SOLAS TWENTY6 Wall Mount Direct Vent Gas Fireplace Instruction Manual
- June 1, 2024
- Solas
Table of Contents
- SOLAS TWENTY6 Wall Mount Direct Vent Gas Fireplace
- Specifications
- Product Usage Instructions
- FAQs
- INSTALLATION RECORD
- IMPORTANT SAFETY INFORMATION
- INSTALLATION REQUIREMENTS
- ASSEMBLY & INSTALLATION
- LIGHTING & OPERATION
- SÓLAS ONE TOUCH REMOTE OPERATION
- ERROR CODE
- 27 PILOT ORIFICE #35 PILOT ORIFICE
- 55 LP BURNER ORIFICE 1PC
- 8 SCREW 1PC
- 5/64″ NG BURNER ORIFICE 1PC
- GAS CONVERSION
- MAINTENANCE
- 55 Burner Orifice (LP)
- 35 Pilot Orifice (NG)
- 27 Pilot Orifice (LP)
- WARRANTY INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SOLAS TWENTY6 Wall Mount Direct Vent Gas Fireplace
Specifications
- Product Name: TWENTY6 WALL MOUNT DIRECT VENT GAS FIREPLACE
- Models: ST-26N, ST-26P
- Gas Type: Natural Gas (NG) or Propane (LP)
- Installation: Wall Mount
Product Usage Instructions
Safety Warnings:
Failure to follow safety warnings could result in serious injury, death, or property damage. Follow these safety guidelines:
- Do not store or use gasoline or other flammable materials near the appliance.
- If you smell gas, take immediate action and contact a licensed installer or gas supplier.
- Keep the appliance away from furniture, draperies, and traffic areas due to high temperatures.
- Children and adults should be warned about high surface temperatures to avoid burns.
- Supervise young children when in the same room with the appliance.
- Avoid placing clothing or flammable materials near the appliance.
Installation Instructions:
Installation and service must be performed by a licensed installer, service agency, or gas supplier. Follow these steps:
- Choose a suitable location away from flammable materials.
- Ensure proper ventilation for gas combustion.
- Install the provided barrier for protection against hot glass.
- Record installation details for future reference and troubleshooting.
Maintenance:
Proper maintenance is essential for safety and optimal performance:
- Regularly check for gas leaks and proper ventilation.
- Clean the glass and surrounding area as needed.
- Inspect the burner and venting system for any obstructions.
- Follow the manufacturer’s guidelines for routine maintenance tasks.
FAQs
- Q: Can this gas fireplace be used with other gases?
- A: No, this appliance is only for use with the type of gas indicated on the rating plate.
- Q: What should I do if I smell gas?
- A: If you smell gas, take immediate action by contacting a licensed installer, service agency, or gas supplier.
TWENTY6
WALL MOUNT DIRECT VENT GAS FIREPLACE
INSTALLATION & OPERATION MANUAL
MODELS: ST-26N, ST-26P
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
· If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed installer, service
agency or the gas supplier.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARD OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM
WITH THE APPLIANCE.
DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
Report #F19-217
Ce manual est disponsible en Francais sur demande.
This appliance may be installed in an aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a
certified kit is used.
DANGER
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW
CHILDREN TO TOUCH GLASS.
WARNING Improper installation, adjustment, services or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a licensed installer, service agency or the gas supplier.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk individuals.
INSTALLER: Leave this manual with appliancesol|asCfirOesN.coSmUMER: Retain this manual for future reference 1
INSTALLATION RECORD
The installer should complete the form below that describes the details of the installation. Having this written record of installation information available will greatly expedite trouble-shooting should any problem arise with your stove. The installer should keep a duplicate of this form for their records.
Date Purchased: _____ Dealer:
Date Installed: ___
Installer: ____
Fireplace Model: TWENTY6
Burner: (circle one) Glass Media Burner Log Set Burner
Serial Number: ___
Brand of Venting Used: ____
Model # of Vent Cap Used: _____
Fuel: (circle one) Natural Gas (NG) Propane (LP)
Was this field converted? (circle one)
YES NO
Inlet Pressure (after installation):
Manifold Pressure (after Installation): High Fire: _____ in. WC
Low Fire: __ in. WC
Altitude: (feet above sea level) ___
Was the Fireplace derated? (circle one)
YES NO
If the Fireplace was derated, to what orifice size?
Other installation notes: ____
Congratulations on your purchase of a SÓLAS Fireplace!
We welcome you to the SÓLAS family of gas fireplaces. Each of our products are
skillfully designed and expertly manufactured in the USA. We take great pride
in every fireplace we make and each product is fully tested throughout the
production process to ensure your safety and warmth throughout the years.
Sincerely, The SÓLAS Team
WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BEGINNING THE
INSTALLATION OF THIS DIRECT-VENT GAS FIREPLACE. ALTHOUGH THE BASIC
REQUIREMENTS FOR THE INSTALLATION OF ALL DIRECT VENT GAS FIREPLACES ARE
SIMILAR, EACH SPECIFIC PRODUCT HAS ITS OWN UNIQUE SET-UP AND INSTALLATION
REQUIREMENTS THAT MUST BE FOLLOWED EXACTLY. PLAN YOUR INSTALLATION IN ADVANCE
BY CAREFULLY REVIEWING ALL THE INFORMATION CONTAINED IN THIS MANUAL.
The information contained in this manual is believed to be correct at the time
of printing. SÓLAS LLC. reserves the right to change or modify any information
or specifications without notice. SÓLAS LLC grants no warranty, implied or
stated, for the installation or maintenance of your appliance, and assumes no
responsibility for any consequential damage(s). © 2023 Copyright SÓLAS LLC.
AM PM
SÓLAS One-Touch Programmable Thermostatic Remote
(see page 41)
3
Félicitations pour votre achat d’un SÓLAS !
Nous vous souhaitons la bienvenue dans la famille des foyers au gaz SÓLAS.
Chacun de nos produits est habilement conçu et fabriqué de manière experte aux
États-Unis. Nous sommes très fiers de chaque foyer que nous fabriquons. Chaque
produit est entièrement testé tout au long du processus de production pour
garantir votre sécurité et votre chaleur au fil des ans.
Sincèrement, SÓLAS
AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette
notice pour réduir e au minimum le risque d’incendie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquids
inflammables dans le voisinage de cet ap pareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
· Ne pas tenter d’allumer d’appareil.
· Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se
trouvant dans le bâtiment où vous trouvez.
· Appelez immédiatem ent votre fournisseur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
· Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des
incendies.
— L’installation et l’entretien doivent être assurés par un installateur ou un
s ervice d’entretien qualifié ou par le fournisseur de gaz.
Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà
installée à demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur
la plaque signalétique. Cet appareil ne peut être converti à d’autres gaz,
sauf si une trousse de conversion est utilesée.
Ne pas utilieser cet appareils il a été plongé, meme partiellement, dans
l’eau. Appeler un technician qualifié pour inspecter l’appareail et remplacer
toute partie du système de commande et toute commande qui a été plongée dans /
‘eau.
ATTENTION: Au moment de l’entretien des commandes, étiquetez tous les files
avant de les débrancher. Des erreurs de la câblage peuvent entraîner un
fonctionnement inadequate et dangereux.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
ATTENTION: Ne pas utiliser l’appareil si la panneau frontal en verre n’est pas
en place, est craqué ou brisé. Confiez le remplacement du panneau à un
technician agree.
INSTALLATEUR: LAISSEZ CE MANUEL AVEC L’APPAREIL. CONSOMMATEUR: CONSERVEZ CE MANUEL AUX FINS DE CONSULTATION ULTÉRIEURE.
4
SÓLAS CONTEMPORARY FIRE
IMPORTANT SAFETY INFORMATION
ATTENTION: THIS FIREPLACE IS DESIGNED AS A WALL-MOUNTED PRODUCT, THIS FIREPLACE IS NOT TO BE “BUILT-IN” TO A WALL OR INSTALLED WITHIN A WALL CAVITY OR ALCOVE. THE INSTALLATION MUST COMPLY WITH THE CLEARANCES NOTED ON PAGE 9.
The flow of combustion and ventilation air must not be obstructed. Adequate
accessibility clearances must be maintained for servicing and proper operation
of this appliance.
Do not use this appliance if any part has been under water. Immediately call a
licensed service technician to inspect the appliance and to replace any part
of the control system and any gas control which has been under water.
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural
Gas and Propane Installation Code, CSA B149.1.
A manufactured home (USA only) or mobile home OEM installation must conform
with the Manufactured Home Construction and Safety Standard, Title 24 CFR,
Part 3280 or when such a standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/BCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The appliance and its appliance main gas valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of / psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing
its equipment shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than / psi (3.5 kPa).
The installation must provide for adequate ventilation air to the appliance.
This gas appliance must not be connected to a chimney flue serving a separate
solid-fuel burning appliance.
The appliance, when installed, must be electrically grounded in accordance
with local codes, or, in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22. 1.
The appliance area must be kept clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Due to high temperatures, the appliance should be located out of traffic and
away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room
as the appliance. Toddlers, young children and others may be susceptible to
accidental contact burns. A physical barrier is recommended if there are at-
risk individuals in the house. To restrict access to a fireplace or stove,
install an adjustable safety gate to keep toddlers, young children and other
at-risk individuals out of the room and away from hot surfaces.
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with this appliance and shall be installed for the protection of
children and other at-risk individuals. If the barrier becomes damaged, the
barrier shall be replaced with the manufacturer’s barrier for this appliance.
Clothing or other flammable material should not be placed on or near the
appliance.
Any screen or guard removed for servicing an appliance must be replaced prior
to operating the appliance.
solasfires.com
5
IMPORTANT SAFETY INFORMATION
6″
6″
Fireplace
Keep Furniture and Other Objects
6″ from sides and 36″ from front of Fireplace
36″ (91.44cm)
Installation and repair should be done by a licensed service technician. The appliance should be inspected before use and at least annually by a professional service technician. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean.
WARNING: Do not operate the appliance with the glass door assembly removed, or
if the glass is cracked or broken. Replacement of the glass should be done by
a licensed service technician.
WARNING: Use only glass assembly, P/N 26-510, which includes the glass panel,
frame and gasket. Do not use substitute materials. Do not strike or slam the
glass front. Do not use abrasive cleaners. Do not clean when hot.
CAUTION: Do not operate with broken glass.
6
SÓLAS CONTEMPORARY FIRE
CERTIFICATION
This appliance has been certified by PFS TECO to ANSI Z21.882016/CSA 2.33-2016
Vented Gas Fireplace Heaters and CAN/ CGA-2.17-2017, Gas-Fired Appliances for
Use At High Altitudes.
This SÓLAS Gas Fireplace is approved for installation at elevations up to 2000
feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your
installation is at an
SÓLAS DIRECT VENT GAS FIREPLACES
elevation greater than these, consult with the local authority having
jurisdiction for gas product installations to determine their specific
requirements for high altitude installations.
These appliances are approved for installation in the Commonwealth of
Massachusetts by the Board of State Examiners of Plumbers and Gas Fitters.
SÓLAS DIRECT VENT GAS FIREPLACES
*Sample Rating Label (affixed to Control Panel within Firebox)
7
SPECIFICATIONS
TWENTY6 SPECIFICATION CHART
INPUT Input Rating Min. Input Rating Orifice-DMS GAS SUPPLY Manifold Pressure High
NATURAL GAS 19,000 BTU/Hr. 11,000 BTU/Hr. 5/64″ NATURAL GAS 4.8″w.c. / 1.2kPa
Manifold Pressure Low
1.25″w.c. / 0.31kPa
Min. Supply Pressure
5.5″w.c. / 1.4kPa
Max. Supply Pressure EFFICIENCY NG / LP Maximum Observed Steady State Efficiency – % Steady State Efficiency – % Annual Fuel Utilization Efficiency (AFUE) – % Canadian p.4 Efficiency – %
10.0″w.c. / 2.5kPa NATURAL GAS 78.8 65.0 64.2 55.1
P R O PA N E 19,000 BTU/Hr. 11,000 BTU/Hr. #55 P R O PA N E 10.0″w.c. / 2.5kPa 4.2″w.c. / 1.1kPa 11.0″w.c. / 2.8kPa 13.0″w.c. / 3.3kPa PROPANE 79.5 61.4 60.5 50.0
NOTE: The maximum achievable steady state efficiency can vary depending on how
the fireplace is installed and operated.
· It is recommended that the pilot flame be turned off if the appliance will
not be in use for an extended period of time.
· This appliance is equipped for use with the fuel type indicated on the
rating plate. Field conversion is only permitted with a conversion kit
supplied by SÓLAS. See page 49 for gas conversion instructions.
