What is a programmable room thermostat?
- A programmable thermostat allows you to set the times at which you want your heating to be at a specific temperature.
- A room thermostat works by sensing the air temperature and switching on the heating when the air temperature falls below the thermostat setting, switching it off once this set temperature has been reached.
- The TP5001 programmable room thermostat has made intelligent heating control easier than ever before.
Setting Time and Date
- a. Press button, and the screen will change to show the current year.
- b. Adjust using or to set the correct year. Press to accept. Repeat step b to set month and time settings.
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required. The example below for 5/2 day setup, 4 Temperature settings
The function consists of 2 programs:
- P1 with 4 events over weekdays (Mon. To. Fri.)
- P2 with 4 events over weekends (Sat. Sun.).
- P1: Press once to activate the product.
- Press for 3 seconds to display Mo. Tu. We. Th. Fr.
P1, Event 1:
- Use or to select the start hour.
- Press to accept the setting.
- Use or to set the minute.
- Press to accept the setting.
- Use or to select the temperature.
- Press to accept the setting.
P1, Event 2–4:
- Repeat the Event 1 procedure for programming Events 2–4.
P2:
- Sa. Su. are now shown in the display.
P2, Event 1:
- Use or to select the start hour
- Press to accept the setting.
- Use or to set the minute.
- Press to accept the setting.
- Use or to select the temperature.
- Press to accept the setting.
P2, Event 2–4:
- Repeat the Event 1 procedure for programming Event 2–4.
If the working mode is set to 24 hours, only the P1 program will be available (same times each day of the week), to change this see the User settings section of this document.
Display and Navigation Details
Display & Navigations
Setting/Changing the Temperature
- a. Press or at any time to change the desired temperature value. SET is shown in the display.
- b. When releasing the or , after around 5 seconds, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting.
Holiday Mode
Holiday Mode selects the comfort temperature typically when the home is unoccupied
- a. Press M to enter into Holiday mode and will be displayed.
- b. Holiday mode temperature can be set in User settings, 07.
- c. Press M again to exit Holiday mode.
Frost Protection Temperature
- a. The thermostat is turned OFF (Standby) mode by pressing . In OFF (Standby) mode the thermostat is set to Frost Protect temperature setting and will switch the output On if the measured temperature falls below the Frost protection temperature setting.
- b. Frost protect icon and current temperature will be displayed.
User Settings
- a. Press the M button once to illuminate the screen, and next press M for 6 seconds to enter the User setting mode. Press M for parameter selection and set the parameter range via or . Complete all adjustments.
- b. To exit press , automatic exit after 20 seconds when no button is pressed.
No. | Parameter settings | Settings range | Default |
---|---|---|---|
01 | Working mode | 01: Manual |
02: Schedule timer 5/2 day
03: Schedule timer 24hr| 02
02| Heat control mode| 01: On/offload compensation
02: On/off standard| 01
03| Heat control start-up mode| 01: Normal start control
02: Delayed start control
03: Optimised start control| 01
04| Temperature limit high| Between low (05) and 35° C| 35° C
05| Temperature limit low| Between 5° C and high (04)| 5° C
06| Frost protect temperature| Between 5° C and 15° C| 5° C
07| Holiday mode temperature| Between low (05) and high (04)| 18° C
08| Timer display| 01: 24hr
02: 12hr| 24hr
09| Service due setup| Installer setting only|
10| RF Pairing (TP5001RF only)| 00: RF pairing mode off
01: RF pairing mode on| 00
11| Auto daylight saving| 01: On
02: Off| 01
- Danfoss A/S
- Heating Segment
- danfoss.com.
- +45 7488 2222
- E-mail: heating@danfoss.com.
- www.danfoss.com.
- BC337370422703en-000102
- 087R1003
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are the property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. © Danfoss | FEC | 09.2020 087R1003
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>