SOLAS BI-48-ST Built In Direct Vent Gas Fireplaces User Manual Product Information

June 1, 2024
Solas

BI-48-ST Built In Direct Vent Gas Fireplaces

Product Information

Specifications

  • Product Name: Cool Zone
  • Compatibility: Built-in direct vent gas fireplaces
  • Models: See-Thru Models – BI-48-ST, BI-60-ST, BI-72-ST; Single
    Side Models – BI-48-SSL, BI-48-SSR, BI-60-SSL, BI-60-SSR,
    BI-72-SSL, BI-72-SSR (Units manufactured with Serial Number 8467
    and higher)

Product Usage Instructions

Safety Warnings:

– Do not store or use gasoline or other flammable vapors and
liquids near the appliance.
– If you smell gas, take immediate action and contact a qualified
installer.
– Installation and service must be performed by
professionals.
– Keep the appliance away from furniture, draperies, and high
traffic areas due to high temperatures.
– Supervise children around the appliance to prevent burns or
clothing ignition.
– Do not place flammable materials near the appliance.

Installation and Maintenance:

– Improper installation or maintenance can cause injury or
damage. Refer to the manual for guidance.
– Ensure the cool wall plenum outlet is not obstructed and is out
of reach.
– Prevent dust or particles in the cool zone airflow to avoid
staining on light-colored surfaces.

Installation Record:

The installer should maintain a record of installation details
including date purchased, dealer information, date installed,
fireplace model, burner type, serial number, brand of venting used,
and model number of vent cap used.

FAQ

Is this product suitable for all gas types?

No, this appliance is designed for use with the type of gas
indicated on the rating plate and is not convertible for use with
other gases without a certified kit.

How can I prevent staining on ceilings or walls?

Ensure there is a significant distance between the outlet and
the ceiling to mitigate dust or particle staining issues.

What should I do if I smell gas?

If you detect a gas odor, take immediate action by following the
safety guidelines provided and contacting a qualified installer or
service agency.

COOL ZONE
FOR USE WITH BUILT IN DIRECT VENT GAS FIREPLACES

SUPPLEMENTAL INSTALLATION MANUAL
SEE-THRU MODELS: BI-48-ST, BI-60-ST, BI-72-ST SINGLE SIDE MODELS: BI-48-SSL, BI-48-SSR, BI-60-SSL, BI-60-SSR, BI-72-SSL, BI-72-SSR
*Units Manufactured with Serial Number 8467 and higher.

WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
· If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARD OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE.
DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
WARNING Improper installation, adjustment, services or maintenance can cause injury, or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.

Report #F19-219
Ce manual est disponsible en Francais sur demande. This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING
DO NOT cover or place objects in front of the cool wall plenum outlet. DISCHARGE TEMPERATURES ARE HOT! Locate outlet plenum out of reach and away from high traffic areas.
WARNING
Dust or particles caught in the cool zone airflow may cause staining or streaking on light colored ceilings or walls when exiting the plenum outlet. Keeping as large a distance as possible between the outlet and the ceiling will mitigate this issue.

INSTALLER: Leave this manual with appliancesol|asCfirOesN.coSmUMER: Retain this manual for future reference 1

INSTALLATION RECORD

The installer should complete the form below that describes the details of the installation. Having this written record of installation information available will greatly expedite troubleshooting should any problem arise with your stove. The installer should keep a duplicate of this form for their records.

Date Purchased: _____

Dealer: _____

Date Installed: ___

Installer: ____

Fireplace Model: (circle one) FORTY8 SIXTY0 SEVENTY2

Burner: (circle one) Glass Media Burner Log Set Burner

Serial Number: ___

Brand of Venting Used: ____

Model # of Vent Cap Used: _____

Fuel: (circle one) Natural Gas (NG) Propane (LP)

Was this field converted? (circle one)

YES NO

Inlet Pressure (after installation):


Manifold Pressure (after Installation): High Fire: _____ in. WC

Low Fire: __ in. WC

Altitude: (feet above sea level) ___

Was the Fireplace derated? (circle one)

YES NO

If the Fireplace was derated, to what orifice size?