This appliance has been certified by PFS TECO to ANSI Z21.88-2016/CSA
2.33-2016 Vented Gas Fireplace Heaters and CSA-2.17-2017, Gas-Fired Appliances
for Use At High Altitudes and CSA P.4.1-09. The is approved for installation
at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in
Canada without change. If your installation is at an elevation greater than
these, consult with the local authority having jurisdiction for gas product
installations to determine their specific requirements for
high altitude installations.
TWENTY6 OVERALL DIMENSIONS
8
SÓLAS CONTEMPORARY FIRE
CLEARANCES
Several issues must be addressed when selecting a suitable location for your TWENTY6 fireplace. The minimum clearances to combustible construction are listed below. In addition, access to the gas supply must be considered. The location of the fireplace will also affect the venting requirements and you must be certain the location will allow compliance with the venting requirements shown on page 11. You must also insure that your installation provides adequate accessibility clearance for servicing and proper operation.
Installation and repair should be done by a licensed service technician. The
appliance should be inspected before use and at least annually by a
professional service technician. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is imperative that
the control compartment, burners and circulating air passageways of the
appliance be kept clean.
NOTE: Alcove installation is not permissable.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
Fireplace Surround to L. Side Wall Fireplace Surround to R. Side Wall Fireplace Surround to Corner Wall Vent Pipe to Adjacent Materials Fireplace Surround to Ceiling Fireplace Surround to Rear Wall Fireplace Surround to Floor
6″ (152mm) 6″ (152mm) 6″ (152mm) 1.5″ (38mm) 8″ (203mm) 0″ (0mm)* 3″ (76mm)**
CEILING
C = 8″ 203mm C
FLOOR D
D = 3″ 76 mm
**The minimum required clearance to be maintained from the fireplace to combustible flooring is measured from the top surface of carpeting, tile, etc.
CORNER B = 6″ 152 mm
Shown with optional corner Kit)
WALLS A = 6″ 152 mm
A
A
MANTEL/SHELF F = 8″ 203 mm
F
AIR SPACE
E = / ” 9.5mm
Space behind the Mounting Plate)
E
*Mounting plate bosses contact the wall
B
B
solasfires.com
9
INSTALLATION REQUIREMENTS
STATE OF MASSACHUSETTS
The installation must be completed by a licensed plumber or gas fitter in the
Commonwealth of Massachusetts.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas fitter when
installed within the Commonwealth of Massachusetts. If this appliance is
installed in a dwelling, building or structure used in whole or in part for
residential purposes and the installation includes a horizontal vent
termination that is less than seven (7) feet above the finished grade in the
area of the venting, including but not limited to decks and porches, a
hardwired carbon monoxide detector with an alarm and battery back-up must be
installed on the floor level of the dwelling, building or structure where the
appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with
an alarm must be installed on each additional level of the dwelling, building
or structure served by the appliance. It shall be the responsibility of the
property owner to secure the services of licensed licensed professionals for
the installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is installed in a crawl
space or attic, the hardwired carbon monoxide detector with alarm and battery
back-up may be installed on the next adjacent floor level.
In the event that this requirement cannot be met at the time of completion of
the installation of the appliance, the owner shall have a period of thirty
(30) days to comply with the requirement. However, during said thirty (30) day
period, a battery operated carbon monoxide detector with alarm must be
installed.
Each carbon monoxide detector as required in accordance with the above
provisions must comply with NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition, when the vent termination is less than seven (7) feet above
finished grade a metal or plastic identification plate must be permanently
mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal. The sign shall
read, in print size no less than one-half ( / ) inch in size, “GAS VENT
DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
The gas fireplace is shipped with a / ” tube OD (male flare) connection. The
gas supply piping should have a separate gas shutoff valve and a / ” NPT
plugged tapping upstream of the valve. The stove and its main control valve
must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of / psi (3.5 kPa). The
stove must be isolated from the gas supply piping system by closing the main
control valve during any pressure testing of the gas supply system at test
pressures equal to or greater than / psi (3.5 kPa). After the gas supply has
been connected, use a commercial gas leak detector or apply a soapy water
solution to all the fittings to check for gas leaks. Never use a flame to test
for leaks.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH INCLUDE PARTS
LISTS, AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT
THE COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting system was used in the
installation. These instructions must remain with the SÓLAS Gas Fireplace
Installation & Operation Manual.
O Simpson DuraVent GS/PRO® O Selkirk Direct-Temp® O Security Secure VentTM O
AmeriVent DirectTM O Metal Fab Direct Vent O ICC Direct Vent
NOTICE Failure to follow these instructions will void the warranty.
10
SÓLAS CONTEMPORARY FIRE
VENTING
The SÓLAS TWENTY6 Direct-Vent Gas Fireplace has been tested and listed for
installation with 4″ X 6 5/8″ Simpson DuraVent GS/Pro®, Selkirk DirectTemp®,
Security Secure VentTM, AmeriVent DirectTM, Metal Fab DirectVent and ICC
EXCELDirect venting components. Although you may use the pipe components
(straight pipe, elbows, etc.) from any of the listed manufacturers, you may
only use the vent terminations (caps) listed in the chart on page 12. For
installations where a snorkel is needed, please note that only three snorkels
are approved for use. Please plan your installation accordingly.
For all specific venting installation requirements, follow the installation
instructions included by the venting manufacturer with the venting system
components you have chosen.
Please Note:
· For venting configurations that include no vertical rise, a total horizontal
equivalent vent run of up to 30 inches is allowed (when using a 45° elbow, 18
inches horizontal equivalent must be included). However, if your installation
has room to add a vertical pipe section, we suggest adding at least one foot
of vertical rise to the system.
· For venting configurations that include vertical rise, it is assumed that
the installation will include at least one 90° elbow. Up to three additional
90° elbows (or equivalent 45° elbows) may also be used. The total venting may
not exceed 20 feet of vertical rise and/or 10 feet horizontal run. Refer to
the venting charts starting on pages 13 & 14 for specific details while you
plan your installation. Note: The number of elbows impacts the maximum
allowable horizontal vent run.
· Many installations will involve venting directly through standard 2 X 4 or 2
X 6 construction exterior wall to a horizontal vent termination (cap). The
vent starter pipe has been designed to accommodate those two common
installations without the use of any additional venting components other than
a standard horizontal cap. See the chart on page 12 for a list of approved
vent caps.
· A special corner installation kit (Part Number CK-26-1) is also available
that will allow the TWENTY6 fireplace to be mounted in a corner without
constructing a 45° partition wall. This kit is available from your SÓLAS
dealer and has its own installation instructions. Please refer to those
instructions for specific details regarding the installation using the kit.
· If the fireplace will be installed on an interior wall or other location
that precludes venting directly through an outside wall to a horizontal vent
cap, or if the distance to the outside wall exceeds 30″, one or more elbows
will be required to allow addition of the required vertical venting to the
installation. When vertical venting is required, the fireplace venting may be
terminated with either a vertical or horizontal vent cap depending on the
specifics of the installation. Refer to the venting charts starting on pages
13 & 14 for specific venting requirements and see the chart on page 12 for a
list of approved vent caps before you plan your installation.
· There should be at least 1 / ” overlap of the vent and combustion air tubes,
when telescopic joints are used.
· A minimum clear space of 1 / ” must be maintained around the vent pipe where
it penetrates the first combustible wall adjacent to the fireplace (either the
outside wall for the direct-through-the-wall installation or the partition
wall for the 45° or other interior wall installations). The special vent pipe
heat shields that are provided with the TWENTY6 must also be installed in the
first wall adjacent to the fire-place. A minimum clear space of 1 / ” must
also be maintained where the vent pipe penetrates any other interior wall,
exterior wall, ceiling or roof.
· The TWENTY6 may also be installed in front of an existing fireplace opening
utilizing special co-linear venting components available from the venting
manufacturers. These systems split and then recombine the co-axial air and
exhaust and allow the use of flexible venting. This makes it easier to run the
venting through the narrow fireplace damper opening to the top of the chimney.
Refer to the vent manufacturers’ instructions. Use the vertical venting column
(0 feet Horizontal Run) in the venting charts to determine the required
restrictor settings depending on the height of chimney.
solasfires.com
11
VENTING
The location of the vent termination must meet the requirements of the current edition of ANSI Z223.1/NFPA 54, National Fuel Gas Code or CAN B419.1, Natural Gas and Propane Installation Code and the requirements shown on page 18 of this manual.
APPROVED VENT M&G DURAVENT SELKIRK
SECURITY
AMERIVENT METAL FAB ICC EXCEL
TERMINATIONS GS/PRO
DIRECT TEMP SECURE VENT DIRECT VENT DIRECT VENT DIRECT
VERTICAL CAP HORIZONTAL CAP SNORKEL
46DVAVCH
46DVAHC 46DVAHRCS 46DVAHSC
N/A
1604802 1604804 1604836
SV4CGC SV4GHC N/A
4DVC 4DHC 4D36C
4DVT 4DHT N/A
TM4VT
TM4HT TM4DHT
TMST36
Just as with any other vented device, vertical vent rise creates draft
(negative pressure) in the firebox as the exhaust gases heat up. If this draft
becomes excessive, it can affect the performance or appearance of the fire.
The TWENTY6 fireplace includes air and exhaust restrictors that are used to
balance the draft in the fireplace to the optimal level for installations
where excessive draft might occur. The venting charts on pages 13 and 14
provide an easy means for determining whether your specific installation
requires inlet air or exhaust restrictors or both. To make the determination
about whether air or exhaust restrictors are needed, a venting chart worksheet
is provided on page 15. Follow the instructions and fill in the worksheet for
your particular installation. This will allow you to determine the recommended
restrictor settings for your exact installation. Although this might appear to
be a complicated process at first glance, it is really quite straight-forward
and the result will be a fire that looks and performs as intended. Several
examples of worksheet calculations are shown on page 16 to help guide you.
Please be sure to note that:
1. There are separate venting charts for Natural Gas and LP Gas. Refer to the
appropriate chart for your fuel type to determine your specific restrictor
requirements. The settings in the charts have been determined based on
extensive testing.
2. Determine the total vertical vent rise and total horizontal vent run for
your installation. All measurements are made from the center of the vent
opening in the back of the fireplace.
3. If your fireplace will not be venting directly through an outside wall to
a horizontal termination or if more than 30″ of horizontal vent run is
required, some vertical vent rise will be required for the fireplace to
function and vent properly. Elbows will also be required for those
installations. However, installations are limited to a maximum of four 90°
elbows (or 45° elbow equivalents).
4. Note: Two 45° elbows equal one 90° elbow.
5. The recommended restrictor settings in the venting charts allow up to two
90° elbows (or 45° elbow equivalents) to be used without affecting the
restrictor settings. Additional elbows will require that you calculate a new
equivalent horizontal run for your installation to account for the additional
flow resistance caused by the extra elbows. For the purposes of calculating
the equivalent horizontal vent run, each additional 90° elbow is equivalent to
three feet of horizontal vent run and each additional 45° elbow is equivalent
to 1.5 feet of horizontal vent run. The total horizontal vent run including
elbow equivalents can not exceed 10 feet.
6. The maximum vertical vent rise can not exceed 20 feet.
7. There are two exhaust restrictors that are provided with your fireplace.
They are labeled “A” and “B”. The A restrictor provides less exhaust
restriction than B.
8. An air restrictor plate is also provided with your fireplace. It is a ring
with bendable tabs that can be set to adjust the amount of restriction in the
air supply system. Once the appropriate number tabs are bent open (in
accordance with the requirements for your installation), the plate is inserted
between the fireplace and the vent starter pipe.
SÓLAS Self-Calibrating Power Vent Option Available for all SÓLAS Wall-Mount DV
Models
Learn more @ solasfires.com
Power vent runs of up to 130ft with (8) 90 elbows are permitted when using the SOLAS Self-Calibrating Power Vent Kit. Refer to power vent instructions for additional power vent installation and operation information.
14
VENTING CHART WORKSHEET
VENTING WORKSHEET FOR INSTALLER
Use this worksheet to determine the equivalent horizontal run for use with the
vent charts on pages 13 and 14. The information contained within this
worksheet may also be useful during installation or in the event that you need
technical assistance from SÓLAS.
NOTE: Calculations for horizontal or vertical sections of pipe are measured
between transition joints as shown in the image below. Vent runs that are not
90° vertical are considered to have horizontal run but not a vertical rise.
NOTE: Snorkel terminations are counted as (2) 90° elbows.
A. TOTAL VERTICAL VENT RISE: Measured as total vertical distance between
flanges of elbows used in vent system. (See Diagram) Feet
B. TOTAL HORIZONTAL VENT RUN: Measured as total horizontal distance between
flanges of elbows used in vent system. (See Diagram) Feet
C. TOTAL NUMBER OF 90° ELBOWS in excess of 1: = “C” NOTE: Snorkel
terminations are counted as (2) 90° elbows
D. TOTAL NUMBER OF 45° ELBOWS in excess of 1: = “D”
E. 90 Elbow Horizontal Equivalent: C x 3 =
F. 45 Elbows Horizontal Equivalent: D x 1.5 =
G. Total Horizontal Equivalent: B + E + F = _____
Horizontal or vertical sections of pipe are measured between transition joints as shown in this image.
