RAVELLI RV120 Stoves with Touch Remote Instruction Manual
- June 14, 2024
- RAVELLI
Table of Contents
- RAVELLI RV120 Stoves with Touch Remote
- Product Information
- Product Usage Instructions
- INTRODUCTION
- SAFETY INFORMATION
- What are the wood pellets
- The components of the stove
- POSITIONING, ASSEMBLY AND INSTALLATION
- Determining Size of Pipe to install
- Standard horizontal installation configurations
- CONTROLS AND USE
- PROCEDURES FOR USE
- OPERATING PHASES OF THE APPLIANCE
- Setting
- Stove phase general layout
- Thermal alarm with reset
- MAINTENANCE
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RAVELLI RV120 Stoves with Touch Remote
Product Information
- This use and maintenance manual is for stoves with touch remote control, specifically the Vittoria V – Atena V RV 120 Touch model. The manual provides instructions and information on the installation, operation, and maintenance of this pellet fuel-burning room heater. It is important to read and follow the manual to ensure proper functioning and safety.
- The manual includes safety warnings and precautions to prevent property damage, bodily injury, or even death. It emphasizes the need to consult local building or fire officials regarding restrictions and installation inspection requirements in your area. Additionally, it suggests checking with local authorities to determine if a permit is required before installation.
- The manual also highlights that the packaging provides good protection against transport damage, but it is essential to inspect the stove immediately upon delivery and report any damage to the Ravelli dealer. The drawings in the manual are indicative and not to scale.
- It is emphasized that the stove should not be used by children or disabled individuals without assistance. Touching the stove when barefoot or when any parts of the body are wet is strongly discouraged. Modifying safety or adjustment devices without authorization or instructions from Ravelli is prohibited.
- The manual mentions that the stove reaches high temperatures during operation, especially its external surfaces. Caution should be exercised to avoid burns when touching the stove. The stove is designed to function in any climatic condition, but under particularly adverse conditions (wind, freezing), safety systems may switch off the stove. In such cases, technical assistance should be contacted, and the safety systems should not be disabled.
- The manual concludes with a thank you message from Aico S.p.A., expressing gratitude for choosing their pellet stove and wishing enjoyable experiences with it.
Product Usage Instructions
- Installation: The stove must be installed and tested by specialized personnel instructed by Ravelli. Before proceeding with installation, carefully read the use and maintenance manual for instructions specific to your model. Contact your Ravelli dealer if you require further information or assistance.
- Operation: Familiarize yourself with the touch remote control and its functions according to the instructions provided in the manual. Ensure that the stove is placed on a stable and heat-resistant surface, away from flammable materials. Follow the recommended guidelines for loading the hopper with pellets, taking care not to place the bag of pellets on the stove.
- Maintenance: Regular maintenance is essential for optimal stove performance. Refer to the use and maintenance manual for detailed instructions on cleaning, servicing, and inspecting the stove. Adhere to the recommended maintenance schedule to ensure safety and efficiency.
- Safety Precautions: Always prioritize safety when using the stove. Do not allow children or disabled individuals to operate the stove without assistance. Avoid touching the stove when barefoot or when any parts of the body are wet. Never modify safety or adjustment devices without authorization or instructions from Ravelli.
- Adverse Conditions: The stove is designed to function in various climatic conditions. However, in particularly adverse conditions such as strong winds or freezing temperatures, safety systems may shut off the stove. If this occurs, contact technical assistance and refrain from disabling the safety systems.
- Consult Local Authorities : It is important to consult local building or fire officials to understand any restrictions or installation inspection requirements in your area. Determine if a permit is necessary before installing the stove.
Remember to always refer to the use and maintenance manual for specific instructions and guidelines related to your Vittoria V – Atena V RV 120 Touch stove model.
SAVE THESE INSTRUCTIONS
- Please read this entire manual before installation and use of this pellet fuel-burning room heater.
- Failure to follow these instructions could result in property damage, bodily injury or even death.
- Contact local building or fire officials about restrictions and installation inspection requirements in your area.
- Contact local authorities to see if a permit must be obtained before installation.
- ASTM E 1509-12 • UL 1482 – 11 • ULC S627-00 • Oregon Administration Rules 814-23-909 • Mobile Home Approved
INTRODUCTION
- Please read this manual carefully. It describes all the phases necessary for perfect functioning of the stove.
- The regulations on installation and operation in this manual may differ from the regulations in force locally. In this case, the indications of the competent local authorities must always be followed. The drawings shown in this manual are indicative and not to scale.
Information
- The packaging that we have used offers good protection against any damage due to transport. Always check the stove immediately after delivery: in the event of any damage, please inform your Ravelli dealer immediately.
- Description of use and maintenance manual
- With this use and maintenance manual, Ravelli wishes to provide the user with all the information on safety in using the stove, in order to avoid damage to persons or things or parts of the stove. Please read this manual carefully before use and any work on the product.
WARNINGS
- Ravelli stoves are manufactured taking care even on the individual components in order to protect both the user and the installer from any accidents.
- The authorized personnel, after any work on the product, should therefore always pay special attention to the electrical connections.
- Installation must be performed by authorized personnel, who must give the purchaser a declaration of conformity of the appliance, and who will assume all responsibility for the final installation and consequent good functioning of the product installed. It is also necessary to take into consideration all the laws and national, regional, provincial and local regulations present in the country in which the appliance has been installed. In the event of failure to respect these precautions, Aico S.p.A. declines all responsibility.
- This instruction manual is an integral part of the product: please make sure that it is always with the stove, including in the case of transfer to another owner or user, or transfer to another place. In the case of its damage or loss, please request another copy from the Technical service.
- This stove must be used for the purpose for which it has been specifically manufactured. Do not use the appliance as an incinerator or in any way other than that for which it was designed. All contractual and tort responsibility of the manufacturer is excluded for damage caused to persons, animals or things, due to errors of installation, maintenance regulation or improper use. No other fuel except the pellets must be used. Do not use liquid fuels.
- After having removed the packaging, please make sure that the contents are complete and intact.
- All the electrical components that make up the stove must be replaced with original spare parts exclusively from an authorized technical assistance centre.
- Maintenance of the stove must be performed at least once a year, planning it in time with the technical assistance centre. Do not make any unauthorized modification to the appliance.
For safety reasons, please remember that:
- the stove must not be used by children or disabled people without assistance;
- do not touch the stove when barefoot or when any parts of the body are wet;
- the safety devices or adjustment devices must not be modified without the authorization or instructions of Ravelli.
- The stove, especially the external surfaces, reaches very high temperatures when it is in operation; take care when touching it to avoid burns.
- The stove has been designed to function in any climatic condition; in the event of particularly adverse conditions (wind, freezing), safety systems could switch off the stove.
