1. General information
The chapter “Operation” is intended for appliance users and qualified contractors.
The chapter “Installation” is intended for qualified contractors.
Note  Read these instructions carefully before using the appliance and retain them for future reference. Pass on the instructions to a new user if required.

Safety instructions

1.1.1 Structure of safety instructions
 KEYWORD Type of risk Here, possible consequences are listed that may result from failure to observe the safety instructions.

Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk

Symbol Type of risk
**** Burns (burns, scalding)

1.1.3 Keywords

KEYWORD Meaning
DANGER Failure to observe this information will result in serious injury or

death.
WARNING| Failure to observe this information may result in serious injury or death.
CAUTION| Failure to observe this information may result in non-serious or minor injury.

1.2 Other symbols in this documentation
Note
General information is identified by the adjacent symbol. f Read these texts carefully.

Symbol Meaning
**** Material losses (appliance damage, consequential losses and

environmental pollution)
| Appliance disposal

This symbol indicates that you have to do something. The action you need to take is described step by step.
1.3 Information on the appliance
Connections

Symbol Meaning
 Supply / Inlet / Flow
Drain / Outlet / Return
Heat pump
Central heating

1.4 Units of measurement
Note  All measurements are given in mm unless stated otherwise.

Safety

2.1 Intended use
This appliance is designed to extend the operating time of the heat generator and to bridge power-OFF periods. The heat pump buffer cylinder also provides hydraulic separation of the flow rates in the heat pump circuit and the heating circuit.
Observation of these instructions and of instructions for any accessories and other system components used is also part of the correct use of this appliance.
Any other use beyond that described shall be deemed inappropriate. Using the appliance for heating fluids other than water or for water supplemented with chemicals, such as brine, is also deemed inappropriate.

Appliance description

The steel cylinder with directly applied foam insulation is equipped with a protective cover, connections for ventilation and draining, and a sensor pipe. The hydraulic connections are routed through the top.

Troubleshooting

Call your qualified contractor.
To facilitate and speed up your inquiry, please provide the serial number from the type plate (000000-0000-000000):
Safety
Only a qualified contractor should carry out the installation, commissioning, maintenance and repair of the appliance.
5.1 General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
5.2 Instructions, standards, and regulations
Note Observe all applicable national and regional regulations and instructions.

Appliance description

6.1 Standard delivery
The following are delivered with the appliance: – 3 adjustable feet

Preparations

7.1 Installation site

  • Always  install the appliance in a room free from the risk of frost.
  • Ensure the floor has sufficient load-bearing capacity and evenness (see chapter “Specification / Data table”).
  • Observe the room height and height when tilted (see chapter “Specification / Data table”).

Minimum clearances

Installation

8.1 Positioning the equipment
Use the adjustable feet provided to compensate for any unevenness in the floor.

  • Undo the 3 screws from the non-returnable pallet
  • Tilt the appliance and screw the 3 adjustable feet provided into the appliance.
  • Lift the appliance off the pallet.
    • When installing, observe minimum clearances (see chapter “Preparations / Installation site”).

8.2 Heating water connection
Material losses
Carry out all water connection and installation work in accordance with regulations.

  • Observe the heat pump operating and installation instructions when making the heating water connection.
  • Connect the hydraulic connections with flat gaskets.

Oxygen diffusion

**Material losses
Avoid open heating systems and plastic pipes in underfloor heating systems which are permeable to oxygen.
In underfloor heating systems with plastic pipes that are permeable to oxygen and in open vented heating systems, oxygen diffusion may lead to corrosion on the steel components of the heating system (e.g. on the indirect coil of the DHW cylinder, on buffer cylinders, steel heating elements or steel pipes).
Material losses**
The products of corrosion (e.g. rusty sludge) can settle in the heating system components and can result in a lower output or fault shutdowns due to reduced cross-sections.

Commissioning

9.1 Initial start-up

  • Fill and bleed the appliance (see chapter “Specification / Dimensions and connections”).
  • Carry out a tightness check.

9.1.1 Appliance handover

  • Explain the function of the appliance to users and familiarise them with its operation.
  • Make the user aware of potential dangers, especially the risk of scalding.
  • Hand over these instructions

9.2 Recommissioning
See chapter “Commissioning / Initial start-up”.

Shutdown

  • Drain the appliance. See chapter “Maintenance / Draining the appliance”.