NOTE: Prior to enclosing the wall cavity, test fire the fireplace to ensure it is fully operational.
solasfires.com
15
VENTING EXAMPLES
EXAMPLE 1 TWENTY6
A. Total Vertical Vent Rise:
1__ feet
B. Total Horizontal Vent Run: 5__ feet
C. Total Number of 90° Elbows in excess of 1: 1__
(Snorkel terminations are counted as (2) 90° elbows)
D. Total Number of 45° Elbows in excess of 1: 0__ E. 90 Elbow
Horizontal Equivalent: C x 3 = 3 F. 45 Elbow Horizontal Equivalent: D x
1.5 = 0
G. Total Horizontal Equivalent: B + E + F = __8___
Side View
5 ft
1 ft
EXAMPLE 2 TWENTY6
A. Total Vertical Vent Rise:
0__ feet
B. Total Horizontal Vent Run: 2__ feet
C. Total Number of 90° Elbows in excess of 1: 0__
(Snorkel terminations are counted as (2) 90° elbows)
D. Total Number of 45° Elbows in excess of 1:0__ E. 90 Elbow
Horizontal Equivalent: C x 3 = __0___
F. 45 Elbow Horizontal Equivalent: D x 1.5 = 0 G. Total Horizontal Equivalent: B + E + F = 2
Side View
2 ft
EXAMPLE 3 TWENTY6
A. Total Vertical Vent Rise:
0__ feet
B. Total Horizontal Vent Run: 4__ feet
C. Total Number of 90° Elbows in excess of 1: 1__
(Snorkel terminations are counted as (2) 90° elbows)
D. Total Number of 45° Elbows in excess of 1: 0__ E. 90 Elbow
Horizontal Equivalent: C x 3 = 3 F. 45 Elbow Horizontal Equivalent: D x
1.5 = 0 G. Total Horizontal Equivalent: B + E + F = __7___
Side View
4 ft
This vent configuration is NOT ALLOWED. Refer to Vent Chart on pages 13 and
14.
16
SÓLAS CONTEMPORARY FIRE
VENTING
The illustration below shows some of the many ways the TWENTY6 fireplace may
be installed in the home. This includes interior and exterior wall
installations, corner installations and horizontal and vertical vent
terminations.
Horizontal
Vertical
Termination Termination
TWENTY6 Corner Kit Option
The optional TWENTY6 corner kit is a great
space saver. Corner Installation Kit CK-26-1
Power vent runs of up to 130ft with (8) 90 elbows are permitted when using the SOLAS Self-Calibrating Power Vent Kit. Refer to power vent instructions for additional power vent installation and operation information.
solasfires.com
17
VENTING
H
E F
M
S
S
R
P I
D G
D
D K
N L
U V
J
Covered Alcove Detail
2′
2′
17.5”
11.5”
Covered
Alcove Detail
Vinyl Siding
2′
2′
29.5”
17”
Must use Vinyl Siding Termination Shield
VENT TERMINAL LOCATIONS
CANADA*
U.S.A.**
A = Clearance to the termination frame above grade, veranda, porch, deck, or balcony 12″ (30 cm)
12″ (30 cm)
B = Clearance to top of doors or operable windows
12″ (30 cm)
12″ (30 cm)
C = Clearance to sides or bottom of door or operable windows
12″ (30 cm)
9″ (23 cm)
D = Clearance to permanently closed window, recommended to prevent
condensation E = Clearance to ventilated soffit located within a horizontal
distance to 24″ (61 cm)
from centerline of termination F = Clearance to unventilated soffit G =
Clearance to outside corner
16″ (41 cm) 22″ (56 cm) 30″ (76 cm) to combustibles 16″ (41 cm) to non- combustible 9″ (23 cm)
16″ (41 cm) 22″ (56 cm) 30″ (76 cm) to combustibles 16″ (41 cm) to non- combustible 9″ (23 cm)
H = Clearance to inside corner
12″ (30 cm)
12″ (30 cm)
I = Clearance to each side of the vertical centerline of a meter or regulatory assembly to a maximum vertical distance of 15ft (4.5m)
36″ (91 cm)
36″ (91 cm)
J = Clearance to service regulator vent outlet K = Clearance to non-mechanical
air supply inlet to the building or combustion air
inlet to other appliance for appliance <=100.000 BTU/H (30 KW) L = Clearance
to forced air supply inlet
36″ (91 cm) 12″ (30 cm) 72″ (183 cm)
36″ (91 cm) 12″ (30 cm) 36″ (91 cm) above air inlet
M = Clearance above paved sidewalk or paved driveway located on public property N = Clearance under veranda, porch, deck, or balcony P = Clearance above roof
84″ (213 cm) 22″ to combustibles 16″ to non-combustibles 24″ (61 cm)
84″ (213 cm) 22″ to combustibles 16″ to non-combustibles 24″ (61 cm)
Q = Clearance to adjacent walls and neighboring buildings
24″ (61 cm)
18″ (46 cm)
R = Clearance from corner in recessed location
12″ (30 cm)
12″ (30 cm)
S = Maximum depth of recessed location
48″ (122 cm)
48″ (122 cm)
T = Maximum width for back wall of recessed location
24″ (61 cm)
24″ (61 cm)
U = Horizontal clearance between two terminations that are level
0
0
V = Horizontal clearance (center to center) between two terminations that are not level 18″ (46 cm)
18″ (46 cm)
Note 1: For N a vent shall not terminate directly above the sidewalk or paved driveway which is located between two single-family dwellings and serve both dwellings. Note 2: For P only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. Note 3: For J, K, and as specified in CGA B149 installation co de. Local codes or regulations may vary. * Based on CGA B149.1 Natural Gas and Propane installation code. Local codes may vary, please check with local regulatory agency. ** Based on ANSI Z223.1/NFPA 54 National Fuel Gas Code. Local codes may vary, please check with local regulatory agency.
NOTICE: Venting terminations shall not be recessed into a wall or siding.
18
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
UNPACKING THE TWENTY6 WALL MOUNT FIREPLACE
The fireplace components are shipped in three cartons. By now, you will have
opened the top of the first carton, removed the glass protector and this
manual. The second carton contains the fireplace surround. The third carton
contains the vent starter pipe, vent heat shields and air and exhaust
restrictors.
1. Using the adjacent images as a guide, first lift and remove Box 1 from the
carton containing the firebox. Carefully unpack the contents of the tube and
set aside. This should include the bag of glass burner media, the remote
control handset, a hardware bag and relief doors with gasket.
2. Next lift and remove Box 2 from the carton. Carefully remove the contents
of the tube. This includes the Top & Bottom and Side Panels that will be
attached to the fireplace during assembly.
3. Next, remove all remaining packaging materials from the carton.
4. Lift the firebox and the fireplace mounting plate as a unit up and out of
the carton. The best place to lift is at sides. Remove the fireplace mounting
template from the face of the fireplace. You should now have all of the parts
as shown in the image below.
5. Next, unpack the vent starter pipe (with attached gasket), vent cap
insulation, the inner and outer pass-thru vent heat shields and the air and
exhaust restrictors from the second carton and set aside for later use.
6. Finally, unpack the fireplace surround from the third carton and set aside
on a soft surface for later use.
Box 2 Box 1
Box 1 Contents
Relief Doors
Remote
Remote Wall Bracket
Glass Media
Hardware
Box 2 Contents
Outer Side Outer Top &
Panels Bottom
Panels
Packing Material
Box 3 Contents
Inner & Outer PassThrough Heat Shields
Starter Pipe
Wall Template
Manual
Restrictors
solasfires.com
Gasket 19
ASSEMBLY & INSTALLATION
Before you begin the fireplace mounting process there are several important
installation requirements that must be met. Careful planning will make the
installation easier to accomplish and will reduce the chances of encountering
problems after you start.
Note: It is important to locate electrical wiring, plumbing, etc. in the wall
before beginning the installation process. An electrician or plumber should be
consulted if there is any question about wiring or plumbing locations. Failure
to locate and protect wiring or plumbing during the installation process may
result in electrical shock, gas leak, fire, and/or explosion which could cause
property loss and/or death.
1. The fireplace is designed to be wall-mounted using 4 lag bolts to secure
the fireplace mounting plate to the wall structure. The mounts are located 16″
on center and 24″ on center to correspond with standard building construction.
If your home has non-standard construction or the location you have chosen for
the fireplace does not have wall studs that correspond to location of the
fireplace mounts, modifications to the wall structure will be needed. It is
critical that the 4 lag bolts that are provided for mounting the fireplace are
firmly embedded into the wall structure at all four locations.
2. A hole must be provided in the wall for the vent to pass through. The hole
must be large enough to provide 1 / ” clearance around the outside of the vent
pipe and to allow for installation of the vent heat shields that are provided
with the fireplace. Follow the hole size requirements that are provided below
exactly to avoid problems. If the location you have chosen does not allow for
1 / ” clearance to wooden framing in the wall, modifications to the wall
structure must made to obtain the needed vent pipe clearance. Refer to the
Wall-Mount template on next page.
3. All required minimum clearances to adjacent combustible materials
(including side walls, ceiling and floor) must be achieved with the position
you have chosen. See the clearance information on page 9. The listed
clearances are measured from the outermost front edges of the fireplace
surround and not from the fireplace body or mounting plate. In addition the
requirements for clearance to combustible materials inside the house, there
are specific requirements and limitations that must be met for the location of
the vent terminal relative to doors, windows, corners, eaves, gas supply
components and other structural elements of the house. Please see page 18 for
those specific requirements. Again, plan the installation in advance to avoid
problems.
4. The gas supply line must be located within a specific area behind the
fireplace. Please see page 32.
20
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
LEVEL
15.3″
1.8″
7.0″ 3.2″
4.3″
Gas Supply
Opening
5.0″
(Choose One)
GAS SUPPLY CUTOUT
2.0″
VENT PASS THROUGH
Vent Hole 9.63″
For SL-26N & SL-26P Only
TWENTY6 Wall Template
For use with the following SÓLAS products: SL-26N, SL-26P, VF26-NG, VF26-LP,
OUT-26NG, OUT-26LP
The perimeter of this template corresponds with the surround profile, 38.8″ W
x 27.35″ H
Wall Mount Plate
34.6″ W x 25.0″ H
Drill Holes (8)
5/32″
24.0″
16.0″
MOUNTING HOLES
21.5″
TWENTY6 WALL TEMPLATE;12276, REV A
Once you are certain that the location you have chosen meets all the necessary
mounting and safety requirements, you can begin the installation.
1. Tape or pin the installation template to the wall in the position where
the fireplace is to be mounted. Note: It is important that the fireplace is
mounted in a level position. Use a level placed on the cross-hairs in the
upper mounting holes or the top line on the template and adjust the template
position until the mounting holes are level. Refer to the above illustration.
solasfires.com
21
ASSEMBLY & INSTALLATION
2. Next, carefully transfer the location of the two upper and two lower mounting holes that you will use for your installation. Use a sharp nail, awl or pin to pierce the template on the mounting hole cross-hairs to insure an accurate transfer to your wall.
4. Finally, transfer the location of the gas supply line.
Note: It is imperative to note the location of any plumbing or electrical
wiring in the wall before beginning the installation process. Consult a
plumber or an electrician if there is any doubt about the location of
utilities.
3. Next transfer the location for the center of the vent pass-through hole on
the wall. Also transfer other points on the diameter of the vent pass-through
circle. This will make it easier to cut the circle later.
22
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Vent Pass-Through (Parallel Wall Installation on an Outside Wall)
1. An unobstructed wall pass-through (9.63″ Vent Hole) is required to allow
for a safe installation of the fireplace vent components. This will
necessitate removal of a portion of the interior wall covering (e.g.,
sheetrock or plaster and lath), outer wall sheathing and outer wall covering
and any adjacent internal wall materials (like insulation).
2. Use a long pilot drill ( / ” diameter) that is held square and level to
the inside wall to transfer the vent passthrough center location from the
inner wall covering through to the outer wall sheathing and outer wall
covering.
3. Carefully cut the inner wall covering along the template line and remove
the circular wall piece.
Note: It is imperative to note the location of any plumbing or electrical
wiring in the wall before beginning the installation process. Consult a
plumber or an electrician if there is any doubt about the location of
utilities.
4. Carefully cut the gas supply opening, identified on the template.
5. Remove any insulation materials from wall in the area defined by the pass- through hole.
solasfires.com
23
ASSEMBLY & INSTALLATION
6. Building codes in your area may require that you add blocking above and
below the vent opening. The blocking should be above and below the 9 / ” vent
opening you made in the wall and should not obstruct that opening. The
blocking should extend to adjacent wall studs.
