SKYWATCH SW-02 Multifunction Measuring Instrument Instruction Manual
- June 1, 2024
- SKYWATCH
Table of Contents
- GETTING STARTED
- MAIN FEATURES
- FUNCTIONS OF THE CENTRAL BUTTON
- CUSTOMISE YOUR SKYWATCH EXPERIENCE
- SHUTDOWN MODE
- DEFAULT DISPLAY
- MAINTENANCE
- NON-LIABILITY NOTICE
- TECHNICAL DETAILS
- DEFAULT PAGES CONTENT
- CLOCK SETTINGS
- COMPASS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INSTRUCTIONS FOR USE
GETTING STARTED
Thank you for purchasing this multifunction measuring instrument, designed and
manufactured in Switzerland. For accurate measurements, please read the
instructions and follow the precautions for use.
This instrument is designed to help users who find themselves outdoors, it
informs you about the conditions in your environment in real time. However, it
does not make weather forecasts and cannot replace the advice and warnings of
the local weather station.
Weather conditions outside can sometimes change very quickly.
Sunny weather, for example, can turn into a thunderstorm in half an hour or
less. So, you should always observe basic safety rules when undertaking any
outdoor activity.
MAIN FEATURES
SWITCHING ON
To switch on the instrument, briefly press the central button.
It displays the software version, then the last page read before switching off
(or the first page when using the SKYWATCH® Pro for the first time).
THE PAGES ARE ORGANISED BY DEFAULT, BUT CAN BE CUSTOMISED.
FUNCTIONS OF THE CENTRAL BUTTON
The central button allows different actions to be taken on the instrument
depending on how long it is pressed.
Press briefly → Switch the instrument on and off
Press for 1 second → Modify a value
Press for 2 seconds → Modify page content
Press for 3 seconds → Deactivate automatic switch off
Press for 4 seconds → Shut down the instrument
More than 4 seconds → Exit the menu
CUSTOMISE YOUR SKYWATCH EXPERIENCE
The SKYWATCH® Pro gives users the option of choosing the functions they wish
to display. They can choose between different units for a type of measurement,
as well as which type of measurement they want to appear on which page, and
modify certain values.
Set a value
(Press the central button for 1 second)
When this function is selected from the central button, a cursor appears on
the first modifiable value on the page. This selection frame can be moved
using the buttons to the left and right of the central button.
Press the central button to select the function whose value you want to
change, then use the side buttons to increase or decrease the value you want
to set. If there is no adjustable value on this page, the “set value” function
will be ignored.
Modifying the content of a setup page
(Press the central button for 2 seconds)
The user can modify each of the 3 areas of the screen. Each value and each
unit of measurement can be selected for each section of the screen.
When the “setup” function is selected, a cursor appears on the first section
visible on the screen. The cursor can be moved using the side buttons and the
central button is used to select the chosen value.
The right-hand button is used to change the unit of measurement, while the
left-hand button is used to change the type of measurement.
Pressing the central button confirms the new setting.
SWITCHING OFF
Auto-off
The SKYWATCH® Pro automatically switches off one minute after the last button
has been pressed or after the last wind measurement has been taken.
Manual switch-off
To manually deactivate the SKYWATCH® Pro, simply press the central button
briefly to turn off the device.
Deactivate automatic switch-off
Pressing the central button for 3 seconds deactivates the automatic switch-off
of the instrument.
Deactivating the automatic switch-off of the instrument means that the
instrument will remain switched on until the central button is pressed or
until the battery is empty.
SHUTDOWN MODE
If the device will be not used for a long period of time, battery depletion
can be minimized by switching the unit off completely.
Please note that this function also turns off the clock, which will need to be
reset when the instrument is switched on.
To maximize the life expectancy of the battery during a long storage period,
it is more efficient for the unit to be fully charged before it is switched
off. A fully charged battery before the unit is shut down gives a storage time
of around 2 years in this mode.
DEFAULT DISPLAY
A short press on one of the side buttons allows you to move from one page to
another.
Functions on default pages
8 pages are accessible on the instrument. The default contents when the
SKYWATCH ® Pro is switched on are as follows: (See details in default page
content)
Page 1: Real-time, maximum and average wind speed.
