Thank you for selecting Globe as your lighting choice for your home. With proper care, this product will provide years of pleasure and enjoyment. Carefully follow the instructions in order to ensure that this product functions safely and properly for years to come.
WIFI MOTION ACTIVATED LED SECURITY LIGHT
SPECIFICATIONS
- Voltage: 120 VAC ~ 60Hz
- Wattage: 22 W LED
- Lumen: 2200LM
- Color temperature: 4000K
- Detection range: 240° and Max. 50 feet
THIS PACKAGE INCLUDES
SAFETY INFORMATION
This light fixture requires 120-volts AC.
Some codes require installation by a qualified electrician.
- WARNING: Turn the power off at the circuit breaker or fuse. Place tape over the circuit breaker switch and verify power is off at the light fixture.
- WARNING: Risk of fire. Do not aim the lamp heads at a combustible surface within 3 ft. (1 m).
- WARNING: Risk of fire. Keep the lamp heads at least 2 in. (51 mm) from combustible materials.
- CAUTION: Keep the lamp heads 30° below horizontal to avoid water damage and electrical shock
- CAUTION: Burn hazard. Allow the light fixture and the lamp heads to cool before touching.
- CAUTION: Do not cut any wires with factory installed wire connectors or remove the wire connectors.
- NOTICE: Do not connect this light fixture to a dimmer switch or timer.
TOOLS REQUIRED
ELECTRICAL INSTALLATION
-
FIG. l
Place the wall switch to the “OFF” position.
Depending on which type of fuse box you have in your home: -
FIG.2
Place either the main {Master) switch to the “OFF” position, cutting off power to your entire home or turn off the individual switch that provides power to where the fixture will be installed.
OR -
FIG.3
Place either the main (Master) switch to the “OFF” position, cutting off power to the entire home or unscrew the fuse that provides power to where the fixture will be installed.
The motion sensor on this light fixture detects “motion” by the movement of heat across the coverage area. The motion sensor is more sensitive to the movement of heat moving across the coverage area and less sensitive to the movement of heat directly towards it.
Note: Light fixture and sensor should be mounted as shown above when installed (depending upon type of installation).
INSTALLATION
-
WIRING THE LIGHT FIXTURE
Connect the light fixture wires (B) to the junction box wires (E) with easy connector (D).
NOTE: All wiring must be run in accordance with the National Electrical Codethroughconduit or another acceptablemeans.Contact aqualified electrician if there is any question as to the suitability of the system.
White to white
Black to black -
MOUNTING THE LIGHT FIXTURE
Secure the mounting bracket to the junction box using the mounting screws (A) that best fit the junction box.
Secure the light fixture backplate (D) to the mounting bracket using the mounting bolt (B).
Secure the light fixture to the backplate (D) using the mounting bolt (C).
NOTE: Make sure all wires are inside the junction box before attaching the fixture backplate (D) to the junction box. -
CAULKING AROUND THE LIGHT FIXTURE
- CAUTION: Failure to completely caulk around the light
- fixture’s mounting plate could result in water seepage into the light fixture and/or junction box. Caulk around the light fixture and mounting surface with silicone sealant (not included).
-
TURN ON THE CIRCUIT BREAKER AND LIGHT SWITCH.
NOTE: The motion sensor has al minute warm up period before it will detect motion. When first turned on wait for the red LED indicator to start blinking slowly (1 minute).
CONNECTING INSTRUCTIONS
Did you know?
Most modern routers are dual band meaning they support both 2.4 GHz and 5 GHz
channels.
The most common wireless options are
- Mixed: The router will broadcast both 2.4 GHz and 5 GHz simultaneously under the same SSID. The device will choose which to connect to based on multiple variables (congestion, distance to router etc.).
- 2.4 CiHz: Broadcast only on this channel.
- 5 CiHz: Broadcast only on this channel.
- Dual 2.4 and 5 Ci Hz using Separate SSIDs: Router will broadcast both channels and user manually decides which to connect to.
NOTE: THIS DEVICE IS ONLY COMPATIBLE WITH MIXED OR DEDICATED 2.4GHz.
OPERATION
-
Using the Cilobe Suite™ app, put the motion sensor in TEST mode
-
Walk through the coverage area noting where you are when the lights turn on. Also, the LED indicator behind the motion sensor lens will glow blue when motion is detected.
NOTE: The blue LED will turn off30 seconds after all motion has stopped. -
If needed, gently grasp the motion sensor and move it from side to side or up and down to the best position to pick up motion and to view the desired area using the camera.
-
If needed, gently grasp the lamp heads and move them from side to side or up and down to adjust the light coverage area.
-
When testing is complete, use the app to set the controls for the light fixture.
RESET BUTTON
This light can be reset to the original factory settings either by using the
reset button on the bottom of the sensor or through the Globe Suite app
Note: After resetting the light, it may take up to 5 minutes for the light to
be removed from the Cilobe Suite™ app
Reset Button: Use a paper clip to press the RESET button for 15 seconds to
reset the light.
THE “DUALBRITE” FEATURE
Determines the amount of time the light stays on at a dim accent level after
sundown. Switching this setting to “OFF” will make the light a motion light
only, there will be no dim accent light. The light will remain OFF until
motion is detected. Setthe “DUALBRITE” feature to 6 hours or dusk-to-dawn
(sunset to sunrise). will allow the light to remain on at a dim accent level
for the Dual Brite time selected. If the light senses motion during the Dual
Brite stage the light will go to full brightness until motion is not detected.
NOTE: The sensor has feature switches located on the bottom as shown in the picture (G). These feature controls are also located in the Globe Suite App as well. The feature settings chosen in the App will control the light when the light is connected to WiFi service regardless of how the feature sensor settings are programmed. If the light fixture loses WiFi signal the light fixture function will default to the selected feature switch settings on the bottom of the sensor. Once WiFi is re-connected the light will go back to the Cilobe Suite™ App Settings.
CARE AND CLEANING
To prolong the original appearance, clean with clear water and a soft, damp
cloth only.
Do not use paints, solvents, or other chemicals on this light fixture. They
could cause a premature deterioration of the finish. This is not a defect in
the finish and will not be covered by the warranty.
Do not spray with a hose or power washer.
TROUBLE SHOOTING GUIDE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part lSofthe FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-005 (B)/NMB-005 (B)
- FCC Responsible party:
- Globe Electric
- 2264 East 6th Street
- San Bernardino, CA 92410 www.globe-electric.com