Other installation notes: ____




2

SÓLAS CONTEMPORARY FIRE

CONTENTS

Installation Record …………………………………………………….2 Important Safety Information…………………………………….5 Model Descriptions……………………………………………………7 Certification……………………………………………………………… 10 Specifications …………………………………………………………… 11 Clearances to Combustibles ………………………………….. 12 Installation Information …………………………………………… 14 Installation ……………………………………………………………….. 15 Warranty Information………………………………………………20

NOTE: 2×4 Steel Studs and Foil Tape are required materials for Installation. (Not inluded in the Cool Zone Kit)
NOTE: DO NOT SCREW INTO THE FACE OF THE FIREPLACE.
NOTE: Prior to enclosing the wall cavity, test fire the fireplace to ensure it is fully operational.

WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BEGINNING THE INSTALLATION OF THIS DIRECT VENT GAS FIREPLACE. ALTHOUGH THE BASIC REQUIREMENTS FOR THE INSTALLATION OF ALL DIRECT VENT GAS FIREPLACES ARE SIMILAR, EACH SPECIFIC PRODUCT HAS ITS OWN UNIQUE SET-UP AND INSTALLATION REQUIREMENTS THAT MUST BE FOLLOWED EXACTLY. PLAN YOUR INSTALLATION IN ADVANCE BY CAREFULLY REVIEWING ALL THE INFORMATION CONTAINED IN THIS MANUAL.

Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of improperly installed or maintained venting system could result in serious injury, property damage, or loss of life.
This Installation Guide must be followed in its entirty and with out modification.

The information contained in this manual is believed to be correct at the time of printing. SÓLAS LLC reserves the right to change or modify any information or specifications without notice. SÓLAS LLC grants no warranty, implied or stated, for the installation or maintenance of your appliance, and assumes no responsibility for any consequential damage(s). © 2023 Copyright SÓLAS LLC.

solasfires.com

3

Félicitations pour votre achat d’un SÓLAS !
Nous vous souhaitons la bienvenue dans la famille des foyers au gaz SÓLAS. Chacun de nos produits est habilement conçu et fabriqué de manière experte aux États-Unis. Nous sommes très fiers de chaque foyer que nous fabriquons. Chaque produit est entièrement testé tout au long du processus de production pour garantir votre sécurité et votre chaleur au fil des ans.
Sincèrement, SÓLAS

AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduir e au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquids inflammables dans le voisinage de cet ap pareil ou de tout autre appareil. — QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ: · Ne pas tenter d’allumer d’appareil. · Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment où vous trouvez. · Appelez immédiatem ent votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. · Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
— L’installation et l’entretien doivent être assurés par un installateur ou un s ervice d’entretien qualifié ou par le fournisseur de gaz.

Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilesée.
Ne pas utilieser cet appareils il a été plongé, meme partiellement, dans l’eau. Appeler un technician qualifié pour inspecter l’appareail et remplacer toute partie du système de commande et toute commande qui a été plongée dans / ‘eau.
ATTENTION: Au moment de l’entretien des commandes, étiquetez tous les files avant de les débrancher. Des erreurs de la câblage peuvent entraîner un fonctionnement inadequate et dangereux.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
ATTENTION: Ne pas utiliser l’appareil si la panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technician agree.

INSTALLATEUR: LAISSEZ CE MANUEL AVEC L’APPAREIL. CONSOMMATEUR: CONSERVEZ CE MANUEL AUX FINS DE CONSULTATION ULTÉRIEURE.

4

SÓLAS CONTEMPORARY FIRE

IMPORTANT SAFETY INFORMATION

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/BCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of / psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than / psi (3.5 kPa).

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at- risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces.

The installation must provide for adequate ventilation air to the appliance.
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22. 1.
The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

The flow of combustion and ventilation air must not be obstructed. Adequate accessibility clearances must be maintained for servicing and proper operation of this appliance.

solasfires.com

5

IMPORTANT SAFETY INFORMATION
Fireplace
Keep Furniture and Other Objects 36″ from Fireplace
36″ (91.44cm)

Installation and repair should be done by a licensed service technician. The appliance should be inspected before use and at least annually by a professional service technician. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean. Warranty void if not.