Page 2: Wind speed, wind direction angle (compass degrees and graph).
Page 3: Wind speed, temperature, perceived temperature.
Page 4: Temperature, humidity, dew point.
Page 5: Local pressure, sea level pressure, altitude above sea level.
Page 6: Local pressure, pressure at reference level, height above reference
level.
Page 7: Altitude above sea level, variometer (altitude variation).
Page 8: Time, date, year.
Key symbols
BATTERY
Your SKYWATCH® Pro is powered by a 230 mAh lithium battery. This battery can
be recharged using a QI induction charger. It takes an estimated 1.5 hours to
fully recharge the SKYWATCH® Pro.
PLEASE RECYCLE the instrument correctly, in accordance with current
regulations, when it reaches the end of its life.
MAINTENANCE
- Great care has been taken in the design and manufacture of this instrument. To make the most of the functions offered, we recommend that you use the instrument in accordance with the following instructions:
- Avoid at all costs the intrusion of objects such as hair, threads, sand and other dust inside the propeller, as this will cause the propeller to rotate incorrectly and thus result in a loss of precision. If a hair or thread does manage to get inside the propeller, remove it carefully with tweezers; if it is dust or sand, you can run the propeller under clear water.
- Avoid touching the temperature/humidity sensor.
- The instrument does not float and is not designed to be immersed in water.
- If the instrument has been immersed in water or subjected to excessive humidity, the humidity sensor may need time in a dry place before working properly again.
- Avoid exposing the instrument to extreme weather conditions for too long. Although it uses components that are resistant to these temperatures, we recommend that you do not expose your instrument to strong sources of heat, such as under the windscreen of a car, for example.
- Avoid rough handling or shocks.
DO NOT expose the instrument to strong chemicals. These products could damage the instrument.
NON-LIABILITY NOTICE
JDC ELECTRONIC SA cannot be held responsible for any consequences, direct or indirect, and for any damage that may result from the use of this equipment.
TECHNICAL DETAILS
Measurement units
Wind speed | km/h – m/s – knots – mph – fps – Beaufort |
---|---|
Temperature | °C –°F |
Humidity | %Hr |
Barometric pressure | hPa – inch Hg – mmHg |
Altitude | m – ft – Flight Level |
Variometer | m/s – ft/s |
Measurement range
Wind speed | 0 to 185 km/h |
---|---|
Temperature | -40°C to +70°C |
Humidity | 10 to 100% Hr |
Barometric pressure | 260 hPa – 1260 hPa |
Altitude | -500 to 9999m |
Precision
Wind speed | ± 2% |
---|---|
Temperature | ± 0.3°C at 25°C |
Humidity | ± 2% at 50% rH |
Barometric pressure | ± 0.02% at 25°C ± 0.2 hPa at 25°C |
Clock | Drift of ±1 s per day at 20°C |
Display resolution
Wind speed | 0.1 unit < 99.9 then 1 unit > 100 |
---|---|
Temperature | 0.1° < 99.9°, then 1° > 100°. |
Humidity | 0.1% rH |
Altitude | 0.1m from -999.9m to 3 000m 0.5m from 3000m to 10 000m |
Barometric pressure | 0.1 hPa – 0.01 in Hg – 0.075 mmHg |
Variometer | 0.1 units |
Temperature of use
Easy-to-read | +70°C to -10°C |
---|---|
Possible reading | -10°C to -20°C |
Display very slow but instrument functional (Sensors working correctly) | -20°C |
to -40°C
DEFAULT PAGES CONTENT
NON-ADJUSTABLE MODES :
Non-adjustable default pages for Set mode Value (modify values) :
LATERAL CONTROL BUTTONS :
- The button allows you to go down
- The buton moves up
List of non-adjustable values:
- Wind speed (instantaneous, average)
- Temperature (average, felt)
- Dew point
- Variometer
- Humidity
- Local pressure
MODE SETTINGS:
Modify a value (Set Value):
- Press the central button until “Set Value” appears at the top of the screen to change the value of a function.
- Use the side buttons to move the cursor to select the function to be modified, then press the central button to confirm your choice.
- Use these side buttons to adjust the selected value, then press to confirm the changes you have made.