7. Next, mark and cut a 9 / ” diameter hole through the outer wall covering
and sheathing using the locating hole you drilled in Step 2.
8. Follow the instructions included with the vent termination (cap) to remove
the appropriate amount of outer wall covering (siding) or to install the vinyl
siding shield if used. Do not install the chimney cap at this point.
4. Carefully cut the inner wall covering along the scribed line and remove
the circular wall piece. Note: It is important to locate electrical wiring in
the wall before beginning the installation process. An electrician should be
consulted if there is any question about wiring locations. Failure to locate
and protect wiring during the installation process may result in electrical
shock or fire.
5. Remove any insulation materials from wall in the area defined by the pass-
through hole.
6. Building codes in your area may require that you add blocking above and
below the vent opening. The blocking should be above and below the 9 / ” vent
opening you made in the wall and should not obstruct that opening. The
blocking should extend to adjacent wall studs.
7. Next, mark and cut a 9 / ” diameter hole through the wall covering on the
back side of the partition wall using the locating hole you drilled in Step 2.
8. When installing the fireplace on a partition wall, the venting may be
penetrating one or more interior walls, an exterior wall, the ceiling or the
roof.
9. It is important to lay out the locations of all vent passthroughs before
you begin the installation to insure that the venting will line-up correctly
and that the walls and ceiling meet the needed clearances to the vent pipe.
10. The vent pass-through in the partition wall where the fireplace is
mounted must be done in accordance with the instructions for a parallel wall
installation on an outside wall, following steps 1 through 6.
Vent Pass-Through (Parallel Wall Installation on an Interior Partition Wall)
1. An unobstructed wall pass-through is required to allow for a safe
installation of the fireplace vent components. This will necessitate removal
of a portion of the interior wall covering (e.g., sheetrock or plaster and
lath), on both sides of the partition wall and any adjacent internal wall
materials (like insulation).
2. Scribe a 9 / ” diameter hole around the vent passthrough center mark using
a compass.
3. Use a long drill ( / ” diameter) that is held square and level to the
inside wall to transfer the vent passthrough center location from the inner
wall covering through to the wall covering on the back side of the partition
wall.
Vent Pipe (Pass-Through) Heat Shields
Special telescoping double heat shields for the vent pipe are provided with
the TWENTY6 fireplace. These heat shields are a critical part of a safe
installation. They are designed to protect combustible materials in the wall
immediately behind the fireplace. The only exception to this is if the corner
installation kit (Part Number CK-26-1) is used. With the corner kit, the heat
shields are installed where the venting passes through the first adjacent side
wall. See the instructions included with the corner kit for specific details.
24
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing the Fireplace Mounting Plate on the Wall
1. The fireplace mounting plate is attached to the wall structure using four
/ ” X 1 / ” long lag bolts and large diameter washers that are provided with
the fireplace. It is important to use the included hardware as the full weight
of the fireplace is supported by the mounting plate.
2. Drill a / ” diameter pilot hole at each of the mounting hole locations
that you marked using the template. The pilot holes should be the full depth
of the lag bolts. Be sure that there is solid wood at each mounting location.
If not, the wall should be reconstructed to provide the needed support.
4. The outer vent pipe heat shield half (larger diameter) is installed on the rear of the mounting plate. Slip the outer shield half over the inner shield and align and install the three screws. See photo below.
Outer Vent Pipe Shield
(Larger Diameter, install on the backside of the Mounting Plate)
3. Before the mounting plate can be lagged to the wall the two tabbed sections of the telescoping vent pipe heat shields that you set aside earlier must be attached to the mounting plate. Each heat shield half is held in place with three sheet metal screws (provided). The inner shield half (smaller diameter) is installed from the front of the mounting plate. Slide the inner heat shield half through the vent pipe opening in the mounting plate. Align the three tabs with the pilot holes in the mounting plate (as shown in the adjacent photo) and install the three screws.
5. The fireplace mounting plate is now ready to be lagged to the wall
structure.
6. With a helper pick up and align the mounting plate over the gas supply
line and line up with the four mounting lag bolt pilot holes. These holes are
recessed.
Mounting Plate Front
4 Lag Bolt Hole Locations
bosses. Use either the 16″ or 24″ on center holes depending on the construction of the wall.
Inner Vent Pipe Shield
(Smaller Diameter, install on the front of the Mounting Plate)
solasfires.com
25
ASSEMBLY & INSTALLATION
Installing the Fireplace Mounting Plate on the Wall (continued)
NOTE: It may be helpful to put a light coating of dish or hand soap on the lag
bolts to reduce resistance when tightening.
7. Using the lag bolts and washers provided with the fireplace, install the
top lag bolts (with washers) first, followed by the lower ones. Use a / ”
socket wrench to tighten the lag bolts.
10. The next step is to install the vent starter pipe onto the fireplace.
11. Remove the glass panel and glass frame assembly from the front of the
firebox by loosening and removing the four / ” bolts that are located along
the top edge of the glass frame.
12. While holding the glass panel and glass frame along the outer edges, tip the top of the glass frame forward a few inches.
When installing the second top lag bolt, ensure the mounting plate is level.
8. At this point, check to be sure that there is a / ” air gap between the
entire flat back surface of the mounting plate and the wall surface. The gap
is critical to a safe installation and if the gap is obstructed in any way,
remove the obstruction before proceeding.
9. Next check that the brackets on the mounting plate that hold the fireplace
are level, again using a level. If the brackets are not perfectly level, you
can adjust the right bracket by loosening the bracket fasteners and moving the
bracket until it is level with the left bracket. Remember to tighten the
bracket fasteners once you have achieved a level position.
13. Wrap your fingers around the frame and hold the glass and frame together while you lift the frame up and out of the lower glass retainer. Set the glass and frame assembly aside in a safe place.
Level Mounting Plate Brackets
Lower Glass Retainer
26
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing the Fireplace
14. Carefully place the fireplace with the front down on a protected floor.
15. At this point, it is necessary to determine whether your installation
will require the addition of flow restrictors to the combustion air inlet
system or the exhaust outlet or both. Refer to the venting section that starts
on page 11 to make that determination.
16. If your installation does not require any restrictors, place the vent
starter pipe gasket on the back of the fireplace aligning the holes in the
gasket with the pilot holes on the rear of the fireplace.
18. When the flange contacts the gasket, install the (4) #10, / ” fasteners provided with the starter pipe.
17. Align the inner pipe of the vent starter pipe with the exhaust outlet pipe on the fireplace. The vent pipe will fit tightly over the fireplace pipe. Gently push the starter pipe on to the fireplace pipe until the outer pipe flange makes contact with the starter pipe gasket. Be sure that the holes in the starter pipe flange align with the gasket and pilot holes.
Skip to step #25 on page 29 if your installation DOES NOT require Air
Restrictor or Exhaust Restrictor. (NOTE: Restrictors for use in vertical
venting installations only).
19. If your installation does require an air restrictor or exhaust restrictor
or both, (NOTE: Restrictors for use in vertical venting installations only)
these must be installed before you install the vent starter pipe. Again, refer
to the venting information starting on page 11 to determine the specific
restrictor requirements for your specific installation.
< Exhaust Restrictor
Air Restrictor >
Installing the Vent Starter Pipe & Gasket
solasfires.com
27
ASSEMBLY & INSTALLATION
Installing the Fireplace (con’t)
20. Place the vent starter pipe gasket on the back of the fireplace aligning the holes in the gasket with the pilot holes on the rear of the fireplace.
22. If the air restrictor ring is required, first determine the number of tabs that must be bent open. Before bending any tabs, align the mounting holes in the ring over the four pilot holes on the back of the fireplace. When selecting the tabs to bend, it is important to maintain the most symmetrical pattern possible. The first tabs bent must be opposite each other and oriented horizontally. If only one tab is specified, orient the ring over the pilot holes so the split tabs are oriented horizontally and bend up two opposing half-tabs. Additional tabs should be evenly spaced relative to the first two. With the appropriate tabs bent, re-align the mounting holes in over the pilot holes keeping the proper orientation AND with the bent tabs facing away from the fireplace body.
21. The exhaust restrictor is installed by placing it through the exhaust outlet pipe and resting it on the internal baffle in the firebox. It is held in place with a movable retainer clip. Simply hold the restrictor down against the baffle and push the retainer up and tighten screw to secure the restrictor. Note: Please take care to insure that the exhaust restrictor is centered in the exhaust outlet. Improper alignment could adversely affect the appearance of the flames. Refer to the adjacent images for placement of the exhaust restrictor and clip.
Air Restrictor ring shown with 3 tabs open
23. Align the inner pipe of the vent starter pipe with the exhaust outlet pipe on the fireplace. The vent pipe will fit tightly over the fireplace pipe. Gently push the starter pipe on to the fire-place pipe until the outer pipe flange makes contact with the vent pipe gasket. Be sure that the holes in the starter pipe flange align with the gasket and pilot holes. When the flange contacts the gasket, install the four fasteners provided with the starter pipe.
Installing the Vent Starter Pipe & Gasket
28
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing the Fireplace (con’t)
24. When the flange contacts the gasket, install the (4) #10, / ” fasteners
provided with the starter pipe.
26. While looking in from the sides, guide the upper and lower mounting tabs on the back of the fireplace into the corresponding brackets on the mounting plate. When the tabs and brackets are aligned, push the fireplace down and in to engage the tabs in the brackets. Note: The weight of the fireplace is carried only on the top brackets. The bottom brackets function simply to keep the bottom of the fireplace from moving. Refer to the photo below.
25. You are now ready to install the fireplace on the mounting plate. This will require a helper as the fireplace is quite heavy. Lift the fireplace up and guide the vent pipe into the vent pipe opening in the mounting plate. The vent pipe must be at the highest location possible in the vent pipe opening (almost touching the inner vent pipe heat shield) to allow the mounting tabs on the rear of the fireplace to clear the top of the mounting brackets on the mounting plate.
27. If the fireplace is properly positioned on the brackets the vent starter
pipe and vent heat shields should be concentric when viewed through the vent
pass-through in the wall. Go outside and look in the hole to confirm this. If
you are mounting the fireplace on a partition wall, look in the pass-through
using a mirror if needed. If the vent starter pipe and vent pipe heat shields
do not appear to be concentric, check to be sure that the mounting tabs on the
fireplace are all fully engaged in the brackets on the mounting plate and that
the upper two tabs are sitting down on the upper brackets. If they are not,
adjust the fireplace until they are.
28. The image below is a view before installing Vent Termination Cap.
4 Mounting Plate Brackets
solasfires.com
29
ASSEMBLY & INSTALLATION
Installing the Outer Vent Heat Shields and Vent Termination (Horizontal
Installation on Outside Wall)
1. Before you install the horizontal vent termination, you must first install
the second halves of the two telescoping vent pipe heat shields. Each shield
half simply slips over the half you previously attached to the fireplace
mounting plate and can now be seen inside the vent pass-through in the wall.
2. Install the outer shield first and the inner second. Leave at least 2″ of
the shields protruding past the house sheathing.
5. Slide the vent termination (cap) into the siding recess (or vinyl siding shield) until it bottoms out. Note: The rear surface of the vent termination will push the telescoping vent pipe heat shields inward. When the vent termination is in place the heat shields will just touch the rear surface of the termination.
3. Install the horizontal vent termination (vent cap). Be sure the arrow on
the cap (if present) is pointing up and reconfirm that all the vent cap
location requirements per page 18 and the vent manufacturers requirements are
met.
4. Slip the inner and outer vent termination pipes onto the vent starter pipe
taking care to align the inner and outer pipes to prevent damage.
6. Pull the vent cap away from the sheathing and install a small bead of non-
hardening silicone sealer around the cap perimeter. Push the cap in place.
7. Install the mounting screws (included with the cap) to hold the vent cap
to the sheathing See the venting manufacturers instructions for the location
of the mounting holes. Typical mounting hole locations are shown in the
adjacent photo. See the venting manufacturers instructions for more
information or if using the vinyl siding shield.
Mounting Holes
30
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing the Outer Vent Heat Shields (Partition Wall Installation)
1. Before you install the additional vent pipe and elbow(s) that will
complete the venting installation, you must first install the second sections
of the vent pipe heat shields to protect the combustible materials around the
vent pipe pass-through in the partition wall that the fireplace is mounted on.
Each shield half simply slips over the half you previously attached to the
fireplace mounting plate and that can now be seen inside the vent passthrough
in the partition wall.
