Sunco WH-2760K 6 Inch Ultra Thin LED Recessed Ceiling Lights Slim User Manual
- June 1, 2024
- SUNCO
Table of Contents
Lighting made better.
SKU: DL_BS6_NL-WH-2760K
User Manual
Recessed LED 6″
Baffle Slim Downlight
Whats in the Box?
Nightlight Downlight
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
- Abide by related regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, relocate, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before installing. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
-
This device may not cause harmful interference.
• Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
• Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
• Use safety precautions and abide by regional and local laws or regulations.
• This product is not compatible with 3rd party sensors.
• This product is not compatible with photo controls.
• This product is not compatible with occupancy sensors.
• This product is not compatible with timing devices.
www.P65Warnings.ca.gov
-
This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quick start Guide
| | |
---|---|---|---
Use template to cut hole.| Connect supply & junction wires.| Attach fixture to
junction box.| Insert fixture into ceiling.
Installation Guide
STEP 1
a. Turn off circuit breaker before installation.
b. Cut out 6.33” housing size on Installation Template, then tape onto ceiling
in desired location.
c. Cut ceiling hole using Installation Template as a guide.
STEP 2
a. Open junction box and remove appropriate knockout.
STEP 3
a. Connect supply and junction wires using wire nuts:
-Black to Black (Live)
-White to White (Neutral)
b. Tuck connected wires inside junction box & close cover.
STEP 4
Insert junction box through ceiling hole.
a. New Construction Applications: Secure to studs, joists, or similar fixed
structural units.
b. Remodel Applications: Do not require to secure to studs, joists, or similar
fixed structural units.
STEP 5
a. Attach fixture to junction box using connector as shown on image (1).
Tighten connector by hand (2).
b. Push up spring clips and insert fixture into ceiling. Turn on circuit
breaker and test light.
STEP 6
Note: To toggle between downlight and nightlight, turn wall switch and night
light off, wait 3 seconds, then switch on.
To reset fixture, turn off, wait 5 seconds, then turn on.
Product Details
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | PD-6WCL-WH |
LEVITON | AYCL-153P-WH |
KASA SMART | DVCL-153P-WH |
KASA SMART | D26HD-2RW |
LUTRON | HS220 |
LUTRON | HS220P3 |
LUTRON | MACL-153M-WH |
Scan for the full compatible dimmer list!
Specifications
Voltage | 120V |
---|---|
Wattage | 14W |
Wattage Equivalency | 140W |
Beam Angle | 90° |
Weight | 0.73lbs |
Housing Material | Plastic |
Dimmable | Yes |
Average Lifetime | 50,000 hrs |
Lumens | 1200LM |
Moisture Rating | Damp |
CRI | 80+ |
Usage | Indoor |
IC Rated | Yes |
Warranty | 7 Years |
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our
troubleshooting section is here to shed some light and provide you with easy-
to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any
questions. Our team of lighting experts are happy to help brighten your day.
Installation
Light isn’t turning on.| Double check if fixture is properly connected
and circuit breaker hasn’t been tripped.
Light isn’t bright enough.| Check proper wattage and for unobstructed fixture.
Dimming
Light not dimming to lowest setting.| Verify dimmer compatibility with
fixture.
Light not dimming smoothly.| Ensure minimum dimmer load requirement is met.
Light not compatible with dimmer switch.| Check light-dimmer compatibility.
Consider purchasing
compatible switch if necessary.
Flickering
Light flickering with other lights on the same circuit.| Check that fixture
wiring connections are secure.
Light is flickering when turning on.| Check that the lights on the same
circuit are not
overloading the circuit.
Light flickering when turned on.| Verify dimmer switch compatibility.
Light flickering when dimmed.| Verify fixture compatibility and that it is
grounded.
Buzzing
Fixture buzzing with appliances or electronic devices.| Verify light is
connected to surge protector securely.
Fixture buzzing when dimmed.| Look for nearby interferences that can cause
buzzing.
Such as televisions, radios, computers, etc.
Fixture buzzing with power outages.| Verify dimmer switch compatibility.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light
source. It is an important factor to consider when selecting a fixture or
bulb, as it affects the way it will illuminate an area. There are two main
types of lighting distribution angles:
A symmetric lighting distribution emits light evenly in all directions,
creating a cone-shaped pattern that provides a pool of light. This type of
lighting is ideal for general lighting and illuminating large areas. Common
applications for symmetric lighting include general area illumination,
security lighting, and perimeter lighting. Symmetric lighting is also used to
a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be
affected by other factors such as the reflector design of the light source,
the type of lens used, and the distance between the light source and the
surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry leading 7 year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
Scan me for two extra years!
https://www.sunco.com/pages/warranty
30 Day Return Policy
At Sunco we value our customers and stand by the quality and performance of
our products.
If you are not completely satisfied with your purchase, we accept returns
within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:
Email: support@sunco.com
Text or Call: 844-334-9938
6AM – 6PM PST Monday – Friday
Lighting made better.support@sunco.com
844-334-9938
REV1.0
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>