Modifying the organization of the page (Setup):
- Press the central button until “Setup” appears at the top of the screen to change the type of measurement displayed at a location.
- Move the cursor using the side buttons to select the location of the function to be modified, press the central button to confirm your choice
- Use the left-hand button to change the type of function to be displayed, and the right-hand button to change the unit displayed.
- Press to confirm your changes.
CLOCK SETTINGS
- Go to page 8 of your SKYWATCH® Pro if the functions have not been moved. If you have already personalized the functions of your SKYWATCH® Pro, go to the location where you have placed the time, date and year functions.
- Press the central button until “Set Value” appears at the top of the screen to change the date, time or year.
- Move the cursor using the side buttons to select the line to be modified, then press the central button to confirm your choice.
- Use the side buttons to adjust the selected value, then press to confirm the changes you have made.
TEMPERATURE
SPECIFICITY:
The SKYWATCH® Pro provides a precise measurement of the temperature felt in
different weather conditions:
- Cold environment: Wind chill display (see illustration 1 below).
- Temperate environment: Displays the perceived temperature (see illustration no. 2 below).
- Hot environment: Heat stress is displayed (see illustration n°3 below).
COMPASS
Calibration:
The compass can be used in two ways:
- Horizontal calibration: Use the compass as you would a conventional compass.
- Vertical calibration: Position the propeller axis parallel to the ground.
To calibrate the instrument, follow these steps:
Switch on the instrument > Go to page 2 > press and hold until “Set Value” is
displayed, then choose one of the functions shown with or > the screen will
display the type of calibration required (vertical or horizontal). To
calibrate the vertical compass of the anemometer, hold the SKYWATCH® Pro with
the axis of the propeller parallel to the ground. Rotate the instrument a few
times, taking care to avoid moving the point outside the circle, then press
the central button to record the calibration measurement.
To calibrate the horizontal compass of the anemometer, hold the SKYWATCH® Pro
with the axis of the propeller perpendicular to the ground. Rotate the
instrument a few times, taking care to avoid moving the point outside the
circle, then press the central button to record the calibration measurement.
If your calibration
measurement is insufficient or incorrect, the screen may display the image
shown on the left. This indicates that your measurement contained too many
errors and that you need to repeat the procedure.
How to use it:
-
Vertical use:
Place the SKYWATCH® Pro facing into the wind, ensuring that the axis of the propeller is parallel to the ground. Once calibrated, a value will be displayed correctly when you hold the anemometer correctly.
Optimum use is when the inclination of the propeller axis is straight to within ± 10°. Although measurements up to ±20° are possible, the accuracy decreases.
For best results, keep the axis parallel to the ground. -
Horizontal use:
Position your SKYWATCH® Pro horizontally, like a conventional compass. If the screen displays three dashes or , the anemometer is not in the correct position. In this case, orientate it so that the axis of the propeller is perpendicular to the ground; once correctly oriented, the angle will be displayed.
If you regularly use the compass function in a vertical position, we strongly recommend that you use the carbon vane wind vane sold with this product to give the anemometer greater stability and more accurate measurements. The wind vane can be fixed to a tripod to refine your measurements.
BATTERY DISPLAY
Flat battery
Battery on
charge JDC ELECTRONIC
SA
Avenue des Sports 42
1400 Yverdon-Les-Bains Switzerland
info@jdc.ch www.jdc.ch
IMPORTANT INFORMATION ABOUT RECYCLING THE PRODUCT
The product, its packaging and the battery supplied are made from valuable
materials that can be recycled.
Recycling reduces the amount of waste and helps to preserve the environment
Take the packaging to a recycling point that sorts materials by type. Use
local facilities for collecting paper, cardboard and light packaging by type.
Appliances marked with this symbol must not be disposed of with household
waste! You are legally obliged to dispose of old appliances separately from
household waste.
Information on collection points where old appliances can be disposed of free
of charge is available from your local authority.
©JDC Electronic SA, all rights reserved.
V 1.0 Mars 2024
References
- JDC Electronic SA - Electronic development - Yverdon - Switzerland
- JDC Electronic SA - Electronic development - Yverdon - Switzerland
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>