2. Install the outer shield first and the inner second. Leave at least 2″ of
both shields protruding past the partition wall framing or wall covering. See
photo to right
Vent Pipe Installation (Partition Wall Installation)
3. The specific details of the vent configuration from the vent starter pipe
on the fireplace to the horizontal or vertical vent termination (cap) when the
fireplace is installed on an interior wall of the house will vary depending on
the location of the fireplace on the wall, what is on the back side of the
wall, where the vent termination will be located (roof or exterior wall) and
on other code requirements for the location of the vent termination as shown
page 18. However, the maximum vent length, measured along the centerline of
the pipe, from the back of the fireplace to the start of the vent termination
cannot exceed 30 feet, including a maximum of 20 feet of vertical rise and a
maximum of 10 feet of horizontal run. If more than two 90° elbows (or
equivalent 45° elbows) are needed for your installation, the maximum amount of
horizontal run allowed is reduced. See the venting section starting on page 11
for specific information. It is important to plan the installation in advance
so that you can accurately locate any wall or ceiling pass-throughs and the
vent termination on the exterior wall or roof. The vent pipe sections are
available only in certain increments of length and in adjustable length
sections. Plan carefully before you start!
4. You will find it helpful to leave access to the area behind the partition
wall to facilitate installation of the vent components. The pipe sections may
have twist lock connections which will be difficult to execute without good
access.
5. Be sure that the two vent pipe heat shields extend at least 2″ beyond the
rear side of the partition wall adjacent to the fireplace after the venting is
installed.
6. Maintain a minimum 1 / ” unobstructed air space around the vent pipe where
it passes through other interior walls, the ceiling, the exterior wall or the
roof.
Note: Vent manufacturer’s instructions and some building codes may require the
addition of blocking above and below all wall pass-throughs, the addition of
vent manufacturer supplied fire-stops, wall thimbles, attic insulation
shields, interior trim collars, vent support brackets, or other components.
Please check with the authority having jurisdiction in your area when planning
the venting installation to determine the specific code requirements and exact
venting components that are required for your installation.
solasfires.com
31
ASSEMBLY & INSTALLATION
Gas Supply Line
Once the vent pass-through (or pass-throughs) are finished, the gas supply
line should be installed. The supply line should exit the wall that the
fireplace will be installed on at the location specified on the installation
template We suggest the installation of a shut-off valve in the supply line
between the wall and the connection to the fireplace. Your professional gas
installer or local gas company will determine the specific requirements for
the gas supply line as the requirements may vary in different locations. In
every case, the installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian
Installation Code, CAN/CGA B149.
Gas Shut-Off
Gas Connection
1. Verify that the gas type is correct for the fireplace by looking at the
rating plate that is attached to the right side of the fireplace, adjacent to
the control battery pack. Note: The fireplace is shipped from the factory
equipped to burn the fuel listed on the rating plate. Conversion kit
information and instructions are available on page 49.
2. The gas connection should now be made from the gas supply line to the
inlet on the fireplace. Use only a licensed gas installer to make the
connection.
3. The fireplace is shipped from the factory with a / ” tube OD (male) flare
connection.
4. The gas supply piping should have a separate gas shut-off valve and a / ”
NPT plugged tapping upstream of the valve. We recommend installing a shut-off
valve between the gas supply line where it penetrates the wall / fireplace
mounting plate and the inlet to the regulator on the fireplace. This will
allow gas to be shut-off to the fireplace by simply removing the fireplace
sur-round to gain access to the shut-off valve.
NOTE: The fireplace and its main burner valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of / psi (3.5kPa).
NOTE: The fireplace must be isolated from the gas supply piping system by
closing the gas shut-off valve during any pressure testing of the gas supply
system at test pressures equal to or less than / psi (3.5kPa). After the gas
supply has been connected, use a commercial gas leak detector or apply a soapy
water solution to all the fittings to check for gas leaks. Never use a flame
to test for leaks.
32
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing or Replacing the Batteries
1. The valve control module is powered by (4) “AA” batteries. The batteries
are mounted within the Valve Receiver Module located on the right side of the
fireplace attached to a drop-down mounting bracket for easy accessibility.
Refer to the adjacent photo.
2. Loosen the thumb screw on the module drop-down mounting bracket by turning
counter-clockwise until the threads are fully disengaged from the base
bracket.
3. Rotate the Valve Receiver Module and mounting bracket. Toward you 90°.
4. Slide off the Battery compartment cover.
5. Install the (4) “AA” batteries, supplied, using the guides inside the
battery pack to show you the correct battery orientation.
6. Replace the battery compartment cover. Rotate the Valve Receiver Module
and mounting bracket into its home position and tighten the thumb screw to
secure.
7. The remote handset is powered by (2) “AAA” batteries. The access panel is
located on the back of the handset and simply snaps open to provide access to
the battery compartment. Install the three batteries as shown on the label
inside the remote control battery compartment.
8. Replace the remote handset access panel.
Placing the Burner Glass Media
SÓLAS Fireplaces come standard with a Glass Media Burner. If you have the
optional SÓLAS Log Set/Log Set Burner, please refer to the separate Log Set
Installation Manual for instructions.
The burner glass media poly bag that you set aside when you unpacked the
fireplace contains the correct amount of glass material to cover the burner.
The entire contents of the bag should be evenly distributed over the burner
tray.
1. Locate the burner in the fireplace. Refer to the adjacent photo.
2. Carefully clip one corner of the poly bag to form a pouring spout. The
opening should be large enough to allow the glass media to flow but not so
large that you can’t control the flow.
3. You will notice that the burner surface is designed with turned-up edges
that form a tray to hold the glass media.
Burner Tray
solasfires.com
33
ASSEMBLY & INSTALLATION
Placing the Burner Glass Media (continued)
4. Starting at one end, pour the glass media onto the burner tray, keeping
the pouring spout on the poly bag toward the center of the burner to avoid
spillage of glass pieces over the sides of the burner. See the adjacent
photos.
5. Once you have poured all of the glass burner media into the burner tray,
carefully smooth the glass pieces out so they have a uniform depth over the
entire surface of the burner. When the burner glass media is properly placed,
it should look like the adjacent photos.
6. NOTE: If a few pieces of glass escape over the edges of the burner tray
during installation, it is not a problem. They will simply land in the area
below the burner and will do no harm.
Burner Glass Media partially installed
Relief Door Installation
1. The top relief doors (2) are shipped separate from the fireplace and must
be installed on the top of the firebox at this point in the installation.
NOTE: The relief doors include a gasket that covers the full bottom surface.
Use care in handling the relief door to avoid damage to the gasket material.
2. The first image shows the relief openings and relief door retainers.
3. Each relief door includes line-up tabs that correspond to slotted
retainers on the firebox.
4. Tip the relief door enough to allow the rear line-up tab to engage the
rear retainer slot. Refer to the second image.
5. Rotate the front edge of each relief door so they lineup over front
retainers.
6. Gently spring the front forward so it will allow the relief door front
line-up tab to engage on the retainer. Refer to the first image on the top of
the next page.
7. The relief door should be able to move up and down freely on the retainers
if properly installed.
8. When the relief door installation is complete, the door should be in the
full down position. Refer to the second image on the top of the next page.
Burner Glass Media fully installed Retainers
Relief Openings
Relief Door Front Tab
Relief Door Rear Tab Engaged with Rear Retainer
34
SÓLAS CONTEMPORARY FIRE
Relief Door Installation (con’t)
ASSEMBLY & INSTALLATION
Relief Door front tab engaged on retainers
Relief Door shown in proper operating position
Installing the Front Glass Panel and Frame
After burner media and relief doors have been installed, the next step is to
replace the front glass panel and frame.
1. Carefully pick up the glass and glass frame assembly by grasping the sides
of the frame and using your thumbs and fingers to hold the glass in place
within the gasket and frame.
2. With the glass frame (and glass) held at a slight angle (leaving room for
your fingers between the frame and the firebox) insert the bottom edge of the
frame into the frame retainer located on the bottom front of the firebox. Take
care to center the frame from left to right.
4. Hold the frame in place with one hand and insert the four glass frame
fasteners along the top edge of the glass frame. Tighten the fasteners until
they are hand-tight.
5. Tighten each fastener / turn at a time, working from one side to the
other, until the glass frame has made contact with the firebox face along the
entire top edge. Do not over-tighten the fasteners as this can put excessive
stress on the glass.
3. Once the bottom edge is in place, move your fingers out of the way and press the top of the frame against the firebox while pushing down to be sure the frame is fully engaged in the frame retainer.
NOTE: Fireplace must not be used without relief doors installed. Relief door openings must be covered by relief doors, and the relief doors must be able to slide freely on the retainers.
solasfires.com
35
ASSEMBLY & INSTALLATION
Installing the Outer Panels
The outer top and bottom panels are secured to the fireplace mounting plate
with sheet metal screws. All other screws are philips head machine screws.
1. Install the outer top panel first. Align the three holes along the rear
edge of the panel with pilot holes along the top edge of the fireplace
mounting plate. Insert and tighten the three sheet metal screws. A magnetic
nut driver is helpful.
3. Locate the fastener hole at the top front edge of the outer left side panel and align with the PEM nut in the front of the top panel. Insert the philips head screw.
2. Install the outer left side panel next. Align the three holes along the rear edge of the panel with the PEM nuts along the edge of the fireplace mounting plate. Insert the three philips head screws but do not fully tighten.
4. Make sure the edges of the panel are aligned with the edges of the top
outer panel and mounting plate and tighten all four philips head screws.
5. Position the outer right side panel so it aligns with the three PEM nuts
on the mounting plate and the front PEM nut on the top panel. Align the rear
and outer top panel edges with the adjoining parts and insert and tighten the
four philips head screws.
6. Install the outer bottom panel next. Guide the rear flange on the panel
upward until the mounting holes in the flange line up with the pilot holes in
the mounting plate.
7. Attach the panel to the mounting plate using sheet metal screws along the back edge of the panel. Note: It may make installation of the sheet metal screws easier if you remove the two lower surround mounting brackets from the front of the fireplace. A magnetic nut-driver will also be helpful.
36
SÓLAS CONTEMPORARY FIRE
ASSEMBLY & INSTALLATION
Installing the Outer Panels (con’t)
8. Attach the outer bottom panel to the outer side panels by aligning the
fastener holes in the bottom panel with the PEM nuts in the front corners of
the bottom flanges on the outer side panels. Insert and tighten the two
philips head screws.
Installing the Fireplace Surround with Integrated Screen
The decorative surround with integrated screen for the fireplace is held in
place by four brackets. Two are located on the top of the fireplace and two on
the bottom. There are mating brackets and catch plates on the surround itself.
Refer to the adjacent photos when installing the surround.
1. Unpack the surround with integrated screen from shipping box.
2. With a helper, lift the surround with integrated screen up and identify
the top by looking for the vertical brackets that are visible from the rear of
the surround.
Back of Surround (top) Vertical Brackets
Note: Only trim kit(s) supplied by the manufacturer shall be used in the
installation of this appliance.
3. Move the surround with integrated screen into place, generally centering
the surround opening over the glass panel. Keep the bottom of the surround
tipped slightly away from the fireplace.
solasfires.com
37
ASSEMBLY & INSTALLATION
4. While looking behind the surround with integrated screen, guide the two surround brackets onto the forward detent of the mating brackets on the fireplace top. You might find it easier to engage one bracket and then the other. Lower the surround until both bracket sets are fully mated.
6. Carefully swing the bottom of the surround with integrated screen toward the base of the fireplace until each of the L brackets on the surround are aligned with the magnets on the fireplace, holding the bottom of the surround securely on the fireplace.
Forward Detent
Rear Detent
Magnet
5. Carefully push the top of the surround with integrated screen so that the surround brackets slide into the rear detent of the mating brackets on the fireplace top.
7. To remove the surround with integrated screen, pull the bottom edge of the
surround outward to disengage the magnets and then lift the top up and off the
upper brackets.
8. To prevent damage to the surround with integrated screen, always set the
surround in a safe place while it is removed from the fireplace.
38
SÓLAS CONTEMPORARY FIRE
LIGHTING & OPERATION
FIRST FIRE INSTRUCTIONS
When operating your new fireplace for the first time, some vapors may be
released due to the curing compounds used in the manufacture of the appliance.
They may cause a slight odor and could cause the flames to be the full height
of the firebox, or even slightly higher, for the first few hours of operation.
It is possible that these vapors could set off smoke detection alarms in the
immediate vicinity. These vapors are quite normal on new appliances. We
recommend opening a window to vent the room during the burn off period. After
a few hours use, the vapors will have disappeared and the flames will be at
their normal height.
Follow these instructions for a successful first fire; 1. Turn the fireplace
on in Manual Mode. 2. Set flame height to HI. 3. Let the fireplace run for 3
hours at this setting then shut
off fireplace and let it cool. 4. After the fireplace cools, turn the
fireplace on in manual
mode with flame on HI. 5. Allow fireplace to run for 6 hours in this setting.
NOTE: Slight Odors may still be noticed on future uses of the fireplace but
will diminish over time. The type of finishing materials used around the
fireplace may add odors or add to the curing time. If the fireplace has not
been used in several months, it is normal for odors to occur caused by lint or
dust that has settled on the unit while not in use.