WARNING: Do not operate the appliance with the glass door assembly removed, or if the glass is cracked or broken. Replacement of the glass should be done by a qualified service technician.
WARNING: Use only glass assembly, P/N 48-510 for FORTY8, P/N 60-510 for SIXTY0, P/N 72-510 for SEVENTY2, which includes the glass panel, frame and gasket. Do not use substitute materials. Do not strike or slam the glass front. Do not use abrasive cleaners. Do not clean when hot.

CAUTION: Do not operate with broken glass.

6

SÓLAS CONTEMPORARY FIRE

FORTY8 SEE-THRU
MODEL NO. BI-48-ST

MODEL DESCRIPTIONS
FORTY8 Models
FORTY8 SINGLE SIDE (Left side vent exit)
MODEL NO. BI-48-SSL

FORTY8 SINGLE SIDE (Right side vent exit)
MODEL NO. BI-48-SSR

(See-Thru Model can be installed with Left or Right Vent)
SIXTY0 SEE-THRU
MODEL NO. BI-60-ST

SIXTY0 Models
SIXTY0 SINGLE SIDE (Left side vent exit)
MODEL NO. BI-60-SSL

SIXTY0 SINGLE SIDE (Right side vent exit)
MODEL NO. BI-60-SSR

(See-Thru Model can be installed with Left or Right Vent)

SEVENTY2 SEE-THRU
MODEL NO. BI-72-ST

SEVENTY2 Models
SEVENTY2 SINGLE SIDE (Left side vent exit)
MODEL NO. BI-72-SSL

SEVENTY2 SINGLE SIDE (Right side vent exit)
MODEL NO. BI-72-SSR

(See-Thru Model can be installed with Left or Right Vent)

solasfires.com

7

MODEL DESCRIPTIONS

COOL ZONE KIT CONTENTS

FIREPLACE MODEL #
BI 48 SSR FORTY8 SINGLE-SIDED RIGHT

KIT PART # CZK-48-SSR

ITEM DESCRIPTION
FORTY8 COLLECTOR FORTY8 RIGHT HEAT SHIELD FORTY8 RIGHT PLENUM COOL ZONE 5″ HOSE CLAMP FORTY8 VIEWING AREA TRIM FORTY8 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE

ITEM PART #
12516 12536 12644 12666 12643 12641 12634 XXXX

FIREPLACE MODEL #
BI 48 SSL FORTY8 SINGLE-SIDED LEFT

KIT PART # CZK-48-SSL

ITEM DESCRIPTION
FORTY8 COLLECTOR FORTY8 LEFT HEAT SHIELD FORTY8 LEFT PLENUM COOL ZONE 5″ HOSE CLAMP FORTY8 VIEWING AREA TRIM FORTY8 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE

ITEM PART #
12516 12533 12520 12666 12643 12641 12634 XXXX

FIREPLACE MODEL #
BI 48 ST FORTY8 SEE THRU

KIT PART # CZK-48-ST

ITEM DESCRIPTION
FORTY8 COLLECTOR FORTY8 RIGHT HEAT SHIELD FORTY8 LEFT HEAT SHIELD FORTY8 SEE THRU PLENUM COOL ZONE 5″ HOSE CLAMP FORTY8 VIEWING AREA TRIM FORTY8 PLENUM OUTLET TRIM** COOL ZONE 5″ FLEX PIPE*** UTILITY KNIFE

ITEM PART #
12516 12536 12533 12649 12666 12643 12641 12634 XXXX

FIREPLACE MODEL #
BI 60 SSR SIXTY0 SINGLE-SIDED RIGHT
FIREPLACE MODEL #
BI 60 SSL SIXTY0 SINGLE-SIDED LEFT

KIT PART # CZK-60-SSR KIT PART # CZK-60-SSL

ITEM DESCRIPTION
SIXTY0 COLLECTOR SIXTY0 RIGHT HEAT SHIELD SIXTY0 RIGHT PLENUM COOL ZONE 5″ HOSE CLAMP SIXTY0 VIEWING AREA TRIM SIXTY0 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE
ITEM DESCRIPTION
SIXTY0 COLLECTOR SIXTY0 LEFT HEAT SHIELD SIXTY0 LEFT PLENUM COOL ZONE 5″ HOSE CLAMP SIXTY0 VIEWING AREA TRIM SIXTY0 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE

