SUNCO LIGHTING Industrial Shop Light Installation Guide
- June 3, 2024
- Sunco Lighting
Table of Contents
Industrial Shop Light
The Brighter Choice
INDUSTRIAL SHOP LIGHT
Install Guide and Manual
COMPONENTS
X2 Chain Link
60″ Flat Power Cord
X2 “S” Hook
X2 Screw Eye Hook
X4 Plastic Anchor
X2 Screw
X1 Zip Tie
EASY INSTALLATION Suspension Install
Turn Power OFF
1. Turn off circuit breaker that provides power to the
tlioghthteswligithcthsfwoirtcthhefoLrEDthSehLoEpDLSighhotp. Light.
2. Mounting surface must be able to support the weight
tohfethweefigixhtturoef.the fixture. · Plaster board – #8 eye hook screw with
plastic anchors, or aenxcphaonrssi,oonrbeoxlptsan(nsoiotninbcolultdse(dn)o; t
included); · Plaster board thickness should be 3/8 inch. · Open frame wood
joists. -#8 eye hooks only, no anchors nreoqaunircehdo. rs required.
Connect to Power Outlet
Connect to additional shop light
Link up 4 shop lights
together
5. Space the anchors to suit your lighting plan and power cord length. · Link up to 4
46.83″ apart
Min. 3/8″ thick
Required Tools: Drill, Ladder, Hammer, Pliers, Tape Measure, Pencil.
3. Drill pilot holes. Spacing between hooks should be 46.83 inches apart. ·
Dry Wall = 7/32″ drill bit · Wall Stud = 9/64″ drill bit
4. Insert x2 wall anchors, then screw in the screw eye hooks into the
anchors.
6. Install one S hook into each end of the chain. · Repeat with second chain.
· Crimp to secure to chain. Leave other side open
7. Loop S hook into the fixture’s end keyhole slot. · Repeat with second
chain. · Crimp end to secure.
8. Loop the supplied cable tie through one chain link and around the power cord to secure it to the chain. This is necessary prior to hanging.
9. Hang the lose end of the S hook chain on
screw eye hook in ceiling.
Turn Power
· Repeat with second chain.
ON 10. Plug in power cord to electrical outlet.
11. Turn on circuit breaker and test light.
WARNING
To reduce the risk of fire, electric shock or injury to people: · This product
should be installed in accordance with the applicable installation code
by a person familiar with the construction and operation of the product and
the hazards involved. ·Do not alter, relocate or remove wiring (plug) during
installation. ·Proper grounding is required to ensure safety. Do not install
directly over a heat source. ·Check for damage during shipping prior to
install. If the product is damaged, do not use it. ·This fixture complies Part
15 of the FCC rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. ·Not to use with dimmers. ·Do not use the plug on the
side of the LED Shop Light as an outlet for appliances, vacuums, power tools,
extension cables, etc. This was designed for daisy chain only. Using it for
other purposes will void your warranty. ·Turn off the switch and circuit
breaker before installing this LED light fixture. When using the wall switch,
make sure the pull chain is on. ·Use safety precautions. Safety eyeglasses and
gloves are recommended. ·Please review instructions carefully before
proceeding.
SPECIFICATIONS
Voltage Wattage Suitable for Locations Ingress Housing Weight Warranty
120V 40W Damp Aluminum + PC 1.47lbs 7 years
The Brighter Choice
INDUSTRIAL SHOP LIGHT
Install Guide and Manual
COMPONENTS
X2 Chain Link
60″ Flat Power Cord
X2 “S” Hook
X2 Screw Eye Hook
X4 Plastic Anchor
X2 Screw
X1 Zip Tie
EASY INSTALLATION Direct Mount Installation
Turn Power OFF
1. Turn off circuit breaker that provides power to the light switch for the
LED Shop Light.
2. Mounting surface must be able to support the weight of the fixture. ·
Plasterboard thickness should be 3/8 inch. · Open frame wood joists. -#8 eye
hooks.
46.36″ apart
Connect to Power Outlet
Connect to additional shop light
Link up 4 shop lights
together
5. Space the anchors to suit your lighting plan and power cord length. · Link up to 4
0.28″ 0.17″
Required Tools: Drill, Ladder, Hammer, Pliers, Tape Measure, Pencil.
3. Drill pilot holes. Spacing between hooks should be 46.36 inches apart. ·
Dry Wall = 7/32″ drill bit · Wall Stud = 9/64″ drill bit
4. Insert x2 wall anchors, then screws. · Leave approximately 1/4″ of the
screw exposed · Leave about 0.17″ gap between the screw head and mounting
surface
6. Lift fixture up to screws and slide to one side to secure into place.
Screw should be in narrow portion of keyhole. Tighten screws so fixture is
firmly fixed against screws.
7. Plug in power cord to electrical outlet.
8. Turn on circuit breaker and test light.
WARNING
To reduce the risk of fire, electric shock or injury to people: · This product
should be installed in accordance with the applicable installation code
by a person familiar with the construction and operation of the product and
the hazards involved. ·Do not alter, relocate or remove wiring (plug) during
installation. ·Proper grounding is required to ensure safety. Do not install
directly over a heat source. ·Check for damage during shipping prior to
install. If the product is damaged, do not use it. ·This fixture complies Part
15 of the FCC rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. ·Not to use with dimmers. ·Do not use the plug on the
side of the LED Shop Light as an outlet for appliances, vacuums, power tools,
extension cables, etc. This was designed for daisy chain only. Using it for
other purposes will void your warranty. ·Turn off the switch and circuit
breaker before installing this LED light fixture. When using the wall switch,
make sure the pull chain is on. ·Use safety precautions. Safety eyeglasses and
gloves are recommended. ·Please review instructions carefully before
proceeding.
Turn Power ON
SPECIFICATIONS
Voltage Wattage Suitable for Locations Ingress Housing Weight Warranty
120V 40W Damp Aluminum + PC 1.47lbs 7 years
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>