- If this occurs, contact the technical assistance and, in any case, do not disable the safety systems.
THANK YOU
- Dear Customer, We would like to thank you and congratulate you on the excellent choice you have made.
- With the Ravelli stove, you will see that quality and economy can go hand in hand, offering excellent performances with limited consumption and being totally practical. Please find below some suggestions, which we would like to give you, to obtain the most from your stove and to fully enjoy all the advantages that it can give you.
- Through this, we want to be close to our customers to offer the maximum technical support to all those who use our technology.
- Aico S.p.A. thanks you for your confidence and wishes you happy times in the company of your pellet stove.
SAFETY INFORMATION
- The stove must be installed and tested by specialized personnel instructed by the Ravelli. Please read this use and maintenance manual before installing and putting the stove into operation!
- If you require further information, please contact your Ravelli dealer.
IMPORTANT
- The place of installation of the stove must comply with local, national and Federal regulations.
- The stove must be fuelled only with quality pellets with a diameter of 6 mm as described in the specific chapter.
- The stove cannot operate with traditional wood
- The stove must not be used as an incinerator. FIRE HAZARD!!!
- Installation, the electrical connections, checking the functioning and maintenance must be performed by qualified and authorized personnel.
- Improper installation or poor maintenance (not compliant with what is shown in the following manual) may cause damage to persons and things. In this condition, Ravelli is
- relieved of all civil or criminal responsibility.
- Before connecting the stove electrically, the connection of the exhaust tubes must be completed (specifically for pellet stoves, not made from aluminium) with the flue.
- The protection grille inside the pellet hopper must never be removed.
- There must be sufficient circulation of air in the room where the stove is installed.
- Never open the door of the stove whilst it is functioning. FIRE HAZARD!!!
- The stove must not be used with the door open or with the glass broken. FIRE HAZARD!!!
- When the stove is operating, the surfaces, the glass, the handle and the pipes become overheated: during functioning, these parts must only be touched with the adequate
- protection.
- Do not light the stove without having first performed the daily inspection as described in the MAINTENANCE chapter of this manual.
- Do not place any washing on the stove to dry. Keep clothes and similar at a suitable distance from the stove. FIRE HAZARD!!!DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
- DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
- DO NOT INSTALL A FLUE DAMPER.
- DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
- Attachment and securement of the exhaust venting system to the product and to each adjoining section. All joints for connector pipe shall be required to be fastened with at least three screws. If vented horizontally, joints shall be made gaslight in a manner that shall be specified.
- Perform regular inspection, maintenance, and cleaning of the chimney and chimney connector
- Disposal of Ashes: Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, and moved outdoors immediately. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste shall not be placed in this container.
- Caution against the storage or use of flammable liquids, as follows: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this heater. Keep all such liquids well away from the heater while it is in use.
- Creosote – Formation and Need for Removal
- When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire
- The exhaust venting system should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred.
- If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
- Scrupulously follow the maintenance programme.
- Do not switch off the stove by disconnecting the electricity mains supply.
- Do not clean the stove until the structure and the ashes have cooled down completely.
- Carry out all operations in maximum safety and tranquillity.
- Coply with exhaust venting system termination requirements including location restrictions to air inlets, distances from windows, doors, and air inlets and distance to combustible materials.
- DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
- Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.
- The type of chimney shall be suitable for solid fuel and the chimney connector must be in good condition and kept clean. Establish a routine for the fuel, pellet burner and fring technique. Check daily for creosote build-up until experience shows how often you need to clean to be safe. Be aware that the hotter the fire the less creosote is deposited and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your local or fire authority for information on how to handle a chimney fire. Have a clearly understood plan to handle a chimney fire. Keep firing and deashing doors closed and maintain all seals in good conditions.
- Do not strike or slam shut the door, the glass can brake. The glass shall be cleaned only when cold, do not clean a hot glass. Use a dry cloth with normal glass detergent, do not use any abrasive cleaner.
- The type of chimney shall be suitable for solid fuel and the chimney connector must be in good condition and kept clean. When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. This room heater must be connected to a chimney complying with the requirements for type L pellet vent listed to UL641 or CAN/ULC S609 or a code-approved masonry chimney with a flue liner.
- This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. – This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.
- This heater is designed to burn wood pellet only. DO NOT BURN ANY OTHER FUEL. Burning other materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
- Do not overfire. Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater.
- Flues gases contain carbon monoxide (CO), it is recommended to install smoke monitors and CO monitors for areas that are expected to generated CO. Inspect the chimney to minimize visible emissions.
- Soot and Flyash: Formation and Need for Removal—The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.
GENERAL
- The Stove must only operate in rooms. As it is controlled by an electronic board, combustion is completely automatic and controlled and the control unit regulates the ignition phase, 5 levels of power and the switching off phase, guaranteeing safe functioning. Most of the ashes produced by the combustion of the pellets fall into the collection drawer.
- However, always check the fire pot every day, as not all pellets have high standards of quality and could leave residue that is difficult to remove.
- The glass has a special air circulation for self-cleaning. However, a slight greyish film cannot be avoided after a few hours of functioning.
- As already mentioned earlier, pellets with a diameter of 6 mm must be used with the stove.
Responsibility
- Ravelli declines all responsibility, both civil and criminal, with the delivery of this manual, for any accidents deriving from partial or total failure to observe the instructions it contains,
- Ravelli declines all responsibility deriving from the improper use of the stove, from its incorrect use by the user, by unauthorized modifications and/or repairs or from the use of spare parts which are not original.
- The manufacturer declines all direct civil or criminal responsibility due to:
- poor maintenance
- failure to observe the instructions in the manual
- use not compliant with the safety instructions
- installation that is not compliant with the regulations in force in the country.
- installation by personnel who are not qualified or authorized
- modifications and repairs that are not authorized by the manufacturer
- use of spare parts that are not original
- exceptional events
Majolica finishes
Due to the special hand finish of the majolica surface imperfections such as
shadowing my accour .Those are details that make every majolica one of its
kind. As it is a delicate material, please handle with care whilst cleaning
and avoid blows as sudden breakage may occur. Please also take care when
loading the hopper (Ed.’s note; tank containing the pellets) with the bag of
pellets: do not place it on the stove!
What are the wood pellets
- The wood pellets are made from sawdust and wood shavings produced in joiners’ shops. The material used cannot contain any foreign substance such as glue, varnish or synthetic substances.
- Subjecting it to high pressure, the wood is pressed through a plate with holes and due to the high pressure the sawdust is heated activating the natural binders of the wood. Thus, the pellets keep their shape even without the addition of bonding substances. The density of the wood pellet varies according to the type of wood and can be 1.5 – twice greater than that of natural wood.
- The diameter of the cylindrical rods is 6 mm and their length can vary between 10 and 40 mm.
