Benewake TF02-Pro-W Single Point Ranging LiDAR User Manual

June 3, 2024
Benewake

Benewake logo

TF02-Pro-W Single Point Ranging LiDAR
User Manual

Benewake TF02 Pro W Single Point Ranging LiDAR

PREFACE

Dear users:

Thank you for choosing Benewake products. With the purpose of offering a better operation experience to you, we hereby write this manual for an easier and simpler operation of our product, hoping to better solve the common problems you may meet.
This user manual contains relevant information on product introduction, usage, and maintenance of TF02-Pro-W, covering the product operation introduction and common problem solutions. Please read this manual carefully before using the product Remember the precautions to avoid hazards, and please follow the described steps in the manual when using it.

If you have any problems in the process of usage, you are welcome to contact Benewake at any time for help.

Contact details

Official website: en.benewake.com
TEL : +86-10- 57456983
For technical questions, please contact: support@ benewake.com
Consult sale information or request a brochure, please contact: bwPbenewake.com

Headquarters Address
Benewake (Beijing) Co., Ltd.
No.3030, 3rd Floor, Independent Innovation Building, No.6 Chuangye Road, Haidian District, Beijing, China

Copyright Statement
This User Manual is copyright © of Benewake. Please do not modify, delete or translate the description of this manual contents without official written permission from Benewake.

Disclaimer
As our products are constantly improving and updating, the specifications of TF02-Pro-W are subject to change. Please refer to the official website for the latest version.

OVERVIEW

TF02-Pro-W is a single-point ranging LiDAR specially developed for level detection, based on the ToF (Time of Flight) principle, and provides stable, accurate, and reliable ranging performance by optimizing the optical system and utilizing built-in algorithms, operating range up to 25m. TF02-Pro-W is equipped with a unique dust-removal wiper, which automatically cleans the lens of the front panel of LiDAR regularly to solve the soiling problems, and can maintain the accuracy of ranging detection in heavy dust environment, open configuration interface for user-defined dust removal configuration.

1.1 Technical Specification
Table 1-1 Technical Specification of TF02-Pro-W-

Type Parameters Value

Product
performance| Operating
range| 90% reflectivity, OKlux| 0.1-25m
10% reflectivity, OKlux| 0.1-12m
90% reflectivity, 100Klux| 0.1-25m
• 10% reflectivity, 100Klux| 0.1-12m
Accu race| ±6cm (0.1m-6m) 1 ±1% (6m-25m)
Distance resolution’| 1cm
Frame rate| 1Hz-1000Hz
( adjustable, default 100Hz)
Repeatability’| la: <2cm
(0.1m-25m@90% reflectivity )
Ambient light immunity| 100Klux
Enclosure rating| IP5X
Optical
parameters| Photobiological safety| Classl (IEC60825)
Central wavelength| 850nm
Light source| VCSEL
FoV 3| 3°
Electrical
parameters| Supply voltage| DC 5V
Average current| .S400mA
Power consumption| -2W
Peak current| 1A
Others| Dimension| 85mm x 59mmx 43mm (Lx HxW)
Housing| PC/ABS
Operating temperature| -20ºC-60ºC
Storage temperature| -30ºC-80ºC
Weight| 90g (with cables)
Cable length| 120cm

Note

  1. The detection is measured with the standard whiteboard (90% reflectivity).
  2. The frame rate can be adjusted. The default value is lO0Hz and the maximum value is 1000Hz, the customized frame rate should be calculated by the formula: 2000/n (n is an integer with ≥ 2).
  3. The angle is a theoretical value, and the actual angle value has some deviation.

1.2 Maintenance and Cleaning

  • Before switching on, please check if the exposed window mirror is clean, and clean it promptly if it is dirty.
  • After using the device, check the optics. If it is contaminated, please clean it promptly.
  • The optics should be cleaned regularly if the device be operated in a severe environment for a long time.
  • Before regular cleaning, please disconnect the power. Using a soft cloth to gently wipe the window in the same direction when the device is not operating, to avoid repeated wiping and damage to the window mirror.
  • Do not remove the dust-removal wiper, which may cause equipment failure. If the dust-removal wiper is abnormal, please contact [email protected].
  • When the steering shaft is blocked by dust for a long time, the steering shaft may be damaged due to increased resistance. Please clean the steering shaft regularly.
  • If you require deep cleaning of internal optics, please contact [email protected] to offer professional advice.

