globe 91008631 Motion Activated LED Architectural Security Light Instruction Manual

June 1, 2024
globe

Thank you for selecting Globe as your lighting choice for your home. With proper care, this product will provide years of pleasure and enjoyment.
Carefully follow the instructions in order to ensure that this product functions safely and properly for years to come.

MOTION ACTIVATED LED ARCHITECTURAL SECURITY LIGHT

SPECIFICATIONS:

Voltage: 120 VAC ~ 60Hz
Wattage: 22W LED
Lumen: 2000LM
Color temperature: 4000K
Detection range: 180° and Max. 50 feet

THIS PACKAGE INCLUDES:

  1. Sensor

5x – Mounting screws           1x – Plastic Plug
(3 sizes included)

1x – Mounting bracket

SAFETY INFORMATION:

This light fixture requires 120-volts AC.
Some codes require installation by a qualified electrician.

WARNING: Turn the power off at the circuit breaker or fuse. Place tape over the circuit breaker switch and verify power is OFF at the light fixture.

WARNING: Risk of fire. Do not aim the lamp head at a combustible surface within 3 ft. (1 m).

WARNING: Risk of fire. Keep the lamp head at least 2 in. (51 mm) from combustible materials.

CAUTION: Keep the lamp head 30° below horizontal to avoid water damage and electrical shock.

CAUTION: Burn hazard. Allow the light fixture and the lamp head to cool before touching.

CAUTION: Do not cut any wires with factory installed wire connectors or remove the wire connectors.

NOTICE: Do not connect this light fixture to a dimmer switch or timer.

INSTALLATION:

DETERMINING THE MOUNTING LOCATION

Determine the mounting location.
Position the lamp heads in the general direction of the desired light coverage.

WALL MOUNT                     EAVE MOUNT

2. REMOVING THE MOUNTING PLATE

NOTE: This fixture comes with a mounting plate (D) pre-assembled on the light fixture (B) for shipping.

Unscrew the screw (E) connecting the light fixture (B) to the mounting plate (D) and remove the mounting plate (D)


3. PREPARING THE LIGHT FOR EAVE MOUNTING

IMPORTANT: The Motion sensor will only rotate one direction.
Do NOT FORCE the Motion sensor if it does not turn.

Determine the mounting location wall or eave mount.
While holding the light fixture (B) in both hands, carefully twist the light fixture’s sensor (2) 180 degrees as shown.
Position the lamp heads (A) in the general direction of the desired light coverage

  1. WALL MOUNT
  2. EAVE MOUNT
  3. Rotate 180° to adjust the Motion sensor

4. INSTALLING THE MOUNTING BRACKET

WARNING: Turn the power off at the circuit breaker or fuse.
Place tape over the circuit breaker switch and verify power is off at the light fixture.

Install the mounting bracket (EE) with the stamped symbol “FRONT” facing away from the junction box. Use the mounting bracket screws (AA) that best fit the junction box.
Firmly pull on the mounting bracket to verify it is securely mounted to the junction box.


5. INSTALLING THE MOUNTING PLATE

Connect the yellow and green ground wire on the fixture to the house ground wire on the fixture using the pre-installed connector.
Insert the white “Neutral (N)” wire from the house with the white wire on the fixture using the pre-installed connector.
Insert the black “Line (L)” wire from the house with the black wire on the fixture using the pre-installed connector.
Place the mounting plate (D) against the junction box.
When mounting to a wall, the “UP” arrow must point upward.
When mounting to an eave, the “UP” arrow must point toward the building.
Insert the mounting bolt (DD) through the mounting plate (D) center hole and thread it into the center hole of the mounting bracket (EE). Tighten the bolt (DD).
Firmly pull on the mounting plate to verify it is securely attached to the mounting bracket.

6. ATTACHING THE LIGHT FIXTURE

NOTE: The three pins on the rear of the light fixture must be inserted into the terminal block for the light to work.

Align the bottom edge of the light fixture (B) with the bottom edge of the mounting plate (D). Tilt the light fixture (B) toward the mounting plate (D), making sure the light fixture (B) is centered on the mounting plate (D).
Tighten the mounting screw (E) securely to the mounting plate (D). Do not overtighten.
Insert silicone plug (F).


7. CAULKING AROUND THE LIGHT FIXTURE

Caulk around the light fixture with silicone sealant (not included).

WARNING: Failure to completely caulk around the light fixture’s mounting base could result in water seepage into the light fixture and/or junction box

OPERATION:

ADJUSTING THE LAMP HEADS

WARNING: Risk of fire. Keep the lamp heads at least 2 in. (51 mm) from combustible materials

Turn the power on at the circuit breaker or fuse and turn on the wall switch.
If needed, gently grasp the lamp heads (A) and tilt them up or down or side to side to adjust the light coverage area.

2. SETTING THE SENSOR FOR TESTING

NOTE: When the ON TIME control is set to the “Test” position, the light fixture will operate during the day or night. The light will stay on for 5 seconds after all motion is stopped.

Set the “ON TIME” switch to the “TEST” position.
Set the “SENS” switch to the “H” position.
Set the “MOTION BRITE” switch to the “OFF” position.

NOTE: The motion sensor will need to completely warm up (Approximately 60 seconds) before beginning the setup process.