- Their real weight is greather than 650 kg/m3. Due to the low content of water (<10%) they have a high energy content.
- The standards ISO 17225-2:2014 define the quality of the pellets:
- Length: < 40 mm
- Diameter: 6 mm approx.
- Real weight: > 600 kg/m3
- Lower heating value : ≥ 16,5 MJ/kg (≥ 7100 BTU/lb) Residual humidity: < 10 %
- Ashes: < 1.2 %
- Specific weight : >1000 kg/m3
- Do not put the bag of pellets on the ceramic parts during the loading operations.
- The pellets must be transported and stored in a dry place. They swell on contact with damp, and cannot be used, They must always be protected from the damp both during transport and in storage. Do not place such fuel within the space heater installation clearances or within the space required for charging and ash removal.
The components of the stove
- pellet loading auger
- electrical igniter
- combustion fire pot
- tube for passage of smoke
- air intake tube
- stainless steel heat exchanger
- pellet hopper
- baffle
- smoke exhaust tube
This drawing shows the internal parts of a pellet stove.
By filling the hopper (7), the pellets are loaded into the fire pot (3)
through the loading auger (1).
Ignition is by means of the electrical igniter (2), which overheats the air
from the special entrance (5) which on contact with the pellets will allow the
development of the flame. At this point the exhaust smoke is deviated towards
the stainless steel exchanger (6) and through the smoke extraction tube (4) it
is released into the flue, through the connection with the smoke exhaust pipe.
(9).
The combustion
-
The combustion is a chemical reaction between fuel and oxidizer. The result of this reaction is the heat. The three elements that are required for the combustion are:
- Fuel (pellet)
- Oxidizer (oxygen available in the air)
- Ignition (heat of embers or electrical ignitor)
-
To get the combustion, the combustible and the carburant must be available in a correct proportion.
-
The reaction between combustible and carburant is made by an external starter. The start can be made by the hot reaction or by a sparkle.
-
The combustion is NOT CORRECT, the flame is too tight with too much incandescent pellet in the fire pot.
-
Adjust the Set pellet/air reducing the air percentage (from 0 up to -5); in the vent this is not enough to get a proper flame, increase the loading quantity of the pellet (from 0 up to +5) to reach the flame condition shown in picture 3.
-
INCORRECT combustion, flame too drawn, in “blowtorch” style with a high quality of incandescent pellets coming out of the grate. Correct the pellet/air set by reducing the percentage of air (from 0 to -5); if not sufficient, also increase the percentage of falling pellets (from 0 to +5) to arrive to the condition in Figure 3.
If the changes made to the settings do not bring the stove to the right combustion conditions in Figure 3, contact the Technical Support Centre. -
INCORRECT combustion, “spring” flame in “wood stove” style with high quantity of pellets not burning on the grate. Firstly, check the door is closed and the ash pan. Secondly, correct the pellet/air set by increasing the percentage of air (from 0 to +5); if not sufficient, also reduce the percentage of falling pellets (from 0 to -5) to arrive to the condition in Figure 3. If the changes made to the settings do not bring the stove to the right combustion conditions in Figure 3, contact the Technical Support Centre.
-
The combustion IS CORRECT, full flame yellow/white and minimum quantity of pellet in the fire pot.
-
The combustion if fine and no ad.
-
The picture 3 show a flame done with a stove working at power P5.
Compliance status
This manual describes the installation and operation of the Ravelli, Vittoria
V, Atena V and RV 120 Touch wood pellet heater. This heaters meet the 2020
U.S. Environmental Protection Agency’s wood pellet emission limits for wood
heaters sold after May 15th 2015. Under specific test conditions this heater
has been shown to deliver heat at rates ranging from 12900 to 37000 Btu/hr.
| Emission Rate (g/hr)| Heating Efficiency (% Overall)| 1st hour
Emission Rate (g/hr)| CO emission gr/hr
---|---|---|---|---
Vittoria V| 0.6| 79.25%| 2.19| 2.8
Atena V| 0.6| 79.25%| 2.19| 2.8
RV 120 Touch| 0.6| 79.25%| 2.19| 2.8
Spare parts
Use original spare parts only. Do not use any substitute material. Do not wait
for the components to be worn before replacing them. Replace a worn component
before it is completely broken to prevent any accidents caused by the sudden
breakage of components, perform the periodic maintenance checks as described
in the dedicated chapter. Removal of broken or damaged components shall be
only done by authorized technical service.
Glass and gasket replacement
Use only ceramic type glass. To replace the glass the door needs to be
disassembled according to the below drawing.
Vittoria V – Atena V – RV 120 Touch
- Ceramic glass dimensions: 272 x 510 mm (10.71’’ x 20.08’’) thickness 5mm (0.20’’)
- Glass ribbon trecotee gasket: 8 mm x 3 mm (0.31” x 0.12”) L1540 mm (60.63”)
- Door tricovet gasket: diam. 10 mm (0.39”) L1680 mm (66.14”)
SAFETY DEVICES
- The stove is fitted with sophisticated safety systems so that, in the case of breakage of one of the individual parts or defects in the flue, no damage will be caused to the stove and the room in which it is installed. In any case, when a problem arises, the pellets stop falling immediately and the “ switch off ” phase is activated.
- The corresponding alarm will be shown on the display. The details can be seen in chapter 9 ”DESCRIPTION OF ALARMS”.
TECHNICAL FEATURES
| | Vittoria V| Atena V| RV 120 Touch
---|---|---|---|---
Height| Inch| 45.7| 45.8| 45.8
Width| Inch| 20.2| 21.1| 21.1
Depth| Inch| 22.4| 22.4| 22.4
Weight| Lbs| 420| 420| 400
Diameter of smoke exit tube| Inch| 3.1| 3.1| 3.1
Min – max hourly consumption of pellets| Lbs/h| 1.8 – 5.3| 1.8 – 5.3| 1.8 –
5.3
Supply| V – Hz| 120 – 60| 120 – 60| 120 – 60
Hopper capacity| Lbs| 50| 50| 50
Efficiency *| %| 79.25| 79.25| 79.25
Smoke temperature min – max| °F| 200 – 415| 200 – 415| 200 – 415
- *overll heating efficiency is determined using higher heating value of the fuel.
- The data shown above are indicative and not binding. Ravelli reserves the right to make any modifications for the purpose of improving the performances of the product.
Automatic cleaning system
- The stove is equipped with atuomatic brazier cleaning system. This means that there is no need to carry out daily manual cleaning of the brazier or every time the stove is lit. The automatic cleaning system is activated every time the stove is lit and after 6 hours of continuous operation. The cleaning cycle, which involves shutting down, automatic cleaning and restarting the stove, takes about 10 minutes. During this period the heating is guaranteed by the heat accumulated by the appliance itself.