1.3 Appearance and Structure
The appearance and dimensions ofTF02-Pro-W are shown in Figure 1-1 and Figure 1-2.

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
1

TF02-Pro-W is recommended to use M2.5 round Phillips screws for installation. Please remove the protective film of the optical lens before use. The lens of the front panel of  LiDAR cannot be covered. Please keep it clean. The surface of the optical lens is the ranging zero of LiDAR.
The detection angle ofTF02-Pro-W is 3. At different distances, the size of the light spot, namely the edge length of the detection range, is different, as shown in Figure 1-3. The side length of the detection range at different distances (the detection range is a square), as shown in Table 1-2.

Note
The side length of the target object generally should be larger than the size of the TF02-Pro-W light spot; if the side length of the detected object is smaller than the size of the light spot, the output (Distance) from TF02-Pro-W will be a value between the actual distance values of the two objects.

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
2

Distance (m) 1 2 3 4 5 6 7 8 9 20 15 20 22
Spot Sze (cm) 5 10 16 21 26 31 37 42 47 52 79 105 115

1.4 Storage

  • The device should be stored at -30°C to 80C with a relative humidity < 60% and ventilation free from corrosive gases.

  • Before storage, please make sure that all connections are disconnected or dust covers are inserted or covered to ensure cleanliness.
    If the storage time is over three months, please carry out a working test before using, to ensure that the device can be used in normal condition.

  • For ensuring product performance, do not open the product shell or remove the IR-pass filter.

INTERFACE

2.1 Description Of Wiring Sequence
The external tail cable of TF02-Pro-W has no connector by default, the wiring sequence is shown in Table 2-1.
Table 2-1 The Function Description of Each Wire

Cable Color Function Comment
Red VCC Power supply
Black GND Ground
White RXD/SDA Receiving/Data
Green TXD/SCL Transmitting/Clock

Electrical Characteristics

TF02-Pro-W has no overvoltage and reverse polarity protection, so please make sure that the connection and power supply are normal. The electrical characteristics are shown in Table 2-2.
Table 2-2 Main Electrical Parameters of TF02-Pro-W Parameter| Value
---|---
Supply Voltage| DC 4.8V-5.5V
Average Current| ≤ 400mA
Peak Current| lA
Average Power Consumption| ≤ 2W
Communication Level| LITTLE (0-3.3V)

COMMUNICATION PROTOCOL

3.1 Serial Communication Protocol

TF02-Pro-W adopts the serial port data communication protocol, as given in Table 3-1.
Table 3-1 Data Communication ProtocolCommunication interface| UART
---|---
Default baud rate| 115200
Data bit| 8
Stop bit| 1
Parity check| None

3.2 Serial Communication Data Format

TFO2-Pro-Wis available with two formats of data output, namely, the standard data output format and the character string data format, both of which are switchable with a command.

3.2.1 Standard data output format
The serial data format of TF02-Pro-W is shown in Table 3-2, the data is hexadecimal, and each data frame contains 9 bytes, including the distance value, signal strength, temperature of the chip, and data check byte (Checksum).
Table 3-2 Data Format and Code ExplanationByte0-1| Byte2| Byte3| Byte4| Byte5| Byte6| Byte7| Byte8
---|---|---|---|---|---|---|---
0x59 59| Dist_L| Dist_H| Strength_L| Strength_H| Temp_L| Temp_H| Checksum
Byte0| 0x59, frame header, same for each frame
Byte1| 0x59, frame header, same for each frame
Byte2| Dist_L distance value low 8 bits
Byte3| Dist_H distance value high 8 bits
Byte4| Strength_L low 8 bits
Byte5| Strength_H high 8 bits
Byte6| Temp low 8 bits
Byte7| Temp high 8 bits
Byte8| The checksum is the lower 8 bits of the cumulative sum of the number of the first 8 bytes

