to lower the device into place.
- Never use the power supply cable to move or lift the submersible pump!
- Use the rope or chain to lower the device into place.
EMC
When our standard submersible pumps and accessories are installed as specified
and used as intended, the products meet the protective requirements of the EMC
Directive 2014/30/EC, and are suitable for domestic and commercial use when
connected to the public power supply network. If connected to an industrial
power supply network within an industrial facility, where the power supply is
provided by an in-house high-voltage transformer, there may be insufficient
immunity to interference.
INSTALLATION
OPERATION
Connecting the pump permanently to the building’s drainage system or using it to protect against back- flow (EN 12056-4) is not permitted.
- The submersible pump is not suitable for pump-ing aggressive media!
- The submersible pump must not be operated unless the foot strainer is fitted!
- The submersible pump must not be operated unless it is in an upright position!
Mains power connection
Connect the submersible pump only to a socket that has been properly installed
in accordance with the regulations and is fitted with at least a 10 A (delay)
fuse and a residual-current circuit breaker(≤30 mA).
- Warning!
- Once the submersible pump has cooled down, it will switch on again automatically! Danger of injury!
Never touch or hold the submersible pump during its cooling down phase.
Mobile use
The submersible pump pumps water from a minimum depth of 5 mm. Draining roof
areas, patios, puddles on outdoor surfaces
- Emptying flooded cellars, swimming pools, garden ponds, excavation pits
- Extracting
wastewater from borehole drilling or concrete cutting operations
Level control Can be switched between manual and automatic operation
-
Manual operation
The pump is switched on, regardless of the water level. -
Automatic operation
The submersible pump is switched on and off depending on the water level.
Automatic operation with follow-up time
- The end of the pumping process is determined by a dynamic follow-up time.
- This varies between 3 and 90 seconds depending on the inflow rate.
- If the main power plug is disconnected, the follow-up time will be reset.
SERVICING/MAINTENANCE
Note!
Water that is rich in iron or lime can damage the seals and thus also the
pump’s motor over time.
- Check the power supply cable for mechanical and chemical dam-age. Damaged cables must be replaced.
- Clean the submersible pump at regular intervals, as the hardness of the water dictates.
- Clean the pump strainer and electrodes (Simer 6S) at regular intervals
FAULTS
Fault | Cause | Action |
---|---|---|
Pump does not pump | On-site fuse/residual-current circuit breaker tripped or | |
faulty | Check the on-site fuse/residual-current circuit breaker. If this keeps |
occurring, have this checked by an electrician.
- The winding thermostat of the pump has been triggered
- The venting system is clogged
|
- Check whether the pump housing is hot
- Allow the pump to cool down
- Clean the venting port
The impeller is blocked| Solids and fibres in the pump housing| Clean the pump
housing
Decreased pumping performance| The strainer is blocked.
The discharge hose is blocked.
| Clean
The discharge hose is kinked/ bent.| Lay the discharge hose without any kinks.
The impeller is worn| Replace impeller
Technical data
Dismantling/disposal
- When disposing of the device, relevant national disposal regulations must be observed.
Declaration of Conformity
- EN – Directives – Harmonised standards FI
- 2006/42/EG (MD) EN ISO 12100:2010, EN 60335-1: 2012/A15:2021, EN 60335-2-41: 2021/A11:2021
- 2011/65/EU (RoHS)
- 2015/863/EU (RoHS) EN IEC 63000:2018
- 2014/30/EU (EMC) EN 55014-1: 2017/A11:2020, EN 55014-2:1997/A2:2008, EN 61000-3-2:2014, EN 61000-3-3:2013
- We hereby declare, under our sole responsibility, that the product is in accordance with the specified Directives.
- SIMER 6 (OD6601G-06)
- SIMER 6 (OD6601G-06-S)
- SIMER 6 (OD6601CH-06)
- SIMER 6 (OD6601UK-06)
- SIMER 6 (OD6601AU-06)
- SIMER 6 (OD6601AU-06-S
- SIMER 6 (OD6601G-06-W)
- SIMER 6 (OD6601G-06-WS)
- SIMER 6 (OD6601-110UK-06)
- SIMER 6 (OD6601-110UK-06-S)
- Authorized person for technical documentation
- Jung Pumpen GmbH Pentair Water Italy Srl Pentair Water Polska Sp. z o.o.
- Industriestr. 4-6 Via Masaccio, 13 ul. Plonów 21
- 33803 Steinhagen 56010 Lugnano – Pisa 41-200 Sosnowiec
- Deutschland Italia Polska
- Tel. +49 5204 170 Tel. +39 050 716 111 Tel. +48 32 295 1200
- kd@jung-pumpen.de
- info@jung-pumpen.it
- infopl.jungpumpen@pentair.com
PENTAIR and PENTAIR JUNG PUMPEN are trademarks, or registered trademarks of Pentair or its subsidiaries in the United States and/or other countries. © 2023 Pentair Jung Pumpen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>