- Note: the times indicated are those set by default by the Manufacturer.
POSITIONING, ASSEMBLY AND INSTALLATION
Environment of use
The positioning of the stove is decisive for a successful and equal heating of
the room. Before deciding where to place the stove, the following must be
taken into account:
-
The stove must be installed on a floor with a sufficient carrying capacity. If the existing building does not meet this requisite, appropriate measures must be taken (i.e. load distribution plate).
-
The combustion air cannot be obtained from a garage or from an area without ventilation or exchange of air, but from a free or external space
-
The stove must not be installed in a bedroom, bathroom or shower, or where there is already another heating appliance without an autonomous air flow (chimney, stove etc.)
-
A noncombustible Hearth board 6” from front of unit and 6” from the sides must be installed before unit is placed on the floor.
-
Installation is better in a large and central room in the house to ensure maximum circulation of the heat;
-
Connection to the main supply is recommended using a grounded outlet (if the cable supplied is not long enough to reach the nearest outlet, use an extension cord with a surge protector);
-
The stove must be placed in a position that receives the necessary level of air for appropriate combustion of the pellets (at least 131.23 f3/h must be available), in accordance with installation regulation and local legislations;
-
All joints for connector pipe is required to be fastened with at least three screws.
-
If vented horizontally joint should be siliconed with hi-temp. silicone and screwed so they are gas tight. (RTU 500 silicone)
-
the chimney connector shall not pass through an attic or roof space, closet or similar conceald space, or a floor or ceiling. Where passage through a wal, or partition of combustible construction is desired, the installationshall conform to CAN/CSA-B365.
The stove must be installed and assembled by qualified personnel. -
The room must be:
-
Prepared for the environmental functioning conditions
-
Prepared with an adequate system of evacuation of smoke
-
Have a 120V 60 Hz electricity mains supply
-
Do not connect this unit to a chimney flue serving another appliance
-
Use only UL Listed Type L Vent or Pellet Vent 3” in. I.D. venting system to exhaust. Do not install flue damper in the exhaust system of this unit.
-
The chimney connector and each other adjoining section must be firmly attached and secured to the stove.
-
Do not install the chimney directly at the outlet of the appliance. A chimney connector (flue pipe) is required unless the appliance is specifically approved for that type of installation.
-
It is important to use all the specified components, do not use other components.
-
“In Canada, to comply with CSA B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment, any combustible cov-ering beneath the appliance and/or within the area extending horizontally at least 450 mm (18 in) beyond the appliance on any side equipped with a door, and at least 200 mm (8 in) beyond the appliance on other sides, shall be protected by a continuous, durable, non-combustible pad that will provide ember protection. The 450 mm (18 in) ember protection required on any side with a door shall extend for the full width of the appliance plus the 200 mm (8 in) required on each side of the appliance without a door. Where an appliance is installed less than 200 mm (8 in) from a wall,
the ember pad need only extend to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is struc-turally supported to prevent displacement and distortion”. -
Specification of the chimney as a CAN/ULC-S609 listed.
-
Mobile Home Requirements
Outside air is required
- The heater must be secured to the floor using lag bolts.
- The heater must be grounded to the chassis of the mobile home.
- Installation should be in accordance with the manufactured home.
- When outside air is required, system parts, such as vent sections, supports, spark arresters, rodent screens, etc. must be used.
The space heater is to be connected to a type L pellet vent conforming to CAN/ULC S609 or UL641.
Installation shall maintain an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure.
- Operating the space heater with open firing doors can cause serious injuries and health damages due to excaping flames or carbon monoxide generation inside the room.
- Adequate ventilation is required to avoid air starvation and icing which can determine an unhealthy indoor environment.
Do not overfire.
If the space heater is not correctly installed and operated it can interfere
with smoke detectors.
Where the space heater is installed in a transportable building, removal of
the chimney for transportation of the building.
- Do not install in bedroom
- The structural integrity of the mobile home floor, ceiling, walls, roof must be maintained.
- Refer to HUD Requirements, CFR 3280, Part 24
- Install vent at clearances specified by the vent manufactures.
- Measure clearances to the nearest edge of the exhaust hood.
- Vent may not terminate in covered walkway or breezeway.
- If venting horizontally, check your venting specifications for distance pipe should extrude from building.
Vent Termination Locations
- A) Minimum 4’ clearance below or beside any door or window that opens (with outside air installed, 1’ below or beside)
- Minimum 1’ clearance below or beside any window that does not open.
- B) Minimum 1’ clearance above any door or window that opens
- C) Minimum 2’ clearance from any adjacent building
- D) Minimum 7’ clearance above any grade when adjacent to public walkways
- E) Minimum 2’ clearance above any grass, plants, or other combustible materials
- F) Minimum 3’ clearance from any forced air intake of any other appliance
- G) Minimum 2’ clearance below eaves or overhangs
- H) Minimum 1’ clearance horizontally from combustible wall
- X) Must be a minimum of 2’ above the roof ridge
Examples of installation
- This type of installation (see Pic. 4) requires an insulated flue, as all the smoke pipe has been installed outside the house.
- In the lower part of the flue, a union tee has been mounted with an inspection cap.
- A 90° bend should not be installed as the first initial piece as the ashes would quickly obstruct the passage of smoke, causing problems for the draught of the flue. (See Pic. 5).
- This type of installation (se Pic. 6) does not require an insulated flue as the smoke tube has been assembled partly inside the house and partly inside an existing flue.
- In the lower part of the flue a union tee has been installed with a peephole cap.
- A 90° bend should not be installed as the first piece, as the ash would quickly block the passage of smoke, causing problems for the draught of the flue (See Pic. 5).
- Please note the use of 2 45° bends, to guarantee that the ash falls in the union tee with a peephole.
Determining Size of Pipe to install
- To determine the diameter of pipe to use (3”or 4”), you can use the following guidelines.
- Fillout the installation chart (table 1), and calculate your total equivalent pipe length.
- Then use the total equivalent pipe length and the altitude in the pipe selection chart. (Pic. 7) to determine if your installation requires 3” or 4” exhaust pipe.