  • Dist(Distance): The detection distance value with TF02-Pro-W, default unit is cm.
  • Strength: The signal strength, the default output is between 0 and 65535. When the distance measuring gear is certain, the farther the distance is measured, the lower the signal intensity; the lower the reflectivity of the target, the lower the signal intensity
  • Temp(Temperature): The chip temperature, temperature(°C) = Temp / 8 -256.

3.2.2 Character string data format
The data output is in the format of a character string and its unit is m(meter). For example, if the measurement distance is 1.21m, the string 1.21 will be output, followed by the escape character \r\n.
3.3 I²C Communication Protocol
TF02-Pro-W supports PC data communication interface, as shown in the table below:
Table 3-3 TF02-Pro-W !2C Data Communication ProtocolCommunication Interface| I²C
---|---
Max transmission rate| 400kbps
Master/Slave mode| Slave mode
Default Address| 0x10
Address Range| 0x01~0x7F

3.4 Timing Sequence Description of I?C

Different from the serial mode, the 12C communication is initiated by the master. TFO2-Pro-W can only send and receive data passively, as a slave. After sending the command from master to slave, one needs to wait for a period for the command to be processed. Then read the response of LIDAR, the suggested waiting period is 100ms. Data is detailed in  Table 3-4.

Table 3-4 Timing Sequence of PC

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
3

PARAMETER CONFIGURATION

In order to allow TFO2-Pro-W to solve your problems more flexibly, the function of the user-defined configuration of product parameters is opened. Users can modify the original parameters of the product by sending relevant instructions, such as output data format, frame rate, dust wiper parameters, etc.
Please modify the product configuration depending on your actual demands. Do not frequently try irrelevant commands to prevent the incorrect sending of commands which may cause unnecessary loss. Please make sure to make the configuration as the commands listed herein. Do not send unstated commands.

4.1 Command Convention
For the configuration instructions in this document, see the following command convention:

  • Multi-byte data or command frame is transmitted in little-endian format. For example:
    set the frame rate to 1000Hz, as shown in Table 4-1. The decimal number 1000 can be converted to 0x03E8 in hexadecimal. Then it will be saved in the data or command frame as:
    Ox5A 0x06 0x03 0xE8 0x03 0x4E

  • Command: data instruction frame sent from PC to LIDAR.

  • Response: data frame sent by LIDAR to host computer or other terminals.

Before setting the relevant parameters of TF02-Pro-W, the user needs to establish the connection between TF02-Pro-W and PC at first. Users can send the relevant configuration-related instructions to the product via TFO2-Pro-W PC software or other serial port debugging software. All commands are compatible with both UART mode and ’C mode.

4.2 Configuration Commands
4.2.1 General parameters configuration
The general parameters configuration command is shown in Table 4-1. After the parameters configuration, send the saving settings command to save the configuration, otherwise the settings will not take effect.