3. ADJUSTING THE MOTION SENSOR DETECTION ZONE

Perform a “walk test”: walk in an arc across the front of the motion sensor (C).
Watch the light. The light will come on indicating motion has been in detected.
Stop, wait for the light to turn off, and then begin walking again.
Continue this process until the detection zone has been established.
If needed, gently grasp the motion sensor (C) and move it from side to side or up and down to adjust the detection zone.
To adjust the detection zone distance, set the “SENS” switch to the “L(LOW) / M(MED) / H(HIGH)” position.

NOTE: There are built-in stops in the motion sensor (C). Do not rotate the motion sensor (C) past these stops

globe 91008631 Motion Activated LED Architectural Security Light -
c3


4. ADJUSTING THE TIME AND FUNCTIONAL CONTROL

NOTE: The “ON TIME” control determines the amount of time the light will stay on full brightness after motion is no longer detected.

To increase the time on after motion stops, press the the “ON TIME” button to toggle between “1 Min – 5 Min – 20 Min”.
When you select “MOTION BRITE” to “D2D”, the light will stay on at low brightness from Dusk until Dawn. When motion is detected, the light will light up to full brightness for the selected “ON TIME”, then will return to low brightness.
When you select “MOTION BRITE” to “6H”, the lamp is on dim brightness for 6 hours after Dusk begins. When motion is detected, the light will light up to full brightness for the “time the sensor detects motion in the area”, then will return to low brightness after no motion has been detected.
When you select “MOTION BRITE” to “OFF”, the light will remain off at night until motion is detected and will turn on at full brightness for the selected “ON TIME”.

NOTE: DO NOT LEAVE THE ON TIME SWITCH IN THE “TEST” POSITION

5. USING MANUAL MODE

NOTE: Manual mode overrides the motion sensor (C) so the light will operate full bright. This feature only works at night and only for one night at a time. The motion sensor (C) will reset to motion sensing OFF mode after 6 hours or sunrise, whichever comes first. Manual mode can be toggled on and off using a wall switch.

Ensure the power to the light is ON and the sensor has warmed up (approximately 60 seconds).
To turn manual mode ON, switch the power OFF-ON-OFF-ON at the wall switch within 3 seconds.
To turn manual mode OFF, switch the power OFF-ON-OFF-ON at the wall switch within 3 seconds.

NOTE: If the power to the light fixture is off for more than 5 seconds, allow the motion sensor to warm up prior to switching to manual mode.

  1. Less than 3 seconds
CLEAR AND CLEANING:

To prolong the original appearance, clean with clear water and a soft, damp cloth only.
Do not use paints, solvents, or other chemicals on this light fixture. They could cause a premature deterioration of the finish.
This is not a defect in the finish and will not be covered by the warranty.
Do not spray with a hose or power washer.

TROUBLE SHOOTING GUIDE:

Problem

| Possible Cause|

Solution

---|---|---

Light does not turn ON

| The fight switch is turned off
The fuse is blown or the circuit breaker is turned off.
Daylight turn-off (photocell) is in effect.
The circuit wiring is incorrect, if this is anew installation.
The motion sensor is aimed in the wrong direction.| Turn light switch on.
Replace fuse or turn circuit breaker on.
Recheck after dark.
Verify wiring is correct.
Re-aim the motion sensor to cover the desired area.

Light turns ON during the day.

| The motion sensor may be installed in a relatively dark location.
The “ON-TIME” dial is in the “TEST” position.| The light fixture is operating normally under these circumstances.
Turn the “ON-TIME” dial to the 1, 5, or 20 minute setting.

Light turns ON for no apparent reason.

| The motion sensor may be sensing small animals, automobile traffic, or other heat sources.
The “Sensitivity SENS” dial is set too high.
The “MOTIONBRITE” dial is in the 6 hour, or dusk-to-dawn setting.
The light fixture is wired through a dimmer or timer.| The fight fixture is operating normally under these circumstances.
Decrease the “Sensitivity SENS” setting.
The fight fixture is operating normally under these circumstances.
Do not use a dimmer or timer to control the light fixture. Replace the dimmer or timer with a standard on/off wail switch.

Light turn OFF too late in Dusk-to-Dawn setting.

| The light fixture may be installed in a relatively dark location.| Relocate the fight fixture or use 6 hour setting.

Light stays ON continuously.

| The motion sensor is in manual mode.
The light fixture is wired through a dimmer or timer.
The fight fixture is on the same circuit as a motor, transformer, or fluorescent bulb.| Switch the motion sensor to auto. See Using Manual Mode.
Do not use a dimmer or timer to control the light fixture. Replace the dimmer or timer with a standard on/off wall switch.
Install the light fixture on a circuit without motors, transformers, or fluorescent bulbs.

Light flashes once then stays OFF in manual mode.

| The motion sensor is in “TEST” mode and warming up.
The motion sensor is detecting fight from the lamp heads.| Flashing is normal under these conditions.
Reposition the lamp heads to keep the area below the motion sensor relatively dark.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

CAN ICES-005 (B)/NMB-005 (B)

FCC Responsible party:
Globe Electric
2264 East 6th Street
San Bernardino, CA 92410
www.globe-electric.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

globe User Manuals

Related Manuals