ITEM PART #
12651 12537 12660 12666 12657 12659 12634 XXXX
ITEM PART #
12651 12534 12653 12666 12657 12659 12634 XXXX

ITEM QTY PER KIT
1 1 1 8 1 1 4 1
ITEM QTY PER KIT
1 1 1 8 1 1 4 1
ITEM QTY PER KIT
1 1 1 1 8 2 2 4 1
ITEM QTY PER KIT
1 1 1 12 1 1 6 1
ITEM QTY PER KIT
1 1 1 12 1 1 6 1

  • This part was installed on your fireplace from the factory. ** Plenum Outlet Trim is required and is available in Satin Black or White, must choose one. ***The 5″ Flex pipe required for this installation can be purchased from SOLAS or from a third-party supplier.
    Should you choose to purchase from a third-party supplier, the 5″ flex used must be 2-ply thick 3003 Aluminum liner.

8

SÓLAS CONTEMPORARY FIRE

MODEL DESCRIPTIONS

COOL ZONE KIT CONTENTS

FIREPLACE MODEL #
BI 60 ST SIXTY0 SEE THRU

KIT PART # CZK-60-ST

ITEM DESCRIPTION
SIXTY0 COLLECTOR SIXTY0 RIGHT HEAT SHIELD SIXTY0 LEFT HEAT SHIELD SIXTY0 SEE THRU PLENUM COOL ZONE 5″ HOSE CLAMP SIXTY0 VIEWING AREA TRIM SIXTY0 PLENUM OUTLET TRIM** COOL ZONE 5″ FLEX PIPE*** UTILITY KNIFE

ITEM PART #
12651 12537 12534 12665 12666 12657 12659 12634 XXXX

ITEM QTY PER KIT
1 1 1 1 12 2 2 6 1

FIREPLACE MODEL #
BI 72 SSR SEVENTY2 SINGLE-SIDED RIGHT
FIREPLACE MODEL #
BI 72 SSL SEVENTY2 SINGLE-SIDED LEFT
FIREPLACE MODEL #
BI 72 ST SEVENTY2 SEE THRU

KIT PART # CZK-72-SSR

ITEM DESCRIPTION

ITEM PART #

SEVENTY2 COLLECTOR SEVENTY2 RIGHT HEAT SHIELD SEVENTY2 RIGHT PLENUM COOL ZONE 5″ HOSE CLAMP SEVENTY2 VIEWING AREA TRIM SEVENTY2 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE

12526 12538 12636 12666 12532 12559 12634 XXXX

KIT PART # CZK-72-SSL

ITEM DESCRIPTION

ITEM PART #

SEVENTY2 COLLECTOR SEVENTY2 LEFT HEAT SHIELD SEVENTY2 LEFT PLENUM COOL ZONE 5″ HOSE CLAMP SEVENTY2 VIEWING AREA TRIM SEVENTY2 PLENUM OUTLET TRIM COOL ZONE 5″ FLEX PIPE UTILITY KNIFE

12526 12535 12527 12666 12532 12559 12634 XXXX

KIT PART # CZK-72-ST

ITEM DESCRIPTION

ITEM PART #

SEVENTY2 COLLECTOR SEVENTY2 RIGHT HEAT SHIELD SEVENTY2 LEFT HEAT SHIELD SEVENTY2 SEE THRU PLENUM COOL ZONE 5″ HOSE CLAMP SEVENTY2 VIEWING AREA TRIM SEVENTY2 PLENUM OUTLET TRIM** COOL ZONE 5″ FLEX PIPE*** UTILITY KNIFE

12526 12538 12535 12551 12666 12532 12559 12634 XXXX

ITEM QTY PER KIT
1 1 1 12 1 1 6 1
ITEM QTY PER KIT
1 1 1 12 1 1 6 1
ITEM QTY PER KIT
1 1 1 1 12 2 2 6 1

  • This part was installed on your fireplace from the factory. ** Plenum Outlet Trim is required and is available in Satin Black or White, must choose one. ***The 5″ Flex pipe required for this installation can be purchased from SOLAS or from a third-party supplier.
    Should you choose to purchase from a third-party supplier, the 5″ flex used must be 2-ply thick 3003 Aluminum liner.