Maintenance

No special maintenance is required for the appliance. A regular visual check is sufficient.
11.1 Draining the appliance
WARNING Burns Hot water may escape during draining.
If the appliance needs to be drained for maintenance or to protect the whole installation when there is a risk of frost, proceed as follows:
Drain the appliance using the appliance drain connection (see chapter “Specification / Dimensions and connections”).
www.stiebel-eltron.com

Specification

12.1 Dimensions and connections

| | | SBP 100 classic
---|---|---|---
d03| Heat pump flow optional| Male thread| G 1 1/4
d04| Heat pump return optional| Male thread| G 1 1/4
e03| Heating flow optional| Male thread| G 1 1/4
e04| Heating return optional| Male thread| G 1 1/4
d46| Ventilation| mm|
d47| Drain| Female thread| G 1/2
h02| Sensor heat pump return| Diameter| 14

Optional connections

12.2 Details on energy consumption

| SBP 100 classic
---|---
| 235200
Manufacturer| STIEBEL ELTRON
Model-identification of the supplier| SBP 100 classic
Energy efficiency class| C
standing loss S………………w| 50
storage volume V| 99

12.3 Data table

Energy data Energy efficiency class Standby energy consumption/24 h at 65 °C Hydraulic data Rated capacity Application limits, Max. permissible pressure Test pressure Max. permissible temperature Dimensions Height Width Depth Weights Weight (wet) Weight (dry)

| | SBP 100 classic
---|---|---
| KWH| 235200
Energy data| C
Energy efficiency class| 1,2
Standby energy consumption/24 h at 65 °C| 1| 100
Hydraulic data| kWh| 0,3
Rated capacity| l| 0,45
Application limits| MPa| 95
Max. permissible pressure| MPa| 877
Test pressure| °C| 510
Max. permissible temperature| mm| 510
Dimensions| mm| 120
Height| mm| 21
Width| kg| 510
Depth| kg| 510
Weights| kg|
Weight (wet)…………………………………………kg| 120
Weight (dry)kg,……………………………………………… kg| 21

Guarantee

The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, a guarantee can only be issued by those subsidiaries. Such a guarantee is only granted if the subsidiary has issued its own terms of the guarantee. No other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in countries where we have no subsidiary to sell our products. This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations.
www.stiebel-eltron.com

Deutschland
STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße 33 | 37603 Holzminden
Tel. 05531 702-0 | Fax 05531 702-480
info@stiebel-eltron.de
www.stiebel-eltron.de
United Kingdom and Ireland
STIEBEL ELTRON UK Ltd.
Unit 12 Stadiu
m Court
Stadium Road | CH62 3RP Bromborough
Tel. 0151 346-2300 | Fax 0151 334-2913
info@stiebel-eltron.co.uk
www.stiebel-eltron.co.uk