Table 1 – Installation chart
Type of Pipe | # of Elbows or Feet of Pipe | Equivalent | |
---|---|---|---|
90° Elbows/ Tee (A & G) | x | 5 feet (1.5 m) | |
45° Elbows (C) | x | 3 feet (1.0 m) | |
Horizontal (B & F) | x | 1 feet (0.3 m) | |
Vertical (E) | x | 0.5 feet (0.15 m) |
Sample installation chart
Type of Pipe | # of Elbows or Feet of Pipe | Equivalent | Total Equivalent | |
---|---|---|---|---|
90° Elbows/ Tee (A & G) | 2 | x | 5 feet |
(1.5 m)
| 10 feet
(3.0 m)
45° Elbows (C)| 1| x| 3 feet
(1.0 m)
| 3 feet
(1.0 m)
Horizontal (B & F)| 3| x| 1 feet
(0.3 m)
| 1 feet
(1,0 m)
Vertical (E)| 8| x| 0.5 feet (0.15m)| 1 feet
(1,2 m)
Table 2 – Sample chart for Pic. 8
- Equivalent pipe lenght = (10 + 3 + 1 + 1) ft = 15 ft
- If the stove is installed in a place with an altitude of 2000 ft, it is possible to use either a pipe of 3” or of 4”, as you can see in the pipe selection chart below.
- A- 90 Degree Elbow
- B- 1’ Horizontal Pipe
- C- 45 Degree Elbow
- D- Standoff Braces
- E- 8’ Vertical Pipe
- F- 2’ Horizontal Pipe
- G- 90 Degree Tee
- H- Wall Thimble
Pic. 8 – See sample installation chart
The vent pipe can be a minimum of 2 feet and a maximum of 45 feet long
Minimum distance from combustible material
NOTE: Install vent at clearances specified by the vent manufactures.
Vittoria V, Atena V, RV 120 Touch
| Unit of measurement| Corner installation| Through the wall|
Without outside air inlet
Back wall to unit (B)| Inch / mm| 2 / 51| 2 / 51| 4 / 102
Back wall to pipe| Inch / mm| 2.75 / 70| N/A| 1 / 25
Side wall to unit (L, R)| Inch / mm| 2 / 51| 2 / 51| 2 / 51
Side wall to pipe| Inch / mm| 2.75 / 70| 11 / 280| 11 / 280
Front to unit (A)| Inch / mm| 40 / 1000| 40 / 1000| 40 / 1000
Ceiling from floor| Inch / mm| 72 / 1830| 72 / 1830| 72 / 1830
Front (floor protection) (D)| Inch / mm| 6 /152| 6 / 152| 6 / 152
Side (floor protection) (E)| Inch / mm| 6 / 152| 6 / 152| 6 / 152
- Floor: combustible floor;
- Floor protection: 6 in in front and sides.
N.B. The floor protection must extend under the chimney connector and 2 inches (51 mm) beyond each side.
Standard horizontal installation configurations
-
Locate the proper position for the listed type “PL” wall thimble. Avoid cutting wall studs when installing your pipe. Use a saber saw or keyhole saw to cut the proper diameter hole through the wall to accommodate the wall thimble. Use extreme caution to avoid cutting into power lines within the wall of the home.
The hole size will depend on the brand of pellet vent that you are using. Install the wall thimble in the hole. -
ALL INTERLOCKING PIPE CONNECTIONS WITH-IN THE ROOM MUST BE SEALED WITH HIGH TEMPERATURE RTV AND SECURED WITH A MINIMUM OF 3 FASTENERS PER CONNECTION. Position the stove approximately 12” (305 mm) from the wall on the floor pad. Push the “PL” pipe through the wall thimble. Squeeze a bead of high temperature silicone (RTV) sealer around the end of the machined portion of the 3” (76mm) pipe connector on the back of the stove. Firmly push on a section of “PL” pipe until inner pipe liner pushes into the bead of RTV sealer.
-
Push the stove with pipe attached towards the wall (the pipe will go through the wall thimble). Do not position the back of the stove closer than 2” (51mm) from the wall.
-
Install listed type “PL” 45 degree elbow with optional rodent screen or cap (recommended) on outside end of pipe. The rodent screen should be no less than 1/2” (13 mm) mesh and may clog with soot and ash if left unattended during the burn season. NOTE: The end of the exhaust pipe must extend a minimum of 12” (305 mm) from the outside of the building.
-
If the installation includes a source of outside combustion air; cut a separate hole through the wall for the fresh air tube. Use a galvanized or stainless steel pipe for the duct. The minimum size for the duct shall be not less than 50% of the cross sectional flue area. Connect outside air pipe to air inlet on stove.
This tube must be terminated with a 45 degree elbow or hood.
NOTES:
- Combustion air may also be drawn from a vented crawl space under the home.
- All joints for connector pipe are required to be fastened with at least three screws. If vented horizontally, joints shall be made gas-tight (air tight, sealed connection) in a manner as specified on this page (see instruction #2).
- Install vent at clearances specified by the vent manufacturer.
CONTROLS AND USE
Control panel description
The stove is controlled by an electronic card that allows fully automatic and
controlled combustion. It allows to regulate the ignition phase, the power
levels and the shutdown phase, guaranteeing safe operation. On the back of the
stove there is a control panel that allows you to synchronise the electronic
discharge with the remote control and turn the stove on/off.
A | Serial socket |
---|---|
B | Remote control cable connection socket |
C | ADJ Radio: button to connect the remote control to the card |
D | Signaling Led |
- Red: active allergy
- Yellow: Awaiting communication with the remote control
- Green: Stove on
E| Stove on/off button
Radio touch remote control initialization
- The remote control, after a first short screen showing the Ravelli logo, will list the languages available in the menu.
- Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
- In order to operate correctly, the remote control should be interfaced with the electronic board installed inside the stove. For this reason, on display appears the following message:
- If the remote control is used for the first time, select YES using the selection keys and confirm with the dedicated key. On the display of the remote control appears the following:
- The flashing yellow LED indicates that the circuit board is waiting to receive the signal from the remote control.
- By pressing the enter key on the remote control, the components start communicating with each other. A check sign on the display, accompanied by a sound signal, shows that the initialization of the remote control has been completed successfully.
- In case of battery replacement, it is not necessary to perform the initialization procedure of the remote control. In this case, when the display will show the message “FIRST INSTALLATION ?”, select NO and press the dial key.
Description of the radio touch remote control
- The remote control looks like the following picture:
- The information below will familiarize you with the product and give you the best performance.
- Increase button “UP” (selection key)
- Decrease key “DOWN” (selection key)
- ON/OFF or reset from “Sleep” mode key.
- Display
- Key for accessing the MENU and back
- Confirmation key
In “Sleep” mode, the remote control screen is darkened, but radio communication with the stove is still active in order to reduce battery consumption.
How to insert the batteries in the remote control:
Remove the protective cover of the battery on the back of the remote control
as shown in Figure A, and insert the 3 batteries (mini pen style battery AAA
1.5V) in the housing of the remote control and observe the poles. Install the
battery protective cover as shown in figure B What happens if the
batteries are empty
- If the battery is discharged, within the “drop” is shown a symbol that indicates that the battery is empty, while maintaining active the features of your device.
