Sunco DL_SL3_NL-WH-2760K 3 Inch LED Slim Night Light User Manual
- June 1, 2024
- SUNCO
Table of Contents
Sunco DL_SL3_NL-WH-2760K 3 Inch LED Slim Night Light
Whats in the Box?
Slim Downlight
Why Plastic Junction Boxes?
At Sunco, our commitment to safety and reliability is at the core of our
lighting solutions, ensuring your peace of mind.
- Plastic’s corrosion resistance ensures longer product lifespans with minimal maintenance.
- Plastic junction boxes are non-conductive, significantly helping prevent potential fires.
- Plastic junction boxes feature smooth edges, minimizing accidental cuts.
Box Content
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- Professional installation required. Safety gear recommended.
- Abide by regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before insatalling. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
- Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Use safety precautions and abide by regional and local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices.
FCC NOTE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
Installation Guide
-
STEP 1
- Turn off circuit breaker before installation.
- Cut out 3.5” housing size on Installation Template, then tape onto ceiling in desired location.
- Cut ceiling hole using Installation Template as a guide.
-
STEP 2
Open junction box and remove appropriate knockout. -
STEP 3
- Thread cable connector through knockout, secure wires with screws, attach nut on opposite side, & connect wires with wire nuts (Black to Black – Live; White to White – Neutral).
- Tuck wires in box & close cover.
-
STEP 4
Note: This step applies exclusively to the Selectable Slims.
Adjust CCT Switch for 5 color temps. Insert junction box through ceiling hole. Secure to studs for new construction; no need for remodel. -
STEP 5
- Attach fixture to junction box using connector as shown on image (1).
- Tighten connector by hand (2).
-
STEP 6
- Push up spring clips and insert fixture into ceiling.
- Turn on circuit breaker and test light.
Product Details
Recommended Dimmers
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | MACL-153M-WH |
LUTRON | PD-6WCL-WH |
LUTRON | AYCL-153P-WH |
LUTRON | DVCL-153P-WH |
LEVITON | D26HD-2RW |
KASA SMART | HS220 |
KASA SMART | HS220P3 |
- Voltage 120V
- Wattage 6W
- CCT 2700K-6000K
- Beam Angle 90°
- Weight 0.44lbs
- Efficacy 83.33lm/w
- Dimmable Yes
- Average Lifetime 50000 hrs
- Lumens 500LM
- Moisture Rating Damp
- CRI 80+
- Usage Indoor
- Amps Indoor
- Warranty 7 Years
Common Troubleshooting
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting. An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more.
Customer Support
Warranty Policy
- This product is covered by our industry leading 7 year warranty.
- It gets even better – scan the QR code for 2 extra years of protection!
30 Day Return Policy
- At Sunco, we value our customers & stand by the quality & performance of our products.
- If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.
Customer Service
Our team of lighting experts is here to assist you with all your needs!
Contact us at:
- Email: support@sunco.com
- Call or Text: 844-334-9938
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>