Parameters Firmware version| Command 5A 04 01 5F| Response
5A 07 01 V1 V2 V3 SU’| Remark Version V3.V2.V1
---|---|---|---
System reset 2| 5A 04 02 60| 5A 05 02 00 60| Succeeded
5A 05 02 01 61| Failed
Frame rate’| 5A 06 03 LLHH SU| 5A 06 03 LL HH SU| 1-1000Hz, default 100Hz
Trigger detection| 5A 04 04 62| Date frame| After setting the frame rate to 0, detection can be triggered with this command
Output format| 5A 05 05 01 65| 5A 05 05 01 65| Standard 9 bytes(cm)
5A 05 05 02 66| 5A 05 05 02 66| Character string(m)
5A 05 05 06 6A| 5A 05 05 06 6A| Standard 9 bytes (mm)
Baud rate`| 5A 08 06 H1 H2 H3 H4 SU| 5A 08 06 H1 H2 H3 H4 SU| Default 115200; E.g. 256000(DEC)=3E800(HEX) ,
H 1=00,H2=E8,H3=03,H4=00
Enable/Disable output| 5A 05 07 00 66| 5A 05 07 00 66| Disable data output
5A 05 07 01 67| 5A 05 07 01 67| Enable data output
Communication interface setup| 5A 05 OA MODE SU| /| 00 (UART), default; 01 (PC)
Modify 12C_slave_addr| 5A 05 OBADDR SU| 5A 05 OB ADDR SU| Modify PC_slave_addr,
default Ox10
Obtain data frame| 5A 05 00 01 60| Data Frame (9bytes-cm)| Only works in 12C mode
5A 05 00 06 65| •
Data Frame (9bytes-mm)
Strength
threshold and
distance under
threshold| 5A 07 22 XX LL HH SU| 5A 07 22 XX LL HH SU| Strength Threshold=60, Distance under
threshold=4500.
E.g. When strength is below 60, make distance output 4500cm.
XX=60/10=6(DEC)=06(HEX)  4500(DEC)=1194(HEX)
LL=94, HH=11
Low power
consumption
mode| 5A 06 35 OX 00 SU| 5A 06 35 OX 00 SU| Range of X(HEX) is 0—A:
X > 0, enable low power
consumption mode;
X=0, disable low power
consumption mode, default
Restore to factory settings| 5A 04 10 6E| 5A 05 10 00 6F| Succeeded
5A 05 10 01 70| Failed
Save settings| 5A 04 11 6F| 5A 05 11 00 70| Succeeded
 |  | 5A 05 11 01 71| Failed

Warning

  1. SU is a checksum, checksum is disabled by default.
  2. Please keep the power on and wait after sending the system reset command, otherwise, the settings will not take effect.
  3. The customized frame rate should be calculated by the formula: 2000/n (n is an integer with ≥ 2).
  4. The following baud rates are supported: 9600, 14400, 19200, 38400, 56000, 57600, 115200, 128000, 230400, 256000, 460800, 512000, 750000, 921600. When setting a high update rate, a high baud rate is recommended to ensure data security. After sending the baud rate command, keep the power on and switch to the target baud rate before sending the save setting command, it will be effective in this way.
  5. After the parameters configuration, send the saving settings command to save the configuration, otherwise, the settings will not take effect.

4.2.2 Wiper working and configuration
4.2.2.1 Wiper working

The dust-removal wiper works in a fixed period, which is the customer’s default working mode.
For every 24 hours, there will be a total of six dust-removal operations, each dust-removal operation is driven by the LiDAR servo, and the wiper swings back and forth one time.  And TF02-Pro-W will also perform a dust-removal operation once after each power-on.
In addition, customers can control the LiDAR immediately by sending a command for dust­ removal, modifying the wiper swing times and saving the settings. During the dust removal operation, the LiDAR does not measure and output data.
The wiper stops at position A when it does not work, and moves from position A to position B during operation, then returns to position A, the initial and termination positions are shown in Figure 4-1.

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
4

4.2.2.2 Parameters configuration of wiper
Configure the wiper parameters in the following three steps:

  1. Enter into configuration mode:
    Command: AA 55 F0 00 010000 02.
    Response: AA 55 FO 00 01 00 00 02, which means successful transmission.

  2. Configuration of product parameters:
    The configuration command is shown in Table 4-2.

  3. Exit configuration mode:
    Command: AA 55 FO 00 00 00 00 02.
    Response: AA 55 FO 00 00 00 00 02, which means successful transmission.
    For wiper dust-removal working, customers can customize the dust-removal cycle, and wiper round trip times, or immediately start the wiper, the commands are shown in Table 4-2.  Do not send instructions not declared in the user manual.