- As soon as the level of the battery prevents the radio communication the remote control displays on full screen the picture of empty battery and all device functions are locked until the batteries are replaced.
- If not in use for a long time, we recommend removing the batteries from the remote control.
Description of the display
- The display of the remote control is described below (in “Home” mode):
- After 5 minutes of inactivity, the remote control display dims to “SLEEP” mode while maintaining the radio connection to the stove. A subsequent press of the ON/OFF key reactivates the display.
- The first press of any key with active display turns on its backlight, not interpreting it as a command.
The display is subdivided into three parts:
- It shows the current room temperature measured by the remote control. Moreover, if you press the DOWN scroll key you will display the temperature settings that can be changed using the two UP/DOWN keys. Any change made is confirmed automatically within 3 seconds from the change or by pressing the confirmation key. A sound signal indicates that the change has been confirme.
- Icon indicating the status of the stove (see synthetic phase diagrams).
- In the inactive phases (combined with the second part of the display) indicates the state of the stove. In the active phases, it indicates the operating power of the stove. In addition, by pressing the DOWN scroll button, you can display the power settings, that can be edited using the two scroll keys UP/DOWN: The confirmation of any change takes place automatically within 3 seconds from the change or by pressing the confirmation key. A sound signal indicates that the change has been confirmed.
Time and date setting
Below are given the steps for accessing the relative menu
- Press the increase key to change every single value
- Press the increase key to change every single value
- Press “confirm” to confirm the settings and switch to the next value.
- By pressing the key “back” for several times you will display the stand-by page.
PROCEDURES FOR USE
If the chimney catches fire you must call the fire brigade immediately.
Checks prior to start-up
You have read and perfectly understood the contents of this instructions
manual.
- Before lighting the stove, you must ensure that:
- the pellet tank is full;
- the combustion chamber is clean;
- the fire door and ash drawer seals are functioning properly;
- the electrical plug is connected correctly;
- all items that could burn (instructions, various adhesive labels) have been removed;
- the brazier, if removable, is correctly positioned in its housing.
- During the first hours of use the paints used for the stove finish may release an unpleasant odour. You might also smell the typical odour of metal parts subject to high temperatures. Make sure sufficient air circulation is guaranteed in the room. These unavoidable inconveniences will disappear after the first hours of operation. To reduce your discomfort to a minimum, keep the stove on for a few hours on low power and in the beginning, do not overload it, avoiding intense heating-cooling cycles At the initial start-up, the paint finishes drying and hardens. Accordingly, to avoid ruining it, we advise you not to touch the stove’s painted surfaces at this time
Auger loading
- Before starting the stove for the first time, whenever the stove is in alarm “06 – Pellets finished”, and in any case whenever the hopper has emptied completely, the initial feed screw loading is required. This phase serves to fill the pellet loading system so that, at the time of ignition, the correct pellet loading takes place in the brazier. In the event that the feed screw operations are not carried out, there may be stove ignition failures
- After loading the auger and before lighting the stove, always remember to empty the brazier and check that the brazier is clean. Never empty the brazier inside the hopper
- ⚠ After each maintenance operation, make sure that the brazier is positioned correctly in its seat.
- In models with self-cleaning brazier it is not necessary to remove the pellets in the brazier: the pellets loaded are sufficient for subsequent ignition
- Press the “menu access” button to access the MENU screen.
- Press the “confirm” button to access the USER screen
- Press the “confirm” button to activate feed
Switching the appliance on and off
From the “Home” screen, it is possible to switch the stove on and off by
keeping the ON / OFF button pressed on the device for a few seconds. An
acoustic signal will warn you that the appliance has switched on or off. In
case it is not possible using your remote control you can switch the appliance
on / off using the appropriate button on the electronic board.
- Do not switch off the heater by unplugging the plug from the wall socket.
- The appearance of the “SET RDS” message indicates that the initial parameter testing and calibration procedure was not carried out correctly. This indication does not imply blocking the stove (see SIGNALING POP UP section).
Failed ignition
If the system does not detect the ignition of the flame within the preset
time, operation will be blocked with the “No ignition” alarm. Before
relighting the stove, check that there are pellets in the hopper, that the
door and ash drawer compartment are closed, that there are no obstructions to
the combustion air inlet system and above all that, in models without self-
cleaning brazier, the brazier is empty, clean and correctly positioned. If the
problem persists, it could be due to a technical problem (ignition plug,
adjustments, etc …), so please contact a Ravelli CAT.
- The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new ignition.
- The brazier could be very hot: danger of burns!
- Never empty the brazier inside the hopper.
Setting operating temperature and power:
Set the two values following the indications given in the chapter “Description
of the display”
OPERATING PHASES OF THE APPLIANCE
Sequence of ignition phases
-
IGNITION – initial pellet loading phase;
-
FLAME LIGHT – flame stabilization phase and reduction of combustible inside the brazier;
-
WORK – operation phase described in the dedicated chapter;
Modulation
- During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove swift MODULATION mode in which fuel consumption is minimum.
- If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to private connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS the approx –
- ENABLE Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a thermostat with a minimum offset of 3°C if you intend to use the comfort clime function.
Description of menu functions
Press the key to access the MENU page
The TECHNICIAN and PRODUCER menus are password protected. Changing parameters within these menus could compromise the operation and safety of the stove. In this case the warranty will be invalidated.
Chrono thermostat
- With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week for each day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4). Below are given the steps for accessing the relative menu starting from “Home” mode
- The exit key shows the CHRONO menu to set other variables related to the menu functions.
- To exit the page and return to “Home” page, press the button repeatedly
Set air – pellet
- The setting of the PELLET-FLOW mixture allows to adjust the combustion by varying the quantity of pellets loaded in the brazier and/or the quantity of air. In fact, by its nature, pellets vary in grain size and composition: even bags of pellets of the same brand can have different characteristics.
- If combustion is not optimal, vary the flow parameter to adjust the combustion air. If air regulation alone is not sufficient, it may also be necessary to modify the pellet parameter.
- Combustion regulation is an operation that requires a lot of experience. We recommend that you contact an Authorised Service Centre to calibrate the stove appropriately
- To exit the screen and return to the home screen, press the key repeatedly
Stove status
Below are given the steps for accessing the relative menu starting from “Home”
mode.
In this mode you can check the proper operation of the most important parameters of the appliance. Here is a list of real data of the stove useful for service during inspection.
- RDS current reading RDS (m/s)
- RPM current smoke extractor speed (rpm)
- T fumes temperture (°C)
- Indication of stove status
- SET set value RDS (m/s)
- Df cold probe temperture RDS (°C)
- Sk: electronic board temperature (°C
To exit the STOVE STATUS screen and return to the Home screen, press the key repeatedly.
