TRANSPORTER 1699-001 Height Staff Instruction Manual
- June 1, 2024
- TRANSPORTER
Table of Contents
TRANSPORTER 1699-001 Height Staff
Product Using Instruction
- Instructions
- After removing the staff from the storage bag rotate the measuring arm up and over the top of the staff and lock into position with the thumb catch.
- Thumb catch (locked)
- A series of images show the thumb catch at different stages: unlocked, in the process of locking and fully locked.
- Extend each section fully starting with the top section so that the lock snaps into place.
- Snap lock (locked)
- An image shows the snap lock mechanism in a locked position.
- Check that the staff is upright using the level on the staff (ensure the bubble is inside the circle).
- Level
- An image illustrates a level with the bubble centred, indicating the staff is level.
- Un-Level
- An image illustrates a level with the bubble off-centre, indicating the staff is not level.
- Slide the staff down into the lower section so that the end of the rotating arm touches the point to be measured.
- The height measurement can be taken from the top of the lower section, one side metric and the other imperial.
- Read Imperial from here
- An image shows where the imperial measurements can be read on the staff.
- Read Metric from here
- An image shows where the metric measurements can be read by the staff.
- To lower staff push in the snap lock and slide section down at the same time.
- Important Note
- Beware of overhead obstructions and power lines during use.
Specifications
Feature | Description |
---|---|
Thumb Catch | Locks the measuring arm in position |
Snap Lock | Secures the extended sections of the staff |
Level Indicator | Ensures the staff is perfectly upright for accurate |
measurement
Measurement Scales| Dual-sided with metric and imperial units
FAQs
How do I lock the measuring arm in place?
Rotate the measuring arm over the top of the staff and secure it with the thumb catch.
What should I do if the sections won't extend?
Ensure each section is fully extended starting from the top so that the lock snaps into place.
How can I ensure the staff is level?
Use the built-in level on the staff, making sure the bubble is centred within the circle.
Where do I read the imperial and metric measurements?
Imperial measurements can be read from the top of the lower section, and metric measurements from the same location on the opposite side.
What is the correct way to lower the staff?
Press in the snap lock and simultaneously slide the section down to lower the staff.
What should I be cautious of when using the height staff?
Always be aware of overhead obstructions and power lines when using the height staff.
Operation
Operation Guide for Height Staff 1699-001
- After removing the staff from the storage bag rotate the measuring arm up and over the top of the staff and lock into position with the thumb catch.
- Extend each section fully starting with the top section so that the lock snaps into place
- Check that the staff is upright using the level on the staff (ensure the bubble is inside the circle)
- Slide the staff down into the lower section so that the end of the rotating arm touches the point to be measured. The height measurement can be taken from the top of the lower section, one side metric the other imperial
- To lower staff push in the snap lock and slide section down at the same time.
Important note: Beware of overhead obstructions and power lines during use.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>