SERVICING
If any attention is required for your appliance, contact your dealer quoting
the model number and serial number. This number is on the rating plate, which
is located adjacent to the control module. The replacement parts are shown at
the end of this manual. Please always quote the part number and description
when requesting spare parts. Warranty is void if serviced by a non-licensed
technician.
FIREPLACE CONTROL DEVICES
There are two ways to control your fireplace. 1. SÓLAS One-Touch Remote
(S-507) 2. Optional Wall Touch Pad (WTP-1500)
The SÓLAS One-Touch Remote can be programmed to function automatically–see
pages 41-48.
The ptional Wall Touch Pad can be used to turn the flame on, off, and to
increase or decrease the flame height.
NOTE: The SÓLAS One-Touch Remote in the AUTO mode will override the Wall Touch
Pad.
FLAME SUPERVISION DEVICE
For your safety, this appliance is fitted with a flame supervision device
which will shut-off the gas supply if, for any reason, the pilot flame goes
out. This device incorporates a fixed probe, which senses the heat from the
pilot flame. If the probe is cool, the device will prevent any gas flow unless
manually lighting the pilot. See full lighting instructions.
NOTE: Periodically conduct a visual check to ensure the
pilot and burner flames are as shown (top of page 40).
During extreme cold weather, it is recommended that you leave the pilot
running to prevent condensation forming in the firebox and on the glass
viewing area during startup.
LIGHTING, OPERATION & RATING INFO
The Lighting, Operation and Rating information is located on a plate on the RH
side of the firebox.
To access the plate, remove the surround and grab the plate and slide it up to
read it. There is important information on both sides of the plate.
AM PM
SÓLAS One-Touch Remote Part #S-507
UP ON-OFF
DOWN
Wall Touch Pad Part #WTP-1500
(Optional)
NOTE: The Wall Touch Pad is not compatible with the SÓLAS Self-Calibrating Power Vent System.
solasfires.com
39
LIGHTING & OPERATION
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, technicianal injury or loss of life.
Flame
When lighting this appliance, follow instructions exactly.
A. This appliance is equipped with an ignition device that automatically
lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING THE BURNER SYSTEM, smell around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
· Do not try to light the appliance.
· Do not touch any electric switch; do not use any telephone in your building.
· Immediately call your gas supplier from a neighbor’s telephone. Follow the
gas supplier’s instructions
· If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to operate the gas controls. Never use tools. If a knob
will not push in or turn by hand, don’t try to repair it, call a licensed
service technician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a licensed service technician to inspect the appliance and to replace any
part of the control system which has been under water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. This appliance is equipped with an ignition device that automatically
lights the pilot. Do not try to light the pilot by hand.
3. Confirm that the remote LCD display says “OFF”. Visually check there is no
pilot flame visible inside the fireplace.
4. Wait five (5) minutes to clear out any gas. Then smell for gas including
near the floor. If you smell gas, STOP! Follow “B” in the safety information
above. If you don’t smell gas, proceed to step 5.
5. Using either the Remote or the optional Wall Touch Pad, press and hold the
“ON/OFF” button for 4 seconds. An audible signal confirms the start sequence
has begun.
6. Continuing beeps confirm the ignition is in process. Once lighting the
pilot flame should appear as shown below. Once the pilot is confirmed, the
main burner ignites on high.
Pilot Light
Flame
Pilot Light Location
NOTE: If the pilot does not stay lit after several tries, proceed to step 9.
7. Use the flame height adjustment buttons on either the Remote or the
optional Wall Touch Pad to adjust the flame. To increase flame height, press
and hold . To decrease flame height, press and hold .
8. Press and hold the button on the Remote or optional Wall Touch Pad to set
the appliance to Pilot flame only.
9. If the appliance will not operate, follow the instructions “TO TURN OFF
GAS TO THE APPLIANCE” and call your gas service technician or gas supplier.
TO TURN OFF GAS TO THE APPLIANCE
1. To turn off gas to the appliance, push and release the “OFF” button on
either the Remote or the optional Wall Touch Pad. An audible signal will
confirm.
2. TO TURN OFF THE GAS SUPPLY TO THE APPLIANCE, close the shut-off valve on
the gas supply line to the appliance.
AM PM
ON/OFF
HI Flame
LO Flame
40
SÓLAS CONTEMPORARY FIRE
SÓLAS ONE TOUCH REMOTE OPERATION
SÓLAS ONE TOUCH REMOTE PAIRING SET UP
The Control Module and the Remote must be paired before the first use. This
has been completed for you at the factory. Refer to the section below if the
Control Module and Remote lose synchronization.
1. Insert two AAA alkaline batteries in the Remote. Only use brand name
alkaline batteries, such as Duracell or Energizer.
2. Four AA alkaline batteries are installed in the Control Module (shown
below).
3. Locate the RESET button on the front side of the Control Module.
4. Press and hold the Control Module’s RESET button until you hear one short
beep and one long beep. After the second beep, release the reset button.
5. Within the subsequent 20 seconds, press and hold the button on the Remote
for 2-3 seconds. will be displayed and flash on the Remote during the pairing
sequence. The Remote will count up from 1 to 8, and you will hear two short
beeps confirming the pairing is complete.
If you hear one long beep, the pairing sequence has failed or the wiring is
incorrect.
This is a one time pairing and is not required when changing the batteries of
the Remote or Control Module. The remote control system is now ready to use.
SÓLAS One-Touch Programmable
Thermostatic Remote Part #S-507
NOTE: The batteries in your SÓLAS One-Touch remote control and control module are to be replaced annually.
RESET Button
SÓLAS One-Touch Control Module Part #S-504
solasfires.com
41
SÓLAS ONE TOUCH REMOTE OPERATION
HOW TO TURN YOUR FIREPLACE OFF
(INCLUDING PILOT)
Familiarize yourself with each of these methods before operating your
fireplace.
Remote and Wall Touch Pad: Press and hold the ON-OFF button for a second
(either on the Remote or the optional Wall Touch Pad).
If the flames are on, they go down and you hear the valve motor wind down. You
hear a clunk and a beep indicating that the valve has received the signal from
the Remote.
HOW TO ENSURE YOUR FIREPLACE CANNOT BE TURNED ON INADVERTENTLY
You can use the following method to ensure that your fireplace will not turn
on when you don’t want it on.
First, ensure your fireplace is turned off–including the pilot–and cold BEFORE
going ahead.
· Close the shut-off valve on the gas supply line to the appliance.
· Remove all batteries from the Control Module as well as the batteries from
the Remote.
· If unit is hardwired, shut-off power at the breaker.
Countdown Timer
ON/OFF
Program Mode
Auxiliary Feature
(not used)
Comfort Blower (no(ut usseedd)if unit is
equipped with blower)
AM PM
SÓLAS One-Touch Programmable
Thermostatic Remote Part #S-507
Main Display
Thermostatic Mode
Increase Flame
Decrease Flame Split Flow Mode
(not used)
Light (not used)
Automatic Shut-Off (in certain conditions)
Your fireplace’s Remote is equipped with an automatic shut-off mechanism which
is activated in certain conditions. See page 47 in the Remote Control
Operation section for a description of this feature.
NOTE: Before using the remote control system for the first time, the Control
Module and the Remote are synchronized at the factory. See the section SÓLAS
Remote Pairing Set-up on page 41 of this manual if the Control Module and
Remote lose synchronization.
IMPORTANT: BEFORE YOU BEGIN, please note that with this system, the settings
of time, temperature and automatic ON/OFF can only be programmed when the
function display is flashing. Be patient when programming as it does take time
to set-up.
UP ON-OFF
DOWN
SÓLAS Wall Touch Pad* (Optional)
Part #WTP-1500
*Not Compatible with SÓLAS Self-Calibrating Power Vent Kit
42
SÓLAS CONTEMPORARY FIRE
SÓLAS ONE TOUCH REMOTE OPERATION
ONE TOUCH REMOTE MAIN DISPLAY OVERVIEW
Child Proof Countdown Timer
Program Mode
Time
ON OFF
Signal Indicator Thermostatic Mode
AM PM
Battery Status
Comfort Blower (not used) °F or °C Light (not used)
Split Flow Mode (not used)
Temperature
Auxiliary Feature (not used)
DO NOT leave the Remote on the hearth, mantel, or on top of the fireplace. Use
the Remote wall mount holder provided.
The SÓLAS One-Touch Remote Control comes with a wall bracket. Mount the wall
bracket in the same room as the fireplace. Approximately 8-10 feet from the
fireplace.
solasfires.com
43
SÓLAS ONE TOUCH REMOTE OPERATION
TO TURN ON FIREPLACE
CAUTION
WHEN PILOT IGNITION IS CONFIRMED, MOTOR TURNS AUTOMATICALLY TO MAXIMUM FLAME
HEIGHT.
One-Touch Lighting (default):
Press and hold for 4 seconds,
until 8 short beeps and a blinking
AM
series of lines confirms the start
PM
sequence has begun. Release
button.
Main gas flows once pilot ignition is confirmed.
Remote automatically goes into manual mode after main burner ignition. The fireplace will default to HI flame.
TO TURN OFF FIRE
· Press to turn OFF. When the pilot is off, it will take 2 minutes before it
can be lit again.
NOTE: There is a 2 minute delay
after switching off before the next ignition is possible.
CAUTION
Always check the fire and pilot visually to ensure they are off.
STANDBY MODE PILOT FLAME
Press and hold to set appliance to pilot flame.
AM PM
FLAME HEIGHT ADJUSTMENT
To increase flame height, press and hold .
AM PM
To decrease flame height, press and hold . You may hold the button down until
the fire is set to pilot flame only.
DESIGNATE LOW AND HIGH FIRE
CAUTION
If the pilot does not stay lit after several tries call your local service
technician or gas supplier.
Double-Click DOWN Arrow
AM
button. “LO” is displayed.
NOTE: Flame goes to high fire first before going to designated low fire.
Double-Click UP Arrow button.
AM
Flame automatically foes to high
fire. “HI” will be displayed.
44
SÓLAS CONTEMPORARY FIRE
SÓLAS ONE TOUCH REMOTE OPERATION
SETTING CELSIUS OR FAHRENHEIT
To change between °C and °F, press and hold + simultaneously.
Note: When Remote is in °C
AM PM
(Celsius) mode the clock will
be 24-hour. When Remote is
in °F (Fahrenheit) mode the
clock will be 12-hour.
CHILD PROOF
Your Remote can be set to lock out all commands to the fireplace, except OFF.
To turn Child Proof ON:
1. Press and hold + simultaneously. 2. is displayed. Child Proof is now
active.
To turn Child Proof OFF:
1. Press and hold + simultaneously. 2. disappears. Child Proof is now
inactive, and the
Remote has full function.
SETTING THE TIME
1. Press + simultaneously. Day flashes.
2. Press + to select a number to correspond with the day of the week. · 1 =
Monday · 2 = Tuesday · 3 = Wednesday · 4 = Thursday · 5 = Friday · 6 =
Saturday · 7 = Sunday
3. Press + simultaneously. Hour flashes.
4. To select hour press or .
5. Press + simultaneously. Minutes flash.
6. To select minutes press or .
7. To confirm, press or simultaneously or wait.
COUNTDOWN TIMER
You can set your fireplace to automatically turn off at the end of a timer. To
set a Countdown Timer:
1. Press and hold until is displayed. Hour flashes.
2. Press or to select Hour. 3. To confirm, press . Minutes flash.
4. Press or to select Minutes. 5. To confirm, press or wait.
To turn off a Countdown Timer:
1. Press , and the countdown disappears.
NOTE: The Countdown Timer only works in Manual and Thermostatic modes. Maximum
countdown time is 9 hours and 50 minutes.
AM
solasfires.com
45
SÓLAS ONE TOUCH REMOTE OPERATION
MODES OF OPERATION
Manual Mode
The ON/OFF status of the fireplace, as well as flame height, are manually
controlled by the user.
Thermostatic Mode
The room temperature is measured and compared to the set temperature. The
flame height is automatically adjusted to achieve the set temperature.
ON:
Press . is displayed. Preset temperature displays briefly, followed by the
room temperature.
Setting Desired Temperature:
1. Press and hold until is displayed and set temperature flashes.
2. To adjust set temperature, press or .
3. To confirm, press or wait.
OFF: 1. Press 2. Press 3. Press
. or to go to Manual Mode. to go to Program Mode.
Program Mode
The temperature is controlled by
Programs 1 and 2, each of which can
ON OFF
be set to go on and off at specific
times, at a set temperature.
PROGRAM MODE
ON: Press .
, 1 or 2, ON or OFF are displayed. ON OFF
OFF:
1. Press , or to go to Manual Mode.
2. Press to go to Thermostatic Mode.
NOTE: The set temperature for Thermostatic Mode is the temperature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.