For Replacement Parts and customer service, contact your SÓLAS Dealer or;
SÓLAS, LLC 452 Sunapee Street, Newport, NH 03773 P 603-298-5169 sales@solasfires.com

solasfires.com

9

Plenum Plenum Outlet Trim
5″ Flex Pipe

MODEL DESCRIPTIONS
2×4 Steel Studs
(not included with Cool Zone Kit)

Viewing Area Trim
· CZK-72-SSL shown on a BI-72-SSL, all models utilize the same basic cool zone design. All FORTY8 based models employ (4) 5″ flex pipes, SIXTY0 and SEVENTY2 fireplaces require (6) 5″ flex pipes.
· The plenum outlet trim must be on the same plane as the face of the fireplace

Collector
Cool Zone Heatshield is located behind the front face of the fireplace

Side View
Showing Plenum outlet on the same plane as the face of the fireplace

10

SÓLAS CONTEMPORARY FIRE

CERTIFICATION

This appliance has been certified by PFS TECO to ANSI Z21.882014/CSA 2.33-2014 Vented Gas Fireplace Heaters and CAN/ CGA-2.17-M91 (2014), Gas-Fired Appliances for Use At High Altitudes.
This SÓLAS Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an

elevation greater than those noted, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.
These appliances are approved for installation in the Commonwealth of Massachusetts by the Board of State Examiners of Plumbers and Gas Fitters.

SÓLAS DIRECT VENT GAS FIREPLACES

SÓLAS DIRECT VENT GAS FIREPLACES

*Rating Label (affixed to Control Panel within Firebox) 11

SPECIFICATIONS
L M

NOTE:

Clearances

below are only

applicable when

unit is installed

with a SÓLAS

Cool Zone Kit. For

clearances without

Cool Zone, refer

A

to the standard

product manual.

H

K

D E
J

F

COOL ZONE KIT DIMENSIONS

DIMENSION A (MIN A (MAX B C D E F G H (MIN H (MAX J K (MIN
K (MIN L M

DIMENSION DESCRIPTION Minimum Fireplace Cavity Height Maximum Fireplace Cavity Height Fireplace Cavity Width Fireplace Cavity Depth Glass Viewing Area Width Glass Viewing Area Height LH Side to Center of Viewing Area RH Side to Center of Viewing Area Minimum Steel Stud Length Maximum Steel Stud Length Floor to Centerline of Viewing Area Minimum Centerline of Viewing Area to Centerline of Cool Zone Plenum Outlet Maximum Centerline of Viewing Area to Centerline of Cool Zone Plenum Outlet Cool Zone Plenum Width Cool Zone Plenum Height

G B

FORTY8 61.50″ (1,562mm) 175.50″ (4,458mm) 64.00″ (1,626mm) 12.00″ (305mm) 50.50″ (1,283mm) 14.00″ (356mm) 35.13″ 28.88″ 30.00″ (762mm) 96.00″ (2,438mm) 14.38″ (365mm) 45.75″ (1,162mm)
111.75″ (2,838mm) 49.25″ (1,251mm) 2.63″ (66mm)

SIXTY0 61.50″ (1,562mm) 175.50″ (4,458mm) 74.00″ (1,880mm) 12.00″ (305mm) 60.50″ (1,537mm) 14.00″ (356mm) 40.63″ 33.38″ 30.00″ (762mm) 96.00″ (2,438mm) 14.38″ (365mm)
45.75″ (1,162mm)