Comfort clima
Comfort clima The activation of this function enables the stove to reduce
pellet consumption by activating the modulation phases, after the desired
temperature has been reached. Subsequently, the stove checks that the
temperature is maintained steady for a preset time (DELAY SWITCH OFF). If this
condition is met, it automatically switches off, and on display appears the
writing ECO. The stove turns on again when the temperature drops below the set
threshold (DELTA RESTART). Below are given the steps for accessing the
relative menu.
- Below are given the steps for accessing the relative menu.
- Once you have accessed the Comfort Clima menu, it is possible to operate on the 3 types of settings dedicated to the function:
- The first setting allows the activation of the COMFORT CLIMA function. This function is intended to ensure that the room temperature set is maintained steady upon setting the maximum period of “X” minutes (SWITCH-OFF DELA Y: 5 MIN) before switching to ECO STOP phase.
- The STOVE maintains this state until the temperature drops below the set value (DELTA COMFORT CLIMA: 5°C). For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is reached and restarts when the temperature reaches 16°C (21°C – 5°C). You can also activate the function using an external thermostat, keeping in mind that this does not include the value of hysteresis.
Setting
- Below are the steps to follow, starting from the Home screen, to access the Home menu.
- After following the above procedure Settings > Enable thermostat
- In “Home” mode, instead of room temperature measured and settable, appears the line T ON if the room in which the thermostat is installed has not reached the temperature requested or the writing T OFF if the temperature in the room is reached.
Settings > Contrast
- With this function you can change the contrast setting to improve the display of your remote control. The contrast setting to improve the display of the remote control display.
- Use the UP/DOWN keys to change contrast setting and obtain a better visualisation of the information shown on the remote control set.
- The value can vary from 0 to 100. 50 with respect to the standard value.
- By pressing the following key you will confirm of data and switch to the page within SETTINGS menu
Settings > Firmware version
By pressing the button you will confirm the data and switch to the page within the SETTINGS menu.
Settings > Adjust
- The adjust function allows to modify the value read by the room probe inside the remote control, increasing or decreasing it by the set value (offset).
- Make this adjustment carefully and only after having checked deviations from the actual room temperature with a reliable instrument!
- UP” and “DOWN” buttons The value can vary from -10°C to 10°C. The standard value is 0°C.
- Pressing the following key allows you to confirm the data and move to the screen within the SETTINGS menu.
Settings > Language
- To access the next setting, follow the steps given above or simply remove and replace the batteries.
- The device resets and prompts you again to select the language you want to set.
Stove phase general layout
| PHASE| DESCRIPTION
---|---|---
__| FINAL CLEANING| The stove is in the switch off phase and the
cooling phase has not been completed yet.
| | | IGNITION| The heater pre-heating phase has started and the pellets
start to fall into the grate.
| | | FLAME LIGHT| The pellets ignite and take advantage of the heat in
the intake air that passes through the incandescent heater tube.
| | | WORK| The stove has completed the switch on phase and runs at
maximum set power
|
| | | MODULATION| The room temperature set has been reached.
| __| | FIRE POT CLEANING| Fire pot cleaning phase is active
(periodic function).
__| ECO STOP| With Climate Comfort active, the stove switches to
automatic switch-off mode when the room temperature set is reached (see the
dedicated section).
| | | WAITING START / RESTART| Switch-on is requested but with the stove
in cooling phase; once this condition is met, it restarts automatically.
__| IGNITION RESTART| The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
| __| | HOT SMOKES| The maximum fume temperature threshold has
been reached. To facilitate cooling, the stove brings the capacity to a
minimum with ventilation at power level 5, leading to a decrease in fume
temperature.
__| OFF| The stove is off
| | | WAIT FOR PELLETS OUT OF| When the switch-on request from ECO-STOP
mode coincides with an automatic switch-off condition (from the TIMER), the
stove turns on ensuring total cleaning of the fire pot before switching to
FINAL CLEANING.
| | | AUGER OVERFLOW|
- CONDITION: when the pellet setting (set pellets +5) is near the continuous load condition.
- SOLUTION: Set the value back to 0.
__| ALARM (generic)| The stove is in alarm state; refer to the
troubleshooting chapter.
__| ANOMALY (general)|
- The stove has detected an anomaly; refer to the troubleshooting chapter.
- By pressing the confirmation key, the problem is described.
---|---|---
__| AUTOMATIC CLEANING SYSTEM ACTIVE| For models with
automatic cleaning system it indicates the operating state of the same.
Warning Pop -Up
| ANOMALY| DESCRIPTION
---|---|---
__| SERVICE REQUEST| The threshold value of set work hours has
been reached. The symbol displayed remains active throughout the work phase.
Non-routine maintenance is required on the stove.
Alarms (table with reference codes)
| TITLE| REASON| SOLUTION
---|---|---|---
AL 01| BLACK OUT| No voltage during work phase| Press the switch
off key and switch on the stove again
If the problem persists, contact the Support Service
AL 02| SMOKE PROBE FAILURE| The smoke probe is malfunctioning|
Contact the Support Service
The smoke probe is disconnected from the electronic board| Contact the Support
Service
AL 03| OVERTEMP. SMOKE| Combustion in the fire pot is not
optimal due to clogging or obstructions of internal stove ducts inside the
stove| Switch off the stove, clean the fire pot and the tube bundle and adjust
the combustion setting the Pellet/ Air values
Contact the Support Service
| If the problem persists, contact the Support Service
AL 04| FAN BROKEN| Fume exhaust encoder is not working or is
connected incorrectly| Contact the Support Service
No power to fume extractor.| Contact the Support Service
The fume extractor is blocked.| Contact the Support Service
AL 05| NO IGNITION| The pellet tank is empty.| Check for the
presence of pellets in the container. Top up, if necessary.
Pellet calibration and suction during switch on phase is incorrect.| Contact
the Support Service
The ignition coil is faulty or positioned incorrectly| Contact the Support
Service
AL 06| NO PELLET| The pellet tank is empty.| Check for the presence
of pellets in the container. Top up, if necessary.
The gear motor is not loading pellets.| Empty the tank to see if there are any
objects inside that may prevent proper operation of the auger.
Not enough pellets loaded| Regulate pellets setting from “SET AIR/PELLETS”
| If the problem persists, contact the Support Service
AL 07| THERMAL RESET| The manual or automatic reset thermostat
connected to the hopper has been triggered / Door, drawer or pellet door
remained open| Wait for the stove to cool, reset the thermostat (if with
manual reset) by pressing the button on the back of the stove
Combustion in the fire pot is not optimal due to clogging or obstructions of
internal stove ducts inside the stove| Switch off the stove, clean the fire
pot and the tube bundle and adjust the combustion setting the Pellet/ Air
values
| Contact the Support Service
AL 08| DEPRESSION| The flue is blocked.| Check the flue is free and
clean
---|---|---|---
The vacuum meter is faulty.| Check the mains voltage.