Default Settings:
· ON TIME (Thermostatic) TEMPERATURE: 70°F / 21°C
· OFF TIME TEMPERATURE: ”
” (pilot flame only)
Temperature Setting:
1. Press and hold until flashes. ON and
set temperature (set in Thermostatic Mode)
is displayed.
ON
2. To continue, press or wait. , OFF displayed, temperature flashes.
3. Select off temperature by pressing or . 4. To confirm, press .
NOTE: The on (Thermostatic) and off set temperatures are the same for each day.
Day Setting:
1. ALL flashes. Press or to choose between: · ALL = same settings ON-OFF
every day · SA:SU = same settings ON-OFF Saturday and Sunday · 1, 2, 3, 4, 5,
6, 7 = daily timer–unique ON-OFF settings for a single day of the week, for
multiple days of the week or for every day of the week.
2. To confirm, press .
ALL Selected
On Time Setting (PROGRAM 1)
1. , 1, ON are displayed.
ALL is displayed briefly. Hour flashes.
ON
2. To select hour, press or .
3. To confirm, press . , 1, ON are displayed. ALL displayed briefly. Minutes
flash.
4. To select minutes, press or . 5. To confirm, press .
46
SÓLAS CONTEMPORARY FIRE
SÓLAS ONE TOUCH REMOTE OPERATION
PROGRAM MODE Continued
Off Time Setting (PROGRAM 1)
1. , 1, OFF are displayed. ALL is
displayed briefly. Hour flashes.
OFF
2. To select hour, press or .
3. To confirm, press . , 1, OFF are displayed. ALL displayed briefly. Minutes flash.
4. To select minutes, press or .
5. To confirm, press .
NOTE: Either continue to PROGRAM 2 and set ON and OFF times or stop programming at this point, and PROGRAM 2 remains deactivated.
NOTE: PROGRAM 1 and 2 use the same ON (Thermostatic) and OFF temperatures. Once a new ON (Thermostatic) and/or OFF temperature has been set, that temperature becomes the new default setting.
NOTE: ON and OFF times programmed for PROGRAM 1 and PROGRAM 2 become the new default times.
The batteries must be removed to clear the PROGRAM 1 and PROGRAM 2 ON and OFF times and temperatures.
SA: SU or Daily Timer (1-7) Selected
· Set ON time and OFF time using the same procedure as “ALL Selected” above.
· Waiting to finish setting.
LOW BATTERY INDICATION
CAUTION
Do not use a screwdriver or other metallic object to remove the batteries from
the Control Module battery holder or the Remote. This could cause a short
circuit.
NOTE: The batteries in your SÓLAS One-Touch remote control and control module are to be replaced annually. Only use brand-name alkaline batteries such as Duracell or Energizer.
Remote
The battery icon
will show when the battery needs
to be replaced. Replace with two 1.5 V AAA alkaline
batteries.
Control Module
Frequent beeps for 3 seconds when the motor turns indicate the batteries in
the battery holder of the Control Module need to be replaced. Replace with
four 1.5 V AA alkaline batteries.
AUTOMATIC SHUT OFF
Countdown Timer
At the end of countdown time period, the fire turns off. The Countdown Timer
only works in Manual and Thermostatic. Maximum countdown time is 9 hours and
50 minutes.
Seven Day Shut Off
If there is no activity for 7 days, the SÓLAS fireplace will automatically
shut down the pilot as required by certain jurisdictions.
AUTOMATIC TURN DOWN
3 Hour No Communication Function
If your fireplace and remote are inactive for three hours– for example, if the
remote is left in another room–your fireplace automatically turns down to
pilot.
Benefit SÓLAS products are designed with a focus on safety and environmental
responsibility. This will help save fuel and is an environmental benefit.
Program the temperature and timer modes to maximize your heating efficiency.
solasfires.com
47
SÓLAS ONE TOUCH REMOTE OPERATION
ERROR CODE
MESSAGE
F04
F04
F06
F06
F07
Low Battery Symbol
F09
F09
F46
F46
DURATION OF DISPLAY 4 seconds
4 seconds
Permanent
SYMPTOM
· No pilot flame within 30 sec · Note: After 3 failed ignition
sequences, F06 shown
· 3 failed ignition sequences in 5 minutes
· Fire is not responding, no pilot flame
· Battery icon flashes on Remote display
POSSIBLE CAUSE
· No gas supply · Air in pilot supply line · No spark · Reversed polarity in
thermocouple
wiring
· No gas supply · Air in pilot supply line · No spark · Reversed polarity in
thermocouple wiring · Incorrect pilot orifice if valve has
been converted from LPG to NG or vice versa
· Low battery in Remote
4 seconds 4 seconds
· Fire is not responding · No electronic control of fire
· Fire is not responding · Intermittent response · No electronic control of
fire
· Down arrow button was not pressed during pairing
· Control Module and Remote are not synced
· No or bad connection between Control Module and Remote
· No power at Control Module (batteries low)
· Low communication range (main adapter faulty, Remote not communicating with
Control Module)
SÓLAS ONE TOUCH REMOTE TIPS
· Double-click to go directly to LO (lowest) flame setting.
· Double-click to go directly to HI (highest) flame setting.
· Only use brand name alkaline batteries, such as Duracell or Energizer.
· When using the Remote, it should be within 15 feet (4.5 meters) of the
fireplace.
· Don’t leave the Remote on the mantel or hearth or any hot surfaces. Use the
Remote wall holder provided.
· To keep out of children’s reach, use the Remote wall holder provided.
· Be patient when programming: it takes time to set-up.
· Once you turn a pilot off, it takes a few minutes before your can turn it
back on.
Your SÓLAS Dealer is here to help, if you have any trouble with your SÓLAS Fireplace or SÓLAS One-Touch Remote. Please contact your Dealer for support.
48
SÓLAS CONTEMPORARY FIRE
GAS CONVERSION
This appliance is field convertible when a SÓLAS gas conversion kit is used. Gas conversions must be performed by a licensed service technician. Before servicing the appliance, shut off gas and electrical power to the unit.
PART #
DESCRIPTION
SL26-LPC TWENTY6 LP CONVERSION KIT
SL26-NGC TWENTY6 NG CONVERSION KIT
27 PILOT ORIFICE #35 PILOT ORIFICE
SÓLAS CONVERSION KIT CONTENTS
55 LP BURNER ORIFICE 1PC
8 SCREW 1PC
Gas Conversion Labels
5/64″ NG BURNER ORIFICE 1PC
NG Inlet Tube Collar1PC #8 SCREW 1PC
Gas Conversion Labels
1. Remove the surround with integrated screen. Pull the bottom edge of the surround outward to disengage the magnets and then lift the top up and off the upper brackets. To prevent damage to the surround with integrated screen, always set the surround in a safe place while it is removed from the fireplace.
3. Remove the bottom outer panel by removing the #10 sheet metal screws, using a / nut driver or ratchet with extension.
4. Remove the 2 Phillips head screws from the outer edges of the bottom outer panel.
2. Remove front glass panel and frame. Refer to page 35 (Installing the Front Glass Panel and Frame section) Reverse steps starting with Step 5 and end with Step 1.
solasfires.com
49
GAS CONVERSION
5. Locate and remove the (4) #10 sheet metal screws that hold the burner into the firebox. These are located on the outer edges below the burner. See photos below.
7. With the burner out of the fireplace, using a / ” deep socket, remove the orifice and replace it with the correct fuel you are converting to.
Screws
Screws
8. Next convert the burner to the fuel desired. When converting to propane, remove the collar on the burner inlet tube. When converting to natural gas install the collar over the burner inlet tube and secure with a #8 sheet metal screw provided using a ¼” nut driver.
6. Slide the burner to the right and then up to disengage from orifice.
Collar OFF for LP
Collar ON for NG
9. Using a nut driver, remove the (2) sheet metal screws that hold the pilot assembly in place.
50
SÓLAS CONTEMPORARY FIRE
GAS CONVERSION
10. Lift the pilot assembly into the fireplace which will give you access to the fittings under the pilot assembly. Take extra caution to not damage ceramic electrode on pilot assembly.
12. Once the pilot gas line is tightened, reinstall the pilot assembly in the
fireplace using the two #10 sheet metal screws provided. Ensure pilot gasket
is intact.
13. Reinstall burner and media into fireplace with #10 sheet metal screws
from the bottom that you removed in step 5.
11. Using a 10mm wrench, remove the pilot gas line and swap the pilot orifice with the one supplied in the conversion kit. Be sure that the pilot orifice is fully seated and the pilot gas line is tightened properly to prevent leaks around the orifice. If not seated properly this will cause an unusually high pilot flame.
GAS FLOW ADJUSTMENT
It is required you adjust the gas valve when converting the fireplace.
1. Locate and remove the pressure conversion brass plug and set it for NG or
LP accordingly. Reinstall and tighten.
Pilot orifice correctly seated
solasfires.com
51
GAS CONVERSION
2. Confirm inlet pressure of gas (right pressure tap on valve) is between 5.5″ w.c. to 10.0″ w.c. for natural gas and 11″ w.c. to 13″ w.c. for propane. If pressure is not within these parameters, correct any gas supply pressure issue before continuing with conversion. Close the pressure tap.
6. With the fireplace set on the lowest flame level, set the low manifold pressure by adjusting the 4mm allen screw on the bottom side of the valve. Refer to the chart below for low manifold pressure settings which vary per model fireplace.
MANIFOLD INLET
3. Install a pressure gauge on the outlet pressure tap on the valve.
4. Light the fireplace using the remote control.
5. With the fireplace set on the highest flame level, set the high manifold
pressure by adjusting the small flat screw set within the brass pressure
conversion plug. Refer to the chart below for high pressure settings which
vary per model fireplace.
7. Ensure all pressure taps are closed and check all connections/pressure taps for leaks.
MODEL
TWENTY6 – NG TWENTY6 – LP
HIGH PRESSURE 4.8″w.c. / 1.2kPa 10.0″ w.c. / 2.5kPa
LOW PRESSURE 1.25″w.c. / 0.31kPa 4.2″ w.c. / 1.1kPa
52
SÓLAS CONTEMPORARY FIRE
GAS CONVERSIONGAS CONVERSION LABEL INSTRUCTIONS
1. When converting this fireplace, use a permanent marker to complete the
supplied gas conversion label then affix it to the right side of fireplace
above the control module as pictured below.
SÓLAS This fireplace has been converted in the field. This label must
be filled out with indelible ink and affixed in a conspicuous location near
the appliance listing label.
Appliance Model: __ Converted to: NG LP Gas Conversion Kit No.
____ This Appliance was Converted on
(MM/DD/YYYY): __ This Gas Conversion was Completed by:
__ Address:
__ CAUTION:
This gas conversion must be completed by a licensed gas installer.
Manufactured by: Progressive Manufacturing Inc., 452 Sunapee St., Newport, NH
03773 USA
2. Affix the supplied rating plate conversion label to the rating plate. Be
sure to not cover the Model and Gas Pressure information for the model and
fuel you are converting to. With a permanent marker, check off the fuel type
you are converting to.
This Fireplace has been converted.
See conversion label in fireplace.
This Fireplace has been converted.
See conversion label in fireplace.
solasfires.com
53
MAINTENANCE
ANNUAL MAINTENANCE
A licensed service agency should conduct an annual inspection and maintenance
of your SÓLAS Gas Fireplace including the overall installation and venting to
keep it running safely. The following procedures should be performed only by a
licensed service technician. The gas supply should be turned off and the stove
should be completely cool whenever a maintenance procedure is performed. All
parts of the appliance that are removed for servicing must be replaced prior
to operation.
This appliance should be inspected before use and at least annually by a
licensed service technician. More frequent cleaning may be required due to
excessive dust or lint from carpeting, bedding materials, pets, etc. It is
imperative that control compartments and circulating air passageways of this
appliance be kept clean.
CLEANING THE BURNER & FIREBOX
During the annual inspection and maintenance appointment, the service
technician should clean the burner and firebox. To gain access to the firebox
and burner, reverse steps 1-5 on page 35 of this manual.
DO NOT USE A VACUUM CLEANER TO CLEAN THE GLASS BURNER MEDIA.
A vacuum cleaner may be used to clean the metal parts of the firebox. Leave
the glass burner media in place. Use a soft brush to clean the burner glass
media. If the burner media does need to be removed, carefully scoop it off the
burner and avoid dropping glass pieces in the air gaps around the burner.
Follow the instructions on pages 33 and 34 of this manual when replacing the
burner media on the burner top.
After service is complete, replace front glass panel and frame, following
steps 1-5 on page 35 of this manual.
AIR FLOW
The SÓLAS Gas Fireplace utilizes a convection air heat exchange system to
maximize heat delivered from the fireplace. It is important that air flows
freely through the convection air system and out the air grills. Do not place
objects against the fireplace that will block the convection air inlet flow or
in front of any air outlet.