SEVENTY2 61.50″ (1,562mm) 175.50″ (4,458mm) 88.00″ (2,235mm) 12.00″ (305mm) 74.50″ (1,892mm) 14.00″ (356mm) 48.25 39.75″ 30.00″ (762mm) 96.00″ (2,438mm) 14.38″ (365mm)
45.75″ (1,162mm)

111.75″ (2,838mm) 59.50″ (1,511mm) 2.63″ (66mm)

111.75″ (2,838mm) 73.25″ (1,861mm) 2.63″ (66mm)

12

SÓLAS CONTEMPORARY FIRE

CLEARANCE TO COMBUSTIBLES

A

C B

COOL ZONE COMBUSTIBLE STUD DIMENSIONS

DIMENSION A (MIN A (MAX B C

DIMENSION DESCRIPTION Minimum Fireplace Cavity Height Maximum Fireplace Cavity Height Fireplace Cavity Width Fireplace Cavity Depth

FORTY8 61.50″ (1,562mm) 175.50″ (4,458mm) 64.00″ (1,626mm) 12.00″ (305mm)

SIXTY0 61.50″ (1,562mm) 175.50″ (4,458mm) 74.00″ (1,880mm) 12.00″ (305mm)

SEVENTY2 61.50″ (1,562mm) 175.50″ (4,458mm) 88.00″ (2,235mm) 12.00″ (305mm)

· 1.50″ (38mm) clearance to combustibles is required around the outer diameter of the flue pipe.
· The floor the fireplace immediately rests on must be constructed of non- combustible material with an R factor of at least .37, with a minimum thickness of ½” (13mm).
· This framing guide is just an example of the many ways in which a SÓLAS Fireplace can be installed. You may need to customize this framing design to allow for things such as doors, windows, countertops, structural frame members or local code requirements.
· The sheet metal face of this fireplace must be covered by a finishing material, it may not be left exposed. Combustible finishing materials are permitted.
· All wiring or conduit must be a minimum of 12″ (308mm) from top of fireplace and 1.5″ (38mm) from Cool Zone Flex Pipe.

solasfires.com

13

CENTERING DIMENSIONS FOR COOL ZONE

Clearances to Combustibles: Top and Sides: 4″, Bottom: / ” Please note: Single sided models can be ordered with left or right side venting READ INSTALLATION MANUAL BEFORE INSTALLATION

Dimension “AA” “BB” “CC” “DD” “EE”
“FF”
“GG”

Dimension Description
Viewing Area Non-flue side spacing Flue side spacing Non-combustible requirement, side Distance required to center viewing area Distance required to center viewing area, including non-combustible requirement Minimum wall space required to center viewing area

FORTY8 49.25″ (1,251mm) 2.70″ (69mm) 11.30″ (287mm) 4.00″ (102mm) 35.93″ (913mm)
39.93″ (1,014mm)
71.85″ (1,825mm)

SIXTY0 59.25″ (1,505mm) 2.70″ (69mm) 11.30″ (287mm) 4.00″ (102mm) 40.93″ (1,040mm)

SEVENTY2 73.25″ (1,861mm) 2.70″ (69mm) 11.30″ (287mm) 4.00″ (102mm) 47.93″ (1,217mm)

44.93″ (1,141mm) 51.93″ (1,319mm)

81.85″ (2,079mm) 95.85″ (2,435mm)

14

SÓLAS CONTEMPORARY FIRE

CLEARANCE TO COMBUSTIBLES

3.00 (76mm) MINIMUM CLEARANCE
TO CEILING

12.00 (305MM) MAXIMUM

COMBUSTIBLE MANTEL

6.00 (152mm) MINIMUM FROM
BOTH WALLS

3.00 (78mm) MINIMUM

WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. Failure to do so could result in serious injury, property damage, or loss of life. Operation of improperly installed or maintained venting system could result in serious injury, property damage, or loss of life.

ATTENTION: Before proceeding with your installation, determine if you plan to use either the SelfCalibrating Power Vent Kit, Cool Zone Kit, or the Heat Redistribution Kit. Read the manual for these optional components before proceeding with your installation, as your installation requirements and procedure may change.