AL 12| FUME EXHAUST SYSTEM| The fume exhaust system has a loss
of performance due to fan obstruction or voltage drop.| Check the mains
voltage.
AL 14| AUGER PHASE| No cable connection to power the gear motor|
Check the mains voltage.
AL 15| AUGER TRIAC| An internal part of the electronic board that
controls the pellet auger is faulty.| Check the flue is free and clean
Possible voltage drops or incorrect input voltage| Check the mains voltage.
AL 19| CLEANER FAILURE| The cleaner did not complete the movement
and is not in the correct position| Reset the alarm and wait for the stove to
switch to SHUTDOWN mode. Cut off and power again, the system reactivates the
cleaner searching the correct position again.
If the problem persists, contact the Support Service
Thermal alarm with reset
In the case of alarm 07 THERMAL BREAKER below shows the location where to operate to reset the manual reset.
- By pressing the button OK on the display the alarm can be reset.
- Unscrew the protection cap and press the button to reset the thermostat alarm.
- Try and repeat lighting after the cooling phase.
ELECTRICAL WIRING DIAGRAM LEGEND:
- MB- Motherboard
- T1- Fire door contact
- T2- Pellet hopper contact
- T3- Pellet thermal safety
- T4- Pressure switch
- M1- Gearmotor
- M2- Automatic cleaner
- M3- Flue gas fan
- M4- Front room fan
- M5- Rear right room fan (only for ducted stoves)
- M6- Rear left room fan (only for ducted stoves)
R1- Igniter
- S1- Flame probe
- S2- External thermostat
- S3- Room probe (opt)
- G2- Encoder reading revolutions suction
- G3- RADIO Touch handheld remote control
- G4- Automatic cleaner stroke counter
- G5- Home automation management contact
- G6- GAS ignition contact – Home automation output alarm signalling (TRF 39)
- G7- Power cord plug: main switch
MAINTENANCE
Cleaning should be provided by the user
This wood heater needs periodic inspection and repair for proper operation. It
is against federal regulations to operate this wood heater in a manner
inconsistent with operating instructions in this manual.
Before any cleaning operation on the stove, implement the following precautions:
- switch off the stove and disconnect the power cord with the stove in “Switched OFF” state;
- make sure all the parts of the stove are cold;
- make sure the ash is completely cooled.
- Please read carefully the following instructions to perform proper cleaning. Failure to comply with there instructions may lead to malfunctions of the stove.
Before carrying out any maintenance operation on the stove, please take the following precautions:
- Make sure that all the parts of the stove are cold
- Make sure that the ashes are completely extinguished
- Make sure that the general switch is in the zero position (off)
- Make sure that the plug is disconnected from the socket, thus avoiding accidental contacts.
- Please follow the instructions for cleaning shown below carefully! Failure to observe them may lead to problems in the
Cleaning the surfaces
- To clean the surfaces on the painted metal parts, use a wet cloth in water or at the most, water and soap.
- The use of aggressive detergents or diluents can damage the surfaces of the stove.
Cleaning the FIREX 600
- All Ravelli products have a combustion chamber made with FIREX 600, a material based on vermiculite, the result of research and development by Ravelli. The main features of FIREX 600 are resistant to heat, its lightness and excellent insulating capacities, im-proving the combustion and performance of the stove.
- During combustion, FIREX 600 turns white, due to an effect called PYROLYSIS, making the flame clear and shining. If the combus-tion is regulated in an optimal way, the FIREX 600 interior always remains clean and white.
- The condition of FIREX 600 is therefore a thermometer to understand whether the combustion is good or not.
- FIREX 600 LIGHT – GOOD COMBUSTION
- FIREX 600 DARK – POOR COMBUSTION
- Firex 600 does not require special maintenance, it only has to be dusted with a soft brush to remove the ash that is deposited during combustion.
- Abrasive sponges to clean to most resistant waste should not be used as they could compromise the thickness of the FIREX600 panel, creating critical points of breakage.
- The tube of the vacuum cleaner should not be used in direct contact with FIREX 600.
- Wet cloths should not be used to clean FIREX 600.
- FIREX 600 is resistant to heat but not to knocks; handle with care if moved.
- FIREX 600 may show a slight abrasion after a few hours of functioning, this is perfectly normal as the flame creates microgrooves in the panel without compromising it.
- The duration of FIREX 600 depends only on how maintenance is carried out.
- The pellet stove is a generator of heat with a solid fuel and as such requires servicing by qualified personnel at least once a year at the start of the season. This maintenance has the purpose of ascertaining and ensuring the perfect efficiency of all the components. We recommend you draw up an annual contract for maintenance of the product with your installer/dealer.
WARRANTY
Read the warranty conditions contained below.
Warranty conditions
- The warranty for the Customer is acknowledged by the Dealer under the terms of law.
- The Dealer acknowledges the warranty only if the product has not been tampered with and only if it has been installed in accordance with the Manufacturer’s instructions.
- The limited warranty covers manufacturing material defects, as long as the product has not broken sue to an incorrect use, negligence, incorrect connection, tampering, installation errors.
- The warranty becomes null and void even if only one requirement in this manual is not complied with.
The following are not covered by warranty:
- the combustion chamber refractory stones;
- the door glass;
- the gaskets;
- the paint job;
- the stainless steel or cast iron fire pot;
- the electric resistance;
- the Majolica cladding;
- the aesthetic parts;
- any damages caused by unsuitable installation and/or use of the product and/or shortcomings on the part of the customer.
The use of poor quality pellet or any other unauthorised fuel may damage the product’s components, cause its warranty to be voided and as a result eliminate the connected manufacturer liability.
- It is therefore recommended to use good quality pellet that fulfils the requirements listed in the dedicated chapter.
- All damages caused by transportation are not recognized, for this reason it is recommended to carefully check goods upon receipt, immediately warning the reseller of any damage.
Registration of warranty
To activate the warranty, it is necessary to register the product on the
Guarantee Portal on the website www.ravelligroup.it, by entering your data and
the purchase receipt .
Info and problems
Dealers authorised by Ravelli use a trained Technical Service Centre network
to meet the Customer’s requirements. For any information or request for
assistance, please contact your Dealer or the Technical Service Centre.
Aico S.p.A. Headquarter
- Via Consorzio Agrario, 3 – 25032
- Chiari (BS) – Italy
- Research and Development Centre
- Viale del commercio 12/a – 37135
- Verona (VR) – Italy
- T. + 39 030 7402939
- info@ravelligroup.it
- FB Ravellifuocointelligente
- IG ravellistufe
- www.ravelligroup.it
- Aico S.p.A. d oes not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products and to the present manual without notice.