CLEANING GLASS AND PORCELAIN ENAMEL PANELS
WARNING: Never clean the Glass or Enamel Panels while they are hot. Do not use
abrasive cleaners or cleaners containing ammonia.
When the fireplace is first operated, there may be some vapors and a visible
white film left on the glass and panels. This white film, a mineral deposit,
is a normal by-product of the combustion process in a gas appliance. The
composition of the deposit varies with location and time and is believed to be
associated with varying sulfur content in the gas. You may experience this
problem intermittently.
We have consulted with ceramic glass manufacturers and they cannot offer a
definitive solution to the issue. The following are recommendations only and
are not meant to guarantee results. NOTE: This is an issue beyond SÓLAS’s
control and is not covered under warranty.
· Clean the glass and porcelain enamel panels regularly as soon as you notice
a white film build-up. If the film is left for a longer period of time it will
etch into the glass and may be harder or impossible to remove.
· NEVER use an abrasive cleaner or an Ammonia-based cleaner on the ceramic
glass. An abrasive cleaner will compromise the strength of the glass, An
emulsion type cleaner is recommended.
· Use a damp, soft micro-fiber cloth or cotton cloth to apply the cleaner. Dry
glass with a soft, dry cloth. (Paper towels and synthetic materials are
abrasive to ceramic glass and should not be used)
· We have had good results from the following products, however we cannot
guarantee results; Brasso, Polish Plus by Kel-kem, Cook Top Clean Creme by
Elco, White Off by Rutland, Turtle Wax.
· DO NOT CLEAN GLASS WHILE IT IS HOT!
NOTE: The batteries in your SÓLAS One-Touch remote control and control module
are to be replaced annually. Only use brand name alkaline batteries such as
Duracell or Energizer.
54
SÓLAS CONTEMPORARY FIRE
MAINTENANCE
BATTERY REPLACEMENT
CONTROL MODULE BATTERIES
Inside your fireplace, there are (4) AA batteries installed inside of the
control module. Frequent beeps for 3 seconds when the motor turns indicates
the batteries inside the Control Module are low. 1. Remove surround from
Fireplace. Reversing steps as
shown on pages 37-38. 2. Loosen silver thumb screw located on the top right
side
of the control module.
4. The cover on the control module slides up, exposing the (4) AA batteries. Replace with (4) AA alkaline batteries, making sure the battery orientation is correct. SÓLAS recommends using a name brand battery such as Duracell or Energizer.
3. Slide the control module assembly up and to the left as shown.
5. Replace the battery cover, slide control module back into the fireplace
and tighten silver thumb screw.
6. To reinstall the Fireplace surround, follow the steps on page 37-38.
SÓLAS ONE TOUCH REMOTE BATTERIES
Your remote display will indicate when the batteries are low .
The remote uses (2) AAA alkaline batteries– when replacing, be sure the
battery orientation is correct. SÓLAS recommends using a name brand such as
Duracell or Energizer.
The batteries should last one full season, depending on usage.
Remove the batteries in the off-season to extend battery life.
solasfires.com
55
MAINTENANCE LOG
We strongly recommend that you keep a log of the regular maintenance that is
performed on your SÓLAS fireplace. We have provided the maintenance form below
to make it easy. Simply ask your licensed service technician to fill out one
of the maintenance record forms below each time the fireplace is serviced.
This will help insure that all of the required maintenance procedures have
been completed, at least annually. Regular maintenance will help keep the
fireplace functioning in a safe and reliable manner. Additional forms are
available from your installer or service technician when needed.
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
Date of Service: ___
Serviced By: __
Service Performed: Clean Burner & Firebox Clean Control Area Clean Convection
Air System Leak Test Gas Connections Replace Batteries in Control Module &
Remote Clean Firebox Panels and Glass Other__
56
SÓLAS CONTEMPORARY FIRE
REPLACEMENT PARTS LIST
PART NAME
P/N
PART NAME
Pilot Head NG/LP
26-501
/ ” Burner Orifice (NG)
Pilot Thermocouple*
M26-502*
55 Burner Orifice (LP)
35 Pilot Orifice (NG)
26N-503
Burner Glass Media Clear
27 Pilot Orifice (LP)
26P-503
Burner Module (NG)
SÓLAS One-Touch Control Module Wall Touch Pad** (Optional) SÓLAS One-Touch Remote Gas Valve (Maxitrol)
S-504 WTP-1500 S-507 M46-515
Burner Module (LP) Firebox Panel Rear Firebox Panel Left Firebox Panel Right
TC Line Red TC Line Yellow
M46-701 M46-702
Thermocouple Interrupter Block 8-Wire Connecting Cable
Glass Assy (including gasket & frame)
*This is a quick response thermocouple. Replace it only with SÓLAS Part Number M26-502. **Not Compatible with SÓLAS Self-Calibrating Power Vent Kit
P/N 26N-509 26P-509 26-511 26N-901 26P-901 26-512 26-513 26-514 M46-703 M46-704 26-510
For Replacement Parts and customer service, contact your SÓLAS Dealer or;
SÓLAS, LLC 452 Sunapee Street, Newport, NH 03773 P
603-298-5169 sales@solasfires.com
solasfires.com
57
CONTROL SCHEMATIC
Pilot Assembly
8 Wire Connecting Cable
GV60 Gas Valve
Thermocouple Integrated Interrupter Block
Electrode (Ignition) Cable
Thermo Current Yellow Cable
Thermo Current Red Cable
AM PM
SÓLAS One-Touch Remote Handset
Control Module
UP ON-OFF
DOWN
Wall Touch Pad (Optional)
Not Compatible with SÓLAS Self-Calibrating
Power Vent Kit
Caution
Label all wires prior to disconnection when servicing the controls. Wiring
errors can cause improper and dangerous operation. Verify proper operation
after servicing.
For Replacement Parts and customer service, contact your SÓLAS Dealer or;
SÓLAS, LLC 452 Sunapee Street, Newport, NH 03773 P
603-298-5169 sales@solasfires.com
58
SÓLAS CONTEMPORARY FIRE
WARRANTY INFORMATION
THE WARRANTY
SÓLAS, LLC, a division of Progressive Manufacturing, Inc. (“SÓLAS”), Limited
Lifetime Warranty warrants your SÓLAS brand gas fireplace (“Product”) to be
free from defects in materials and workmanship at the time of manufacture. The
Product body and firebox carry the Limited Lifetime Warranty on workmanship
defects causing loss of structural integrity. Ceramic glass carries the
Limited Lifetime Warranty against thermal breakage only. After installation,
if covered components manufactured by SÓLAS are found to be defective in
material or workmanship during the Limited Lifetime Warranty period and while
the Product remains at the site of the original installation, SÓLAS will, at
its option, repair or replace the covered components. If repair or replacement
is not commercially practical, SÓLAS will, at its option, refund the purchase
price or wholesale price of the SÓLAS product, whichever is applicable. SÓLAS
will also pay their prevailing labor rates, as determined in its sole
discretion, incurred in repairing or replacing such components during the
warranty period. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Lifetime
Warranty as described herein.
COVERAGE COMMENCEMENT DATE Warranty coverage begins on the date of
installation. The warranty shall commence no later than 24 months following
the date of product shipment from SÓLAS, regardless of the installation date.
EXCLUSIONS AND LIMITATIONS This Limited Lifetime Warranty applies only if the
Product is installed in the United States or Canada and only if operated and
maintained in accordance with the printed instructions accompanying the
Product and in compliance with all applicable installation and building codes
and good trade practices.
This warranty is non-transferable and extends to the original owner only. The
Product must be purchased through a listed supplier of SÓLAS and proof of
purchase must be provided. The Product body and firebox carry the Limited
Lifetime Warranty. The following do not carry the Limited Lifetime Warranty,
but are warranted as follows:
· Burner Repair or replacement for three years from date of installation.
· Gas components & electrical components Repair or replacement for one year
from date of installation.
· Blowers & remote controls Repair or replacement for one year from the date
of installation.
· Porcelain Firebox Liners Replacement for one year against cracking or
breakage due to thermal stress from date of installation. Excludes surface and
hairline cracks and scratches or slight color changes that do not affect the
operation or safety of the unit.
· Gaskets Repair or replacement for one year from the date of installation.
· Surrounds Replacement for one year against cracking or breakage due to
thermal stress. Excludes surface and hairline cracks and scratches or slight
color changes that do not affect the operation or safety of the unit.
· Labor coverage Prevailing SÓLAS rates apply for the warranty period of the
component. SÓLAS will not be liable for travel costs for service work.
SÓLAS will not be responsible for: (a) damages caused by normal wear and tear,
accident, riot, fire, flood, or acts of God; (b) damages caused by abuse,
negligence, misuse, or unauthorized alteration or repair of the Product
affecting its stability or performance. The Product must be subjected to
normal use. The product is designed to burn either natural or propane gas
only. Burning conventional fuels such as wood, coal or any other solid fuel
will cause damage to the Product, will produce excessive temperatures and
could result in a fire hazard. (c) Damages caused by failing to provide proper
maintenance and service in accordance with the instructions provided with the
Product; (d) damages, repairs or inefficiency resulting from faulty
installation or application of the Product.
Discoloration and some minor expansion, contraction, or movement of certain
parts and resulting noise is normal and not a defect, and, therefore, not
covered under warranty. The installer must ensure the appliance is burning as
per the rating tag at the time of installation. Over-firing (operation above
the listed BTU rate) of this appliance can cause serious damage and will
nullify this warranty.
This warranty is void if:
a) The unit has been operated in atmospheres contaminated by chlorine,
fluorine or other damaging chemicals.
b) The unit is subject to submersion in water or prolonged periods of dampness
or condensation.
c) Any damage to the unit, combustion chamber, heat exchanger or other
components due to water or weather damage which is the result of, but not
limited to improper chimney/venting installation.
Damage to stainless steel, gold, nickel or porcelain enameled surfaces caused
by fingerprints, scratches, melted items, or other external sources left on
these surfaces from the use of cleaners is not covered in this warranty.
SÓLAS is not responsible for inadequate fireplace system draft caused by air
conditioning and heating systems, mechanical ventilation systems, or general
construction conditions which may generate negative pressure in the room in
which the appliance is installed. Additionally, SÓLAS assumes no
responsibility for drafting conditions caused by venting configurations,
adjoining trees or buildings, adverse wind conditions or unusual environmental
factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein.
In no case shall SÓLAS be responsible for materials, components, or
construction, which are not manufactured or supplied by SÓLAS or for the labor
necessary to install, repair, or remove such materials, components, or
construction. Additional utility bills incurred due to any malfunction or
defect in equipment are not covered by this warranty. All replacement or
repair components will be shipped F.O.B. from the nearest stocking SÓLAS
facility.
LIMITATION ON LIABILITY It is expressly agreed and understood that SÓLAS’ sole
obligation and the purchaser’s exclusive remedy under this warranty, under any
other warranty, expressed or implied, or in contract, tort or otherwise, shall
be limited to replacement, repair, or refund, as specified herein.
In no event shall SÓLAS be liable for any incidental or consequential damages
caused by defects in the Product, whether such damage occurs or is discovered
before or after repair or replacement, and whether such damage is caused by
SÓLAS’ negligence. SÓLAS has not made and does not make any representation or
warranty of fitness for a particular use or purpose, and there is no implied
condition of fitness for a particular purpose.
SÓLAS makes no expressed warranties except as stated in this Limited Lifetime
Warranty. The duration of any implied warranty is limited to the duration of
this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for
SÓLAS any other obligation or liability in connection with the Product. Some
states and provinces do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to
you. The provisions of this Limited Lifetime Warranty are in addition to and
not a modification of or subtraction from any statutory warranties and other
rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY SÓLAS reserves the right to
investigate any and all claims against this Limited Lifetime Warranty and to
decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime
Warranty, the appliance must be installed and repaired by a licensed
contractor approved by SÓLAS.
Contact SÓLAS at the address provided herein to obtain a listing of approved
dealers/distributors. SÓLAS shall in no event be responsible for any warranty
work done by a contractor that is not approved without first obtaining SÓLAS’
prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this
warranty to be valid, you must contact the SÓLAS dealer/distributor from which
you purchased the product. If you cannot locate the dealer/distributor, then
you must notify SÓLAS in writing. SÓLAS must be notified of the claimed defect
in writing within 90 days of the date of failure. Notices should be directed
to the SÓLAS Warranty Department. Visit our website at www.solasfires.com/
warranty.
SÓLAS, LLC
P 603-298-5169 F
603-298-9246
solasfires.com/warranty
59
We recommend that our gas hearth products be installed and serviced by
professionals who are certified in the U.S. by the National Fireplace
Institute® (NFI) as NFI Gas Specialists. www.NFIcertified.org
RECORD YOUR PRODUCT INFORMATION
Model #: ____ Serial Number:
__ D te Purch sed: __ Date
Installed: ___
THANK YOU FOR CHOOSING
solasfires.com
V19/4.25.2023