· The combustible area above the viewing area must not protrude more than ¾ (19mm) from the facing; if it does, it is considered a mantel and must meet the mantel requirements above.

solasfires.com

15

INSTALLATION INFORMATION
WARNING Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of improperly installed or maintained venting system could result in serious injury, property damage, or loss of life.
NOTE: Any electrical wiring, gas plumbing, or vent installation required by the appliance must be done prior to final finishing. The unit shall be test burned on high for at least 30 minutes prior to final finishing to confirm proper operation. Failure to test the appliance before final finishing may require significant and costly reconstruction .
INSTALLATION PRECAUTIONS: Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing the vent kit, the installer must read this fireplace manual and vent kit instructions. Only a qualified, licensed, installer/service person shall install the venting system. The installer must follow the following safety rules: · Wear gloves and safety glasses for protection. · Use extreme caution when using ladders or when on
rooftops. · Be aware of electrical wiring locations in walls and ceilings.
NOTICE: Failure to follow these instructions will void the warranty.

16

SÓLAS CONTEMPORARY FIRE

INSTALLATION
1. Move the fireplace into its final position, the surface the fireplace immediately rests on must be constructed of noncombustible material with an R factor of at least .37, with a minimum thickness of ½” (13mm). Remove the “Can Top Blanking Plate” by removing the #10 sheet metal screws using a / ” nut driver. You will need these #10 sheet metal screws in step #2.
Using the utility knife provided, cut out insulation that is now exposed. The insulation should be removed in the same size as the opening below the “Can Top Blanking Plate.” Cover newly exposed unfinished edge of insulation with foil tape provided with Cool Zone kit.

Can Top Blanking Plate

2. Install the “Collector” in place of the “Can Top Blanking Plate”, secure using the #10 screws saved from step #1.
3. Remove the back of the double-sided tape and affix viewing area trim around the fireplace viewing area.

Collector

solasfires.com

17

INSTALLATION
4. The 2×4 steel studs (not included) will be installed next. The stud length, dimensions “H” on page #10 can be calculated using either of the following equations:
English (inches): H = A ­ 31.375 Metric (millimeters): H = A – 797
*Refer to page 11 for dimensions “A” and “H” referenced in the above equations.
5. Once the studs have been cut to length, insert the studs fully in the collector stud brackets as shown in “Detail A” above, secure with (4) #10 self-drilling sheet metal screws per stud.

18

SÓLAS CONTEMPORARY FIRE

INSTALLATION
6. The 5″ diameter flex duct will now be installed. The duct length can be calculated using either of the following equations:
Duct Length Equation: English (inches): Duct Length = H ­ 23.75 Metric (millimeters): Duct Length = H ­ 603 *Refer to step 3 for dimension “H” referenced in the above equations.

7. Once the duct length has been calculated, stretch the ducts to the length calculated in step #5 and secure to the collector using the 5″ hose clamps provided.

solasfires.com

19

INSTALLATION INFORMATION

8. Install the plenum as shown below, the front studs will be inserted into the plenum stud brackets until they make contact with the plenum (as shown in “Detail B”). Secure the front studs to the plenum stud brackets using the (4)

10 self-drilling sheet metal screws per stud provided.

9. Once the front studs have been secured to the plenum, confirm that the plenum is level front to back and side to side. Once the plenum is level, secure the rear studs to the plenum stud brackets using the (4) #10 self- drilling sheet metal screws per stud provided.
10. Once the plenum has been installed, connect the ducts to the plenum and secure to the collector using the 5″ hose clamps provided.
11. Once the unit has been enclosed within the wall the “Plenum Outlet Trim” will be press fit into the plenum outlet opening. Apply some high temperature RTV/silicone during the installation of the “Plenum Outlet Trim” to insure it is secured in place.

NOTE: DO NOT SCREW INTO THE FACE OF THE FIREPLACE.
NOTE: Prior to enclosing the wall cavity, test fire the fireplace to ensure it is fully operational.