Table 4-2 Wiper Parameter Configuration and Description f TF02-Pro-W

Number Parameters Command Remark
1 Start the wiper AA 55 FO 00 00 00 00 BO Use this command to start the

wiper at any time during the default mode
2| Modify dust
removal cycle| AA 55 FO 00 EE FF 00 B2| EE: dust removal cycle (Unit: min) high 8 bits, FF: dust removal cycle low 8 bits Note: Cycle can’t be less than min
3| Modify the
number of wiper round trips| AA 55 FO 00 EE 00 00 B3| EE: The number of round trips of the wiper during a dust removal cycle
Note: No more than 10 round trips per cycle

Warning

  1. The wiper configuration has to be performed in a strict sequence.2
  2. If the parameter of the dust removal cycle is wrong, feedback will be “AA 55 F0 03 EE FF 00 B2. It is suggested that the dust removal interval should be more than 30 minutes under the condition of high temperature (ambient temperature > 40C).
  3. If the number of wiper round trips is wrong, feedback will be “AA 55 F0 03 EE 00 00 B3. No more than 10 round trips per cycle.

QUICK TEST GUIDE

5.1 Tools Required for Test
Table 5-1 The required tools for product test

| | Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
7| |
---|---|---|---|---
TF02-Pro-W| TTL-USB
Converter| USB Cable| PC| BW_TFDS
Software

5.2 Test Procedures

  1. Download the test software
    Download the latest version of BW_ TFDS from http://en.benewake.com/support.
    The introduction of BW_TFDS software is shown in Attachment-1 BW_TFDS software.

  2. Connection of the hardware
    Connect “TF02-Pro-W”, “TTL – USB board” and “USB cable”. Make sure there is no loose connection. Then connect “The USB cable” to “PC”. As shown in Figure 5-1.
    Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
10

  3. Connection to the software
    Run the BW_ TFDS software, select “CD TF02-Pro” and select the automatically recognized communication port (here it is “2 COM9”), choose the right baud rate (here it is “®
    115200″), as shown in Figure 5-2.

  4. Data output
    Then click “CONNECT”. Upon successful connection, the continuous images of the output data will be displayed in the area “@ TIMELINE CHART”. Besides, the real-time data of the current measure distance (Dist), effective data points per second {Effective Points), and signal strength (Strength) will be displayed in the area “S REAL TIME DATA” .

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
11

Note

  1. Please shut down any anti-virus software before uncompressing the PC software. Otherwise, maybe the software is deleted as a virus. The software is only runnable under  Windows.
  2. If no data is available in the area “@TIME LINE CHART”, please check the line connection and line sequence. When TF02-Pro-W is successfully powered on, there will be a  red indicator light inside the transmitting lens viewing from the front.
  3. The value of distance output Dist may vary with the output unit, which is cm by default. If the unit of distance is changed to the unit-mm with a specific command, the PC  software will be unable to identify it, and so the unit of “@TIME LINE CHART” will still be cm. For example, the actual TF02-Pro-W measurement is 1m, the distance value of TF02-Pro-W is 1000 in mm, and the value read by the PC software also is 1000, but the unit will not change and still display cm.

Firmware Update

TF02-Pro-W supports the firmware upgrade. When the user’s product cannot satisfy the current application requirements and Benewake official website has relevant firmware
upgrades, the user may upgrade the product firmware via the Updater_BENEWAKE software. Please contact us to get the Updater.
The tools for the firmware upgrade of TF02-Pro-W are mostly the same as QUICK TEST GUIDE, which requires one TTL-USB board to connect the TF02-Pro with PC. The  upgrade process is as follows:

  1. Run Updater_BENEWAKE.exe, Select right port, here is “COM9”. Input the right baud rate in “2 115200 and click “3 CONNECT” to connect the TF02-Pro-W with the
    software. As shown in Figure 6-1.
    Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
12

  2. Click”@ Open Bin” to choose the updating firmware, the message “@Read bin done” will be displayed after the file is uploaded. Then click “s Download Bin” to start upgrading. As shown in Figure 6-2.
    Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
13

  3. Check the status of the progress bar, 100% indicates that the upgrade is complete, and appear “7Jump done”.
    Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
14

Q&A

Q1: Is TFO2-Pro-W available with other power supply voltage?

