Warning: While the megohmmeter is turned on do not touch both metal leads from the megohmmeter at the same time, you may get shocked.
Step 1: Remove the loop leads from the operator or detector.
Step 2: Attach the clip of the megohmmeter to an earth ground such as the operator frame or a 12″ screwdriver driven into the ground. You can pour water on the screwdriver to help ground the connection.
Step 3: Touch the probe from the megohmmeter to one of the disconnected loop lead-ins.
Step 4: Set the dial on the megohmmeter to either MΩ position. This
meter has two positions:
MΩ Power Lock which keeps the meter on and MΩ which requires that
you press and hold the POWER ON/OFF Button. The green ON light will flash when
the megohmmeter is on.
Step 5: Press and hold the power ON/OFF Button. Or if you prefer set the dial on the megohmmeter to M POWER LOCK position this will keep the meter on without having to press the ON/OFF Button.
Step 6: Read the Meter.
Look at the megohmmeter needle position:
(Optional) Step 7: Water down the area of the loop and lead-in and then
take another reading. Loops often require water in the groove to facilitate a
short to ground. In dry conditions a loop with nicked insulation may still
read good. Is your reading significantly lower with water in the groove?
In Summary:
It is important to remember that only one of the megohmmeters clip leads will
be connected to the loop, the other must be connected to ground.
We know that it is not very intuitive since you have 2 leads from the megohmmeter and 2 lead-in wires on the loop, many installers will put both leads to the loop. If an installer does connect both of the megohmmeter leads to the loop the megohmmeter will incorrectly show that the loop is bad or failing. (Go ahead and test it yourself, It won’t damage the loop.)
We also recommend using our BD Loops E-Z Detector Checker to help trouble
shoot the loop detector and circuit board. If you need additional assistance
with using this megohmmeter or testing loops please give us a call:
714-723-0946.
Protect Your Loop Installations
Protect your installations and track the health of your inductance loop
installations with the included Megohmmeter Testing Record Booklet. Need
more booklets? Download and print more Meghommeter Testing Record Booklets
on theBDLoops.com “Downloads” Page.|
---|---
Use Inductance Loop Warning Signs when you are installing a loop in a
concrete pour, or any application where other contractors will be working near
the loop. We know how often concrete companies damage inductance loops,
protect yourself and urge others to work carefully around the loops.
Inductance Loop Warning Signs can be downloaded and printed on the
BDLoops.com “Downloads” Page.|
Use the right loop sealant – Many installers don’t realize how important
using the right sealant is for increasing the life of saw-cut loops.|
---|---
BD-LS Features at a Glance:
- VOC Compliant
- Fast Skin & Cure time
- Use in All Climates
- Apply to Wet / Damp Substrates
- Tolerates Water Before Curing
- 100% Solids will now Shrink
- Resisting Yellowing
- Proposition 65 Compliant
- Paintable
- Available in Black & Gray
- Excellent UV Resistance
- Wide Adhesion Range
- Long-Term Durability
- Made in USA
BD Loops | 1907 Nancita Cir | Placentia, CA 92870
P:714-723-0946 | F:
714-890-1603 | E:
team@BDLoops.com |
www.BDLoops.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>