20

SÓLAS CONTEMPORARY FIRE

WARRANTY INFORMATION

THE WARRANTY
SÓLAS, LLC, a division of Progressive Manufacturing, Inc. (“SÓLAS”), Limited Lifetime Warranty warrants your SÓLAS brand gas fireplace (“Product”) to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty on workmanship defects causing loss of structural integrity. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only. After installation, if covered components manufactured by SÓLAS are found to be defective in material or workmanship during the Limited Lifetime Warranty period and while the Product remains at the site of the original installation, SÓLAS will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, SÓLAS will, at its option, refund the purchase price or wholesale price of the SÓLAS product, whichever is applicable. SÓLAS will also pay their prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components during the warranty period. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Lifetime Warranty as described herein.
COVERAGE COMMENCEMENT DATE Warranty coverage begins on the date of installation. The warranty shall commence no later than 24 months following the date of product shipment from SÓLAS, regardless of the installation date.
EXCLUSIONS AND LIMITATIONS This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of SÓLAS and proof of purchase must be provided. The Product body and firebox carry the Limited Lifetime Warranty. The following do not carry the Limited Lifetime Warranty, but are warranted as follows:
· Burner ­ Repair or replacement for three years from date of installation.
· Gas components & electrical components ­ Repair or replacement for one year from date of installation.
· Comfort Blowers & remote controls ­ Repair or replacement for one year from the date of installation.
· Porcelain Firebox Liners ­ Replacement for one year against cracking or breakage due to thermal stress from date of installation. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit.
· Gaskets ­ Repair or replacement for one year from the date of installation.
· Surrounds ­ Replacement for one year against cracking or breakage due to thermal stress. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit.
· Labor coverage ­ Prevailing SÓLAS rates apply for the warranty period of the component. SÓLAS will not be liable for travel costs for service work.
SÓLAS will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood, or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance. The Product must be subjected to normal use. The product is designed to burn either natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and could result in a fire hazard. (c) Damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise is normal and not a defect, and, therefore, not covered under warranty. The installer must ensure the appliance is burning as per the rating tag at the time of installation. Over-firing (operation above the listed BTU rate) of this appliance can cause serious damage and will nullify this warranty.
This warranty is void if:
a) The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.
b) The unit is subject to submersion in water or prolonged periods of dampness or condensation.
c) Any damage to the unit, combustion chamber, heat exchanger or other components due to water or weather damage which is the result of, but not limited to improper chimney/venting installation.

Damage to stainless steel, gold, nickel or porcelain enameled surfaces caused by fingerprints, scratches, melted items, or other external sources left on these surfaces from the use of cleaners is not covered in this warranty.
SÓLAS is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which may generate negative pressure in the room in which the appliance is installed. Additionally, SÓLAS assumes no responsibility for drafting conditions caused by venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall SÓLAS be responsible for materials, components, or construction, which are not manufactured or supplied by SÓLAS or for the labor necessary to install, repair, or remove such materials, components, or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking SÓLAS facility.
LIMITATION ON LIABILITY It is expressly agreed and understood that SÓLAS’ sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall SÓLAS be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is caused by SÓLAS’ negligence. SÓLAS has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness for a particular purpose.
SÓLAS makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for SÓLAS any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY SÓLAS reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by SÓLAS.
Contact SÓLAS at the address provided herein to obtain a listing of approved dealers/distributors. SÓLAS shall in no event be responsible for any warranty work done by a contractor that is not approved without first obtaining SÓLAS’ prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid, you must contact the SÓLAS dealer/distributor from which you purchased the product. If you cannot locate the dealer/distributor, then you must notify SÓLAS in writing. SÓLAS must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the SÓLAS Warranty Department. Visit our website at www.solasfires.com/ warranty.
SÓLAS, LLC
P 603-298-5169 F 603-298-9246
solasfires.com/warranty

solasfires.com

21

We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists. www.NFIcertified.org
RECORD YOUR PRODUCT INFORMATION
Model #: ____ Serial Number: __ D te Purch sed: __ Date Installed: ___
THANK YOU FOR CHOOSING
solasfires.com
V3/10.2023