A1: Sorry, it is not available for the time being. The standard power supply of TF02-Pro-W is 4.8V~5.5V. If you have any further requirements, please contact our sales to consult a customization design matter, or you can obtain information about TF02-Pro-W-485, which supports a 7V~30V power supply.

Q2: Is it possible to change the FoV?

A2: Hello, this demand needs to be customized, please contact our sales to consult a customization design matter.

Q3: How far can the TF02-Pro-W serial port version be transmitted? Can | extend the cable directly to increase the transmission distance?

A3: Hello, the effective transmission distance of TF02-Pro-W serial port data transmission is about 2m. If you need long-distance data transmission, it is recommended to convert the serial communication to another communication such as RS-485, and then extend the data line for transmission.

Q4: How long is the life of a product?

A4: The warranty period is one year and can be used for more than 3 years under normal circumstances, the life of the servo is larger than the product itself, and the life of the wiper is about 3 years under default mode (work every 4 hours), the wiper is made of rubber and it’s a replaceable accessory.

Q5: Can TF02-Pro-W support the RS-485 interface, analog signals output, and Modbus protocol?

AS: TF02-Pro-W currently does not support interfaces other than UART and IIC. For the RS-485 communication interface and Modbus protocol, refer to TF02-Pro-W-485. If there are related requirements, please contact our sales to consult a customization design matter.

Attachment-1 BW TFDS software

BW_ TFDS software only supports the Windows operating system. It is suitable for any products of TF series, but the output of those products is limited to the serial port communication protocol. Detailed operations are as below.

Benewake TF02 Pro W Single Point Ranging LiDAR - Figure
15

  1. Product Type/Serial Port Control Zone [SETTINGS]
    Product: choose a product model, such as TF02-Pro in this paper
    COM: select the right serial port number corresponding to the LiDAR.
    Baud rate: choose the baud rate of LiDAR, which is set to 115200 as default for BENEWAKE.
    CONNECT/DISCONNECT: Click the [CONNECT] button to establish the connection with LiDAR.
    Click the [DISCONNECT] button to terminate the connection.

  2. Function Zone [FUNCTION]
    Frame rate: choose frame rate from the drop box, the setting will be made immediately, and the change is viewed in [@Effective Points].
    Output Control: enable/disable the data output of Li DAR, default “on”.
    SAVE SETTING: save the frame rate and output setting. Click “SAVE SETTING” to save the configuration after setting, otherwise, the settings will not take effect.
    RESTORE DEFAULT SETTING: restore the factory default Settings.
    Drawing/Pt: upon receipt of every N frame, the software will draw one point on the chart [4] the average of the N data. N can be modified depending upon the actual requirement (the value is preferable to be 210 to prevent the PC software from lagging). After entering the value, press the “Enter” key on the keyboard to enable the setting.  Draw AMP: the software will draw the curve of signal strength on the chart [4], taking effect immediately after the button is selected. FREEZE/CLEAR: After clicking  [FREEZE], the timeline chart in zone [4] will stop updating. On clicking [CLEAR], the plotted curve in [4] will be cleared.

  3. Data Recording Zone [DATA RECORDING]
    Input the name of the data file in the textbox. Press [RECORD]
    button to start recording data and click the [FINISHED] button to stop recording. Click the [FOLDER] button to open the folder where the data file is saved.

  4. Time Line Chart Zone [TIME LINE CHART]
    The PC software will draw the continuous distance measurement curves based on the received data, where y-coordinates represent the current distance data while x- coordinates represent effective data.

  5. CUSTOM COMMAND ZONE [CUSTOM COMMAND]
    Command: Input the commands in hexadecimal format in the text box and click the [SEND] button above to send the command.

  6. Real-time Data Display Zone [REAL-TIME DATA]
    Dist: Distance, unit: cm by default.
    Strength: the signal strength, values are between 0 and 65535. Effective Points (per sec): indicates effective points refreshed by TF per second (equals to the frame rate).

Benewake logo