Australia
STIEBEL ELTRON Australia Pty. Ltd.
294 Salmon Street | Port Melbourne VIC 3207
Tel. 03 9645-1833 | Fax 03 9644-5091
info@stiebel-eltron.com.au
www.stiebel-eltron.com.au| Netherlands
STIEBEL ELTRON Nederland B.V.
Daviottenweg 36 | 5222 BH ‘s-Hertogenbosch
Tel. 073 623-0000 | Fax 073 623-1141
info@stiebel-eltron.nl
www.stiebel-eltron.nl
---|---
Austria
STIEBEL ELTRON Ges.m.b.H.
Gewerbegebiet Neubau-Nord
Margaritenstraße 4 A | 4063 Hörsching
Tel. 07221 74600-0 | Fax 07221 74600-42
info@stiebel-eltron.at
www.stiebel-eltron.at| New Zealand
Stiebel Eltron NZ Limited
61 Barrys Point Road | Auckland 0622
Tel. +64 9486 2221
info@stiebel-eltron.co.nz
www.stiebel-eltron.co.nz
Belgium
STIEBEL ELTRON bvba/sprl
‘t Hofveld 6 – D1 | 1702 Groot-Bijgaarden
Tel. 02 42322-22 | Fax 02 42322-12
info@stiebel-eltron.be
www.stiebel-eltron.be| Poland
STIEBEL ELTRON Polska Sp. z O.O.
ul. Działkowa 2 | 02-234 Warszawa
Tel. 022 60920-30 | Fax 022 60920-29
biuro@stiebel-eltron.pl
www.stiebel-eltron.pl
China
STIEBEL ELTRON (Tianjin) Electric Appliance
Co., Ltd.
Plant C3, XEDA International Industry City
Xiqing Economic Development Area
300385 Tianjin
Tel. 022 8396 2077 | Fax 022 8396 2075
info@stiebeleltron.cn
www.stiebeleltron.cn| Russia
STIEBEL ELTRON LLC RUSSIA
Urzhumskaya street 4,
building 2 | 129343 Moscow
Tel. +7 495 125 0 125
info@stiebel-eltron.ru
www.stiebel-eltron.ru
Czech Republic
STIEBEL ELTRON spol. s r.o.
Dopraváků 749/3 | 184 00 Praha 8
Tel. 251116-111 | Fax 235512-122
info@stiebel-eltron.cz
www.stiebel-eltron.cz| Slovakia
STIEBEL ELTRON Slovakia, s.r.o.
Hlavná 1 | 058 01 Poprad
Tel. 052 7127-125 | Fax 052 7127-148
info@stiebel-eltron.sk
www.stiebel-eltron.sk
Finland
STIEBEL ELTRON OY
Kapinakuja 1 | 04600 Mäntsälä
Tel. 020 720-9988
info@stiebel-eltron.fi
www.stiebel-eltron.fi| South Africa
STIEBEL ELTRON Southern Africa (PTY) Ltd
30 Archimedes Road
Wendywood
Johannesburg, 2090
Tel. +27 10 001 85 47
info@stiebel-eltron.co.za
www.stiebel-eltron.co.za
France
STIEBEL ELTRON SAS
7-9, rue des Selliers
B.P 85107 | 57073 Metz-Cédex 3
Tel. 0387 7438-88 | Fax 0387 7468-26
info@stiebel-eltron.fr
www.stiebel-eltron.fr| Switzerland
STIEBEL ELTRON AG
Industrie West
Gass 8 | 5242 Lupfig
Tel. 056 4640-500 | Fax 056 4640-501
info@stiebel-eltron.ch
www.stiebel-eltron.ch
Hungary
STIEBEL ELTRON Kft.
Gyár u. 2 | 2040 Budaörs
Tel. 01 250-6055 | Fax 01 368-8097
info@stiebel-eltron.hu
www.stiebel-eltron.hu| Thailand
STIEBEL ELTRON Asia Ltd.
469 Moo 2 Tambol Klong-Jik
Amphur Bangpa-In | 13160 Ayutthaya
Tel. 035 220088 | Fax 035 221188
info@stiebeleltronasia.com
www.stiebeleltronasia.com
Japan
NIHON STIEBEL Co. Ltd.
Kowa Kawasaki Nishiguchi Building 8F
66-2 Horikawa-Cho
Saiwai-Ku | 212-0013 Kawasaki
Tel. 044 540-3200 | Fax 044 540-3210
info@nihonstiebel.co.jp
www.nihonstiebel.co.jp| United States of America
STIEBEL ELTRON, Inc.
17 West Street | 01088 West Hatfield MA
Tel. 0413 247-3380 | Fax 0413 247-3369
info@stiebel-eltron-usa.com
www.stiebel-eltron-usa.com

United States of America
STIEBEL ELTRON, Inc.
17 West Street | 01088 West Hatfield MA
Tel. 0413 247-3380 | Fax 0413 247-3369
info@stiebel-eltron-usa.com
www.stiebel-Eltron-usa.com ****

Subject to errors and technical changes!
Stand 9646

Documents / Resources

| STIEBEL ELTRON SBP 100 Classic Buffer Cylinder [pdf] Instruction Manual
SBP 100 Classic Buffer Cylinder, SBP 100 Classic, Buffer Cylinder, Cylinder
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

STIEBEL ELTRON User Manuals

Related Manuals